| 1 | L1₹15.0 LAccepted-AOC AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.6 L+₹17,586.72 (1.14%)Rejected-Finance AT AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.6 L+₹19,719.58 (1.28%)Rejected-Finance AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹15.7 L+₹31,620.52 (2.05%)Rejected-Finance AT DUNGAMAL NH 5 POST NB CHILKA VIA BALUGAON DIST KHURDA ORISSA 752037 | KHORDHA | ODISHA | 752037 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹16.0 L+₹55,815.22 (3.62%)Rejected-Finance AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | SAHADEV PALAI L6 | HARI HARA NAYAK L4 | PRADIPTA KUMAR PANI L3 | BLV SYNDICATE L5 | PABITRA MOHAN PARIDA L8 | ANTARYAMI PANDA AND COMPANY L7 | M/S SOMANATH ENTERPRISES L9 | D RAVICHANDRAN L1 | VAIKUNTHA PARIDA L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 M in wide and not exc. 1.5 M in depth for taking out or laying of under ground cable in soft / loose soil complete all as specified and as directed. | 146.7 | Cum | 295 ₹43,276.5 | 287 ₹42,102.9 | 285 ₹41,809.5 | 293 ₹42,983.1 | 370 ₹54,279 | 300 ₹44,010 | 320 ₹46,944 | 280 ₹41,076 Lowest | 285 ₹41,809.5 |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and as directed. | 130.56 | Cum | 82 ₹10,705.92 | 75 ₹9,792 | 73 ₹9,530.88 | 80 ₹10,444.8 | 105 ₹13,708.8 | 85 ₹11,097.6 | 80 ₹10,444.8 | 68 ₹8,878.08 Lowest | 72 ₹9,400.32 |
| 3.00 | Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M above the starting point complete all as specified and as directed. | 16.14 | Cum | 115 ₹1,856.1 | 105 ₹1,694.7 | 102 ₹1,646.28 | 110 ₹1,775.4 | 120 ₹1,936.8 | 120 ₹1,936.8 | 120 ₹1,936.8 | 100 ₹1,614 Lowest | 107 ₹1,726.98 |
| 4.00 | M&L for High density polyethylene DWC with UV stabilized pipes of size 90 x 76 mm for road crossing of cable and protection, laid in trenches under road / PCC or above ground surface all as specified and directed. | 200 | RM | 157 ₹31,400 | 147 ₹29,400 | 145 ₹29,000 | 154 ₹30,800 | 150 ₹30,000 | 160 ₹32,000 | 200 ₹40,000 | 140 ₹28,000 Lowest | 152 ₹30,400 |
| 5.00 | M&L for High density polyethylene DWC with UV stabilized pipes of size 110 x 95 mm for road crossing of cable and protection, laid in trenches under road / PCC or above ground surface all as specified and directed. | 600 | RM | 207 ₹1,24,200 | 199 ₹1,19,400 | 195 ₹1,17,000 | 204 ₹1,22,400 | 201 ₹1,20,600 | 210 ₹1,26,000 | 240 ₹1,44,000 | 190 ₹1,14,000 | 189 ₹1,13,400 Lowest |
| 6.00 | M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface complete all as specified and with PCC 1:3:6 type C1 by (using 20 mm graded stone aggregate) 100mm thick complete all as specified and directed. | 80 | RM | 317 ₹25,360 | 307 ₹24,560 | 305 ₹24,400 | 314 ₹25,120 | 550 ₹44,000 | 320 ₹25,600 | 380 ₹30,400 | 300 ₹24,000 Lowest | 315 ₹25,200 |
| 7.00 | Taking up/down existing defective cable of sizes 2/3/3.5/4 core 10 to 70 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station complete all as specified and as directed. | 200 | RM | 35 ₹7,000 | 27 ₹5,400 | 25 ₹5,000 | 33 ₹6,600 | 55 ₹11,000 | 37 ₹7,400 | 22 ₹4,400 | 20 ₹4,000 | 19 ₹3,800 Lowest |
| 8.00 | All as per above item No. 7 but for 95 to 300 sqmm complete all as specified and as directed. | 615 | RM | 40 ₹24,600 | 33 ₹20,295 | 30 ₹18,450 | 37 ₹22,755 | 65 ₹39,975 | 44 ₹27,060 | 30 ₹18,450 | 25 ₹15,375 | 23 ₹14,145 Lowest |
| 9.00 | Laying,jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. in trenches/on walls/floor/roof/ceiling etc of size 2/3/3.5/4 core 16 to 185 sqmm including necessary cable lugs, gland etc complete all as specified and as directed. | 300 | RM | 44 ₹13,200 | 33 ₹9,900 | 30 ₹9,000 | 40 ₹12,000 | 40 ₹12,000 | 48 ₹14,400 | 30 ₹9,000 | 26 ₹7,800 | 25 ₹7,500 Lowest |
| 10.00 | Supply & laying testing and commissioning in trenches or fixing on wall or passing through pipe or in cable ducts XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area including cable lugs, glands, insulation tape etc complete all as specified and as directed.
10 sqmm 4 core | 25 | RM | 254 ₹6,350 | 245 ₹6,125 | 242 ₹6,050 | 250 ₹6,250 | 247 ₹6,175 | 260 ₹6,500 | 240 ₹6,000 | 235 ₹5,875 Lowest | 240 ₹6,000 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
12 Aug 2026, 6:00 pmClosed
Ankit Kumar, IDSE, EE, GE Chilka
Shri Samrom Lugun, AGE Contracts and Shri Krupasindhu Das, AIFA Chilka
REPAIR REPLACEMENT AND MAINTENANCE TO LT DISTRIBUTION SYSTEM AND ALLIED WORKS AT ZONE II OF INS CHILKA UNDER GE CHILKA
2026_MES_780222_1
GE/CHL/8219 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Chilka
MES Enlisted contractor of Class E Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE Chilka
₹28,000
Yes
25 Sept 2026
23 Jul 2026
19 Aug 2026
23 Jul 2026
12 Aug 2026
5 Aug 2026
24 Jul 2026 - 29 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 M in wide and not exc. 1.5 M in depth for taking out or laying of under ground cable in soft / loose soil complete all as specified and as directed. | 146.7 | Cum | - | - |
| - | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and as directed. | 130.56 | Cum | - | - |
| - | Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M above the starting point complete all as specified and as directed. | 16.14 | Cum | - | - |
| 4 | M&L for High density polyethylene DWC with UV stabilized pipes of size 90 x 76 mm for road crossing of cable and protection, laid in trenches under road / PCC or above ground surface all as specified and directed. | 200 | RM | - | - |
| 5 | M&L for High density polyethylene DWC with UV stabilized pipes of size 110 x 95 mm for road crossing of cable and protection, laid in trenches under road / PCC or above ground surface all as specified and directed. | 600 | RM | - | - |
| 6 | M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface complete all as specified and with PCC 1:3:6 type C1 by (using 20 mm graded stone aggregate) 100mm thick complete all as specified and directed. | 80 | RM | - | - |
| 7 | Taking up/down existing defective cable of sizes 2/3/3.5/4 core 10 to 70 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station complete all as specified and as directed. | 200 | RM | - | - |
| 8 | All as per above item No. 7 but for 95 to 300 sqmm complete all as specified and as directed. | 615 | RM | - | - |
| 9 | Laying,jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. in trenches/on walls/floor/roof/ceiling etc of size 2/3/3.5/4 core 16 to 185 sqmm including necessary cable lugs, gland etc complete all as specified and as directed. | 300 | RM | - | - |
| 10 | Supply & laying testing and commissioning in trenches or fixing on wall or passing through pipe or in cable ducts XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area including cable lugs, glands, insulation tape etc complete all as specified and as directed.
10 sqmm 4 core | 25 | RM | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
8219Tenderpage.pdf
Tender Documents • 0.55 MB
BOQ_873958.xls
BOQ • 3.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .