| 1 | L1₹8.0 LAccepted-AOC AT JAWAHAR NAGAR P O BERMO DIST BOKARO JHARKHAND 829104 | BERMO | BOKARO | JHARKHAND | 829104 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.1 L+₹33,761.64 (5.00%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.3 L+₹53,877.13 (7.98%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹8.0 L
EMD Value
₹10,000
Closing Date
21 Feb 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PE ENM
PE ENM,. AKKOCP
A.Extension of 3.3 KV Overhead Line at CRE Point and shifting of overhead near 4 pole under AKKOCP, BnK Area (BOQ 1-13), B.Erection of 3.3 KV OH Electric Line feeding power to pumping stations with installation of GOAB switch of Konar Exp. OCP, BnK A
2024_CCL_301444_2
PE(EnM)/AKK OCP/e-tender/23-24/64
Open Tender
Electrical and Maintenance Works
Item Rate
12 days
AKKOCP
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
8 Apr 2024
14 Feb 2024
22 Feb 2024
15 Feb 2024
21 Feb 2024
15 Feb 2024
15 Feb 2024 - 21 Feb 2024
Amount
Erection of metallic pole (above 10 m and upto 12 m) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 7 nos for EKG and 4 nos Main Sump
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required (50 m x 3 phase x nos of span x 0.214 kg (for Rabbit Conductorr)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required - 2 nos for Main Sump and 2 nos for EKG
Supplying of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Erection of disc/ pin insulator for 11 KV over head lines as required. (27 no. Disc Insulator & 9 no. Pin Insulator)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm x 50 mm x 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Transporting of Poles from stock to work site
Dismentalling of 11 KV, 400 Amp, 3 insulators Gang Operated Air Break Off Load Disconneting Swtichgrear, Vertival rocking type
Erection cost of 11 KV, 400 Amp, 3 insulators Gang Operated Air Break Off Load Disconneting Swtichgrear, Vertival rocking type
Erection of metallic pole (above 10 m and upto 12 m) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required (50 m x 3 phase x 3 span x 0.394 kg = 177.3 kg) (for DOG Conductor)
Supply & erection of 8 SWG G.I. wire (for Earthing & Cradling): 350 m x 0.116 kg = 40.6 kg
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Supplying & erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying & erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm x 50 mm x 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying & erection of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. ((50 m x 3 phase x 4 span x 0.394 kg = 236.4 kg)
Transporting of Poles from stock to work site
Supply and providing of 11 kV, 400 A, 3 Insulators Gang operated Air Break Off Load Disconnecting Switch, horizontal rocking type.
Installation of 11 kV Air Break Switch
Erection of metallic pole (above 10 m and upto 12 m) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required (50 m x 3 phase x 8 span x 0.394 kg = 295.5 kg) (for DOG Conductor)
Supply of 6 SWG G.I. wire ((55X 2 +50)X 0.131 KG/M* span
Erection of 6/ 8 SWG G.I. wire (55 m x 8) + (55 m x 3) = 605 m x 0.131 kg = 79.255 kg
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Erection of disc/ pin insulator for 11 KV over head lines as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm x 50 mm x 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. ((50 m x 3 phase x no of span x 0.394 kg )
Erection of metallic pole (above 10 m and upto 12 m) in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required (50 m x 3 phase x nos of span x 0.214 kg (for Rabbit Conductorr)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required - 2 nos for Main Sump and 2 nos for EKG
Supplying of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Erection of disc/ pin insulator for 11 KV over head lines as required. (27 no. Disc Insulator & 9 no. Pin Insulator)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm x 50 mm x 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Transporting of Poles from stock to work site
Total impact of GST for the purpose of CTC
S KUMAR ENTERPRISES
CITY ELECTRICALS
techsummary_312279.pdf
PDF • 0.32 MB
finsummary_312279.pdf
PDF • 0.23 MB
WO.pdf
PDF • 0.26 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .