Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹46.5 L+₹7.2 L (18.2%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹48.5 L+₹9.2 L (23.4%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.3 L+₹10.0 L (25.5%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.5 L+₹10.2 L (26.0%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) CHABUA
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
As per BOQ
2024_MES_649301_1
537/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(AF) CHABUA
As per tender documents
7 documents required · 7 mandatory
₹500
GE(AF) CHABUA
₹80,000
Yes
10 May 2024
5 Apr 2024
29 Apr 2024
5 Apr 2024
27 Apr 2024
20 Apr 2024
Amount
Taking down Old burnt /Unserviceable 4 core 16 Sqmm underground XLPE Cable aluminum conductor LT 1100 V grade after disconnecting of electric connection complete all as specified and directed at site.
All as per ser item No 01 above but Size of cable 25/35 Sqmm X 3.5 core
All as per ser item No 01 above but Size of cable 50/70 Sqmm X 3.5 core
All as per ser item No 01 above but Size of cable 95/120 Sqmm X 3/3.5 core
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs of size 16 sqmm x 4 core complete all as specified and directed.
All as per ser item No 05 above but Size of cable 25 Sqmm X 4 core
All as per ser item No 05 above but Size of cable 35 Sqmm X 3.5 core
All as per ser item No 05 above but Size of cable 50 Sqmm X 3.5 core
All as per ser item No 05 above but Size of cable 70 Sqmm X 3.5 core
All as per ser item No 05 above but Size of cable 95 Sqmm X 3.5 core
All as per ser item No 05 above but Size of cable 120 Sqmm X 3.5 core
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and directed.
Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreating with PCC 1:3:6 to match with the adjescent surfaces complete all as specified and directed.
Supply and fix in repair steel tubes, galvanised, light grade, ISI marked 40 mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Supply and fix in repair steel tubes, galvanised, light grade, ISI marked 50 mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Supply and fix in repair steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 2/4 core XLPE, armoured, Al conductor cable of size 10 to 16 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type for joininng of damaged cablecomplete all as specified and directed.
M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing 40 to 80mm bore complete all as specified and directed.
S&F in replacement of MCCB, 4P, 250 Amps, 36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate complete all as specified and directed.
S&F in replacement of MCCB, 4P, 200 Amps, 36 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate complete all as specified and directed.
S&F in replacement of MCCB, 4P, 160 Amps, 36 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate complete all as specified and directed.
S&F in replacement of MCCB, 4P, 100 Amps, 16 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate complete all as specified and directed.
S&F in replacement of MCCB, 4P, 63 Amps, 16 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate complete all as specified and directed.
S&F in repair load changeover switch four pole of 200 Amps, 415 volts, 50 Hz in SS enclosure complete all as specified & directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates.
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on LT/HT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting/trimming of tree branches upto 2 mtr clear distance from wire, complete all as specified and directed.
M & L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, complete all as specified and directed.
Supply and stringing in repair ACSR conductor of any size for LT/HT over head line as directed including fixing to insulators with proper size of binding wire complete all as specified and directed.
Supply and fix in repair GI wire of 4 mm dia including fixing of insulator on suitable length complete all as specified and directed.
Supply and fix in repair pin type, porcelain, vitreous, white brown or green insulator including one galvnised mild steel spindle, two nos galvanised iron washer and one galvnised iron nut, 100 mm height, 65 mm dia for 1100 v grade complete all as specified & directed.
Supply and fix in repair shackle, porcelain, vitreous, white brown or green insulator including galvnised mild steel straps, washers, insulator, bolts, washers and nuts for size 100 mm height and 115mm dia for 1100 Volts with 31x5 mm galvanised steel straps and 14 mm dia of bolts complete all as specified and directed.
M&l for painting of any types of LT poles up to 9 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos all as specified and directed at site.
S&F in repair voltmeter digital type 0-500 volts AC, flush mounting type, 3 phase complete all as specified and directed.
S&F in repair ammeter digital type, flush mounting type, 3 phase complete with suitable CTs of range as required on sitecomplete all as specified and directed.
S&F in repair CTs of range 400/5Amps as required on site complete all as specified and directed.
S&F in repair LED indicator as per colour scheme (Red/Yellow/Blue/Green) suitable for LT panel complete all as specified.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug,bolts, nuts, washer and screws including painting with two coats of of aluminium paints over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete all as specified and directed. Note - Earthwork and PCC shall be measured and paid seperately under respective items complete all as specified and directed.
Supply and fixing in repairs mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part-I 1991 complete all as specified and directed. Note: PCC shall be measured and paid seperately under respective item.
M&L for repair/ maintenance of LT panel door by replacement of hinges and locking arrangement including necessary welding/ nuts, bolts, washers as per existing size/ type complete all as specified and directed. Note: (i) One side door will be measured & paid as one job. (ii) New LT panel door (only) of suitable size and thickness shall be measured and paid separately under relevant item of this schedule.)
Supply and fixing in replacement of Aluminium busbar of suitable capacity in any shape and size as required on site complete all as specified and directed.
Supply and fix in repair pin type, porcelain, vitreous, white brown or green insulator including one galvnised mild steel spindle, two nos galvanised iron washer and one galvnised iron nut, 150 mm height, 150 mm dia for 11000 v grade complete all as specified & directed.
M&L for replacement of disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 11000 volts complete all as specified and directed.
Supply and fixing in repair steel tubular pole, swaged, complete with cast iron base plate, finial taper plug,bolts, nuts, washer and screws including painting with two coats of of aluminium paints over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-55 (11 meter long) complete all as specified and directed. Note- Earthwork and PCC shall be measured and paid seperately under respective items.
Disconnecting the distribution transformer outdoor/ indoor type from HT and LT side, opening carefully at site, draining out transformer oil (keeping safe in barrel for reuse) upto HT/ LT box for rectifying the leakage by replacing the unserviceable spare parts of capacity 125 to 315 KVA, 11/ 0.433 KV transformer, refilling the transformer oil and re-assembling after repair including testing for any oil leakages and connecting the HT/ LT side and testing on available electric load complete all specified and directed by Engr-in-Charge. Note:- (a) Defective parts shall be measured and paid separately as "Supply only". (b) Charge of welding work (if require) is deemed to be included in the quoted rate. (c) Connection sleeves, insulated plates, nut, bolts & washers etc (if required) is deemed to be included in the quoted rate.
Supply only Tap changer assy suitable for 125 KVA to 315 KVA Transformer
Supply only HT side bushing with brass stud suitable for 125 KVA to 315 KVA Transformer
Supply only LT side bushing with brass stud suitable for 125 KVA to 315 KVA Transformer
Supply only Transformer top cover gasket/cock sheet suitable for 125 KVA to 315 KVA transformer
Supply and fix in replacement of air breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with new silica gel (blue in colour) suitable for 125 to 315 KVA, 11/ 0.433 KV transformer, fixing on existing pipe of size 15/20/25 mm dia with suitable reducer/ connector complete as per site requirement all specified and directed by Engr-in-Charge. Note:- (a) Cost of modification (if required to fix on existing MS pipe) shall be deemed to included in the item quoted rate complete all as specified and directed.
Supply and fix in replacement of danger notice plate of 1.6 mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull & bones in signal red colour & fixed with & including MS clamps, bolts, nuts and of size 25 x 20cm for HT 11KV complete all specified and directed.
S&F in replacement of anti climbing devices comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as directed by Engr-in-Charge. Note:- (a) Clamps required shall be measured seperately
S&F in replacement of anti-climbing device spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole or as ordered complete all as specified and directed.
Supply and filling silica gel complete all as specified and directed.
Supply and fix in repair oil level indicator suitable for 125 to 315 KVA, 11/ 0.433 KV transformer alongwith connected accessories complete all specified and directed by Engr-in-Charge.
Material and labour for painting of any type pole of HT over head line of 11 m long (except embedded portion) complete including all MS work mounted on pole with two coat of aluminium paint after necessary preparation, cleaning including scrapping up of old corroded paint dirt/ dust/ rust carefully and providing 03 Nos bands/ straps with synthetic enamel paint (any tint 30 cm wide each) from top of plinth block and writing of pole number with white synthetic enamel paint on black back ground complete all as specified and directed by Engr-in-charge.
Material and labour, painting of two pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour, painting of four pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate for fdn of pole/ stay/ angle/ pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for fdn of pole/ stay/ angle/ pipe complete all as specified and directed.
M&L for PCC 1:2:4 type C2 using 20mm graded for padestal coping including necessary form work finished fair using extra complete all as specified and directed.
M & L for rewinding HT/LV coils of transformer by using proper size super enameld copper wire suitable for working voltage 11 KV/0.433 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed at site. NOTE :- i). Oil filtration,supply of new oil will be measured separately. ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted. iii). The rate for taking out,refixing after repair,both side transportation, lifting /unloading of voltage stabilizer/isolation transformer by crane /manual should be deemed to include in the rate quoted.
M&L for dehydration & filteration of transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed by Engr-in-charge. Note: (a) The filtration of the transformer oil shall be carried out at different sub stations of doom dooma. (b) The report before filtration & after filtration to be submitted by contractor. (c) Transformer oil for topping up will be measured and paid separately.
Supply & toping up of new transformer oil (in sealed barrel) confirming to IS 335 Std having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified. Make: Savita/ Castrol/ Power oil/ Truoil.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of 125 KVA to 315 KVA transformer (11/0.433KV) complete with all connected fittings & fixtures i.e. buchholz relay, conservator tank, cooling fins and other standard fittings & attachments as per existing colour scheme and pattern with atleast two coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction of Engr-in-Charge complete all as specified. Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates.
S&F in repair gang operated air break switch triple pole, mechanically manual operated, mounted on 9 Nos insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 Amps, 11000volts complete all as specified and directed.
M&L for drop out fuse single pole suitable for 11000 volts grade complete all as specified and directed.
S&F in replacement of lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, 11000 volts complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
M&L for earthing with copper earth plate electrode 60 cm x60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.5 mtr below normal ground level ) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to main earth copper strip 32 x 6 mm as earth lead by means of bolts ,nuts,check nuts and washers of brass or copper as shown in electrical plate No. 3, including exc , and earth work in any type of soil disposal of soil providing alternate layers of charcol and common salt construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick 1:2:4 type B-1 cover reinforced with 8 mm dia MS bars both ways with lift hook made out of 8 mm dia bar,watering arrangement. Note : Main earth lead beyond 7.5 meter shall be measured and paid saperatly. Taking down old unserviceable dilapidated copper earthing are included in quoted rate.
Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes,cable laying, sewage/water lines etc complete all as specified and directed.
Excavation in trenches in soft/loose soil, n.exc 1.5 m wide and exc 1.50m but n.exc 3.0 m in depth for foundation or shafts, wells cesspit, manholes, pier holes,cable laying, sewage/water lines etc complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
M&L sub class B brick,well burn laid bridth-wise along the length the cable laid in trench over sand cushion,laid for ug cable protection complete all as specified and directed at site.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 mmx 180 mm x 40 mm laid in trenches as cable covers complete all as directed.
Dismantling/taking down carefully defective any type LED street light/security light/ flood light light fittin from pole/structure/bldg from any height and repair/checking and identifying of faulty spares, wrings, cleaning of fittings,cover etc and reassembling the same after repair,testing and refixing in original position and reconnecting with the electrical line complete all as directed by Engr-in-Charge.Note : (i) Materials required for replacement such as driver,wires, etc will be measured and paid separately under relevant items. (ii) If E-N value on security feeder is high,it should be checked and rectified without extra claim.
Supply and fix in repair LED driver suitable for 45 watt LED street light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 60 watt LED street light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 100 watt LED flood Light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 150 watt LED flood Light fitting complete all as specified and directed.
S&F in repair LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 45 W capacity after taking down the old unserviceable one complete all as specified and directed .
S&F in repair LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 60 W capacity after taking down the old unserviceable one complete all as specified and directed .
Supply and fix in repair post top lantern fittings and supply & fixing post top luminaire LED type of 25 W of post top lantern with aluminium die-cast housing cum heat sink in IP-65 protection including all fixinging arrangement complete all as specified and as directed,
Supply and fix in repair, 8 watts LED bolards light IP-65 protection, resistant to corrosion better optics for uniform distribution including all fixing arrangements complete all as specified and as directed.
S&F in repair flood light fitting mounted on high mast light of 100 watt energy saving,environmental friendly,long life,made up of pressure die-cast aluminium housing with toughened glass and high power LEDs IP66 protection,suitable for highlighting architectural facade and general purpose lighting after taking down the old unsv one complete all as specified and directed.
S&F in repair flood light fitting mounted on high mast light of 150 watt energy saving,environmental friendly,long life,made up of pressure die-cast aluminium housing with toughened glass and high power LEDs IP66 protection,suitable for highlighting architectural facade and general purpose lighting after taking down the old unsv one complete all as specified and directed.
Supply and fix in repair cable junction box IP 66 weather proof for outdoor installation (with metric knockouts for cable entry) size 205 x 255 x 112 mm suitable for 16/25 sqmm cable fixed to pole/ wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No MCB, single pole, 240 volts, 10 KA 10 Amps, and suitable aluminium bus bar/ connector complete all as specified and directed.
Supply and fixing in replacement of PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, 1100 volts grade, three core of copper conductor for connection of street light/ flood light/ post top lantern/ garden lights etc. fittings on pole/ wall/ pillar/ from over head conductor / junction box / DB including termination clip complete in all respect complete all as specified & directed.
S&F in repair automatic nature timer (based on lux level of natural light) based street light panel 3phase, 12-18kW, IP66 with in-built nature switch, power contactor, incoming & outgoing 40A TP MCB, pole/ wall mounted type, thermoplastic polymer weather proof enclosure, internal connecting cables complete all as specified and directed. Make : Nature Switch/ Havells/ Legrand or as approved by GE.
Taking down old unsv UG cable of size 16 sqmm x 2 cor complete all as specified and as directed at site.
Supply and laying in trenches or drawn through pipe or fixed on wall/poles, LT UG cable heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor of size 16 sqmm x 2 core complet all as specified and as directed at site.
Supply and fix street light GI bracket,bend to 120 degree angle,made out of 40 mm bore,gI pipe,light grade (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts,bolts and washers etc and two coat of synthetic enameled paint over a coat of red oxide primer including taking down the old rusted one complete all as specified and directed.
S&F in replacement of MCB SP 240 volt 6 to 32 Amps 'C' series 10 KA complete all as specified and directed at site.
Carrying out routine, preventive maint & servicing of 380 KVA DG set Make: Cumins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center/ auth service center of OEM periodicaly or on requirement basis and replacement of unserviceable spare parts/ accessories including calibration of control devices/ refitting of serviceable parts after cleaning/ servicing including minor consumables accessories like cotton, waste cloth, kerosene oil etc including draining of oil dust from foundation/ base plate complete all as specified and directed for the following under mentioned DG set:- (a) Check clearance of suction and exhaust valves including adjust, if required. (b) Changing of oil filter, fuel filters, water filter,screen filters assy, air filter etc. (c) Topping up of coolant & changing of hydraulic governer oil. (d) Tightening of all nut bolts including greasing of all points. (e) Checking of any leakage in fuel tank and oil lines. (f) Adjusting valve tappet clearance/timing, injector pressure test, cleaning and repairing,tightining fasteners and making lubrication leak proof. (g) Repair/ rewiring of broken/ damaged control panel connection including measuring instruments, indicators, engine protection devices etc. Note . (i): Labour charges for dismantling/ taking down and replacement/ refixing parts as and when required is deemed to be included in unit item quoted rate. (ii): Spare parts like oil filter, fuel filter, water filter, screen filter by pass filter, air filter etc will be measured and paid separately.
All as per ser item No 98 here-in-before but Cap of DG Set 200 KVA
Supply only disel filter suitable for 380 KVA DG set complete all as specified and directed at site.
All as per ser item No 100 here-in-before but Cap of DG Set 200 KVA
Supply only oil filter suitable for 380 kVA DG set complete all as specified and directed at site.
All as per ser item No 102 here-in-before but Cap of DG Set 200 KVA
Supply only air filter suitable for 380 kVA DG set complete all as specified and directed at site.
All as per ser item No 104 here-in-before but Cap of DG Set 200 KVA
Supply only Water Separater suitable for 380 kVA DG set complete all as specified and directed at site.
All as per ser item No 106 here-in-before but Cap of DG Set 200 KVA
S&F in replacement battery terminal cable, copper conductor with brass adaptor at both side of end point, multistrand, unsheathed, single core, 25 Sqmm, 1100 volts grade in length of 1.5 mtr long suitable for 12 Volts & upto 180 AH battery. Complete all as specified and directed.
De-scaling of radiator assembly by carefully from the engine,transporting to civil workshop and removing the sediments,scales and rust etc by means of chemical cleaning,high pressure water washing and air cleaning, arresting the leakages by gas welding/soldering with suitable material, and re-assembling the same with new gaskets including replacement of radiator cap(whereever required) and transporting to the site, fixing to the engine for DG set of capcity 380 KVA and testing for satisfactory performance complete all as specified and directecd at site.
All as per ser item No 109 here-in-before but Cap of DG Set 200 KVA
Calibration of FIP including replacement of barrel plunger,cups & 'O' rings etc suitable for 320 KVA DG Set complete all as specified and directed at site.
All as per ser item No 111 here-in-before but Cap of DG Set 200 KVA
Supply and fix in repair AVR as per existing model suitable for 380 KVA DG Set complete complete all as specified and directed.
Supply and fix in replacement AVR as per existing model suitable for 200 KVA DG Set complete complete all as specified and directed.
Supply and fixing SMPS electronic battery charger 24 v, 10 amps complete with all connecting accessories and connecting wire all as specified and as directed.Note : Chrger shall be fixed in existing panel
Material and labour for cleaning of fuel tank of 380 kVA DG Set by taking out diesel in separate container, tank out of DG set, cleaning & removing all dirt/ sluge/ mud, dust, washing with fresh water thoroughly, drying and fixing back to its original location including making of all connection and re-filling of diesel in tank complete all as specified and directed.
All as per ser item No 116 here-in-before but Cap of DG Set 200 KVA
Supply and filling lubricant oil 15 w 40 for topping up/replacement in engine chamber complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Supply & topping up heavy duty concentrate/ anti freeze radiator premixed coolant complete all as specified. (Make-HP/ Servo/ Castrol)
Supply & topping up distilled water for batteries complete all as specified and directed.
Supply and fixing in replacement of maintenance free battery with initially charged of capacity 180 AH, 12 volt complete all as specified and directec at site.
Dismantling the defective water pump assembly and supply and fix new water pump assembly suitable for existing 320 KVA DG set complete all as specified and directed at site.
Dismantling the defective water pump assembly and supply and fix new water pump assembly suitable for existing 200 KVA DG set complete all as specified and directed at site.
Supply and fixing oil temp sensor suitable for DG set suitable for 380 KVA complete all as specified and directed at site.
Supply and fixing in repair solenoid coil suitable for DG set of capacity 200 KVA complete all as specified and directed at site.
Supply and fix in replacement self starter assembly 24 volt suitable for 380 KVA DG Set complete all as specified and as directed.
S&F in repair fuel pipe suitable for 200/380 KVA DG set complete including clip all as specified and directed.
S&F in repair V belt suitable for 380 KVA DG set all as specified and directed.
S&F in repair V belt suitable for 200 KVA DG set all as specified and directed.
Supply and fix in repair turbocharger suitable for 320 KVA DG Set complete all as specified and directed at site.
Supply and fix in repair bellow suitable for 200 KVA DG Set complete all as specified and directed at site.
M&L for taking out self starter 24 volt from the DG set capacity up to 320 KVA , transportation to civil workshop and opening/ disconnecting all internal connection, cleaning the same taking out burnt armature, segrigation of serviceable parts for re-use, rewinding of armature with copper wire of existing size, assembling all parts, testing & fixing back to the DG set complete all as specified and directed by Engr-in-Charge.
M&L for finding out defects of fully automatic mains failure panel (AMF) of DG set of capacity upto 320 KVA and taking out burnt inter connection wiring including u/s and serviceable components for reuse and rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut, bolt, washer of various sizes, refixing serviceable items including replacement of contactor with auxiliary coil and testing complete for proper functioning complete all as specified.
All as per ser item No 133 here-in-before but Cap of DG Set 200 KVA
Servicing of Main LT Panel-1 Technical Area & main LT Panel -2 D Block non Comprehensive Contactor Servicing with Bus bar Tightness & Insulation Sleeve Checking & Interlocking Logical Testing Charge and the the under mention scope of wrok for Air Circuit Breaker Service is as under aloso carried out Note : Spare parts shall be measure air breaker service id paid and saperately. (i) Visula inspection of components of contactor & ACB to asses condition. (ii) Cleaning of contactor & ACB with CRC 2-26 cleaner. (iii) Removal of old grease and re grease (iv) Check the condition of arching contact and gap (v) Checking protection release parameters and testing of release (vi) Checking presence of all Cir Clips (vii) Checking condition of Contactor & ACB wiring (viii) Checking proper closing of all poles by taking impression etc (ix) Checking condition of Arc Chutes (x) Checking contactor Opening through Y/O coil (xi) Checking contactor closing through Y/C coil (xii) Checking Contactor Opening through U/V coil (xiii) Setting of release as per the load or as per customer requirement (xiv) Checking main operating mechanism and replacing it in case of any failure
Installing of S7 1200 PLC programming & Automation Charge on Technical area & D Block
Supply only Under/Over Voltage relay with phase loss Protection Relay Make : L&T
Supply only Auxiliary Relay 4c/o with Base 230 v AC Make : Omron
Supply only Illumination Push Button Green 24 v DC Make Esbee GIC L&T with 1 Nc
Supply only Illumination Push Button Green 230 v AC Make Esbee GIC L&T with 1 No
Supply only Battery Charger transformer inbuilt 230/24v 10 A Make Mahamai
M&L preparation of steel and iron surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
Cutting and trimming of branches n.exc 50 mm dia in size obstructing lumination of street Light and touching of LT/HT Pole up to a grith of 3 mtr in both side along the conductors as per direction by Engr-in-Charge.
Cleaning around any E/M installations/ pole structures including removing all grass, creepers and other vegetations with roots on soil, hard standing and on chain link fencing complete all as directed and removing the rubbish to a distance not exceeding 50 mtr and depositing where directed.
Description of Work / Item(s)
Amount
Taking out voltage stabilizer by disconnecting existing cable for u/s stabilizer of upto 5 KVA capacity including repairing/replacement of push on switch,relay transistor,diode,voltmeter,indicator lamp, high low cutout complete parts alongwith testing and commissioning and tranportation charges from site to workshop and back complete all as specified and as directed at site.
Supply and fix in repair brass service valve 1/2" dia complete all as specified and directed at site.
Supply and fix in repair brass service valve 1/4" dia complete all as specified and directed at site.
Supply and fix in repair copper pipe 1/2" dia suitable for 1.5 ton Ac complete all as specified and directed at site.
Supply and fix in repair copper pipe 1/4" dia suitable for 1.5/2 Ton Ac complete all as specified and directed at site.
Supply and fix in repair copper pipe 5/8" dia suitable for 2 Ton AC complete all as specified and directed at site.
Supply and fix in repair factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket of 20 amps capacity complete all as specified and directed at site.
S&F in repair MCB SP 240 volt 6 to 32 Amps 'C' series 10 KA complete all as specified and directed at site. Make : Havells/Legrand /Schneider
S&F in repair, insulation tube (size 1/4''/1/2'') for split type Ac to insulation copper pipe complete all as specified and directed at site.
Supply and fixing in repair heavy duty AC stand /outdoor unit mounting bracket suitable for 1.5/2 Ton AC including PCC and masonry work complete all as specified and as directed.
Supply and fix in repair 5 kVA Single Phase 230 Volts 50 Hz Voltage stabilizer suitable for 1.5/2 Ton split/window type AC , working range 130 - 280 V,time delay system complete all as specified and directed at site.Make : V-Guard/Microtek/BLUELAND Note : Old unsv voltage stabilizer to be deposited to MES store yard.
Disconnecting from socket outlets split type/Window type AC of capacity upto 2 Ton of any brand,servicing by dusting,cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing,adjusting and rectifying faulty operation of electrical and electronic remote control panels,replacing of perished electrical wires for proper connection from voltage stabilizer,reinstalling the units to its original positions,replacement of remote cell and complete all as specified and as directed at site. Note : Spare parts shall be measured & paid saperately under relevant items.
All as per ser item No 11 here-in-before but 4 TR castle type/tower type/package type AC complete all as specified and directed at site
Supply and fix in repair filter strainer (copper) suitable for 1.5/2 ton window/Split type AC complete all as specified and directed at site.
Supply and fix in repairs 1.5 Ton split Ac out door fins type condenser complete all as specified and directed at site.
Supply and fix in repairs 2 Ton split Ac out door fins type condenser complete all as specified and directed at site.
Supply and fixing in repair capacitor 50+6 mfd suitable for 2 Ton AC complete all as specified and directed at site.
Supply and fixing in repair blower fan motor suitable for 2 Ton split type AC complete all as specified and directed at site.
Supply and fixing in repair blower fan motor suitable for 1.5 ton split type AC complete all as specified and directed at site.
Supply and fixing in repair blower fan motor suitable for 4 Ton castle/tower type complete all as specified and directed at site.
Supply and fixing in repair outdoor unit fan motor suitable for split type AC upto 2 ton complete all as specified and directed at site.
Supply and fixing in repair Swing motor of lower shutter suitable for split type Ac upto 2 Ton capacity complete all as specified and directed at site.
Supply and charging of refrigerant R-22/R410/R-134 complete all as specified and directed at site.
Supply and fixing in repair PCB board suitable for 1.5 ton split type AC complete all as specified and directed at site.
Supply and fixing in repair indoor PCB board suitable for 2 ton split type AC complete all as specified and directed at site.
Supply and fixing in repair outdoor PCB board suitable for 2 ton split type AC complete all as specified and directed at site.
Supply and fix in repair indoor PCB board suitable for 4 ton castle type/Tower type AC complete all as specified and directed at site.
Supply and fix in repair outdoor PCB board suitable for 4 ton castle type/Tower type AC complete all as specified and directed at site.
S&F in repair compressor unit including necessary charging the system suitable for Window/Split type AC 1.5 Ton Capacity. Note : The rate quoted by the tendred shall be inclusive of cost of refrigerant Gas the charging Gas (R 22/R410/134A) as required for the cooling appliances.
S&F in repair compressor unit including necessary charging the system suitable for Window/Split type AC 2 Ton Capacity.Make : Hitachi/Daikin/Lloyd Note : The rate quoted by the tendred shall be inclusive of cost of refrigerant Gas the charging Gas (R22/134A) as per site requirement for the cooling appliances.
S&F in repair compressor unit including necessary charging the system suitable for 4 ton castle/tower type AC Note : The rate quoted by the tendred shall be inclusive of cost of refrigerant Gas the charging Gas (R22/R410/134A) as per site requirement for the cooling appliances.
Taking down carefully u/s electronic PCB board at existing 1.5 ton/2.0 Ton AC , repair and refixing the same complete all as specified and directed at site.
Taking down carefully u/s electronic PCB board at existing 4 TR Castle/Tower Type AC , repair and refixing the same complete all as specified and directed at site.
Supply and fix in repair display board for upto 2 Ton AC complete all as specified and directed at site.
Supply and fix in repair Sensor for indoor unit upto 2 Ton AC complete all as specified and directed at site.
Supply and fix in repair remote control for split/window type AC cap up to 2 ton complete all as specified and directed at site.
FREEZCON
STANDARD ELECTRIC WINDERS
J D construction
M/s HALDER ENTERPRISE
M/S S. P. ENTERPRISE
MAA COMMUNICATION
M/S MAHATO ENTERPRISE
FREEZCON
STANDARD ELECTRIC WINDERS
M/S S. P. ENTERPRISE
M/s HALDER ENTERPRISE
J D construction
MAA COMMUNICATION
M/S MAHATO ENTERPRISE
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .