Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹11.1 L (11.1%)Rejected-AOC | ₹1.1 Cr+₹11.1 L (11.1%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.1 Cr+₹13.3 L (13.3%)Rejected-AOC | ₹1.1 Cr+₹13.3 L (13.3%) | L3 | Rejected-AOC L3 |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
27 Jan 2021, 2:00 pmClosed
Superintending Engineer P.W.D.,Tezpur Road Circle,
Office of the Superintending Engineer P.W.D.,Tezpur Road Circle, Tezpur
Construction of Bowbajar Haldiabari Road under SOPD (G) for the year 2020-21 under Biswanath District Territorial Road Division, Biswanath Chariali Municipal Board. Package No TRC/SOPD-G/BIS/12
2021_PWD_20094_3
TRC/TB/SOPD(G)/04/BIS/2020-21
Open Tender
Civil Works – Roads
Item Rate
120 days
Biswanath
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,500
Empowered Officer, ASRB, Guwahati
₹2.2 L
Yes
6 Sept 2021
11 Jan 2021
29 Jan 2021
12 Jan 2021
27 Jan 2021
13 Jan 2021
Amount
Clearing and grubbing road including uprooting rank vegetation, grass, and trees of girth upto 300 mm, removal of stumps of such trees cut earlier as per Technical Specification Clause 201. (i) By Manual Means A) In area of light jungle.
Construction of subgrade and shoulders with approved material obtained from borrow pits and compacted to meet requirement of Table 300.1 and 300.2 (a) From Private land
Construction of Granular Sub-Base (GSB) by providing well graded materials, spreading in uniform layers at OMC... to achieve the desired density, completed as per Technical Specification Clause 401. (ii) Grading II Material
Providing laying, spreading and compacting stone aggregate of specific sizes to WBM specification and compacting to the required density etc. as per Technical Specification Clause 405. By Manual means (iii) Gr-III materials
Providing and laying coloured interlocking block pavement (M40) having thickness 80mm as per Technical Specification Clause 1504 complete including carriage. (a) Including Edge block/Edge restrainsts
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per Technical Specification Clause 1504. Complete including carriage. (a) Including Edge block/Edge restrainsts Yellow Inter Locking Paver Block (For PWD)
White Inter Locking Paver Block (For PWD)
A. Retro-reflectorised Traffic Signs I. Providing and fixing retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (i) 60cm equilateral triangle.
(ii) 60cm circular
Planting of Trees and their Maintenance for three Years (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling etc...
1000mm Dia Hume Pipe Culvert Earth work in excavation of foundation of structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m dressing of sides and bottom and backfilling in trenches with excavated suitable material. 1) Ordinary Soil (i) Upto 3.0m depth
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specifications Clause 802, 803, 1202 & 1203 with crushed stone. PCC grade M10: Nominal Mix 1:3:6
Brick masonary work in Cement mortar 1:3 in foundation complete excluding pointing and plastering, as per drawing and technical specifications clauses 600, 1202 & 1203
Brick masonary work in Cement mortar in Sub-Structure: Brick masonary work in Cement mortar in Sub-Structure complete excluding pointing and plastering, as per drawing and technical specifications clauses 602, 603, 604, 1202 & 1204
Providing and laying Reinforced cement concrete pipe NP3 prestressed concrete pipe for culverts on first class bedding of granular material /cc M-15 in single row including fixing and cost of granular bedding but excluding excavation, protection works, backfilling, concrete and masonry work in head wall and parapet, cost of pipe and cost of cc bedding. (I) With 1st class bedding of granular material 1000 mm dia
Plastering with cement mortar (1:4), 15mm thick on brick work in sub-structure as per Technical Specification Clauses 613.4 & 1204
SAMIRAN INFRASTRUCTURE PVT LTD
DIKU MONI CHOUDHURY
stage.html
html • 0.05 MB
tech_bid_open
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .