Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.3 L+₹2.3 L (12.1%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹21.9 L+₹2.9 L (15.3%)Rejected-Finance SHOP NO 107 MOHAN SINGH PLACE NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹23.3 L+₹4.3 L (22.8%)Rejected-Finance 2817 20 GURU NANK AUTO MKT KASHMERI GATE DELHI 6 | L4 | Rejected-Finance L4 |
Tender Value
₹23.6 L
EMD Value
₹48,300
Closing Date
23 Feb 2023, 10:00 amClosed
Atul Bhardwaj
Hauz Khas
Provision of Semi High mast light poles with LED flood light fittings at various locations in Ambedkar Nagar Constituency (AC-48) under South Zone.
2023_SDMC_145636_4
EEE/SZ/2022-23/47
Open Tender
Electrical Works
Works
60 days
South Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹48,300
30 Jan 2024
15 Feb 2023
23 Feb 2023
15 Feb 2023
23 Feb 2023
15 Feb 2023
Amount
Laying and Jointing PVC Pipe. Heading
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting outthe excavated soil and disposal of excavated soil as directed within a lead of 50 metres
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form worketc. as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of 4 nos foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c,4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured cable 1.1KV grade Conforming to IS 7098/1988 of following Sizes (a) 2 X 4 SQmm
Providing and laying of HDPE pipe of 40 mm outer dia with PN 4 rating by hand moling/Mannual method conforming to 4984 592.
Providing and fixing of Stainless steel name plate of size 6X8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required.
Providing and Fixing FRP Fencing at electrical Installation with necessary concreting for ground vertical post, hardware, accessories, fittings etc of 2000 mm height above the ground and 300 mm grounding in ground minimum along with fencing 1 no of FRP gate with necessary hardware, accessories, brass/ stainless steel metal lock fittings etc of suitable length, width & height i.e. i number gate as per site requirement.
M/S JAGLAN CONSTRUCTION
Aviadu energy and infra pvt ltd
KHANNA SALES CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .