| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.9 L+₹28,394 (1.26%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹23.9 L+₹1.4 L (6.01%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹26.1 L+₹3.5 L (15.4%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹26.7 L+₹4.1 L (18.1%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
17 Jun 2023, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR MAINT AND REPLACEMENT OF STREET SECURITY LIGHTS, WATCH TOWERS LIGHTS, HIGH MAST LIGHTS, FENCING LIGHTS IN DOMESTIC, TECH AREA AND RAKSHA NAGAR AT 11 BRD AF STN OJHAR
2023_MES_599619_1
8991/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
Yes
28 Jul 2023
30 May 2023
20 Jun 2023
31 May 2023
17 Jun 2023
12 Jun 2023
Amount
Taking down old unserviceable street light fittings /high way light /flood light/Watch tower light ) of any type and capacity up to 15 mtr heights and deposited to MES store yard for further disposal.
Supply, Installation, Testing and commissioning LED street light fittings 100 watt with minimum110 lumen/ watt system lumen output.The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection Make Crompton CAT No TRP-409-100-57-SL-GL-NSG or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply, Installation, Testing and commissioning LED street light fittings 70 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No TRP-409-70-57-SL-GL-NSG or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge..
Supply, Installation, Testing and commissioning LED street light fittings 60 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No TRP-409-60-57-SL-GL-NSG or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge..
Supply, Installation, Testing and commissioning LED street light fittings 45 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LSTS-25-CDL/NL-M or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply, Installation, Testing and commissioning LED Flood light fittings 150 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-120- CDL/60-M or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply, Installation, Testing and commissioning LED Flood light fittings 120 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-120- CDL/60-M or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply, Installation, Testing and commissioning LED Flood light fittings 100 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-80-WW CDL/60-M or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply, Installation, Testing and commissioning LED Flood light fittings 80 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-80-WW CDL/60-M or equivalent in Havells/ Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply & Fix in repair PVC perplex cover glove type with Base plate /holder not less than 8 inch dia suitable for Post top lantern including one nos 7/9 watt LED lamp complete all as specified and directed by Engineer- in-charge.Make - Bajaj / Surya/*havells.
Repairs to High mast light 15/30 Mtr high, by taking down the luminaires mounting frame mechanically and replacing the unserviceable items (paid separately) including lifting the superstructure after repairs and testing complete all as specified and as directed by Engr-in- Charge..
Taking down old /unserviceable solar street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of follwing part for proper functiong complete all as specified and as directed by engr-in -charge.
Supply only Solar light fitting AIO Charge contrller for 18 W, Make-Bajaj SUNSOKO or equavalent of Crompton/Havells
Supply only Solar light fitting AIO PIR sensor for 18 W, Make-Bajaj SUNSOKO or equavalent of Crompton/Havells
Supply only Solar light fitting AIO Li-Ion Battery for 18 W, Make-Bajaj SUNSOKO or equavalent of Crompton/Havells
Taking down old /unserviceable street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of LED driver of 120 watt complete all as specified and as directed by engr-in -charge.
Takingdown old /unserviceable street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of LED driver of 70 watt complete all as specified and as directed by engr-in -charge.
Taking down old /unserviceable street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of LED driver of 45/30 watt complete all as specified and as directed by engr-in -charge.
Supply & Fix in repair LED Post top lantern weather proof indirect lighting solution Make Cormpton Cat Pt No LPTC-40-CDL or equivalent in Havells/Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply & Fix in repair Post top lantern decorative HERITAGE LED suitable 1X20 Watt retro LED with opel deffuser including LED 20 Watt of Make Crompton Cat Part No LPTH-20-CDL or equivalent in Havells/Bajaj.complete all as specified and directed by Engineer- in-charge.
S&F in repair flat twin core 10 sqmm nominal cross sectional area multistand aluminium conductor cable over all PVC shathed 1100 volt grade Heavy duty cable complete all as specified
S&F in repair flat twin core 6 sqmm nominal cross sectional area multistand aluminium conductor cable over all PVC shathed 1100 volt grade Heavy duty cable complete all as specified
Supply and fix in repair street light bracket 32/40 mm bore GI pipe/tubing light grade not less than 1.2 Mtr long band to shape with 2 nos MS clamps flat iron 50 x 5 mm for nuts, bolts and washers suitable for Steel/PCC Pole etc and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make- Prakesh surya/Swastik/Jindal
Material and labour for cable joint termination box PVC body housing suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA C series. Make : Standard/ HPL/L & T.
Supply and fix in repair MCB SPN 32 Amps 240 volts 10 KA. Make : Standard/ HPL/ L & T.
Supply and fix in repair MCB SPN 63 Amps 240 volts 10 KA. Make : Standard/ HPL/ L & T.
Supply and fix in repair Isolator TPN 63 Amps 415 volts 10 KA. Make : Standard/ HPL/ L & T.
Supply and fix in repair Sheet metal enclosure for DB’s with out bus bar for 2 way 240 volts. Make : Standard/ HPL/L & T Legrand.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 100 amps rated bus bar , 2 way ,240 volts double door. Make : Standard /HPL/ L & T.
Supply and fix in repairs power contactor, ML-3type Three pole, 440 volt , Auxilary coil voltage 230 Volt, Make- L&T/Legrand/Semiens
Supply and fix in repairs Time digital switch with built in PCB for street light , Make L&T, type DIGICON or equivalent of GEC/ GIC/ Havells.
S&F PVC insulated and weather proof three core copper multi stranded conductor cable 1.5 Sqmm size as required length for replacing unserviceable cable for street light where ever found unserviceable and required from junction box to street light connector of Street Light fittings all as specified & as directed by Engr-in-Charge.
Supply and fixing Straight through joints( heat shirnk) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 4 core 16 Sqmm.
Dismantling of LT PCC/Steel pole and removing the dismantling mtrl to more than 100 mtr distance as reqd at site complete all as specified and directed by Engr -in-charge.
Shifting of LT Pole any type from one place to another places entire location of 11 BRD including all connection/disconnection of electric supply including all earth works as reqd at site complete all as specified and directed by Engr -in-charge.
Tree cutting around the street light fittings any type complete 3 mtr radious of street light fitting complete and removint the mtrl to not exceeding 100 mtr from the site. all as specified and as directed by engineer in charge.
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable multistanded with aluminium conductor 1100V grade 4 core cross sectional area 10 sqmm ISI marked all as specified and directed.
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable with aluminium conductor 1100V grade 2 core cross sectional area 10 sqmm ISI marked all as specified and directed.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 38mm
Supply and fix 40mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
S&F Octagonal GI Pole 7 mtr long with dome, top 70 mm and bottom 130 mm fixing on base plae 200X200X12 mm with suitable size of foundation nut & bolt. including all earth work and PCC fondation as recommeded by OEM complete all as as directed by Engr-in-charge.Make Bajaj, CG,Surya.
S&F Octagonal GI Pole bracket single arm 1.50 mtr long, fixing withsuitable nut bolt and washer as described in OEM manual complete all as as directed by Engr-in-charge.Make Bajaj, CG,Surya.
M&L for checking the serviceability of fencing street light /Hanger security light/ Watch Tower light at Tecnical area and Domestic area. The contractor Rep shall be present at Domestic area sub stn at 6.00 PM every day for ckecking of street light serviceability and trace out the minor fault/defects if any and repair the same at site for proper functioning of the street lights. Note:- (i) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a penality of an amount of Rs 250/- complains/ day will be imposed and will be recovered from RAR/F bill.(ii) Contractor rep will submit daily report of serviceability of above mentioned lights to JE E/M/Engr -in-charge(ii) T&P required for checking to be arrange by the contractor(iii) The rate for above Note works will be deemed to be included in quoted rates by the contractor
M&L for Preparation of old painted surfaces of steel tublar poles LT 9.0 Mtr long & painting two coats of aluminium paint from top to bottom and painting with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, including existing cross arm/angle iron/clamps/brackets etc & marking of pole numbers in white on black background all as directed.
Taking out the old burnt LT cable from panel /Pole junction box, trace out the fault and rectified the same by cutting the burnt portion of cable and making suitable joint, connection with suitable size lugs/thimble, insulation tape etc as requited at site complete all as specified and as directed by engr-in charge Note : Excavation earth work will be included in the quoted rate all as directed.
Taking out the old/unsv LT cable from the trench and find out the defects and repair the same before re-laying/re-routing complete all as specified and as directed by engr-in charge Note : Excavation earth work will be included in the quoted rate all as directed.
sapana enterprises
shakti engineering and electrical works
M/S SVOJAS ELECTROMECH ENTERPRISES
MAHIMA CONSTRUCTION
K R Electricals
Datar Electrical and Engg Services
SHRI SULAI ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .