EXECUTIVE ENGINEER (SDW) I
KILOKARI SPS JAL VIHAR LAJPAT NAGAR NEW DELHI-110024
Electrification work of AE(C) Enquiry office AND type III staff quarter at Jal Vihar Colony
2024_DJB_256259_2
NIT_NO_12 (2023-24) EE(SDW)-I
Open Tender
Miscellaneous Works
Works
30 days
Jal Vihar Colony
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
DJB EMD A/c No. 50448339804 at Indian Bank, Cope
₹10,100
Yes
1 Apr 2024
15 Mar 2024
26 Mar 2024
15 Mar 2024
26 Mar 2024
15 Mar 2024
Electrification of quarter No. A-2 old Type-III staff quarter and AE (C) Enquiry office at Jal Vihar Colony by carrying out following works:- 1.8 Wiring for light point / fan point / exhaust fan point call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed conduit, with piano type switch, phenolic laminated sheet, suitable size MSbox and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.1 - Group-A.
1.8.3 - Group-C.
1.14/3 Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.14.2 4 x 10 sq. mm + 2 x 6 sq. mm earth wire
1.29/6 Supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in fron including providing and fixing 3 pin 5/6 Amps. Socket outlet and 5/6 Amps piano type switch, connection, painting etc. as required. (For light plugs).
1.30/6 Supplying and fixing metal box of 180mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. required.
1.25/6 Supplying and fixing two module stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc. as required.
1.33/7 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34/7 Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.38/8 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1.41/8 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44/8 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length upt 30cm with 1.5 Sq. mm FRLS PVC insulated, copper conductor single core etc. as required.
1.50/9 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
2.2/12 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator). 8 way, double door.
2.10/12 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 - Single pole.
2.14.3/12 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A.
Making good the damages by required civil work as per requirement.
Premier Engineering Company
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .