Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC | L1 | Accepted-AOC AOC AWARDED DUE TO L1 BIDDER | |
| 2 | L2₹50.5 L+₹2.5 L (5.28%)Rejected-Finance | L2 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE | |
| 3 | L3₹50.5 L+₹2.6 L (5.35%)Rejected-Finance | L3 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE | |
| 4 | L4₹50.6 L+₹2.7 L (5.61%)Rejected-Finance | L4 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE | |
| 5 | L5₹51.2 L+₹3.2 L (6.77%)Rejected-Finance | L5 | Rejected-Finance BIDDER REJECTED DUE TO HIGHER BID VALUE |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Jun 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL BIRENDRA SINGH
GE 859 EWS
PERIODICAL SERVICES REPAIR/MAINT OF DGSETS, AUTOMATIC/CONTROL PANELS, ALTERNATOR, EARTHING AND CONNECTED WORKS AT ELECTRIC INSTALATION UNDER AREAS OF AGE EM
2023_MES_596785_1
8426
Open Tender
Civil Works
Item Rate
270 days
BOMDIILA
PL REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 859 EWS
₹96,000
Yes
12 Jul 2023
19 May 2023
10 Jun 2023
19 May 2023
9 Jun 2023
2 Jun 2023
Amount
M&L for complete servicing by expert/auth service engineer once in quarter (three months or interval) including cleaning of engine with karosene or by blower where necessary, prevention of leakage of fuel / oil / water / coolant, tightening of loose nuts and bolts, retensioning of fan belt, descaling of radiator cleaning with cleaning agent, cleaning of fins by applying pressuried air using blower , checking of all electrical connections and testing on full load of DG Set 320 KVA, Make - Cummins, Greaves & Kirloskar installed at Rupa Power House, Chindit Top Power House and Dahung Power House. Note :- (i) Items like Nuts, Bolts, washers, benjo bolts required at site deemed to be included in this unit rate. (ii) Major spares required at site will be measured and paid separately. (iii) Fuel and lubricants required for inspection and testing will be supplied by the Deptt.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Lub Oil Bypass Filter element complete
Air Filter element
Fan Belt
Inhibitor Corrosion
Hose Pt No AK 5042 SS
Hose Pt No AK 6045 ST
Hose Pt No AK 10065 MS
Radiator Hose
All as per Item No. 1.00 above but for DG Set 100 KVA, Make : Kirloskar installed at AP Dukhampani and Nagpal Auditorium.
Fuel Filter element including 'O' ring complete
Fuel Filter water separator element complete
Lub Oil Filter element (Kirloskar Cat Part No - 06.436.01.0) complete
Air filter element (Inner & Outer)
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 100 KVA, Make : Cummins installed at Div HQ Sub Stn.
Fuel Filter element including 'O' ring complete.
Fuel Filter water separator element complete.
Lub Oil Filter element complete.
Air filter element Inner & Outer complete.
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 63 KVA, Make : Greaves installed at Div IIT.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element (Kirloskar Cat Part No - 06.436.01.0) complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 35 KVA, Make : Kirloskar installed at AP Dukhampani.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 160 KVA, Make : Ashok Layland installed at 5 MDSR.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 125 KVA, Make : Kirloskar and Mahindra & Mahindra installed at 46 Inf Bde & Transit Camp Baisakhi.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 82.5 KVA, Make : Kirloskar installed at 311 Inf Bde.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element (Kirloskar Cat Part No - 06.436.01.0) complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 63 KVA, Make : Kirloskar installed at Signal Centre 5 MDSR.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element (Kirloskar Cat Part No - 06.436.01.0) complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 250 KVA, Make : Cummins and Mahindra & Mahindra installed at Dahung Power House and 181 MH.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 160 KVA, Make : Kirloskar installed at 181 MH.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 125 KVA, Make : Cummins installed at 181 MH.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element (Kirloskar Cat Part No - 06.436.01.0) complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 40 KVA, Make : Kirloskar installed at GE 859 EWS.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element (Kirloskar Cat Part No - 06.436.01.0) complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 15 KVA, Make : Kirloskar installed at MES Offr Mess.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air filter element
Fan Belt
Inhibitor Corrosion
All as per Item No. 1.00 above but for DG Set 12.5 KVA, Make : Kirloskar installed at AGE B/R & E/M Office Complex.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air filter element
Fan Belt
Inhibitor Corrosion
M&L for complete servicing by expert/auth service engineer once in quarter (three months or interval) including cleaning of engine with karosene or by blower where necessary, prevention of leakage of fuel / oil / water / coolant, tightening of loose nuts and bolts, retensioning of fan belt, descaling of radiator cleaning with cleaning agent, cleaning of fins by applying pressuried air using blower , checking of all electrical/mechanical connections and testing on full load of Diesel Engine driven Pumping Set 127 BHP Capacity at Gachham Pump House and Birpur Pump House. Note :- (i) Items like Nuts, Bolts, washers, benjo bolts required at site deemed to be included in this unit rate. (ii) Major spares required at site will be measured and paid separately. (iii) Fuel and lubricants required for inspection and testing will be supplied by the Deptt.
Fuel Filter element including 'O' ring complete
Lub Oil Filter element complete
Air Filter element
Fan Belt
Inhibitor Corrosion
Disconnecting /unscrewing coupling for RKB 125/150 HP pump set and seperating Pump and Motor/Gen Set, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, for carry out the necessary repairs and , installing on existing location after repair,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under :-
Coupling Set suitable for RKB 125/150 HP Pumpping set.
Replacement of gun metal impeller
Replacement of gun metal Bush
Replacement of Gland Sleeve
Replacement of body Neck ring gun metal
Replacement of Pump shaft stainless steel
Key way of impeller disc
Balancing disc
Balancing ring
Taking out old unserviceable with replacement of ball bearing No 7311 BECBP, complete all as speciified and as directed. Make: SKF/ NBC
Taking out old unserviceable with replacement of roller bearing No NU411, complete all as speciified and as directed. Make: SKF/ NBC
Taking out old unserviceable with replacement of roller bearing No NU319EMZ1C3, complete all as speciified and as directed. Make: SKF/ NBC
Taking out old unserviceable with replacement of roller bearing No 6319C3, complete all as speciified and as directed. Make: SKF/ NBC
S&F Industrial Electronic Voltage Regulator (IEVR) suitable for DG Set 320 KVA including disementling and taking down old and unserviceable complete all as specified and directed.
M&L for Throttle control complete mechanism including leaver suitable for DG Set 320 KVA Model No. KT-1150G, Make : Cummins including disementling and taking down old and unserviceable complete all as specified and directed.
Taking down and repair to self starter of capacity 320 KVA DG Set by taking out defective parts and replacement of armature, field coils, carbon bush, pinion, shocker arm, bearing complete including testing complte all as specified and directed.
S&F Automatic Voltage Regulator (AVR) suitable for DG Set 160/100 KVA including disementling and taking down old and unserviceable complete all as specified and directed.
M&L for repairs to self starter 24 Volt including replacement of armeture, bushing, carbon bushes including testing on completion and fixing on existing position complete all as specified and directed by Engineer-in-Charge.
S&F for Fan Shaft suitable for DG Set 320 KVA Model No. KT-1150G, Make : Cummins including disementling and taking down old and unserviceable complete all as specified and directed.
M&L for Pillow block assembly suitable for DG Set 320 KVA Model No. KT-1150G, Make : Cummins including disementling and taking down old and unserviceable complete all as specified and directed.
M&L for shut down valve suitable for DG Set 320 KVA Model No. KT-1150G, Make : Cummins including disementling and taking down old and unserviceable complete all as specified and directed.
Taking out fuel pump for 320 KVA DG Set, transporting to auth workshop, dismantling of pump carefully and overhauling complete, replacement of complete pump kit, plunger kit, nozzle kit, caliberation with pump and plunger and all other defective parts of fuel pump including reassembling and refixing complete all as specified and directed.
S&F for replacement of battary 12 V 180 Ah maintenance free Make: Exide Express Cat No. XP-1800 or equivelent in TATA/ Amaron
M&L for replacement of fuel pipe from tank to filter as per sample to the existing complete all as specified and directed.
M&L for replacement of fuel pipe from filter to pump as per sample to the existing complete all as specified and directed.
S&F for replacement of battary 12 V 150 Ah maintenance free Make: Exide Express Cat No. XP-1500 or equivelent in TATA/ Amaron
S&F Water pump assembly complete assembly including fitting and fixtures as per site rquirement suitable for DG Set 320 KVA, Make Cummins including disementling and taking down old and unserviceable complete all as specified and directed.
S&F Self Starter suitable for DG Set 320 KVA including disementling and taking down old and unserviceable complete all as specified and directed.
S&F Self Starter suitable for DG Set 100 KVA including disementling and taking down old and unserviceable complete all as specified and directed.
Scraping of old existing paint, oil from body of alternator ,radiator, engine ,base frame including exhaust pipe/silencer, preparation of surface and filling of cavity using filler material and spray painting to complete DG set of capacity 320 KVA alongwith all accessories including fuel tank with two coats of super enamelled paint of superior quality as approved by AGE E/M and writing of MES/SM No. using black paint of suitable font of letters in background of white paint complete all as specified and as directed by Engr-in-charge.
Design, fabricate, supply and fix diesel tank of capacity 500 Ltr as per sample to the existing fabricated out of sheet steel having locking arrangement including measuring nib and outgoing valve arrangement upto generating set including suitable size pipe from tank to generating set, vertical type floor mounted on angle iron frame of ISA 75x75x6mm with minimum height as per site requirement, suitablily grouted to PCC complete incl dismentling existing one complete all as specified and directed.
Repair and caliberation of injector assembly including replacement of nozzle, spring, barrel plunger, injector cup complete and refitting to original position duly changing the worn out nut, bolts/studs etc complete by authorised service centre all as specified and directed by Engineer-in-Charge.
M&L for rewinding of alternator 320 KVA including transportation to workshop at Guwahat/Tezpur and back to existing location of Make - Kirloskar/Stamford with super enamelled copper wire of suitable sizes complete including heat varnishing and replacement of bearing DE and NDE and all other accessories such as vertex paper, ferrule, lugs etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix anti viberation pad to base frame of 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge
M&L for repairs to dynamo alternator 24 Volt including replacement of wiring, bearing, bushing including replacement of copper coil of suitable size and testing on completion and fixing on existing position complete all as specified and directed by Engineer-in-Charge.
NIHAR ENTERPRISE
M/S SANTOSHI TRADERS
SHRI RAJEN PASWAN
M/S BARUA REFRIGERATION WORKS
A K DUTTA CHOWDHURY AND CO
M/S BARUAH ELECTRICALS
M/S PAUL CONSTRUCTION
M/S S.S.Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .