GE AF OJHAR
GE AF OJHAR
Repair Maintenance of internal electrificaation summer cooling appliances celing fans external electric services HT LT cables panel board street light at chamarlene Borgad top at AF stn Borgad
2021_MES_421955_2
8719/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
BORGAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹28,000
Yes
15 May 2021
15 Mar 2021
31 Mar 2021
16 Mar 2021
29 Mar 2021
17 Mar 2021
60 days
Amount
M & L Cable end termination heat shrinkable out door type complete with jointing material and aceessories suitable for 11000 V , three core 95 sqmm XLPE armouredc aluminium cable Make : Raychem/Denson / G-Seal complete all as specified & as directed by Engineer-In-Charge (Note: For Sl No 1 to 142 if any of following work / troubleshooting / complaint not rectified within 24 hours with user satisfactory working report, penalty of Rs. 500/- per defect per day shall be recovered from contractor.)
M & L for Cable jointing kit heat shrinkable straight through type complete with jointing material and accessories suitable for 11000V, three core 95 sqmm XLPE armoured aluminium cable of Make : Raychem/Denson / G-Seal complete all as specified & as directed by Engineer-In-Charge
M & L Cable end termination heat shrinkable indoor type complete with jointing material and aceessories suitable for 11000V , three core 95 sqmm XLPE armoured aluminium cable Make : Raychem/Denson / G-Seal complete all as specified & as directed by Engineer-In-Charge
Material and labour for cable joint termination box FRP body housing suitable for housing and including 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply including taking down old unserviceable pole box from existing position complete all as as directed by Engineer-in-charge.
Supply and fix cold shrinkable cable jointing kit for 1100 Volt gade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE/PVC insulated armoured aluminium conductor cable of size 50 Sqmm , complete all as specified and directed by Engineer-in- Charge
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable with stranded aluminium conductor 1100V grade 3.5 core cross sectional area 35 sqmm, complete all as specified and directed by Engineer-In-Charge.
Supply and lay in repair XLPE insulated,armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 3.5 core ,70 Sqmm cross section complete all as specified and as directed by Engineer-In-Charge.
Supply and lay in trenches/ducts or passing through pipe in repair ,testing & commissioning LTUG cable 4 core 10 Sqmm, 1100 volt grade, XLPE insulated armoured (heavy duty) stranded aluminioum conductor complete all as specified
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size ID 75 mm
Excavation in trenches n. exc 1.5 Mtr width and n.exc 1.5 mtr deep for foundation, laying GI pipes in in hard dense soil, complete all as specified and as directed by Engineer-In-Charge.
Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 mm levers of soil, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.
Supply and fix in repair Switch piano flush button single pole one way 5 amps of Make : Anchor /Crabtree/Rio ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repairs Switch piano flush button single pole one way15 amps Make : Anchor /Rio ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell push flush type 5 Amps. Make : Anchor/Havells Rio.
Supply and fix in repair Modular bell push 6 Amp,1 Module , Make Anchor/ Roma/Legrand.
Supply and fix in repair Socket out let 2 in 1, 5 pin 5 Amps flush type ,complete all as specified & as directed by Engineer-In-Charge. Make : Make AnchorRoma /Legrand/Rio
Supply and fix in repair Socket out let 2 in 1, 3 pin 5 and 15 Amps combined flush type ,complete all as specified & as directed by Engineer-In-Charge. Make : Make Anchor Roma /Legrand/Rio
Supply and fix in repair Ding Dong bell AC 230 Volts single pole ,complete all as specified & as directed by Engineer-In-Charge. Make : Anchor/Press Fit
Supply and fix in repairs Fan Capacitor 2.5 to 10.0 mfd AC 230 volts ,complete all as specified & as directed by Engineer-In-Charge.Make: Epcos
Supply and fix in repair Modular Fan regulator electronic step type 230 V 2 Module ,complete all as specified & as directed by Engineer-In-Charge. Make : Anchor/Roma/Legrand
Supply and fix in repair Fan regulator electronic step fiush type 230 V 300W ,complete all as specified & as directed by Engineer-In-Charge. Make : Anchor/Havells Rio.
Supply and fixing in repair sheet metal enclosure for DBs when MCBs to be used single pole and neutral IP 43 IK-09 protection with acrylic door, 240 volt with 200 amps rated bus bar bar 8 way of Make Legrand Cat No 607721 or equivalent model of L&T/Siemens complete all as specified & as directed by Engineer in charge.
Supply and fix in repair sheet metal enclosure for DBs when MCBs to be used single pole and neutral with acrylic door IP 43 protection, 240 volt with 200 amps rated bus bar bar 4 way of Make Legrand Cat No 607720 or equivalent model of L&T/Simens.
Supply only in repair sheet metal encloser distribution board 415volt, Vertical TPN 4 Way with provision for DH 100 series MCCB of legrand make as incomer and SP/ TP MCBs as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface /reccess mounting IP-43 protection of L&T Cat No LTVD04MGN or equivalent in Legrand / Siemens, complete all as specified and as directed by Engineer-in-Charge.
M&L in repair wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLS) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x6.0 Sqmm+1x6.0 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position, complete all as specified and directed by Engineer-In-Charge (Note: 2 run of 6.0 sq mm & 1 run of 6 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
M&L in repair wiring wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLS) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x4.0 Sqmm+1x4 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position ,complete all as specified and as directed by Engineer-In-Charge (Note: 2 run of 4.0 sq mm & 1 run of 4 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
M&L in repair wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLS) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x2.5 Sqmm+1x2.5 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position ,complete all as specified and directed by Engineer-In-Charge.(Note: 2 run of 2.5 sq mm & 1 run of 2.5 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
Supply and fix in repair decorative ultra slim square profile linear TRIM LINEA lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 20W LED 6000K, complete with connecting accesseries duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No LCTLN-20-CDL or equivalent in Philips/ Havells.
Supply and fix in repair decorative ultra slim square profile linear TRIM LINEA lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 10W LED 6000K, complete with connecting accesseries duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting complete all as specified and directed by Engineer-in-Charge. MAKE :Crompton, Model No.LCTLN-10-CDL or equivalent in Philips/ Crompton Greaves.
Supply and fix in repair decorative ultra slim square profile linear TRIM LINEA lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 5W LED 6000K, complete with connecting accesseries duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting complete all as specified and directed by Engineer-in-Charge. MAKE : CROMPTON, Model No. LDL-05-CDL or equivalent in Philips/Havells.
Supply and fix in repair New generation energy saving & enviromental friendly long life versatile pressure die cast aluminium IP65 with high power road way luminaire FREEDOM NEO LED with SPD street light fitting, lamp type 45W LED 6000K , deep drawn aluminium pipe mounting attachment complete and connecting with 3 core PVC insulation PVC sheathed copper cable of size 1.5 Sqmm from junction box to street light and testing complete model No LSTS-45 -CDL_M Asymmetric optics of Make : Crompton or equivalent in Philips/Havells including taking down old unserviceable fitting from existing position complete all as specified & directed by Engineer-In-Charge.
Supply and fix in repair CCR127-36-57-SL-NWH 6000K Ultra modern recess mounting luminare suitable for armstrong/ grid/ POP ceiling complete with separate electronic driver & high brightness SMD LEDs, complete with connecting accesseries & Driver duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting, complete all as specified and directed by Engineer-in-charge. MAKE : Crompton , Model No. LCTLRN-36-CDL or equivalent in Bajaj/Crompton Greaves.
Disconnect and insulate electric supply wire and taking down carefully ceilling/ exhaust fan of any make and sweep dismantlling blades, check for repairs required,Complete all as specified & as directed by Engineer-In-Charge. ( Note: Repairs/ Replacement of spares shall be carreied under appropriate items)
Hanging/fixing only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from ceiling rose to fan connector and testing ,Complete all as specified & as directed by Engineer-In-Charge.( Note: The fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc.)
Hanging/fixing only exhaust/cabin/wall fan of any make or sweep connecting up complete with and including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from celing rose to fan connector & testing ,Complete all as specified & as directed by Engineer-In-Charge.. ( Note: The fan shall be fitted with new set of washers, nuts, rubber reels, shackle etc.)
M&L for servicing opening up of fan, motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning for celling fan 1200 mm sweep,Complete all as specified & as directed by Engineer-In-Charge.
M&L for servicing opening up of fan, motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning for Exhaust fan 300/380/450mm sweep,Complete all as specified & as directed by Engineer-In-Charge.
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc for ceilling fan 1200 mm sweep complete all as specified and directed by Engineer-in-Charge.
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc for Exhaust fan of any sweep sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix bearing in repairs for replacement for ceilling fan 1200 mm sweep
Supply and fix bearing in repairs for replacement for Exhaust fan of any sweep
Supply & Fix in repair decorative Post top lantern MAPLE LED suitable for 360° indirect light with IP 65 protection resistant to impat and corrossion ,Glare free and better Uniformity with LED40 Watt of Make Crompton Cat Part No LPTO-40-CDL or equivalent in Phillips/havells .complete all as specified and directed by Engineer- in-charge.
Supply & Fix in repair Post top lantern decorative HERITAGE LED with IP 65 RATED led post top with opel deffuser including LED 20 Watt of Make Crompton Cat Part No LPTH-20-CDL including its pedestal duly fixed in the PCC using or equivalent in Phillips/ Wipro.complete all as specified and directed by Engineer- in-charge.Note:-Warranty for light fitting should be three yrs.Note:-Warranty for light fitting should be three yrs.
Taking down existing copper/aluminum point wiring (light/ fan/ socket or power points) complete including (fittings such as switches, ceiling roses, pendents, regulators, sockets, Light fitting etc including wooden battens /casing /capping and conduit etc and making good disturbed surface of walls, ceilings and floors etc. complete all as specified & as directed by Engineer-in-Charge.
Point wiring with 1.5 Sqmm (nominal area) PVC( Antitermite ecofriendly FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
All as per item No 46 here-in-before but for one 3 pin 5 Amps socket outlet on independent board.
All as per item No 46 here-in-before but for one 3 pin 5 Amps socket outlet on the sameboard with other switch with 1.5 sq mm size.
Point wiring with 2.5 Sqmm (nominal area) PVC( Antitermite ecofriendly FRLS) insulated sheathed copper stranded conductor cable run in and including concealed PVC conduit with all fittings such as bends, tee,junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including sunken box with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators, etc complete all as specified and as directed by Engr -in -Charge.
Supply & fix in repair Modular switch one way 6 Amp,1 Module , Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supplying and fixing in repair Modular socket, 6 amps-2/3 pin combined, 2 Module, Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supplying and fixing in repair Modular switch , one way, 16 amps, one Module of Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supplying and fixing in repair Modular socket 16 amps-6 pin multipin, 2 Module of Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supply & Fix in repair Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm two to three terminals. Make : Anchor/Leader, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair MCB SPN 32 amp 240 V,10KA, C curve,DX3 series of Make Legrand cat part no 408617 complete all as specified & as directed by Engineer in charge.
Supply and fix in repair MCB SP 6-32 amp 240 V,10KA, C curve,DX3 series of Make Legrand cat part no 408595 complete all as specified & as directed by Engineer in charge.
Supply only in repair Oil immerge fuse link of 20 to 63 Amp ,complete all as specified & as directed by Engineer-In-Charge. Make : GE / MEI / C.G Loosy
Supply only in repair Insulators pin type porcelain viterous white brown or green including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 150 mm height,150 mm dia for 11000 volts grade ,complete all as specified & as directed by Engineer-In-Charge.
Supply only in repair Insulators disc type porcelain viterous white brown or green 145 mm height, 225 mm dia ball and socket for 11000 volts grade single disc assembly ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 32 to 63 Amps 240 volts 10 KA C series ,complete all as specified & as directed by Engineer-In-Charge. Make : Standard/ HPL/ Legrand.
Supply and fix in repair Moulded case circuit breaker 415 volts three pole of repturing capacity 25 KA complete of capacity 200 Amps,type DPX 3 MCCB ,cat part no 420208 of Make Legrand or Equivalent in Siemens/L&T ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Moulded case circuit breaker 415 volts three pole of repturing capacity 25 KA complete of capacity 250 Amps,type DPX 3 MCCB ,cat part no 420209 of Make Legrand or Equivalent in Siemens/L&T ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Moulded case circuit breaker 415 volts three pole of repturing capacity 36 KA complete of capacity 400 Amps,type DPX 3 MCCB ,cat part no 422002 of Make Legrand or Equivalent in Siemens/L&T ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCCB Four Pole,415 V with rupturing capacity of 16 KA, 100 Amps DPX3 160 series, IP 43 IK 09 protected,enclosed in sheet metal encloser of Make: Legrand Cat part no 420015 ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Contactor for fully automatic star delta starter complete with operating coil 230 volts, 3TF52- 02-0AP0 ,2 NO+ 2 NC of Make Siemens or equivalent in L&T/Legrand complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Contactor for fully automatic star delta starter complete with operating coil 230 volts ML 2 ,2 NO+ 2 NC cat part no SS90701 of L&T or equivalent of Telemechanic,Siemens, Cutler hammer,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Relay for automatic star delta starter fully automatic suitable for up to 25 HP motor Make L&T ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Timer for automatic star delta starter fully automatic suitable for up to 25 HP motor ,complete all as specified & as directed by Engineer-In-Charge.
Material and labour for repairing LED street light 70 W fitting including taking down the unserviceable fitting from pole ,carring out complete comprehensive maintenance/Replacement of driver with new philips Make driver/unserviceable LED strip , refixing the same at desired height and making necessary electrical connections complete all as specified & as directed by Engineer-In-Charge.
Material and labour for repairing LED street light 200 W fitting including taking down the unserviceable fitting from pole ,carring out complete comprehensive maintenance/Replacement of driver with new philips Make driver/unserviceable LED strip , refixing the same at desired height and making necessary electrical connections complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair single phase Time switch with synchronus timmer resetable from digital display HPL, GIC, CH, Siemens ,complete all as specified & as directed by Engineer-In-Charge.
Material and labour for repair,cleaning ,servicing of all the parts and carring out "B" check of 15 KVA DG set Engine Model No X2.5-G2 of Make CUMMINS INDIA LTD & alternarnator Model no PI044G of Make STAMFORD,servicing of AMF panel and other auxilary units,commissioning and test run from authorised dealer of company complete all as specified & as directed by Engineer in charge.(Note :Spares required in the process of maintenance will be measured and paid separately but cost of labour charges for fixing are deemed to be included under quoted rates)
Supply only in repair primary fuel filter element cat part no 0149-2827 of Cummins complete all as specified & as directed by Engineer in charge
Supply only in repair secondary fuel filter element cat part no 0149-2828 of Cummins complete all as specified & as directed by Engineer in charge
Supply only in repair oil filter element cat part no 0122-0922 of Cummins ,complete all as specified & as directed by Engineer in charge
Supply only in repair air cleaner element cat part no 0140-4088 of Cummins ,complete all as specified & as directed by Engineer in charge
Supply & top up 8 litre of premium blue valvoline engine oil enclosed in plastic container,cat part no 503951 of Cummins complete all as specified & as directed by Engineer in charge
Material and labour for repair,cleaning ,servicing of all the parts, carring out "B" check of 63 KVA DG set Model No KG1 62.5WS including alternarnator & other auxilary units ,commissioning and test run from authorized rep of company complete all as specified & as directed by Engineer in charge.(Note :Spares required in the process of maintenance will be measured and paid separately but cost of labour charges for fixing are deemed to be included under quoted rates)
Supply and top up 15 litre of engine oil enclosed in plastic container of Make: Mico Bosch complete all as specified & as directed by Engineer in charge
Supply only in repair oil filter spin complete all as specified & as directed by Engineer in charge
Supply only in repair diesel filter complete all as specified & as directed by Engineer in charge
Supply only in repair air filter element complete all as specified & as directed by Engineer in charge
Supply only in repair FEW oil seal complete all as specified & as directed by Engineer in charge
Supply & top up 5 litre coolant enclosed in plastic container of Make Mico-Bosch
Supply and fix in repairs, battery 12 volt, 100 AH flooded type duly charged Make:- Tata BP Solar/Bosch,/Amaron complete all as specified and as directed by Engineer-In-Charge
General servicing Split AC capacity 1.5/2T ,dismantling unserviceable part of unit including cleaning of air filter,display,PCB,de-dusting of complete(indoor/outdoor) unit ,checking electrical connections & rewiring ,greasing of movable parts for getting trouble free service & making Split AC serviceable complete all as specified and directed by Engineer-In-Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor of 1.5 T split air conditioner Make: Kirloskar complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor of 2.0 T for split air cinditioner Make:Kirloskar complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new fan motor 1/3 Hp ,230 v for split AC Make AUE or equivalent including taking down old unserviceable fan motor from existing position complete all as specified and as directed by Engineer -in Charge.
Repairs to split AC of 1.5/2 T capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling for the following complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only running capacitor for split Air conditioner 1.5 T/2 T of capacity 36/45 mfd , 7 point ,440 VAC Make Epcos ,complete all as specified and as directed by Engineer -in -Charge
Supply only starting capacitor for split Air conditioner 1.5 T/2 T of capacity 80/100 mfd 440 VAC Make Epcos, complete all as specified and as directed by Engineer -in -Charge
Supply only Relay (8500-4) (Make Annapurna) suitable for Air Conditioner mentioned above, complete all as specified & as directed by Engineer-In -Charge.
Supply only remote control switches 1.5 Ton to 3 Ton capacity split A/C of any make as existing sample complete all as specified & as directed by Engineer-In -Charge.
Supply only blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR, complete all as specified & as directed by Engineer-In -Charge.
All as per item no 97 here-in before but for 2 TR complete all as specified & as directed by Engineer-In -Charge.
Supply only Bush with Blower shaft assy complete,1.5 Ton to 3 Ton capacity split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
Supply only Printed Circuit Board (PCB) For split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
Repairs to Circuit of existing Printed Circuit Board (PCB) in split type AC of any make, complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified by Engineer-In Charge
Supply and fix in repair condensor coil of Aluminium suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as specified & as directed by Engineer-In Charge.
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 1/4 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
Repair to refrigerator of capacity 165/210/310 litres ,General servicing,dismantling unserviceable part of refrigerator, checking electrical connections & rewiring,cleaning of refrigerator unit ,and making refrigerator serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor unit (type 1/8 ) Make-L51Q,66Q,Kirloskar,Suitable for 210 litre refrigerator of Godrej,Whirlpool, Videocon & LG complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor unit (type 1/6 ) Make-L51Q,66Q,Kirloskar,Suitable for 310 litre refrigerator of Make Godrej,Whirlpool, Videocon & LG complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Repairs to refrigerator after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only over load protector of various capacities for the cooling appliances, complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for the cooling appliances , complete all as specified & as directed by Engineer-In -Charge.
Supply only copper strainer and capillary tube suitable for refrigerator mentioned above Godrej,Whirlpool, Make : KISHCO / MB CAPIALLARYGodrej,Whirlpool, in replacement of unserviceable strainer & capillary complete all as specified & as directed by Engineer-In -Charge.
Supply only relay suitable for 1/8 and 1/6 compressor of capacities for the cooling appliances,complete all as specified and directed by Engineer in Charge
Repair to Deep freezer of capacity 265/ 320 /500 ltrs ,general servicing ,dismantling unserviceable part,checking electrical connections & rewiring,cleaning of deep freezer unit ,reassembling & making deep freezer serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed compressor unit Kirloskar or 91Q,110 of Godrej (with Relay unit) for deep freezer of capacity 265 ,320 litre complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only fan motor 1/35 HP suitable for deep freezer of capacity 265/300/320 litre , fan motor AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only capillary tube and silica drier type strainer suitable for Deep Freezer 265/320/500 litre capacity (Make - Blue Star & Voltas) ,complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for the cooling appliances for deep freezer upto 500 litre capacity, complete all as specified and as directed by Engineer -In-Charge.
Supply only relay suitable for 1/8 and 1/6 compressor of capacities for Deep freezer upto 500 litre, complete all as specified and as directed by Engineer in Charge
Repairs to Deep freezer after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressere, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Repair to storage type water cooler of capacity 40/80 & 60/120 ltrs , general servicing ,dismantling unserviceable part, checking electrical connections,cleaning internally and externally ,cleaning of water tank,tray & water outlet scraping with emery paper filling putty wherever required and painting with one coat of red oxide and two coats of synthetic enamel paint of approved colour and reassembling marking of MES/SM No in 25 mm size alphabetes,reassembling, refitting & making water cooler serviceable, complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor in exchange of existing unserviceable sealed unit compressor Make : godrej 91Q,Kirloskar 4440 M,Kirloskar 446, Kirloskar 443 suitable for water cooler suitable for water cooler of capacity 40/80 litre complete all as specified & as directed by Engineer-In -Charge.
Supply only new sealed unit compressor in exchange of existing unserviceable sealed unit compressor Make : godrej 91Q,Kirloskar 4440 M,Kirloskar 446, Kirloskar 443 suitable for water cooler of capacity 60/120 litre complete all as specified & as directed by Engineer-In -Charge.
Supply only fan motor 1/64 HP suitable for water cooler of capacity 40/ 80 lit AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only fan motor 1/32 HP suitable for water cooler of capacity 60 / 120 lit , AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for water cooler AC single phase 230 V of make INDFOSS or Equivalent make, complete all as specified and as directed by Engineer In Charge.
Supply only over load protector of various capacities for for water cooler of capacities 60/120 litre,AC single phase 230 Volt, complete all as specified & as directed by Engineer-In -Charge.
Supply only Starting capacitor for water cooler of capacity 60 mfd Make : Epcos or equivalent , complete all as specified and as directed by Engineer -in -Charge
S&F in repair Set of Copper pencil strainer suitable for Water Cooler mentioned above including taking down old unserviceable copper pencil strainer, complete all as specified and as directed by Engineer-In-Charge. (Make - KISHCO/ MB CAPPALLARY)
Repairs to water cooler after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Material & Labour for Preparation of old painted surfaces of concreate poles HT/LT , 9 Mtr long and painting with two coats of weather proof apex paint white coloured with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, Also marking of pole numbers in white with black background rectunglar/eleiptical on pole,also painting the cross arm with silver paint complete , complete all as specified & directed by the Engr-in-Charge.
Material & labour Preparation of old painted steel surfaces pole HT/LT (of any crooss section) of 9 meter length of aloong with cross arms, bracings supports of steel poles by scrapping out existing paint,applying red oxide primer on pole surface and painting two coats of aluminium paint with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, ,complete all as specified & as directed.
Material & labour for carring out fault detection of HT XLPE electrical cable located inside 793 SU/af station ojhar complex through cable fault detector van of MSEDCL (testing division),identifing the the fault carring out necessary exacavation for verification of fault& fault confirmation , complete all as specified and as directed by Engneer-in-Charge.
Material & labour for carring out fault detection of LT XLPE electrical cable located inside 793 SU/AF station ojhar complex through cable fault detector van of MSEDCL (testing division),identifing the the fault carring out necessary exacavation for verification of fault& fault confirmation , complete all as specified and as directed by Engneer-in-Charge.
Onload Filteration & dehydration transformer oil by onload filtreation plant machine to achieve minimum 40 KV di-electic strenth complete & testing the contents of acid before & after filteration at diffrent location of borgad Adm & technical area at 11 KV/440 V substation site by electrically operated transformer oil filetration equipment to achieve di electric strength as specified
Material and labour for cable joint/root indicator casted in 350x200x50mm PCC tile duly engraved with 'HT CABLE/LT CABLE / HT CABLE JOINT" in letters duly fixed into the ground with to th minimum depth of 450 mm, PCC casting (1:4:8), type D2 with 20 mm graded stone aggregate minimum size of PCC,duly painted, complete all as specified and as directed by Engneer-in-Charge.
Material and labour for repair,cleaning ,servicing(replacement of Oil filter,Air Filter & Fuel filter,coolent replacement) of all the parts f 40 KVA DG set Engine Model No S3 8G4 of Make CUMMINS INDIA LTD & alternarnator Model no PI144J1 of Make STAMFORD servicing of AMF panel of make YUGANDHAR checking complete wiring & VMR & controller,replacement of existing controller with PS 500 controller of Make powerstart and controller caliberation to synchronised all safety parameter of 40 KVA DG sets and other auxilary units,replacement of existing three phase contactor with new contactor of 100 amps capacityof Make : Siemens/L&T/Legrand & replacement of Low lube oil pressure switch,Replacement of solenoid switch ,recrimping of cable,rewiring with new set of wiring of suitable size, recommissioning and test run from authorised rep of company of company,testing for following parameter i) High water temperature ii)Low oil pressure trip iii)High voltage trip iv) Under Voltage trip iii) Under Frequency trip,submitting its service report complete all as specified & as directed by Engineer in charge.
M&L for carrying out physical inspection and measurement of individual earth pit resistance of each earth pit, every month located in area and maintain the record of its reading month wise and submit this office monthly for measuring the resistance of individual electrode of LV distribution system (using recently caliberated Digital Earth tester with test report )and other non-DG/ Transformer by fall of potential test in case fall of potential method is not possible at certain locations then measurement of earth pit resistance shall be carried out in stake less method using current and voltage clamps. Total 35 Nos earth pit located in different area of this station shall be measured in each month or all as directed. Pit for measurement of pit resistance including necessary excavation in any type of soil, or braking of hardstanding for inserting of spikes complete all as directed by Engineer-in-Charge. The rate also include to inspect and measure resistance of any type of earth( like conventional or chemical, strip or wire any size) complete. Note- Minimum 22 Earthings per working day and 100 % within a month to be cheked and testing will be carried out, testing equipment should be calibrated and certified from appropriate Govt Authority. Testing of earth resistance should be carried out in presense of the users and record should be furnished to the AGE E/M Office on daily basis, Failing which a recovery @ Rs 500 per eathing per day will be recovered as penalty.
M & L for earth enhansing material/Backfill Compund of A+ Grade available in 25 Kg packaging bag (mineral filled compound)for lowering the resistivity of the soil of existing earth pit against the higher resistance. The back fill compound should strictly be a Activated Carbon based conductive type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 -2000 standard. Tested as per IEC ; 62561-7 and the test certificates shall be submitted. Shall not depend on the continuous presence of water / moisture / salt to maintain its conductivity. Shall not decompose or leach out with time. Shall contain a corrosion inhibitor to prevent corrosion of copper. Shall not contain hazardous chemicals and necessary Test certificate from reputed accredited laboratories shall be furnished. Shall not be affected by drought and shall be stable between -10˚ to +50˚ C temperature. Shall be suitable for any kind of soil. Shall be supplied in sealed, moisture proof bags. These bags shall be marked with Manufacturer’s name or trade name, quantity, batch no & date of manufacture. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. , disconnting or reconnecting strip with nuts & bolts complete all as directed by Engineer- in-Charge. Note - Earth work and excavation will be measured separately , The above item will be executed for existing copper earthing only . copper plate will be cleaned by chemical/ grinding machine , upto satisfaction level of Engr-in-charge / GE. . Make :- JEF ECO SAFE / KAPILANSH/INDELEC SA
Material & Labour for isolating HT/LT electric connections cable from transformer of capacity 11 KV/433 Volt 100 KVA taking down step down transformer of 100 KVA located at KV school from the existing foundation & loading with the help of crane,transporting the same from to sewage treatment plant location, unloading with the help of crane placing on the platform with installing with firm Base/fitting/Fixture, Connecting of all HT/LT electric cable cable connection /Earthing strip to transformer located at New location recommissioning and testing ,complete all as specified & as directed by Engineer-In-Charge.
Material & Labour for isolating HT/LT electric connections cable from transformer of capacity 11 KV/433 Volt 50 KVA taking down step down transformer of 50 KVA located at Sewage treatment plant from the existing foundation & loading with the help of crane,transporting the same from to KV location unloading with the help of crane placing on the platform installing with firm Base/fitting/Fixture, Connecting of all HT/LT electric cable cable connection /Earthing strip to transformer located at New location ,recommissioning and testing ,complete all as specified & as directed by Engineer-In-Charge.
Supply & Fix in Repair cylindrical fues of capacity 32 Amp ,415 Volts of size 10 x38 of Make:Siemes/L&T/GE Power complete all as specified & as directed by Engineer-In-Charge
Material & Labour for servicing of voltage stabilizer for automatic operation SP 50 HZ, 220 V voltage variation between 90-300 V 5 KVA, repair / replacement of its PCB, timer (Time Delay) transformer circuit( Step up / step down), relay, diode & making its serviciable for stabilize power supply of 220 V complete all as specified and as directed by Engineer- in - charge.
DIAMOND ENTERPRISES
Datar Electrical and Engg Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .