| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹41.3 L+₹3.8 L (10.2%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹44.9 L+₹7.5 L (19.9%)Rejected-Finance BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹45.9 L+₹8.4 L (22.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | N K BUILDERS L1 | M/s Koul & Sons L4 | GANDOTRA CONSTRUCTION CO L3 | M/S BHAT ENGINEERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs blankets any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge. | 160 | Sqm | 1 ₹160 Lowest | 2 ₹320 | 10 ₹1,600 | 7 ₹1,120 |
| 2.00 | M&L 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls & Ceiling complete all as specified and directed by Engr-in-Charge. | 160 | Sqm | 750 ₹1,20,000 Lowest | 820 ₹1,31,200 | 1,200 ₹1,92,000 | 810 ₹1,29,600 |
| 3.00 | S&F in repair for SDC Laminated flooring 8mm thick of any coloured, manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base, complete including removal of existing flooring, all as directed by the Engr-in-Charge. | 160 | Sqm | 1,290 ₹2,06,400 Lowest | 1,500 ₹2,40,000 | 1,800 ₹2,88,000 | 1,430 ₹2,28,800 |
| 4.00 | Dismantling of timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section frame work complete all as specified and directed by Engr-in-Charge. | 500 | RM | 5 ₹2,500 | 2 ₹1,000 Lowest | 10 ₹5,000 | 2 ₹1,000 Lowest |
| 5.00 | M&L second class hard wood timber scantling plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area exc. 13 Sq cm n.exc 25 Sq cm secured with nails or bradscomplete all as specified and directed by Engr-in-Charge. | 500 | RM | 60 ₹30,000 Lowest | 110 ₹55,000 | 70 ₹35,000 | 79 ₹39,500 |
| 6.00 | M&L second class hard wood timber scantling bull?nosed, splayed,chamfered or rounded on one edge or face, secured with nails or brads, sectional area exc. 3 Sq cm n.exc 6 Sq cm secured with nails or brads complete all as specified and directed by Engr-in-Charge. | 60 | RM | 30 ₹1,800 Lowest | 75 ₹4,500 | 70 ₹4,200 | 45 ₹2,700 |
| 7.00 | Taking down chowkhats or frame exc 1.50 sqm each but n exc 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engr-in Charge. | 3 | Each | 100 ₹300 | 30 ₹90 Lowest | 50 ₹150 | 46 ₹138 |
| 8.00 | S&F 2nd Class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed. | 0.02 | Cum | 40,000 ₹800 | 90,000 ₹1,800 | 50,000 ₹1,000 | 30,000 ₹600 Lowest |
| 9.00 | S&F 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engr in Charge. | 3.78 | Sqm | 2,500 ₹9,450 | 1,600 ₹6,048 Lowest | 3,000 ₹11,340 | 3,300 ₹12,474 |
| 10.00 | M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed by Engr-in-Charge. | 10 | Sqm | 80 ₹800 | 55 ₹550 | 50 ₹500 Lowest | 90 ₹900 |
Tender Value
₹46.2 L
EMD Value
₹92,440
Closing Date
25 Sept 2025, 6:00 pmClosed
GE 860 EWS
GE 860 EWS Karu Pin-194201
SPECIAL E/M REPAIR TO OLD UNSERVICEABLE LT PANELS, LT CABLES AND CONNECTED ITEMS AND SPL REPAIR TO BLDG NO. T-186 AT KARU AREA UNDER GE 860 EWS
2025_MES_728308_1
8192/2025-26/E8
Open Tender
Civil Works
Item Rate
270 days
KARU
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS Karu
₹92,440
Yes
13 Oct 2025
29 Aug 2025
27 Sept 2025
29 Aug 2025
25 Sept 2025
12 Sept 2025
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs blankets any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge.
M&L 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls & Ceiling complete all as specified and directed by Engr-in-Charge.
S&F in repair for SDC Laminated flooring 8mm thick of any coloured, manufactured by Direct Pressure Laminated (DPL) wherein the empty Abrasive aluminium oxide overlay alongwith metamine impregnated decorated film is directly fused with the back with flooring locking profile in designed with double click locking system on the length and single locking width alongwith desire locking strength laid over 1mm thick foam base, complete including removal of existing flooring, all as directed by the Engr-in-Charge.
Dismantling of timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section frame work complete all as specified and directed by Engr-in-Charge.
M&L second class hard wood timber scantling plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area exc. 13 Sq cm n.exc 25 Sq cm secured with nails or bradscomplete all as specified and directed by Engr-in-Charge.
M&L second class hard wood timber scantling bull?nosed, splayed,chamfered or rounded on one edge or face, secured with nails or brads, sectional area exc. 3 Sq cm n.exc 6 Sq cm secured with nails or brads complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frame exc 1.50 sqm each but n exc 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engr-in Charge.
S&F 2nd Class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
S&F 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engr in Charge.
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engr-in-Charge.
S&F 200mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed by engr in charge
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engr-in-Charge.
S&F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal/wooden frame including punching or drilling out old glazing pins/spring clips complete all as specified and directed by Engr-in-Charge.
Supply and fixing 3mm sheet glass thick ordinary quality and glazing with oil putty in squares n. exc 0.5 Sqm in each pane complete all as specified and directed by Engr-in-charge.
Demolition of Cement Concrete (Unreinforced) in ground floors and pavings n exc. 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge.
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.16 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in CM 1:4 all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (using 20mm graded crushed stone aggregate) as in floor plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC (1:3:6) type C2 (Using 20mm graded crushed stone aggregate) as in floor levelling without using extra cement complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof covering and wall cladding complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
Dismantling wrougth iron or mild steel work of any description not otherwise provided as specified as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and directed by Engr-in-Charge.
M&L preparation of steel Surfaces new untreated surface apply one coat of red oxide,zink chrome and two coat of synthetic enamel (ordinary tint) paint any description, over 10cm in width or girth,not otherwise described complete all as specified and directed by Engr-in-Charge.
S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engr-in-Charge.
M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry with screed bed 15 mm thick 1:4 and pointed in white or colour cement and match the surace of tiles as foor/staps, complete as all specified and directed.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
M&L point wiring complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casing and capping of 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl surface PVC Boxes of suitable size fixes with wall surface, Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for the following:-
One light / bell / buzzer / exhaust fan point controlled by one no, 1-way, 5 Amps switch.
One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
Description all as per srl item No. 32.00 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
S&F, in repalcement, of Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed.
S&F, in repalcement, of Switch Socket combination, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, complete all as specified and directed.
S&F, in repalcement, of Switch Socket combination, 6 pin, 5/15 Amp, multipurpose shutter type, 230 volts, complete all as specified and directed.
S&F, in repalcement, of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as directed by Engr-in-Charge at site including necessary fixing arrangement like bracket, clamps and nuts and bolts complete all as specified and directed by Engr-in-Charge.
S&F in replacement Lamps Holder PVC/ polycabonate by with back plate angular type complete all as specified and directed by Engr-in-Charge.
S&F LED bulb 9W for fixing with lamp holder complete all as specified and directed by Engr-in-Charge.
S&F in replacement exhaust fans made of sturdy Engineering plastic AC single phase 230/ 240 V of size 250 mm sweep with louvre complete in cluding making hole in the wall and making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
S&F in replacement of DB, Single Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
S&F in replacement of MCB, C Curve type, 10 kA, 40 to 63 Amp, SPN with over load and short circuit protection, complete all as directed.
S&F in replacement of MCB, C Curve type, 10 kA, 6 to 40 Amp, Single Pole with over load and short circuit protection, complete all as directed.
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 16 Sqmm, 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-Charge.
Excavation in trenches not exceeding 1.5m and not exceeding 1.5m in depth for laying of electric cable and getting out in hard and dense soil, complete all as specified and as directed by the Engr-in-Charge.
Returning, filling in excavated soil, including leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by the Engr-in-Charge.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engr-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge. Note:- Only punned thickness shall be measured and paid.
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
Laying only old reinforced PCC cable cover of any size as retrieved from serial item No. 53.00 here in before complete all as directed by Engineer-in-Charge.
S&F galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 185 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
Description all as Srl item No. 57.00 here in before but for cable size of 150 sqmm 3.5 core.
Description all as Srl item No. 57.00 here in before but for cable size of 120 sqmm 3.5 core.
Description all as Srl item No. 57.00 here in before but for cable size of 70 sqmm 3.5 core.
Description all as Srl item No. 57.00 here in before but for cable size of 50 sqmm 3.5 core.
Description all as Srl item No. 57.00 here in before but for cable size of 35 sqmm 3.5 core.
Description all as Srl item No. 57.00 here in before but for cable size of 25 sqmm 4 core.
Description all as Srl item No. 57.00 here in before but for cable size of 16 sqmm 4 core.
Description all as Srl item No. 57.00 here in before but for cable size of 10 sqmm 2 core.
Taking out old UNSV LT panel board / Junction box of any size complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 No (I/C) (b) MCCB 4 pole, 200 Amps, 415 Volt, AC ,25 KA = 01 No (O/G) (c) MCCB 4 pole, 160 Amps, 415 Volt, AC, 16 KA = 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts = 10 Nos (O/G) (d) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS 485 Make : L&T
(e) Phase indicating lamp = 03 Nos (R, Y, B) (f) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (g) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 16 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA= 03 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T
(f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (h) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 160 Amps, 415 Volt, AC ,16 KA = 01 No (I/C) (b) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA= 02 Nos (O/G) (c) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G)
(d) Aluminium bus bar of capacity 200 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (e) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
(f) Aluminium bus bar of capacity 200 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four (g) Panel drawing shall be got approved from GE before placing order. Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 25 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
M/S BHAT ENGINEERS (BID ID -3429421)
GANDOTRA CONSTRUCTION CO (BID ID -3429094)
M/s Koul & Sons (BID ID -3428937)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .