Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.8 LAccepted-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | 1 | Accepted-AOC Being the lowest tenderer and fulfilling all criteria | |
| 2 | 2₹42.0 L+₹4.7 L (12.7%)Rejected-Finance 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | 2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | 3₹43.5 L+₹6.3 L (16.8%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest tenderer | |
| 4 | 4₹58.2 L+₹20.9 L (56.0%)Rejected-Finance 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | 4 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
8 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chennai
Garrison Engineer Fort Saint George Chennai
UPGRADATION OF EXTERNAL ELECTRIC SUPPLY AT DB AREA COMPLEX SPL REAPAIR TO LT UNDER GROUND CABLE NEAR BLDG NO P-IV AND CERTAIN SANCTIONED MINOR WORKS UNDER GE CHENNAI
2022_MES_519278_2
8579/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
Fort Saint George Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Chennai
₹93,000
Yes
22 Aug 2022
18 May 2022
15 Jun 2022
18 May 2022
8 Jun 2022
25 May 2022
60 days
Amount
BOQ UPLOADED ON 18 MAY 2022
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for foundation, or for shafts, wells, cesspits, manholes, laying cable etc. n. exc. 10 sqm on plan and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, laying/ spreading in trenches clean dry river/M sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and directed. Note: Punned thickness only will be considered or payment.
Supply and laying well burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and directed.
Laying only old size burnt bricks, laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and as directed. Note: Old re-useable bricks obtained during taking out of cable shall be re-used.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 6 Sqmm x 2 Core with glands, cable protection pipes, cable route indicator etc., complete from the trenches/fixed on wall (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as s specified and directed by the Engr-in-charge. Note ;- excavation and earth work shall be measured and paid separately under appropriate items.
All as per Item No. 7 above but 10 Sqmm 2 Core
All as per Item No. 7 above but 16 Sqmm 4 Core
All as per Item No. 7 above but 25 Sqmm 3.5 Core
All as per Item No. 7 above but 35 Sqmm 3.5 Core
All as per Item No. 7 above but 50 Sqmm 3.5 Core
All as per Item No. 7 above but 70 Sqmm 3.5 Core
All as per Item No. 7 above but 95 Sqmm 3.5 Core
All as per Item No. 7 above but 150 Sqmm 3.5 Core
All as per Item No. 7 above but 185 Sqmm 3.5 Core
All as per Item No. 7 above but 240 Sqmm 3.5 Core
Relaying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of serviceable PVC/XLPE 1100 volts grade, LT UG electric cable of size 25 Sqmm x 3.5Ccore cable obtained vide Item No. 10 above all as per existing make and as directed.
All as per Item No. 18 above but 35 Sqmm 3.5 Core
All as per Item No. 18 above but 50 Sqmm 3.5 Core
All as per Item No. 18 above but 70 Sqmm 3.5 Core
All as per Item No. 18 above but 95 Sqmm 3.5 Core
All as per Item No. 18 above but 150 Sqmm 3.5 Core
All as per Item No. 18 above but 185 Sqmm 3.5 Core
All as per Item No.18 above but 240 Sqmm 3.5 Core
Supply and lay in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of PVC/XLPE 1100 volts grade, LT UG electric cable with aluminium conductor 1100 Volts grade of size 6 Sqmm x 2 Core cable complete all as specified and as directed.
All as per Item No. 26 above but 25 Sqmm 3.5 Core
All as per Item No. 26 above but 10 Sqmm 2 Core
All as per Item No. 26 above but 16 Sqmm 4 Core
All as per Item No. 26 above but 35 Sqmm 3.5 Core
All as per Item No. 26 above but 50 Sqmm 3.5 Core
All as per Item No. 26 above but 70 Sqmm 3.5 Core
All as per Item No. 26 above but 95 Sqmm 3.5 Core
All as per Item No. 26 above but 150 Sqmm 3.5 Core
All as per Item No. 26 above but 185 Sqmm 3.5 Core
All as per Item No. 26 above but 240 Sqmm 3.5 Core
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable of following sizes 06 to 16 Sqmm 2/4 Core complete all as specified and as directed by the Engr-in-charge. Make : 3M
All as per Item No. 37 above but of size 25 to 50 Sqmm 3.5 Core
All as per Item No. 37 above but of size 70 to 120 Sqmm 3.5 Core
All as per Item No. 37 above but of size 150 to 185 Sqmm 3.5 Core
All as per Item No. 37 above but of size 240 to 300 Sqmm 3.5 Core
Supply and laying GI tube light grade 50mm bore with all fittings laid in trenches/ floor/fixed on walls with suitable clamps and jointing GI pipe etc., complete all as specified and directed.
All as per Item No. 42 above but of size 80mm dia.
All as per Item No. 42 above but of size 100mm dia.
Taking down MCCB any type and any size any make after proper shut down from main control panel board complete all as specified and directed by the Engr-in-charge.
S&F MCCB adjustable thermal & magnetic seting 415V, 3 pole, 50 Hz, of capacity 63 Amps 16 KA complete all as specified and directed by the Engr-in-charge.
S&F MCCB adjustable thermal & magnetic seting 415V, 3 pole, 50 Hz, of capacity 100 Amps 16 KA complete all as specified and directed by the Engr-in-charge.
S&F MCCB adjustable thermal & magnetic seting 415V, 3 pole, 50 Hz, of capacity 125 Amps 36 KA complete all as specified and directed by the Engr-in-charge.
S&F MCCB adjustable thermal & magnetic seting 415V, 4 pole, 50 Hz, of capacity 160 Amps 36 KA complete all as specified and directed by the Engr-in-charge.
S&F MCCB adjustable thermal & magnetic seting 415V, 4 pole, 50 Hz, of capacity 200 Amps 36 KA complete all as specified and directed by the Engr-in-charge.
S&F MCCB adjustable thermal & magnetic seting 415V, 4 pole, 50 Hz, of capacity 250 Amps 36 KA complete all as specified and directed by the Engr-in-charge.
S&F MCCB adjustable thermal & magnetic seting 415V, 4 pole, 50 Hz, of capacity 4000 Amps 36 KA complete all as specified and directed by the Engr-in-charge.
S&F sheet metal enclosure change over switch “ON LOAD” compact design type 415V, AC, 50 Hz of 200 Amps, 4 pole conforming to IS 13947 – 3 including taking down the old one all as specified and as directed.
S&F sheet metal enclosure change over switch “ON LOAD” compact design type 415V, AC, 50 Hz of 100 Amps, 4 pole conforming to IS 13947 – 3 including taking down the old one all as specified and as directed.
S&F sheet metal enclosure change over switch “ON LOAD” compact design type 415V, AC, 50 Hz of 63 Amps, 4 pole conforming to IS 13947 – 3 including taking down the old one all as specified and as directed.
S&F sheet metal enclosure change over switch “ON LOAD” compact design type 415V, AC, 50 Hz of 400 Amps, 4 pole conforming to IS 13947 – 3 including taking down the old one all as specified and as directed.
Supply, Install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS sheet, powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. Necessary foundation work as per manufacturer instructions including foundation and including taking down the old panel required at site and comprising the following :_
INCOMING (a) S&F for Electrolytic grade high conductivity solid 4 Nos Aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification. – 04 Nos. (b) S&F LED Indicating lamps for main Supply indicating ‘R’ ‘Y’ ‘B’ – 01 Set of 3. (c) S&F Ammeter and Voltmeter digital multi meter – 01 No. (d) S&F for MCCB 500 Amps 36 KA, 4 pole Thermal magnetic setting complete – 01 No. (e) Change over switch 250 Amp 4 pole front loaded operated 415 Volts – 01 No. OUTGOING (a) S&F MCCB of 4 pole of capacity 160 Amps, with breaking capacity of 36 KA with fixed thermal and fixed magnetic setting – 01 No. (b) S&F MCCB of 4 pole of capacity 200 Amps, with breaking capacity of 36 KA with fixed thermal and fixed magnetic setting – 01 No. (c) S&F MCCB of 4 pole of capacity 250 Amps, with breaking capacity of 36 KA with fixed thermal and fixed magnetic setting – 01 No. (d) S&F MCCB of 4 pole of capacity 350 Amps, with breaking capacity of 36 KA with fixed thermal and fixed magnetic setting – 01 No. (e) S&F MCCB of 4 pole of capacity 400 Amps, with breaking capacity of 36 KA with fixed thermal and fixed magnetic setting – 01 No.
M&L for cutting of hard road and excavation in trenches not exceeding 1.5m in width and 1.5m in depth and getting out in hard rock/soil complete all as directed by the Engr-in-charge.
M&L for plain cement concrete in 1:2:4 using 20mm graded stone aggregate type B1 as in foundation filling mass concrete measured solid all as directed by the Engr-in-charge.
S&F for gang operated device 11 KV triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 400 Amps complete all as specified and as directed.
S&F for junction box with single pole MCB C series and connection with cable including lugs with cramping tools complete and double clamped with fabricated MS Clamps as directed and fixed out side wall with bolts and nuts including painting and taking down old unserviceable complete all as specified and directed.
Supply and fix for bracket for single street light fitting fabricated with GI pipe medium grade 40mm dia 2m long bend to shape and double clamped with fabricated MS clamps as directed and fixed out side wall with bolts and nuts including painting and taking down old unserviceable complete all as specified and directed.
Supply, fix, test and commissioning LED street light luminaries outdoor type 60 watts new generation energy saving & environmental friendly long life versatile pressrre die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 Hz supply, including provision of two single core 1.5 Sqmm copper conductor PVC insulated, 1100 volts, cable not less than 8 meter long etc, connecting from junction boxes of poles and including taking down the old fittings all as directed by the Engr-in-charge. Make : CG Cat No. TRP-409-60-57-SL-GL-NFG or equivalent to make of Havells, Bajai and Philips..
M&L for painting to steel tubular poles LT of 8.5/9.00/11.00 meter high including fittings and fixtures complete, fixed with one coat of aluminium paint including scrapping of rusts and preparation of surfaces etc., complete all as specified and directed
Supply, fix, test and commissioning LED post top latern luminaries outdoor type 20/25 watts new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 Hz supply, including provision of two single core 1.5 Sqmm copper conductor PVC insulated, 1100 volts, cable not less than 8 meter long etc, connecting from junction boxes of poles and including taking down the old fittings all as directed by the Engr-in-charge. Make : CG Cat No. LPTH-20-CDL or equivalent to make of Havells, Bajai and Philips.
S&F sheet metal enclosed contactor rating 65/TP and MCB rating 63 Amps, digital 24 hour including all internal accessories complete with switch fuse units and fuse carrier of TPN 63 amps, 415 Volts including taking down old unserviceable complete all as specified and directed. Make : Havells Cat No. IHXTSO9120 or equivalent to make of L&T, C&S and Schneider.
S&F steel tubular swaged poles complete with cast iron base plate, final taperplug, bolts, nuts & screws as specified type 410 SP-22, 8.5 metres high including taking up unserviceable pole complete all as specified and as directed. Note: excavation, foundation concrete will be measured and paid separately.
Supply, fix, test and commissioning LED flood light luminaries outdoor type 120 watts new generation energy saving & environmental friendly long life versatile pressrre die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 Hz supply, including provision of two single core 1.5 Sqmm copper conductor PVC insulated, 1100 volts, cable not less than 8 meter long etc, connecting from junction boxes of poles and including taking down the old fittings all as directed by the Engr-in-charge. Make : CG Cat No. LFLN-120-CDL/60-M or equivalent to make of Havells, Bajai and Philips..
S&F garden light 8 watt new generation energy saving & environmental friendly long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LED as light source complete all as specified and as directed by the Engr-in-charge. Make : Havells Cat No. BAMBOOBLS8WLED830PSYMTOPC (1.0Mtr) or equivalent to make of CG, Philips and Wipro.
Supply, fix, test and commissioning LED post top latern luminaries outdoor type 60/70 watts new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 Hz supply, including provision of two single core 1.5 Sqmm copper conductor PVC insulated, 1100 volts, cable not less than 8 meter long etc, connecting from junction boxes of poles and including taking down the old fittings all as directed by the Engr-in-charge. Make : CG Cat No. LPTO-60-CDL-M or equivalent to make of Havells, Bajai and Philips.
S&F in repair of aluminium strip 25 x 3.15mm with DMC fibre insulator and fixing screws etc wall/roof conductors including taking down of unserviceable strip with all accessories complete all as specified and directed. Note: DMC Fibre insulator will be measured and paid separately.
S&F porcelain insulatorsof size 75mm height and 25mm width for fixing aluminium and GI strip with suitable nut, bolts and washers complete all as specified and as directed.
S&F Air termination single pointed aluminium rod 12mm dia 300mm long with suitable nut, bolts, screws, washers & complete including taking down old unserviceable one all as specified and as directed.
S&F bakelite insulator sheet of size 100mm x 100mm x 12mm thick for fixing of air termination with suitable nuts, bolts and washers complete including taking down old old unserviceable one all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorous bronze size 75mm x 75mm x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw complete including taking down old unserviceable one all as specified and as directed.
S&F galvanized iron pipe 40mm dia light grade for protection of lightning conductor laid in floor/fixed in wall with all necessary fixing arrangements etc., complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, earth plate connected to galvanized iron earth strip of size 25mm x 4mm as earthing conductor by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 5 of MES SSR part I (2009) connected to earth test point/ main switch/ DB/ Panel board or any other machinery/equipments all as specified or indicated including testing on completion. Note : The rate quote included for necessary excavation and earth work in any type of soil etc ., and including 32mm bore light grade GI protection pipe for earth strip including PCC (1:3:6) type C1 pit with 50mm thick precast RCC (1:2:4) type B-1 cover reinforced with 8mm dia MS bars @ 100mm c/c both ways with lifting hooks made out of 12mm dia MS bars, 15mm bore wire mesh funnel and copper lugs with GI watering pipe 20mm dia light grade, common salt, charcoal filling in layers as specified, testing on completion in addition to Item No 1(a) to (e) of preamble (Notes) under Sub heading earthing specified in SSR Part – II 2020 complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling rose, pendant, regulator sockets etc., to be measured separately) all as specified and as directed.
INCOMINGM&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multi-stranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non-metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc. including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light point controlled by one switch.
One Fan/ Exhaust fan point controlled by one switch.
One 3 pin 5 amps socket outlet on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch.
One bell/buzzer point controlled by one bell push
One socket outlet 3 pin 15 Amps controlled by one switch independent board with cable 2.5 Sqmm size. (Two run ) and 2.5 Sqmm (one run) all as specified and as directed.
S&F modular switches suitable for type AC 240 Volts, 6 Amps.
S&F modular sockets suitable for type AC 240 Volts, 6 Amps.
S&F modular switches suitable for type AC 240 Volts, 16 Amps.
S&F modular sockets suitable for type AC 240 Volts, 16 Amps.
S&F ceiling rose PVC/ polycarbonate body 65 x 50mm 2 to 3 terminals 230 Volts, AC Single phase all as specified and directed.
S&F electronic ceiling fan step regulator, modular type, 2 module, 120 watts all as specified and directed.
S&F bell push modular type, 1 module flush type, 120 watts all as specified and as directed.
S&F 20 watts LED light fitting, basic all-purpose surface and wall mounted LED batten 20 watt with aluminium housing and integrated electronic driver including 20 watt LED tube fixed on wall or ceiling complete all as specified and directed. Make: Havells Cat No. LHEXTP71N1S022 or equivalent of other makes specified in particular specifications.
S&F 10 watts LED light fitting, basic all-purpose surface and wall mounted LED batten 20 watt with aluminium housing and integrated electronic driver including 10 watt LED tube fixed on wall or ceiling complete all as specified and directed. Make: Havells Cat No. LHEXACP7FN1W010 or equivalent of other makes specified in particular specifications.
M&L for submain wiring complete with two runs of 4.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall along with conduit fittings and accessories, fixed on walls/floors/ceiling with one run of 4.0 Sqmm PVC insulated unsheathed copper conductor cable of green colour as earth continuity conductor and connecting to common earth dolly including taking down old unserviceable sub main wiring complete all as specified. Note: Two runs of 4.0sqmm multistranded cable and one run of 4.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 6.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall along with conduit fittings and accessories, fixed on walls/floors/ceiling with one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable of green colour as earth continuity conductor and connecting to common earth dolly including taking down old unserviceable sub main wiring complete all as specified. Note: Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
S&F MCB distribution board made of 1.2mm thick special CRCA sheet, powder coated with high quality weather proofing paint conforming to IS 13032, double door fixed in switch boards/wall at various places of capacity 240 Volts, 12 way MCB DB, SPN with 200 Amps rated bus bar conforming to IP 38 protection complete including taking down the old unserviceable all as specified and as directed.
S&F MCB Isolator of rating 240 Volts, SPN 63 Amps complete including taking down the old unserviceable all as specified and as directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 32 Amps, 230 Volts complete all as specified and directed.
S&F Electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 Ltr, 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., all as specified and as directed
S&F high speed BEE 5 star rated standard plain ceiling fan of 1200mm sweep (colour as approved by GE) 230V, 50HZ single phase fixed with suitable clamp and down rod (GI Pipe) including drilling, bolts and nuts complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB of rating 240V, 20Amps complete all as specified and directed.
Supply, fix, MCB of single pole of rating 240V, 20Amps, 10KA, 'C' Series in existing MCB DB complete all as specified and directed.
Supply & Fix PVC flexible heavy duty pipe of 15mm dia on wall/floor incl all fittings and fixtures complete for drain out of indoor unit water all as directed.
Supply & Fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation for 170 V to 250 V with output voltage stabilised at 230 V with accuracy of + 2.5% and of capacity 5KVA complete all as specified and directed. Make- V-GUARD/PREMIER
Supply & Fix Air cooled split unit Air conditioner electric driven, single phase of capacity 1.5TR BEE five star rated incl installation of indoor and outdoor unit with cutting hole into brick masonry wall not exceeding 450mm thick built in CM, using drilling machine for inserting 65mm dia PVC heavy duty pipe with provision of necessary clamps, bolts, bracket & nuts for fixing of indoor/outdoor units and making good to the disturbed surfaces and testing complete all as specified and directed. Make- Bluestar/LG/Voltas
Fixing only any type of Ceiling Fan 1200mm sweep complete, connecting the fan to the ceiling rose incl taking down carefully with disconnection from ceiling rose and depositing the fan to E/M Store yard complete all as specified and directed.
Fixing only any type of Exhaust Fan 300mm sweep heavy duty iron body complete, connecting the fan to the ceiling rose incl taking down carefully with disconnection from ceiling rose and depositing the fan to E/M Store yard complete all as specified and directed.
S&F turbo force 4 blade (300mm sweep) exhaust fans AC single phase 230/ 240 volts, heavy duty corrosion resistant body rigid frame with rubber mountings for minimal noise operation & maintenance free design with pressure die cast aluminium rotor mounted on two ball bearings with maximum air with minimum power consumption conforming to IS: 2312-1967 complete all as specified and directed.
S&F for UPS system 850 watts, 230 Volts, 12Volt battery 180 AH with battery terminal and lead including installation complete all as specified and as directed.
EVEREST ENGINEERING WORKS
M/s Jai Ganesh Engineering Solutions
SIRITEL SYSTEMS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .