Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Jul 2026, 6:55 pm5d left
Commissioner, Municipal Corporation Udaipur
Municipal Corporation Udaipur, Town Hall Link Road
SUPPLY OF FIRE FIGHTING EQUIPMENTS FOR USE IN THE FIRE BRIGADE OF UDAIPUR MUNICIPAL CORPORATION ON ANNUAL RATE CONTRACT. (e_01 / Fire_01)
2026_DLB_573136_1
E_01_2026-27_Fire _ Fire Equipments
Global Tenders
Miscellaneous Goods
365 days
Udaipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Commissioner, Municipal Corporation Udaipur
₹90,000
4 Jul 2026
4 Jul 2026
14 Jul 2026
4 Jul 2026
13 Jul 2026
4 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing Gum Boot Technical Specification Product: Electrical Insulating Fireman Boot
Size range Euro: 36 – 50 , UK: 3½ - 14½ US: 4½ - 15½
Type of construction : Vulcanized Rubber Upper and Sole /Coated steel toe cap.
Recommendation : Structural fire fighting, General fire rescue, Bush fire fighting European Standard CE Approved suitable for fire rescue, fire suppression, property conservation & etc.
High Electrical Resistance Outsole, Heat Insulation, Cold Insulation Slip Resistance on ceramic tile with Sodium Lauryl Sulphate, Fuel Oil Resistant Outsole, Heel Energy Absorption, Nail Penetration Resistance, Toe Protection, Resistant to hot contact
Toe protection, Compression resistance, Nail penetration resistance, 18 kV Electric Shock Resistance protection
Lining Material : Extra comfort with woven cotton canvas
Upper construction : Flame retardant upper with heat insulation Waterproof
Reinforced rubber , High visibility with black and yellow contrast
Sole / Heel : Flame retardant rubber outsole
Fuel oil resistant sole suitable for inimical environment
Slip resistant vulcanized rubber outsole Excellent abrasion resistant for extra durability
Heel energy absorption design to minimize heel impact
Catered to enter high temperature
Cold insulation sole construction
Slip Resistance Performance Twice That Required By EN 13287 SRA And SATRA TM144 Standards
Resistance To Hot Contact 60 Seconds 300°C
Steel Toe Cap : Epoxy coated toe caps for anti-corrosion Meets impact and compression tests
Metal toecap provides reliable protection in cold & hot environments
Steel Midsole
Non-corrosive stainless steel
Withstands pin & sharp objects
Chemical Resistance : Sole & Upper - Resistant towards strong acids and alkali
Finishing : Lacquer coating for weather protection Prefered make :- Novex, Udhyogi or equivalent | 1 | Each | 1 | ₹1 |
| 2 | Helmate
New, modern design and excellent protection properties. Optimal relationship between protection and comfort with a broad spectrum of optional upgrades. Structural firefighting has never been safer.
PERFORMANCE
Extreme temperature resistance
(up to 1,000°C in a 10 second flash over flames)
Long-term temperature resistance (radiant heat test 14 kW/m2)
High resistance to mechanical impacts Low-temperature classification -
30°C SAFETY
Electrical insulation capacity head protection (including neck and face) Interior shock absorber.
Reflective elements for better visibility in low-light conditions
Neck protector (available in aluminised fi bre, Nomex, genuine leather or wool for Holland style)
3 point chinstrap (tested to prevent skin irritation, fire retardant aramid tape) Chemical resistance
COMFORT
Lightweight
Integrated adjustment system
One shell size for head sizes from 52 to 64 cm Wide range of accessories and high level of personalisation
HIGH TECH MATERIALS
Flame retardant and high temperature resistant composite Anti-scratch and anti-fog coated integrated visor Anti-se :- Hicare, Karam or equivalent
Firemen Helmet
The Fireman Helmet Light Weight 1400 Gms Helmet Having Flame Retardant Shell With Reflective And Luminescent Stripes | 1 | Each | 2 | ₹2 |
| 3 | Self-Contained Breathing Apparatus
1. General Requirement:
The Self-Contained Open Circuit Type Compressed Air Breathing Apparatus Set With Spare Cylinder Confirming IS 10245
2. Back Plate (Body Harness):.
The Ba Set Back Plate Of Should Be Ergonomically Designed And Flexible.
The Ba Set Back Plate: Should Be Adjustable Type ( To Extend Back Plate Height As And When Required )
The Ba Set Back Plate Harness Padded And Made Of Flame Retardant Material
The Hoses Channeled Within The Back Plate To Prevent Snag Hazard
The Cylinder Strap Shall Be Made Up Of Flame Retardant Material With Velcro And Which Can Be Adjusted To Accommodate All
Standard Cylinders.
All Securing Buckles Shall Be Designed In Such A Way For Accessibility And Easy Handling With Gloved Hands Without Compromising
Security.
* The Back Plate Should Be Analog And Digital Pressure Gauge At One Side To Indicate Pressure Of The Cylinder And The Other Side The Breathing Air Hose Quick Fit Coupling, Through Which Demand Valve Is Inter Connected
The Ba Set Back Plate Should Be Breathing Air Hose Design With Quick Fit Coupling, It Option To Interconnect "y" Piece Coupling
For Second Line Rescue With Demand Value And Face Mask In An Emergency.
3. Facemask:
The Face Mask Shall Be Of Positive Pressure Type
It Should Be 5 Point Head Harness Made Of Kevlar / Rubber
It Should Be In Built Communication System, With A Radio Jack To Connect Walkie-Talkie.
It Should Be Also The Facility Of Push To Talk With A Button.
It Should Be Integrated With In Built Amplifier For Excellent Communication And Distress Alarm.
It Should Be 2 Led And It Blink, If Distress Alarm Is Activated.
The Facemask Shall Feature A Full Mask Assembly Shall Be With Reverted Edge Seal And Made Of Soft Skin Friendly Silicone Material
With Flame Resistance Requirement
Visor Shall Be Of Multi Curvature Type And Provide Wide-Angle Vision With More Than 85% Field Of Vision And Be Made Of
Replaceable Scratch And Heat-Resistant Hard Coated Polycarbonate Material.
Visor Shall Be Self-Demisting Type Through Special Control Of Inspired Air
It Integral Inner Mask Shall Reduce Dead-Space And Co2 Build Up And Eliminate Misting Of Visor. | 1 | Each | 3 | ₹3 |
| 4 | High led search light Range up to 1 km
MATERIAL
The body is made of highstrength but light weight ABC plastic, lending it rigidity and toughness even in situations of rough handling. Whatever the situation, you can laways bank on this solidly built, rain-proof FOS LED Search Light.
LED POWER
Featuring a high power
55W branded LED coupled with a big parabolic
reflector, this FOS rechargeable torch offers unmatched luminosity of up to 1800 lumens with a focesed beam range visibility of up to 2 kms.
BATTERY POWER
Powering the LED is a high-performance 8000 mAh, 7.4V Lithium-ion battery which offers a battery backup of up to 9 hours. The package comes with 2 battery chargers, an AC Wall Charging Adapter and a Car Charging Adapter, both with 9 V-1 Amp. Output.
LIGHT MODES
This heavy duty ewchargeable handheld torch comes with 2 light brightness modes, i.e. super strong and strong, which can be used as per your lighting needs.
User Application
Heavy duty outdoor ultra-long-range lighting applications as commercial search operations for Armed Forces, Industries, Security Agencies. Preferred make :- DETECH, FOS or equivalent. | 1 | Each | 1 | ₹1 |
| 5 | Multi Purpose Branch / Select flow nozzle Whight : 4.3 kg approx
Connection-21/2",2", 11/4"
Application-FIRE FIGHTING
Material-Aluminum, Alloy, Stainless Steel Size-63mm, 40mm, 50mm
Flow- 600LPM, 800LPM,900LPM, 1200LPM
Working Pressure 5 to 12KG/CM2
Hydrulic Test- 30KG
Inlet Connections- 63MM, 40MM, 50MM Prefered make : - Newage, Onspot or equivalent | 1 | Each | 1 | ₹1 |
| 6 | Lower Pressure Applicator
Inlet -
Pipe - Aluminum Alloy
Nozzle - Brass Extruded Rod
Size - 63 mm Male instantaneous inlet
Test Pressure - 21 Bar
Working Pressure - 7 Bar
Discharge Pattern - Water Curtain Pattern
Flow Rate - 130 LPM @ 7 Bar
Discharge Range - Throw Range: 7 m Minimum
Finish - Natural SS Finish Polished Prefered make :- Newage, Onspot or equivalent | 1 | Each | 1 | ₹1 |
| 7 | Fire Resistant Dangries
* 100% COTTON Fire Retardant Premium Fabric in 230 GSM
adhering to ISO 11612:2015 A1 and A2.
* 2 Front pockets with Quality Ring Buttons, 2 side pockets, 1 tool pocket, 1 sleeve pocket and 2 back pockets.
* For high visibility, 2 inch Fire retardant 3M reflective tapes have been stitched on the shoulder, sleeves and on the knees.
* Fire retardant YKK zippers front closure, ring buttons on sleeves for closure All the stress points have been bartacked.
* The size is as per actual and gives a smart fit look however if you need a lose fit or if worn above work clothes then go 1 size bigger.
FABRIC SPECIFICATION-
Premium 100% Cotton per-shrunk Fire retardant premium Fabric in 230 GSM adhering to ISO 11612:2015 A1 and A2. Size M,L,XL, XXL Prefered make :- French terrain, safe wear or equivalent | 1 | Each | 1 | ₹1 |
| 8 | Fire Proximity Suit Coat/Jecket
1. General Description: Coat with a high central zip closure, covered with suitable storm flap. The coat should have full-length sleeves and a stand up collar with adjustable throat tab.
2. Standard: The coat must meet the NFPA 1971:2007 or
3. Construction a. The coat should have a three-layer construction:
b. Outer Cloth: The outer shell fabric should be made from inherently flame resistant fiber with requisite blend of antistatic fibers. The colour of the outer shell be Dark Navy Shade.
c. Moisture Barrier: Moisture
Barrier shall be Fire resistant and
breathable in nature. The construction should be micro porous in nature like non wovensubstrate / felt / PU / spun lace aramid – suitably laminated with PTFE / PU like membrane or treated with compound to ensure that no water ingress from outside besides allowing perspiration and heat to escape from inside.
d. Thermal Barrier: The Thermal Barrier should consist of two integrated or quilted layers. The innermost layer facing the Moisture Barrier should be made from inherently flame resistant fibres in non wiven felt / corded lane construction.
e. The should be detachable i.e., it should be able to be used as a single layered Coat or multiple layered Garment and should be detachable by buttons from inside.
f. Seams: All sewing to be done using para-aramid or equivalent strong inherently FR thread. The seams on the outer layer should be stitched with strong thread overlock.
g. Pockets: Coat should be provided with 3 pockets as standard. 2 waist pockets on the lower fronts with flap closure and 1 patch pocket inside the coat.
h. Collar: The collar of the Coat should be designed so that the neck portion is doubley secured and covered by means of a throat tab, fitted with fire retardant Velcro for secure fastening across the neck. A hanger loop, centrally placed on outer collar or inside section to be provided to facilitate hanging.
i. Front Closure The coat should have a heavy-duty moulded zip beneath a full length catch flap, closing with fire retardant Velcro.
j. Sleevs & Cuffs: The sleeve should be designed to have an additional gusset (all 3 layers) in the underarm or any other design innovation to allow the arms to move freely without raising the hem of the coat. An aramid rib-knitted internal cuff to be provided for suitable wrist protection.
k. Reflective Tape: The Coat should have a high quality reflective tape provided at the following places. - Single row 50 mm width, around hem / waist (including across front flap) - Single row 50 mm width,around lower sleeves The tape should be premium quality and the quality should comply with the length and test parameters stipulated in the corresponding NFPA /
En standreds.
I. Sizing: Size chart should be provided along-with the offer. The size should be suitable for fitting on person of 5'10" & 5' 8" height.
m. Labels: A large clear label should be permanently attached (sealed) or stitched inside the lining of the fire suit. This label should give full details of compliance to international standards, manufacturers' contact details, sizing, wash/care information, style and date of manufacture and traceability coding. Prefered make :- flare defend, safe wear, udhyogi or equivalent | 1 | Each | 1 | ₹1 |
| 9 | ANTI FIRE HOODS
STANDARDS: Certified to NFPA 1971
FEATURES: The Hood should be off
The face opening should be Fit and Flat The Neck Protector should be fit and properly covering the
The Hood should be double layered having each layer of the Fabric of about 230 GSM, inset collar and face opening with elastic. Prefered make :-flare defend, safe wear, udhyogi or equivalent. | 1 | Each | 1 | ₹1 |
| 10 | Fire Entry Suit
1 Aluminized fire entry suit containing coat (flame seal) with pants, having hood for thermal protection with gold plated tempered glass layers, overall gloves, flame retardant shoes/boots and a back pouch for wearing breathing apparatus set.
2 Size- medium
3 Made from Z-Flex (NFPA 701/UL 214 certified) & Zetex fabrics.
4 Other specifications: material: 8 layers construction includes: aluminized Z-Flex outer shell, Z-Sil, 1-inch fiber-glass insulation,
aluminized vapour barrier, zetex plus, 1- inch fiber glass insulation, aluminized vapor barrier, flame-resistant cotton lining. (i). Temperature rating: short duration ambient heat of1500 F (815 C, total flame of 2000 F (1093 C), Radiant heat to 3000 f (1650 C) for 3000 series.
5 (Hood, coat, pants, boots) construction
1. Hood: Designed for use with an air mask. Built-in shell for structural support. Inner drape seals and underarm adjustment straps Ratchet-adjustable hard cap with speedy clip for support Hardened aluminum window frame with two gold-plated tempered glass lenses backed by two additional lenses for thermal protection.
2. Coat: double storm fly front. Flame seal with drawstring at coat bottom.
3. Pants: high waist with 2" wide adjustable suspends and adjustment straps on leg bottoms.
4. Boots: designed to fit over work shoes. Rear entry with overlap snap enclose and adjustable take-up straps. Boot sole made from 2" of layered insulation, flame retardant cotton lining, aluminum foil, and wire-reinforced, flame-retired neoprene fiber glass.
5. Mitts: heavy construction; made with zetex plus fabric. Aluminized outer layer.
Certification: EN 532-1992 limited flame spread, EN 367:1992 convective heat, EN 366:1993 method B radiant heat, EN 407:2004 molten metal splash.
Technical Approval: The Bidder Should Be Submit Product Data Sheet And Valid Certificate At The Time Of Tender Submission.
If The Bidder Firm Is Manufacturer Then Firm Has To Submit The Valid Registration Certificate. If The Bidder Firm Is Not The
Manufacturer Then Firm Has To Submit The Valid Manufacturer's Authorization Certificate For This Particular Tender. The Bidder Shall Conduct A Successful Demonstration Of The Quoted Product Explaining All The Features Detailed In The Above Point Wise Specification, Failing To Provide A Successful Technical Demonstration The Bid Would Be Technically Rejected.
Guarantee And Training Guarantee Minimum 1 Year Without Any Manufacturing Defects From Date Of Receipt Material Free Of Cost Training & Service For The 1 Year At Our Site.
Operation And Maintenance Manual: The Manufacturer Supply Operation And Maintenance Manual With Each Set Along With Supply. | 1 | Each | 1 | ₹1 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 13.59 MB
BOQ_1019558.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid