| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.8 L+₹5,190 (0.53%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.0 L+₹31,230 (3.21%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical A 249 1ST FLOOR TODAY BLOSSOM 1 SEC 47 GURUGRAM | GURUGRAM | GURUGRAM | HARYANA | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹10.1 L
EMD Value
₹20,300
Closing Date
14 Mar 2022, 5:00 pmClosed
RAJA NAGENDER SINGH
NIRMAN SADAN , 4TH FLOOR, CIVIL LINES , PWD B and R (Elect.)GURUGRAM
Construction of Sub Tehsil building at Hassanpur in District Palwal (CM announcement code no. 15180 dated 09/10/2016) (Providing E.I. and street light)
2022_HRY_209670_1
PWD (Elect.) Feb. 2022
Open Tender
Electrical Works
Works
360 days
XEN(E) Gurugram
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹20,300
7 May 2024
28 Feb 2022
15 Mar 2022
28 Feb 2022
14 Mar 2022
28 Feb 2022
Amount
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLs copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/ recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia.
MS pipe of 25 mm dia.
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
PVC pipe of 32 mm dia.
PVC pipe of 40 mm dia.
FITTING AND ACCESSORIES Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type
Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt
Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless stell wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required
Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc.Supply and erection of Modular case circuit breaker single pole / 4 pole on existing wall/ pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp
4 pole MCCB 125 to 160 amp
Supply and erection of sheet steel enclosures 1pole/ 2 pole/4 pole including providing SP/DP/TP/FP MCB on wall/on existing pedestal complete with necessary connections etc, :- SP enclosure suitable for single pole MCB
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:-6 amp. to 32 amp Single Pole
6 amp. to 32 amp MCB's Triple Pole
40 amp to 63 amp. MCB's Triple Pole
Supply and erection of blanking sheet in existing distribution board.
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
Extra for using salt and char coal/coke for pipe earth electrode as required.
Earthing with tinned copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
STREET LIGHT Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 1 O A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 1 O of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge7 Mtr Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Supply and erection of 1 no. 12 way moduler box made of G.I. sheet with inner & outer plate including cost and fixing of 3 nos. sockets and 3 nos. switches of 5 amp and 1 no. multi socket and switch of 15 amp, M.S. box duly recessed in wall, cost of necessary cement and sand mixture making necessary connection complete in all respect upto the entire satisfaction of Engineer-in-charge of work. (for computer point )
Supply and erection of Double door sheet, steel superline/ Powerline Vertical distribution boards suitable for TP/ FP veritcal MCCBs. MCCB upto 250 amp as incomer (but without cost of MCCBs) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (loadline) 8 way load line
12 way load line
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe complete in all respect upto the entire satisfaction of Engineer in charge of the work 1.5 sq.mm
Supply and erection of PVC sheathed copper conductor cable 2 core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe complete in all respect upto the entire satisfaction of Engineer in charge of the work 1.5 sq.mm
Supply and erection of cable on surface/ cable tray complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work 16 Sq. mm 2 Core armoured Cable .
25 Sq. mm 3.5 Core armoured Cable .
16 Sq. mm 4 Core armoured Cable .
Supply and erection of under ground cable in pipe/ existing open / closed trench complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work 16 Sq. mm 4 Core armoured Cable .
Supply and erection of 90/100 watts LED street light fittng with lense IP 66, HP dia cast aluminium hoising including erection of same on Pole with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge.
Supply and erection of Single arm. G.I. Bracket made of 50 mm dia G.I pipe B class ISI 1.5 mtr. long with 25 mm dia G.I. bottom pipe with 75 mm dia 60 cm. long G.I. collar pipe, top covered with ornamental cap duly welded, painted 2 coats of aluminium paint on bracket and golden paint on ornamental cap including erection of same with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work.
Supply and erection of LED flood light fitting including erection of same on pole/ parapet with necessary nuts & bolts and making necessary connection of same complete in all respect upto the entire satisfaction of the Engineer-In - charge of work.120 watt LED flood light
Supply and erection of post top lantern suitable for 40/45 watt LED lamp with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge.
KKM Engineering Solutions Pvt. Ltd.
MANYA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .