| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹46.7 L+₹1.4 L (3.00%)Rejected-Finance NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹52.4 L+₹7.1 L (15.6%)Rejected-Finance NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
26 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Central Bangalore
Military Engineer Services Garrison Engineer Central Agram Post Bangalore PIN- 560007
REPAIRS, MAINT B R COMPLAINT NATURE WORKS AT MD ACCN OLD DOMLUR AND NEW DOMLUR UNDER AGE B R-1 OF GE (CENTRAL) BANGALORE
2023_MES_597368_1
8303E
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Central Bangalore
Please Refer Tender Documents
6 documents required · 6 mandatory
₹500
Garrison Engineer Central Bangalore
₹44,000
Yes
5 Aug 2023
22 May 2023
28 Jun 2023
22 May 2023
26 Jun 2023
14 Jun 2023
22 May 2023 - 1 Jun 2023
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etcand removal of entire debris as ordered outside MD land complete all as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thick above or below ground level and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of debris to a distance not exceeding 50 mts and depositing where directed.
Dismantling of AC Corrugated or semi corrugated sheet etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to a outside MOD land and depositing where directed complete all as directed.
Dismantling boarding, any description, fixed in any position with nails and stacking at site where directed for Credit.
Dismantling of tile wooden battens as in tiles of any size including tiling fillets exe 15 cm spacing complete and stacking where directed.
Dismantling of timber scantlings 40 Sq cm and over in section in any position unframed work and stacking at site where directed complete.
Dismantling single layer mangalore pattern roof tiles including ridges laid and set in cement mortar complete all as directed.
Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MD land complete all as directed.
Taking down shutter of any description area exceeding 1 Sqm but not exceeding 2 Sqm each and refixing in the same opening after cutting , easing and adjustmentas with old ll types of builders hardware complete all as directed.
All as per item No 11 here-in-above but not exceeding 1 Sqm -do-
M & L for PCC 1 :4 : 8 type D2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO , Acco Proof , Impermo , Aqua flex as approved.
M&L for Type B0 1:2:4 (12.50 mm graded aggregate) providing cement concrete as in Padding over roof / chajja finished even and smooth without using extra cement. complete all as specified and as directed.
M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO, Acco Proof, Impermo, Aqua flex as approved.
S&F in repairs Pre-laminated particle board , Exterior grade 18/19 mm thick (ISI Marked) , pre-laminated both side with decorative choice lamination including 3 mm thick teak wooden beading alround as ordered complete all as specified.
S & F in repair150 mm long aluminium, anodised , barrel tower bolt (ISI marked) of extruded section and fixed.
S&F in repair 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F in repair 100 mm size aluminium alloy handles (ISI Marked) cast type anodised and matt finish not less than Gd AC 10 of IS: 1868 :1986 fixed.
S&F in repair 125 mm size aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
S&F in repair 300 mm long aluminium alloy, anodised sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S & F in repairs aluminium anodised, hasp and staple, safty type, with hinge pin, including bolt to hinge plate and fixed with screws complete all as directed.
S&F in repair Mild steel powder coated body door stopper with hard drawn steel spring, 140mm size fixed to door all as directed.
S&F in repair magnetic catcher with 8 mm dia steel ball & brass body & striking plate including letting in fixed complete all as directed.
S & F 30 mm width of flap Continous (Piano) hinges, mild steel, bright finish or electrogalvanised.
S & F in repair 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified
S&F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples including supply & fix second class hard wooden fillet, wrought, cross sectional area exceeding 3 Sqcm but n.exc 6 Sqcm fixed with nails complete all as directed.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Grade E-165 (Fe 290) and fixed in position.
M & L for running welding in repairs thickness of metal to be welded n exc 6mm
M&L for welding in repairs not exc 2.5cm in length, thickness of metal to be welded not exc 6mm complete all as specified
M&L Second class hard wood well seasoned wooden scantling clean sawn framed & fixed to walls with screws complete all as directed.
M&L for second class hardwood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed, complete all as specified & directed
All same as per item No.33 here -in - above but except wooden boarding - (Note : wooden boarding obtained from item No 5 here -in - above)
M&L for Second class hard wooden battens spaced at 30 cm centre to centre clean sawn cross sectional area exceeding 5 sqcm but not exc 15 sqcm complete all as directed.
Material and labour for removal of existing WPT course or any other kind of treatment surface over roof slab and cleaning of surface with wire brushes and water removing of unsolvent materials and depositing of the same outside MoD land and provide 10 mm thick screed bed/ bedding layer in CM 1:3 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply oil bound bituminous primer @ 0.20 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure as directed, apply a coat of blown grade hot bitumen 90/15 grade over the membrance @1.2 Kg/Sqm and finally finished the top surface with solar reflective bituminious aluminium @ 0.10 Kg/Sqm complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive of taking down & removal of debris , 15 mm thick 1:3 screed & complete APP treatment. (ii) WPC will be paid seperately (iii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M & L for roof surface must be pressure-washed with water with, is to be used to and/ or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution. 2 tiles joint repair all visible and joint more than 0.50mm and not giving hollow sound, on the tiles roof or at the junctions of flat roof & vertical parapet wall, pipe joints, should be cut and widen v shape with mechanical cutter in the size (6mm W x 6mm D) and fill with Dr. Fixit PMM methodology.Glass fiber apply Dr Fixit URP or Primeseal A on the well prepared groove, allow to cure tack free. Followed by filling all the joints covering the entire area uniformly with suitable chemical. Allow chemical to cure a minimum 24 hours. Apply minimum 50mm-100mm width 45 GMS glass Fibre mesh/ non-woven geo testile fleece with the coat of Dr Fixit Roofseal classic along the length of crack when the 1st coat is still in wet condition. Apply the second coat with an interval if 4-6 hours. Waterproofing: Apply a coat of Dr Fixit Roofseal classic (diluted with water in the ratio 2:1) as Self Priming 14.0-18.0 Sq. mt/litre.Allow coating to dry for 3-4 hours. Applt two coats of Dr Fixit Roofseal classic/litre/coat, without, the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total of DFT of microns. Allow the system to air cure for 5 days minimum. Check to see no void surface is left untreated/uncoated. The material having following technical specification as per ASTM D 6083 M- type II, Attains a Tensile strength of 2.5 N/mm2 confirming to ASTM D 2370: Elongation at break > 300% confirming ASTM D 2370, Adhesion to Concrete 2.0N/mm2 Confirming ASTM D 4541 and crack bridging ability up to 2mm, air cure the coating for 7 days before water pound test for 48 Hrs. The system comes with 7 year waterproofing warranty from service provider. For vertical surface : Apply 2 coat of Dr Fixit Roofseal classic with forced coverage of /litre/coat. Entire terrace should be coated with roofseal classic alongwith parapet walls needs to be enveloped with roofseal classic/Raincoat system. The total 3 coats treatment
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified & directed
Supply and fix Pre- painted galvalume aluminum zinc coating GI plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction all as specified and as directed.
Supply and fixing 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with self tapping screws and washer in roof, wall etc complete all as specified & as directed
M&L for Mangalore pattern roof tiles interlocking at side joints laid dry including cutting holes through tiling for pipes and making good the disturbed surface to its original specification complete all as directed.
M&L for Ridges or hip tiles to suit Manglore pattern roofing tiles bedded and jointed in cement mortar 1 : 6 complete all as directed.
Cutting/chipping the spalling concrete surfaces of columns, beams, facias, slabs, Chajjas & cartilevers etc., and trimming cleaning the surfaces of any thickness as ordered and applying epoxy treatment for bonding old demolished concrete surfaces incl application of one coat of notozinc primer to the exposed reinforcement and over plastering in CM 1:4 average 20mm thick finishied even and smooth without using extra cement to level the surface etc incl necessary scafolding as required at site and where required complete all as specified and directed
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing the same with neat cement slurry with 3.0 Kg of cement per Sqm complete all as directed.
M & L for 75 mm thick plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base of floor and finished the surface complete all as directed.
M&L for 40mm thick plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floor and finished the even and smooth without using extra cement complete all as directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floor and finished the surface suitable to receive floor tiles complete all as directed.
M & L non-skid coloured joint free ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified.
All same as per item No 48 here-in-above as in skirting but tiles laid over and including 10 mm thick screed bed in cement mortar 1:4 -do- (Note for item Nos 48 & 49 : i) Quoted rate is deemed to be inclusive of cement screed. ii) Shade / pattern / Colour of tiles shall be got appproved before procurement).
M & L for Rendering 15 mm thick in cement mortar 1:4 on internal concrete surface mixed with WPC @ the weight of minimum 3% by weight of cement mixed or as per manufacturer instruction , and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC measured and paid separately.
M & L rendering 15 mm thick CM 1:6 on stone masonry surfaces other than fair face of brick work or one sided lathing finished followed by 10mm thick settting coat in CM 1: 6 including finishing surface even and smooth without using extra cement in walls complete all as specified and directed by Enigineer in Charge
M&L for rendering 10 mm thick in CM 1:6 on brick work/stone work or concrete surface finished the surface even and smooth without using extra cement complete all as specified.
All as per item No 52 here-in-above but 5 mm thick in CM 1:3 on ceiling,chajja,roof projection etc.
M& L for Keyed pointing to squared rubble, coursed or un-coursed stone masonry bangalore type in cement martar 1 : 4 complete all as directed.
Three coats of white wash on newly plastered surface of ceilings after necessary preparation of surface complete all as directed.
Preparation of newly plastered wall surface and & applying two coats of cement base paint over a coat of alkaline resistant primer complete all as directecd.
M&L preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 3 mm thick white cement based wall care putty as ordered complete all as specified.
Hacking out old broken glass (any thickness) and size from wooden frame glazed with putty or fixed with wooden beads and removal of debris to a distance n.exc 50 mtr and depositing where directed.
S&F sheet glass 4mm thick glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as directed.
S&F sheet glass 4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as directed.
M & L Two coats of 1st quality synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm in width or girth including necessary preparation of new wooden surface complete all as directed.
One coat of first quality synthetic enamel paint of any description over 10 cm in width or girth on old painted wooden surface after necessary preparation of surface complete all as directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth not otherwise described and treated with two coats of creosote oil complete all as specified
Taking down old 20 mm bore GI tubing and connection from Bldg after necessary disconnection & S&F new CPVC pipe SDR II having outer dia 20 mm pipe with plain CPVC SDR II fitting such as bends, elbows, unions and end pieces to receive the fittings and fixed with solvent cement in walls/ceilings (concealed/surface) or laying in floors in same or different locationas ordered making necessary connection & testing complete to thhe satisfaction of Engineer-in-charge complete all as specified
Taking down old 25 mm bore GI tubing and connection from Bldg after necessary disconnection & S&F new CPVC pipe SDR II having outer dia 25 mm pipe with plain CPVC SDR II fitting such as bends, elbows, unions and end pieces to receive the fittings and fixed with solvent cement in walls/ceilings (concealed/surface) or laying in floors in same or different locationas ordered making necessary connection & testing complete to thhe satisfaction of Engineer-in-charge complete all as specified
Taking down old 15 mm bore GI tubing and connection from Bldg after necessary disconnection & S&F new CPVC pipe SDR II having outer dia 16 mm pipe with plain CPVC SDR II fitting such as bends, elbows, unions and end pieces to receive the fittings and fixed with solvent cement in walls/ceilings (concealed/surface) or laying in floors in same or different locationas ordered making necessary connection & testing complete to thhe satisfaction of Engineer-in-charge complete all as specified
Taking doown wornout/ unservicable any type & dia of pipe from any description & Supply & Fix new 20 mm bore steel water tubing medium grade (ISI marked) with fittings all new (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
Taking down bib tap, pillar cock, stop/angle cock, & shower rose etc for carrying out repair/ refixing the same in old position after cleaning, replacing washer, spindle and adjusting screws etc complete all as directed.
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified & as directed.
S & F in repairs brass, chromium plated, 15mm bore wall mixer for mixing hot and cold water, screwed down with provision of over head shower and cock for iron pipe and fixed complete all as specified and directed. Make: PRAYAG Cat No 8475 or equvelent of Make Hindware/Parryware/CERA
S & F in repair PVC flush handle including connecting rod & shiphon washer suitable for 10 litre capacity PVC flushing cistern complete all as directed.
S & F in repair PVC syphon set complete suitable for 10 litre capacity PVC flushing cistern complete all as directed.
Replacing old unserviceable steel brackets for wash hand basin (Flat or angle back) including cutting for pinning in end of 12mm dia bolt erecting stand, inlet and outlet screwed for pipe or connection including necessary packing all as directed.
S&F in repairs 15 mm medium grade galvanized, with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F in repairs 15mm bore Stop valve, fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union
S&F 20mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe
S&F in repair bathroom mirror cabinet (PTMT) of size 430 x 330 mm fixed on wall with chromium plated brass screws all as directed. Make :- Prayag (Cat Part No. 551) or equivalent of Commander (Jasmine) / Polytuf / Jindal / Parryware
S & F in repairs PVC connection pipe with PTMT nuts, 600mm long complete all as specified
S&F 32/40mm bore Low density polyyethylene (LDPE) pipes of pressure rating 6 kgf/Sqcm with connecting bracket fixed to waste coupling for basin/sinks complete all as specified and directed.
S&F in repairs 32 mm size brass chromium plated Waste coupling for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
All same as per item No 81 here-in-above but 40mm size -do-
S & F in repair 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints laid in trenches complete all as specified and directed.
S & F in repair 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints laid in trenches complete all as specified and directed.
S & F in repair 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes or for rain water pipe in any length without ears, with rubber ring joints fixed to wall using MS holder bat complete all as specified and directed.
S & F in repair 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes or for rain water pipe in any length without ears, with rubber ring joints fixed to wall using MS holder bat complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S&F PVC (SWR) branch piece single,(single Y) 110 mm dia equal or unequal with oval access door complete all as specified and directed.
S&F PVC (SWR) branch piece single,(single Y) 75 mm dia equal or unequal with oval access door complete all as specified and directed.
S&F PVC (SWR) branch piece (double Y) 110 mm dia equal or unequal with oval access door complete all as specified and directed.
S&F PVC (SWR) branch piece (double Y) 75 mm dia equal or unequal with oval access door complete all as specified and directed.
S&F 110 mm bore size PVC (SWR) junction single(single T) equal or unequal with access door including jointing the same with solvent cement complete all as directed.
All as per item No 93 here -in -above but 75mm bore.
S & F in repairs PVC seat cover for EWC white / Black colour complete with MS Hinged cromium plated make as per existing all as specified and as directed
S&F in repair steel chromium plated gratings, circular type, 125mm dia with or without waste hole fixed to existing traps with white cement complete all as directed.
S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as directed.Make of cistern CERA Cat No B1010109 or equivelant of PARRYWARE/HINDWARE/PRAYAG
S&F in repairs stainless steel Kitchen plate rack of overall minimum size 900mm x 750mm and 250mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed. Note : Weight of rack shall not be less than 6.00 Kg. Make PRAYAG Cat No P-348 or equivelent of Nirali/Diamond
Dismantling of existing any type & any capacity water storage tank fixed in any description and stacking at site and S&F new 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover including PVC float valve high pressure suitable for 20 mm bore of pipe with polythene float, fixture hoisted and fixed in position where ordered and making necessary connection and testing complete all as directed.
Dismantling of existing any type & any capacity water storage tank fixed in any description and stacking at site and S&F new 1000 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover including PVC float valve high pressure suitable for 25 mm bore of pipe with polythene float, fixture hoisted and fixed in position where ordered and making necessary connection and testing complete all as directed.
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed
Removing complete shrubs/ vegetation upto root grown in any description such as grown in wall / beam / roof /chajja etc in height up to three storey building including filling the holes where the shurbs removed with cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) of minimum size 15cm x15cm x 15cm or as required and making good the distured surface as per its original specification to the satisfaction Engineer-in-charge& removal of the taken out shurbs out of MD land and disposed complete all as directed.
PRACHANIVA CONSTRUCTIONS
PRAGATHI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .