Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-Finance Accepted being L1 | |
| 2 | L2₹44.3 L+₹5.2 L (13.4%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹49.1 L+₹10.0 L (25.7%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.2 L+₹10.2 L (26.0%)Rejected-Finance 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L4 | Rejected-Finance Rejected being L14 | |
| 5 | L5₹49.6 L+₹10.5 L (26.9%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
20 Mar 2023, 6:00 pmClosed
GE I RD East Bangalore
GE I RD East Bangalore 93
REPAIR REPLACEMENT OF UNSERVICEABLE SUBMAIN WIRING POINT WIRING SWITCHES SOCKETS AND EARTHINGS FOR BUILDING UNSERVICEABLE DISTRIBUTION BOARDS LT FEEDER BOX MSBS BUILDING SECURITY LIGHT INDUSTRIAL SOCKETS MCCB ISOLATORS GARDEN LIGHTS INCLUDING ALLIED
2023_MES_582944_1
8344
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I RD East Bangalore
D b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹96,000
Yes
27 Mar 2023
25 Feb 2023
22 Mar 2023
25 Feb 2023
20 Mar 2023
11 Mar 2023
27 Feb 2023 - 6 Mar 2023
Amount
Point wiring complete with Multi stranded copper conductor size 1.5 sqmm (for phase and neutral ) PVC insulated, unsheathed,FRLSH cable , 1100 volts grade conforming to IS 694 multistranded , drawn in and including rigid PVC surface type conduit / casing capping on walls/ floors/ ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly, cutting chasis to the wall s/ floors/ ceiling and repairing with existing surface after work ,complete all as specified and directed. Note:- Including taking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
One light/ fan/exhaust fan point controlled by one way switch
One light point controlled by 02 two way switches
One three pin socket outlet 6 amps socket on the same board with other switches
One 3 pin socket point 5 Amps on the independent board.
One bell point controlled by one bell push
M&L Point wiring complete with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed,FRLS cable , 1100 volts grade conforming to IS 694 multistranded , drawn in rigid PVC type conduit concealed in walls / floors/ ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly,cutting chasis to the wall s/ floors/ ceiling and repairing with existing surface after work ,complete including taking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc all as specified and as directed. Note:- IncludingTaking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
One light/ fan/exhaust fan point controlled by one way switch
All as per item No 2 here-in-before, but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLS cable with copper conductor size 2.5 sqmmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 amps soket outlet independently all as specified and as directed by engr-in-charge. Note:- IncludingTaking down carefully U/S aluminium/ copper power point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
Supply & fix switch modular type single pole 1 way 6 Amp 230 volt complete as directed.
Supply & fix switch modular type single pole 2 way 6 Amp 230 volt complete as directed.
Supply & fix Socket Modular type 6A 2-3pin combined 2 module 230Volts grade all as directed.
Supply & fix switch modular type 1 way 16A, 1 module all as specified and directed.
Supply & fix Socket Modular type 6A/16A 2-3pin combined 2 module 230Volts grade all as directed.
Supply & fix Modular switch bell push 6 Amps one module all as specified and directed by Engr-in-Charge
Supply & fix modular type fan regulator 120 W two module complete all as specified and directed by Engr-in-Charge
Supply and fix bell AC 230V single phase all as specififed and directed by Engr-in-Charge
Supply & fix ceiling rose surface bakelite two to three terminal complete all as directed.
Supply and fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
Supplying and fixing LED batten with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & intregrated electronic driver1 x 20 watts fixing on wall/ celing with rod complete all as specified as directed.
Supply and fixing 10 Watt LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing LED luminaires square type 2x2 36 W with Environmental friendly new generation aestheticall designed ,ultra modern recess mounting iuminaire with high brightness SMD LEDs as light sourse sutible for armstong/gypsum or similar ceiling mounting system including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed by Engr-in-charge.
Supply and fixing very High efficiency round High Bay LED fittings 120 watt, 220 V AC in PDC housing complete with driver, holders & LED lamp suitable for idustrial purpose including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Dismantling the ceiling fan complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and complete spray painting as directed by Engr-in- charge testing all as directed. Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted.
Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper wining from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling , greasing to bearing , replacing bushes, replacment of capacitor and complete testing all as directed. Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured and paid separately under respective item. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
All as per item No 20 herein before but for 1400mm sweep ceiling fan
All as per item No 20 herein before but for upto 300mm sweep exhaust fan
All as per item No 20 herein before but for 300 mm to 450mm sweep exhaust fan
All as per item No 20 herein before but for 400 mm to 450mm Wall mounted fan
All as per item No 20 herein before but for 400 mm to 450mm Padestal fan
Supply and replace worn out fan bearings suitable for ceiling fan /exhaust fan of the existing size of superior quality complete all as specified and directed
Supply and replace capacitor 2.5mfd suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed
Supply and replace capacitor 4.0mfd suitable for exhaust fan complete all as specified and directed
M&L painting of exhaust fan along with down rod and blades using spray gun with existing colour at the site including dismantling the fan from the hook complete all as specified and as directed
Sub main wiring complete with 2 runs of 4 Sqmm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor confirming to IS-649, 1100 volts grade with colour code and drawn through and including 25mm dia PVC non metallic rigid conduits and conduit accessories run on surface of wall / floors / ceiling etc and connecting terminal ends including 1x 2.5 Sqmm PVC insulated unsheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth complete all as directed and specified. Note: Four runs of 6.0 Sqmm copper cable, two run of earth wire of 6.0 Sqmm copper cable and 25mm dia PVC conduit shall be measured and paid as one RM.
Sub main wiring complete with 2 runs of 6 Sqmm PVC Insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including concealed 20mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 1x4 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: Two runs of 6.0 Sqmm copper cable, one run of earth wire of 4.0 Sqmm copper cable and 20mm dia PVC conduit shall be measured and paid as one RM.
Sub main wiring complete with 4 runs of 10 Sqmm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 2x6 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: Four runs of 10 Sqmm copper cable, two runs 6 Sqmm earth wire and 25mm dia PVC conduit shall be measured and paid as one RM.
Sub main wiring complete with 2 runs of 2.5 Sqmm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 1x1.5 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: Four runs of 2.5Sqmm copper cable, two runs 1.5 Sqmm earth wire and 25mm dia PVC conduit shall be measured and paid as one RM.
Taking down old sub main wiring of any type and size complete all as specified and directed
Taking down unserviceable DBs including MCCBs/MCBs complete issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
Supply and fix in replacement of MCB DB SPN 4 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed
All as per item No 36 here in before but of 8 Way 230 Volt all as specified and directed.
All as per item No 36 here in before but of 12 Way 230 Volt all as specified and directed.
Supply and fix in replacement of MCB DB TPN 4 way DB double door type single phase 415 Volts complete including dismantling the old one all as specified and directed
All as per item No 39 above but of 6 Way DB double door all as specified and directed.
M & L for Single pole and neutral enclosure with a two pin and earth plug and socket plug and soxket completewith one MCB single pole of 20 Amps
Supply and fix in replacement of MCB SPN 32Amps 230 Volts C curve single phase all as specified complete including dismantling the old one
All as per item No 42 above, but MCB SPN 40 to 63 Amp 240 Volt complete all as specified and directed
Supply and fix in replacement of MCB SP 5-32Amps 230 Volts single phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB TPN/FP 40 to 100 Amps 415 Volts three phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB TPN 16-32Amps 415 Volts three phase all as specified complete including dismantling the old one
Supply and fix in replacement of MCB TP 25 TO 63 Amp 415 Volts three phase all as specified complete including dismantling the old one
Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed. NOTE: Earth resistance not exceeding 1.0 ohm.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed
Supply and fixing LED street light fitting/building security light 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specifed and directed.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
All as per item No- 52 above but of cap 40 W complete all as specified and directed
Supplying of LED tube rod of 20W suitable for fixing of fluoresecent tube light fittings of 36/40W all as specified and directed.
Supplying of LED 4 pin type rod of 18W suitable for fixing of fluoresecent light fittings of 36W all as specified and directed.
Earthing complete with galvanised iron plate electrode 600 x 600 x 6.00mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Galvanised iron strip 32x6 mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement cioncreat (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately. 3. Earth resistance not exceeding 1.0 ohm.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4 mm galvanised iron or steel wire
Supply, installation, testing and commissioning of CPRI Approved Indoor LT Pannel consisting of double door separate compartment with lockimg arrangement for each feeder floor mounting fabricated out of 2.0 mm thick MS shee on angleiron frame of 25 x25x5 mm and legs made of angle iron 40x40x6mm , painted with powder coated and pre coted primer including necessory PCC 1:3:6 Type C2 foundation and earth work and comprising the following :- (a) Busbar chamber of 3 Phase and neutral 4 strip 415 volts with 400 Amp Copper strip- 1 SET (b) Moulded Case Circuite Breaker 4 pole 25 KA breaking capacity 125Amp (Incomimg) - 01 Nos (c) Moulded Case Circuite Breaker 3 pole 16KA breaking capacity 63 Amp (Out Going)-04 Nos (d) Motor Star delta starter 20 HP-03 nos (e) Three phase volt meter(0-500 Volt) -1 No (f) Three phase Ameter (0-300 Volt) -1 No (g) LED Indicater lamp Red, Yellow,Blue- 01 set (h) Complete internal wiring with suitable cpper conductor wires-1 Lot (j) Provision of etra space for One more outgoing feeders Suitable for 63 Amps MCCB Note:- All Termination of cable should be provided with copper lugs/ thimbles and suitable size of gland & rate for the same is deemed to be included In this item
Opening of electric connection from existing panel for the replacement purpose and dismanltling the unsv panel carefully and removing the same from site as per direction of Engr-in- Charge all as specifed and directed.
Solar Electricals and Electronics
GURU ENTERPRISES
Sreyas Enterprises
GS TRADERS
YUVARAJ ELECTRIC AND CO
Glacier Cooling Solutions Private Limited
G K CONSTRUCTIONS
B5BUILDING SOLUTIONS
Meghana and Gowda Enterprises
Lucky Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .