Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹33.1 L+₹94,337.30 (2.93%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹38.4 L+₹6.3 L (19.4%)Rejected-Finance 35 MODEL TOWN G T ROAD JANDIALA GURU DISTRICT AMRITSAR | JANDIALA GURU | AMRITSAR | PUNJAB | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹40.9 L+₹8.7 L (27.2%)Rejected-Finance H NO 1237 PANA PAPOSIAN NARELA NORTH WEST DELHI NEW DELHI 110 040 | NEW DELHI | NORTH WEST DELHI | DELHI | 110040 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹41.2 L+₹9.0 L (28.1%)Rejected-Finance RZ 382 3RD FLOOR GALI NO 11B KAILASH PURI EXTN PALAM COLONY PALAM VILLAGE NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹49.8 L
EMD Value
₹99,600
Closing Date
7 Sept 2023, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
REPAIR/REPLACEMENT OF ROOF SHEET INCLUDING TERMITE TREATMENT, ROOF TREATMENT CERTAIN B/R REPAIRS, MANGLORE PATTERN OVERHEAD TILES, BROKEN PLINTH PROTECTION AND OTHER CONNECTED EXTERNAL PERIODICAL WORK IN BAIRD PLACE AND IN THE AREA OF AGE B/R-II UNDE
2023_MES_607128_2
GE/DE-44/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹99,600
Yes
23 Oct 2023
10 Aug 2023
9 Sept 2023
10 Aug 2023
7 Sept 2023
31 Aug 2023
Amount
Dismantling/ taking out of existing roof tretment with APP membrane of any thickness including taking out existing sreed bed / rendering of any thickness wth all necessary arrangements complete all as specified and as directed.
M & L for providing and applying smart care Dampproof, a fidre reinforced elastometric liquid water prrofing membrane formulated with reinforced acrylic fibres having Sun Reflective Index (SRI) of 105 on horizontal/ vertical surfaces of roof/ wall/ chajjas in multiple costs @2.0 litre/ sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (Dilition with water in the ratio of 3:1, damp proof : Water) and other coat to be applied undiluted. The coating needs to be reinforced with 40GSM Geotextile, to sandwiched between 2nd &3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Cgarge. Make : SmartCare Damp Proof of Asian or equivalent in Berger/ Nerolac/ STP only. Notes: (1) The work shall be executed through authorised appplicatot of manufacturer only. (2) Authorised Applicator shall be approved by GE befor starting the work. (3) All materials shall be produced directly from manufacturer. The purchase voucher shall be produced to the Engineer-in-Cgarge for his verification of material. Engineer-in-Cgarge shall deface the original purchage vouchers. (4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water Proofingtreatment for a period of Eight years i fevour of GE. A sum equivelent to 2.5% ( Two point five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor's duues as security deposite. The contractor may, however, furnish a fixed deposite receipt in lieu from a Schedule bank pledged in fevour of Garrison Engineer.
M&L for PCC 1:2:4 type B -1 (using 20mm graded crushed stone agregate) as in roof slope and required, brushing neat cement slurry with 3.0kg of cement per sq. metre including necessary form work and scaffolding upto 2nd floor here required to match the existing surfaces rounded orchamfered on edges complete all as specified and directed.
M & L for priming over roof surface @ 0.25 Ltr/Sqm over a cleaned roof surface and applying one coat of bitumin painting with hot blown grade bitumin 85/25 @ 1.20Kg/ Sqmtr and laying of APP based polymetric membrane minium weight 3kg/ sqm and minium 3mm thick reinforced with polyster non wove febric ( wt not less than 150gms/ sqm) land on primed surface by forced application complete all as specified and directed. Notes: (1) The work shall be executed through authorised appplicatot of manufacturer only. (2) Authorised Applicator shall be approved by GE befor starting the work. (3) All materials shall be produced directly from manufacturer. The purchase voucher shall be produced to the Engineer-in-Cgarge for his verification of material. Engineer-in-Cgarge shall deface the original purchage vouchers. (4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water Proofingtreatment for a period of Eight years i fevour of GE. A sum equivelent to 2.5% ( Two point five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor's duues as security deposite. The contractor may, however, furnish a fixed deposite receipt in lieu from a Schedule bank pledged in fevour of Garrison Engineer.
M&L for preparation and applying two coats of aluminium paint over APP based polymetric membrane with required finishes complete all as specified and as directed.
Dismantling of Single layer Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as specified and directed.
M&L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry, pattern as approved by Engr-in-charge, complete all as specified and directed.
M&L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6, pattern as approved by Engr in Charge, complete all as specified and directed.
Dismantling of Battens for tiles, shingles etc, of any size including tilting fillets work Spaced exc 15 Cm in any position complete all as specified and as directed.
M&L for 2nd class Hard wood clean sawn battens at 20 cm centres to center as in battens for ceiling & lining fixed with nails sectional area exc 15 sqcm and n exc 25 sqcm complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed work complete all as specified and as directed.
M&L for Timber framed and fixed, Clean sawn, Second class hard-wood in scantlings work complete all as specified and as directed.
Demolition in cement concrete of cement concrete in ground floor and paving not exc. 15 cm thick below or above ground level all as specified
M&L for 75 mm thick in Plain cement concrete type C2 (1:3:6) (using 40 mm graded aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as directed at site.
Dismantling wall and ceililing boards (fibre, pulp, insulation etc. ) or insulation boards/ slabs/ blankets, any thickness, including cover fiilets complete all as specified and directed.
M&L of false ceiling in step(s) comprising of 12mm thick Gyp board including GI frame work for seamless ceiling made of GI perimeter channel 0.55mm thick with two unequal flange of 20 to 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screw at 450 mm centre to centre intermediate channel 0.9mm thick having two equal flange of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleats and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurledweb of 50mm and flangeof 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre with and including two coats of plastic emulsion paint incl dismantling wall & ceiling boards (fibre, insulation etc ) or insulation boards, slabs, blankets any thicknesscomplete all as directed. (Note:- The measurement shall be made from wall to wall flat.(Make: Diomand/Armstrong)
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and as directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour as approved having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and including cutting chasing of wall, complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in ridges of roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling wrought iron or mild steel work of any description complete all as specified
M&L for MS rolled section as in main and cross beams, hip and jack rafters , purlins, where connected to common rafter, post and running rails and guided for sliding doors fixed with angle cleats and other connecting plates conforming to Fe-290 (Gde E-165) complete all as specified.
M & L for providing and injecting chemical emulsion for post construction Anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. complete all as specified and directed.
M & L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc. complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M&L for brick work in CM (1:6) straight or curved on plan exc 6.0m mean radius and using old size sub class 'B' bricks all as specified.
Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
M&L for preparation of old decoreated external wall / Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible for G+8 storey building and applying two coats of weather proofing exterior acrylic emulsion paint over priming coat premium quality over wall / ceiling complete, including applying 2mm thick wall care putty over disturbed surface during preparation or any reason, complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
M&L for preparation of old decoreated external wall surface by mechanised sander of Berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible, applying 2mm thick wall care putty, again sand papering thus making surface smooth. and applying two coats of cement base paint on walls complete all as specified and all as directed by Engr-in-Charge .
M&L for prepration of old plstered surfaces of wall and applying two coat of white wash complete all as specified and all as directed by Engineer in charge .
M&L for Preparation of New/old painted surfaces of wood based surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of New/old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down cement plaster on brick walls, or stone walls / ceilings etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L 10-12mm thick polymer modified readymix cement base plaster as per manufacturer's instruction on fair / unfair faces of brick work or concrete surfaces including taking down plastering or any other treatment & finishing the surface even & fair as per manufacturer instruction complete all as specified & directed.
M&L for renderning 15 mm thick in CM 1:4 on any faces of brick/concrete surfaces finished even and fair with out using extra cement complete all as specified.
Taking down cement plaster /duster bed PCC of Column, chajja, Parpapets of roof, facia, drops etc and making good with cement plaster 10mm thick in CM 1:3 with PCC 1:2:4 type B1 (average thickness of PCC 25mm) as required, brushing with neat cement slurry @ 3.0 Kg of cement per Sqm including necessary form work and scaffolding upto 2nd floor including fixing of wire netting complete all as specified and directed
M&L for prepration of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed .
M&L for prepration of newly plastered surfaces of wall and applying two coats of weather proofing exterior acrylic emulsion paint premium quality on wall surfaces over one coat of primer from the same manufacturer complete all as specified and directed.
M&L for prepration of newly plastered surfaces of wall and applying 1mm thick birla white wall care putty complete all as specified and as directed.
M&L for removal of and loose peeling paints, up to true surface of wall / ceiling portion. Wash of all dirt, grease, soap and oil build - up with mild detergent, mildew with one part of bleach and three part of water. Rinse throughly and allow to dry. prepration complete all as specified and as directed.
Providing and applying high quality acrylic modified resin based texture of finetex Honeycomb sand stone- 3211with anti alage and UV resistance property to be applied as in intermeadite finishes in desired pattern @ 43.04 kg/10 sqm to form film of 1 - 1.50 mm thickness after scrapping and properly cleaning the surfaces to remove loose particles from the plaster surfaces and applying coating with premium acrylic smooth exteriorpaints with Silicone additives of required shade by two or more coat @ 1.43 Ltrs/ 10 sqm over and including one coat of premium quatity primer. Complete all as specified and as directed.
Providing and applying high quality acrylic modified resin based texture of Pebbletex bubble silver escapade M - 604 Pattern or other any shade / pattern with anti alage and UV resistance property to be applied as in intermeadite finishes in desired pattern @ 43.04 kg/10 sqm to form film of 1 - 1.50 mm thickness after scrapping and properly cleaning the surfaces to remove loose particles from the plaster surfaces and applying coating with premium acrylic smooth exterior paints with Silicone additives of required shade by two or more coat @ 1.43 Ltrs/ 10 sqm over and including one coat of premium quatity primer. Complete all as specified and as directed.
M&L for prepration of surface Texture / tiling on wall and ceiling for filling cracks with Smart care Textutred crack filler with following steps. 1) Open the Crack and widen it to form of V' shaped groove with help of Chisel. 2) Clean the area throughly so that it is free from dust and loose particles. 3) Apply a shelf priming coat (1:1) dilution with water ) of smart care textured crack filler over crack edges and allow to dry it for 1- 2 hrs. 4) Apply first coat of undiluted smart care Textured crack filler on the crack using spatula or putty Knife. 5) Press the paste firmly in the crack to ensure full contact with the surface .6) Spread Smart care Textured cracks Filler up to atleast 3 cm on either side of the crack for better adhesion. 7) Apply in consecutive prependiculkar layers to avoid leaving air pockets . 8) allow to dry for a minium 6 hrs. 9) apply the second undiluted coat in the in the same manner as required.
Disconnecting existing tanks exc 250 ltr n exc 500 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
Disconnecting existing tanks exc 500 ltr n exc 1000 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
Dismantling water tanks exc 250 Ltrs but not exc 500 ltr capacity and removing to store.
S&F rotantional moulded polythylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top ) hoisted and fixed in position complete with ball valve of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball and screwd for iron pipe 20mm bore omplete all as specified and directed.
Taking up or down steel tubing 15 mm bore and connection and removing from site.
Taking up or down steel tubing 20 mm bore and connection and removing from site.
S&F steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 15 mm dia.including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4 complete all as specified and as directed by Engineer-in-Charge
S&F steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 20 mm dia.including making hole in RCC slabs for vertical pipes & making good the same with Cement Concrete I:2:4 complete all as specified and as directed by Engineer-in-Charge
M&L for providing in manglor pattern tiles patches as in roof covering area exc 1 Sqm but n exc 2 Sqm each complete all as specified and as directed by Engr-in-Charge
R. S. Associates
STAR CONSTRUCTION CO
M/S HARINDER SINGH
A S CONSTRUCTION CO.
tarun construction co
SREE BABA TRADERS
sunil traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .