CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
REPAIR MAINTENANCE OF DISTRIBUTION TRANSFORMER VOLTAGE STABILIZER INCLUDING ALLIED WORKS AND MAINTENANCE OF 33KV AND 11 KV HT NETWORK AT BB CANTT SRINAGAR UNDER GE 864 EWS
2022_MES_550133_3
CWEK-33/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 864 EWS
Class C Category b ii
7 documents required · 7 mandatory
₹1,000
GE 864 EWS
₹1.1 L
HQ 133 WORKS ENGRS
9 Jan 2023
7 Dec 2022
5 Jan 2023
7 Dec 2022
28 Dec 2022
15 Dec 2022
7 Dec 2022 - 10 Dec 2022
10 Dec 2022
Amount
Disconnecting defective out door/indoor transformers of following various capacity upto 500KVA to 750 KVA from HT/LT side, taking out complete transformer oil, storing the same in suitable container (to be arranged by the contractor) opening the top cover and lifting the core assembly by means of tripod and chain pulley block carefully to check its condition, refilling the transformer oil after complete dehydration/filtration if required (to be paid separately) and necessary repairs re fixing complete core assembly and complete core assembly fixing the top cover and re-installation complete all as specified and directed.
All as per Item No 1.00 here-in-before above but distribution transformer of capacity 315 KVA to 400 KVA complete all as specified and directed.
All as per Item No 1.00 here-in-before above but distribution transformer of capacity 200 KVA to 250 KVA complete all as specified and directed.
All as per Item No 1.00 here-in-before above but distribution transformer of capacity 100 KVA TO 160 KVA complete all as specified and directed.
All as per Item No 1.00 here-in-before above but distribution transformer of capacity 63 KVA complete all as specified and directed.
Note Serial item No 1.00 to 5.00. (a) Pole mounted transformer lowering and taking down the same from pole structure to ground carefully if required shall be paid separately under relevant items. (b) In case of major repairs/replacement in transformer which can not be undertake at site the transformer shall be shifted to civil workshop and the cost shall be paid separately under relevant items (c) Cost of dehydration/filtration and other necessary repairs shall be measured and paid separately under relevant item (d) Contractor shall bring the mechanic at site for first inspection of the transformer after that transformer shall be shifted to civil workshop
Dismantling and taking down out door transformer from two pole /four pole structure lowering the same carefully by means of chain pulley block and all other required T&P and re-installation after repairs complete all as specified and directed.
Material and labour for rewinding of LT side winding with copper wire/strip matching with existing size/ gauge, fixing the coil in position in core assembly and making connection as per existing pattern including providing insulation, varnish etc complete all as specified and directed by Engr-in-charge.
Material and labour for rewinding of HT side coil with supper enamelled Copper wire/strip matching with existing size/ gauge, fixing the coil in position in core assembly and making connection as per existing pattern including providing insulation, varnish etc complete all as specified and directed by Engr-in-Charge.
Note - 1. The cost of coil shall be inclusive of varnish sleeve and insulating material etc no extra payment shall be made for the same . 2. Actual weight of wire (used for rewinding) will be measured and paid for each transformer mentioned above.
Replacement of cracked/worn out synthetic rubberized cork gasket 6mm thick for HT/LT bushes etc of various size all as specified and directed.
M &L for painting the outer surface of the transformer / Servo Voltage stabilizer with two coats of synthetic enamelled paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing MES/ SM No with enamelled paint complete all as specified and as directed for fransformer of rating 50 KVA to 630 KVA (Indoor/ outdoor type).
M&L for transformer oil for topping up or for replacement in Transformers / Servo voltage stabilizer complete all as specified and as directed. Note: Oil shall be in company sealed barrel having BDV not less than 40KV and Transformer oil topping up or replacement should be done on existing installation place on same days)
Material and labour cleaning sprarked/old transformer oil and all other foreign materials from external surface of transformer of capacity 50 KVA to 315 KVA and preparing the surface to paint the transformer body one coat of synthetic enamel while paint, including writing MES No & SM No withsmooth gray paint on back base complete all as directed by Engineer –in-Charge including replacement of outlived silica gel with new silica gel ‘A’ grade complete for transformer of capacity 50 KVA to 315 KVA. Note: Transformer oil filteration & dehyration by Ultra High Vaccum double stage machine should be done on existing installation place on same days and report of the same be obtained from the vendor).
Material and labour cleaning sprarked/old transformer oil and all other foreign materials from external surface of transformer of capacity 350 KVA to 750 KVA and preparing the surface to paint the transformer body one coat of synthetic enamel while paint, including writing MES No & SM No withsmooth gray paint on back base complete all as directed by Engineer –in-Charge including replacement of outlived silica gel with new silica gel ‘A’ grade complete for transformer of capacity 350 KVA to 750 KVA. Note: Transformer oil filteration & dehyration by Ultra High Vaccum double stage machine should be done on existing installation place on same days and report of the same be obtained from the vendor).
Supply and replacement of silica gel only with fresh blue coloured complete all as specified and as directed.
Supply and fixing in replacement Tap changer switch suitable for Transformer 63 KVA to 200 KVA complete all as specified and as directed.
All as per item No 15 here-in-before above but suitable for transformer capacity 250 KVA to 630 KVA complete all as specified and as directed.
Supply and replacing HT/LT side cable box cover plate made out of MS sheet of 16 SWG complete with nuts, bolts washers suitable for indoor / outdoor type transformer of capacity 63 KVA to 400 KVA complete all as specified and as directed.
M&L for replacement of HT 11 KV bush insulator suitable for distribution transformer of any type and of size upto 200 KVA complete, all as specified and as directed.
M&L for replacement of HT 11 KV bush insulator suitable for distribution transformer of any type and capacity 250 KVA to 630 KVA complete, all as specified and as directed.
M&L for replacement of LT bush insulator suitable for distribution transformer of any type and of size upto 200 KVA complete, all as specified and as directed.
M&L for replacement of LT bush insulator suitable for distribution transformer of any type and capacity 250 KVA to 630 KVA complete, all as specified and as directed.
M&L for replacement of HT bush rod made out of brass with nut bolt and washer suitable for distribution transformer of any type and of size upto 200 KVA complete, all as specified and as directed.
M&L for replacement of HT bush rod made out of brass with nut bolt and washer suitable for distribution transformer of any type and capacity 250 KVA to 630 KVA complete, all as specified and as directed.
M&L for replacement of LT bush rod made out of brass with nut bolt, rubber packing and washer suitable for distribution transformer of any type and of size upto 200 KVA complete, all as specified and as directed.
M&L for replacement of LT bush rod made out of brass with nut bolt, rubber packing and washer suitable for distribution transformer of any type and capacity 250 KVA to 630 KVA complete, all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-1 and specified including provision of earth wire protected by 25 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of up to 7.0m long galvanised earth lead wire 4mm and protection pipe of 25 mm bore medium graded ,GI light graded 20mm bore watering pipe
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and directed.
M&L for fixing GI funnel complete with wire mesh for earthing water pipe complete all as specified and directed.
M&L for pit cover of size 300X300X40mm thick of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape complete all as specified and as directed.
Disconnecting HT/LT cable/ busbar and earthing connetions of Servo voltage stabilizer of capacity 400 KVA, 3 phase from floor with the help of Crane to carry out overhaulling of servo voltage stabilizer comprising of the following:- (i) Draining out oil from chamber. (ii) Opening top cover, disconnecting winding connectio from bushing and taking out carefully core assembly complete with winding. (iii) Checking compactness of core & tighening the same where required. (iv) Chemical washing of winding to remove dirt, dust & carbon particles. (v) Cleaning of oil tank to remove oil sludge followed by painting of inner surface to tank with zinc chromate base paint. (vi) Refixing of core & winding assembly and making connection with HT/LT bushing. (vii) Replacement of worn out gaskets & nut/ bolts. (viii) Refilling of oil duly filtered/ dehydrated/ fresh oil( to be measured & paid separately under respective items). (Note: Overhauling of Servo voltage Stabilizer should be done on existing installation place on same day).
All as per Item No 30 here-in-before above but capacity 50 KVA to100 KVA complete all as specified and directed
All as per Item No 30 here-in-before above but capacity 5 KVA to 30 KVA complete all as specified and directed
Supply and install MC TRMS PCB suitable for voltage stablizer of capacity 30 KVA to 400 KVA complete all as specified and directed.
Supply and install Contactor 100 Amp, suitable for 50 to 100 KVA voltage stablizer 3 Phase complete all as specified and directed.
Supply and install 3Kg motor sync suitable for upto 100 KVA voltage stablizer complete all as specified and directed.
Supply and install RC suitable for 30 KVA to 400 KVA voltage stablizer complete all as specified and directed
Supply and install Carbon bush suitable for 30 KVA to 400 KVA voltage stablizer complete all as specified and directed
Supply and install closer sheet suitable for 30 KVA to 400 KVA voltage stablizer as per existing size complete all as specified and directed
Supply and install 20kg motor sync suitable for 400 KVA Voltage Stablizer complete all as specified and directed
Supply and install of Carbon roller assy suitable for 30 KVA to 400 KVA Voltage stablizer complete all as specified and directed
Supply and install of Tag & Tail assy as per sample suitable for 30 KVA to 400 KVA Voltage stablizer complete all as specified and directed
Supply and install of PCB Relay (1003) suitable for 30 KVA to 400 KVA Voltage stablizer complete all as specified and directed
Supply and install of flip flop suitable for 30 KVA to 400 KVA voltage stablizer as per existing sample complete all as specified and directed
Supply and install of Time delay relay suitable for 30 KVA to 400 KVA Voltage stablizer as per existing sample complete all as specified and directed
Supply and install of limit switch (B4C) suitable for 30 KVA to 400 KVA Voltage stablizer complete all as specified and directed
Supply and install of power contractor suitable for 30 to 400 KVA as per existing sample complete all as specified and directed
Supply and install of Aux contractor 4 Nos + 4NC 44W, 230V AC complete suitable for 30 to 400 KVA voltage stablizer complete all as specified and directed by Engr-in-charge.
Supply and install of Aux contractor 6 Nos +2NC 62W, 110V AC complete suitable for 30 to 400 KVA voltage stablizer complete all as specified and directed by Engr-in-Charge. Note: Contractor should be replace the accessories of voltage stabilizer item No 31 to 48 by the authorised service Engineer only.
Dismantling plain or corrugated steel sheeting any gauge,thickness including Nainital or similar pattern roof covering complete all as specified and directed.
S & F for 0.63mm Galvanised, Corrugated Mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zink coating 275 complete all as specified and directed.
Dismatling wrought iron or mild steel work of any description complete all as specified and directed.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., quality confirming to GDE Fe 410-W (Gde-E-250) quality A complete all as specified and as directed.
Demolition of cement concrete (Unreinforced ) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for 150mm thick cement concrete 1:2:4 type B-1,( using 20mm graded aggregate) as in sub base of flooring including Spike roling to surfaces or making impressions of expandel metal,whist the concrete is green complete all as specified and as directed.
M & L for preparation of new or previously untreated steel or iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide,zinc chrome primer complete all as specified and as directed.
Surface excavation in hard/dense soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
Supply and filling of 40 mm graded stone aggregate for loose filling complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr in wide and exc. 1.5 mtr but n exc 3.0 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I. Note :- 1. Dry fine sand of best available quality shall be used. 2. Punned thickness shall be measured and paid.
M&L for Sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M&L for Plain cement concrete, 1:2:4 type B-2 (using 40 mm graded stone aggregates) as in foundation, filling, mass concrete and copings and the like including necessary form work complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata and relaxing taken out cable complete all as specified and directed.
M&L PCC (1:2:4) type C-1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed.
Supply and fixing in replacement of unserviceable insulator post type insulator 254 mm height, 210 mm dia for 33000 volts grade. including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanised iron nut straps etc including taking down old one complete all as specified and directedby Engineer-in-Charge.
S & F in replacement of unserviceable Disc type, insulator three in series, porcelain, vitreous, 145mm height and 255mm dia ball and socket type, white brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts with GI nut, bdfs straps etcincluding taking down old one complete all as specified and as directed.
Supply and fixing Air break gang orerated switches vertical / horizontal mounted including 12 insulators and oprating mechanism for repair/replacement of broken /worn out components and insultors etc for current rating upto 200 Amps 11000 Volts. complete all as specified and as directed.
All per item No 70.00 here-in-before but current rating up to 200 amps for 33000 volts complete all as specified and as directed.
Supplying, laying or fixing, jointing and testing in repair / replacement of unserviceable HT under ground electric power cable, XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, (conforming to ISI-7098), ISI Marked, with aluminium conductor multi-stranded, heavy duty, 11000 Volts grade (earthed), laid in trenches/laid under floor, roads, paths or fixed on walls /on poles/in ducts etc 95 Sqmm 3 Core, complete all as specified and directed.
Supplying, laying or fixing, jointing and testing in repair / replacement of unserviceable HT under ground electric power cable, XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, (conforming to ISI-7098), ISI Marked, with aluminium conductor multi-stranded, heavy duty, 11000 Volts grade (earthed), laid in trenches/laid under floor, roads, paths or fixed on walls /on poles/in ducts etc 185 Sqmm 3 Core, complete all as specified and directed.
Supplying, fixing, jointing and testing and replacement of unserviceable Heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV, XLPE cable of size 50 Sqmm to 95 Sqmm 3 core , complete all as specified and directed.
Supplying, fixing, jointing and testing and replacement of unserviceable Heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 120 Sqmm to 185 sqmm , 3 core, complete all as specified and directed.
Supplying, fixing, cable jointing kit for 11 KV (Earthed) grade cable for in replacement of unserviceable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
Supplying, fixing, cable jointing kit for 11 KV (Earthed) grade cable for in replacement of unserviceable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
S&F in replacment of u/s tubing 'light grade' galvanised iron with all fittings including fixing on poles, walls etc. with flat iron clamps/ bolts / nuts/ washers or laid in floors/under roads 150 mm bore complete all as specified and directed.
S&F in replacment of unserviceable tubing 'light grade' galvanised iron with all fittings including fixing on poles, walls etc. with flat iron clamps/ bolts/ nuts/ washers or laid in floors / under roads 80 mm bore complete all as specified and directed.
S&F in replacment of unserviceable tubing 'light grade' galvanised iron with all fittings including fixing on poles, walls etc. with flat iron clamps / bolts/ nuts/ washers or laid in floors / under roads 50 mm bore complete all as specified and directed.
Dismantling of unserviceable ACB and S&F ACB 4 Pole, 415 volt, with microprocessor release, adjustable release mannual draw type of capacity up to 800 Amps, 25 KA including testing and commisioning complete all as specified and directed.
Dismantling of unserviceable ACB and S&F ACB 4 Pole, 415 volt, with microprocessor release, adjustable release mannual draw type of capacity up to 1000 Amps, 36 KA including testing and commisioning complete all as specified and directed.
Dismantling of unserviceable ACB and S&F ACB 4 Pole, 415 volt, with microprocessor release, adjustable release mannual draw type of capacity 1200Amps, 36 KA including testing and commisioning complete all as specified and directed.
S&F in repair/ replacement for power tansformer 6.3 MVA(OLTC), AC 3 phase, outdoor type for following items complete all as specified and directed. Make: Alstom/ABB HT VCB's
(a) Epoxy Arm - 01NO
(b) Transit resistance coil - 03Nos
(c) Main moving contact - 03Nos
(d) Arc/resistance contact - 03Nos
(e) Topping up of power Transformer oil having 40 KV dia electric strength.
M & L for replacement of damaged copper bus bars having length 5-6 mtr, 25 mm dia complete all as specified and as directed
S & F in replacement of heat shrink insulation tubes for all the bus bars and maintaining the RYB sequence in the system complete all as specified and as directed
M & L for Calibration and programming of all KV, PF, AMP and multifunction meters on different settings and as per the CTR Ratio complete all as specified and dirceted
M&L for testing complete with testing kit for HT VCB / Panel 33 KV indoor/ outdoor complete with calibration of all protective devices and over hauling of all mechanical parts of VCBs comprising (6 Nos out door type and 3Nos indoor type VCB and OLTC - 03 Nos for 33 KV ) all as directed.
Maintenance and complete overhauling of 11 KV, VCB including disassembling of operating mechanism parts, well cleaning with petrol and CRC-226 and replacing minor parts reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar,CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete all as specified and directed. Note :- spare parts will be measured and paid separately as under
S&F in repair/ replacement for HT VCB 11 KV, AC 3 phase, 50 HZ indoor type for following items complete all as specified and directed.
(a) Control wiring of HT VCB pannel with suitable size of copper wire complete with color code ferruls and tinned copper lugs.
(b) Trip coil 110 volt DC.
(c) Bakelite housing set.
(d) Spout set (set of three) shower and rose contacts.
(e) Auxiliary switch.
(f) Limit switch.
(g) Rotary switch.
(h) Auxiliary Contactor.
(j) Closing Coil 110 volts.
(k) Tripping lever.
(l) Charging lever.
(m) Charging gear for VCB.
(n) Indication lamp 110 volts (R, Y, B).
(o) Tripping pin.
(p) Push Button.
(q) Charging Motar complete 220 Volts.
(r) Charging Motar complete 220 Volts.
(s )Tublar bus bars copper 25 mm dia
(t )Heat shrink tubes RYB Colours
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7m long galvanised earth strip 25x4 mm and protection pipe of 40 mm bore medium graded ,GI light graded 20mm bore watering pipe
M & L for replacement of damaged earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation fer loop earthing etc.as required 25x4mm galvanised iron strip complete all as specified and as directed
M&L boring of holes under roads pavements hards standing by trenchless technology using ulta sound technique & necessary machine including HDPE pipe of 6 kg/sqmm of 150 mm dia suitable 0.4 Mpa working pressure all as specified & directed by Engineer-in-Charge.
S&F CT 33 KV outdoor type single Phase oil cooled CT of ration 33 KV DC class 150/5/5, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable CT complete all as specified and directed.
S&F PT 33 KV outdoor type single Phase oil cooled PT of ration 33 KV DC class 0.50-3, burden 50 VA, insulation level 70/170 KV voltage factor 1.2 Cont and 1.9 for 30 second confirming to IS 3156 including taking down old unserviceable PT complete all as specified and directed.
Trimming of tree branches touching with HT over head line in the entire cantonment so as to maintaining sufficient clearance and avoid fault on over head lines complete all as specified and directed.
M&L for preparation of old painted surface of 33 KV yard channel, angle iron by scrubbing, cleaning and painting with two coat of aluminium paint including writing SM No / MES No of all other items comkplele all as specified and directed.
Supply, installation, testing and commisioning of Lightining Arresters Linear type, distribution class with all fittings and fixing arrengements suitable to 33000 volts grade and discharge capacity upto 31 KV with and including making connections with suitable size of ACSR conductor including taking down old one complete all as specified and directed.
M&L for bulk head meter with CT/PT including multifactor ratio 1x1000 per unit suitable for three phase 33 KV Electric supply complete with As per BIS para metre to show date time current reading, load of PF,Voltage & KWH, alongwith accuracy 1.0 length with home display installed at KM Site complete all as specified and directed by Engr-In-Charge.
M/S Noor Mohammad Shalla
M/S Razdan Buildersand suppliers
ALCO ENGINEERSPVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .