Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.0 LAccepted-AOC | L-1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L-2₹39.0 L+₹5.0 L (14.7%)Rejected-Finance 261 BHARAT NAGAR BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-2 | Rejected-Finance Not being lowest bidder | |
| 3 | L-3₹39.3 L+₹5.3 L (15.6%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L-3 | Rejected-Finance Not being lowest bidder | |
| 4 | L-4₹44.6 L+₹10.7 L (31.4%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L-4 | Rejected-Finance Not being lowest bidder |
Tender Value
₹50.1 L
EMD Value
₹1.0 L
Closing Date
29 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda Bathinda Mil Stn
REPAIR/MAINT OF HT NETWORK AND CONNECTING ITEMS UNDER GE (U) BATHINDA AT BATHINDA MIL STN
2023_MES_634205_1
CWE BTD/TOKEN-59/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (U) Bathinda
₹1.0 L
HQ CWE Bathinda
28 Feb 2024
23 Dec 2023
31 Jan 2024
23 Dec 2023
29 Jan 2024
15 Jan 2024
2 Jan 2024
Amount
Dismantling of old unservicable ACSR conductor complete all as specified and directed by Engineer-in-charge.
Dismantling of insulators of any type, any size complete all as specified and directed by Engineer-in-charge.
Dismantling of old unservicable cross arms of MS channel or angle section etc.complete from LT /HT poles complete all as specified and directed by Engineer-in-charge.
Dismantling of old unservicable PCC pole of any size complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide, and not exceeding 1.5 metre in depth in soft / loose soil for foundation, laying of cables or pipes (where provided) for protection of cable or fixing poles and stays and struts and including trimming of sides and forming bottom surfaces to required level complete all as specified and directed by Engineer-in-charge.
Returning filling in, including spreading , leveling, watering and well ramming in layers each not exceeding 25cm thick in soft / loose soil complete all as specified and directed by Engineer-in-charge.
Removal of surplus excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed by Engineer-in-charge.
Material & labour sand cushioning using clean Fine River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed by Engineer-in-charge. ( Note:- Punned thickness shall be considered for payment purpose)
Supply and laying un-reinforced precast concrete cable cover, class HV type-I, flat size 300 mmX180 mmX 40 mm for cable protection, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed by Engineer-in-charge.
Supply, laying, jointing and testing of HT XLPE Cable of cross sectional area 95 Sqmm 3 core, 11000 Volt grade, "Earthed System" heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathing of PVC tape armourd with galvanized steel strip or wire and over all PVC sheathed conforming to IS-7098 (Part-2) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge.
Supply, laying, jointing and testing of HT XLPE Cable of cross sectional area 185 Sqmm 3 core, 11000 Volt grade, "Earthed System" heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathing of PVC tape armourd with galvanized steel strip or wire and over all PVC sheathed conforming to IS-7098 (Part-2) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge.
Making the hole under road and hard standing not less than 1 metre depth and suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as per existing surface complete all as specified and directed by Engineer-in-charge. Note: GI tubing light grade 100mm bore shall l be measured and paid under serial item no.13 here-in-after.
Supply and Fixing GI tubing, light grade, 100mm bore complete with all fittings for cable protection laid in trenches/fixed to poles/along wall/under road/across the drain complete all as specified and directed by Engineer-in-charge.
Supply and Fixing HT Feeder pillar box factory made cubical type dust and vermin proof, outdoor type, both side opening of size 110cm x 100cm x 60cm of MS sheet 3.15 mm thick powder coated, machine pressed front opening in two halves with rubber gasket/bedding, locking arrangement with sliding bolt including aluminium bus bar of size 50mm x 10 mm and 80 cm long 3 strips mounted on HT insulators. Each strip should be mounted minimum two insulator and nut bolt, panel shall be mounted on angle iron frame including heat shrinkable sleeve and legs made from angle iron of size 50mm x 50mm x 6 mm and legs 40 cm long duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer and including grouted in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete incoming/outgoing cable and including removal of old rusted unsv HT feeder pillar box complete all as specified and directed by Engineer-in-charge. .
Material & Labour for earthing complete with galvanized iron or steel earth plate electrode of size 60 cm x 60cm x 6.0mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below normal ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32 x 6 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer (including making of test point with GI strip of size 32 x 6 mm) including GI protection pipe 40 mm bore light grade for protection of strip upto the extent of 7.5 mtr all as directed, GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh, GI frame with suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C1 using 20 mm graded stone aggregates complete including excavation and earth work in any type of strata , all as specified and shown in electrical plate No 3 of SSR Part - I, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion and dismantling of old earthing. Note:- PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.complete all as specified and directed by Engineer-in-charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
Surindera Kumar Bansal
M/s Rohit Construction Co.
Vardhman Airport Solutions Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .