| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹4.4 L+₹9,344 (2.19%)Rejected-AOC | L2 | Rejected-AOC other than lowest Bidder | |
| 3 | L3₹4.4 L+₹15,948 (3.74%)Rejected-AOC | L3 | Rejected-AOC other than lowest Bidder | |
| 4 | L4₹4.5 L+₹22,965 (5.38%)Rejected-AOC | L4 | Rejected-AOC other than lowest Bidder |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
28 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG
Noida
SERVICING MAINTENANCE OF SUMMER APPLIANCES AT DIFFERENT SECTORS UNDER AGE I COAST GUARD NOIDA
2022_MES_565263_1
AGE I CGN 32 22 23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Noida
E b i
7 documents required · 7 mandatory
₹500
AGE I CG
₹12,000
1 Feb 2023
1 Dec 2022
30 Dec 2022
1 Dec 2022
28 Dec 2022
15 Dec 2022
Amount
Disconnecting of electric connection of the split AC cap 2.00 TR from its stabilizer or its electric board and remove the front cover of indoor AC unit and clear it with pressure water and wire mesh/ brush/nylon brush without spoiling in side area of room, then refixing the front cover of indoor unit split type AC including cleaning of air filter. Remove the outer cover of out door unit and covered the condenser moto with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit with pressure water and applying cleaner solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit including greasing of fan motor, checking of complete wiring of ACs and tightening all electrical connection with thimble and reconnecting the electrical connection with DBs, Stabilizer as per site condition, Note - Spares required for replacement will be measured and paid separately (To be carried out in every six months interval)
Supply and fix in replacement new Running/ starting capacitors suitable for split AC cap 2.00 TR . Make :- Keltron/ Siemens/ Tibcon/ Sarda.
Supply and fix in replacement new Thermostatic switch suitable for split AC cap 2.00 TR . Make:- utrtol/Siemens /Carrier/ Tibcon/ Sarda.
Supply and fix in replacement new Fan Motor for out door unit suitable for split AC cap 2.00 TR Make:- Ranutrtol/ Siemens/Carrier/Tibcon/Sarda
Supply and fix in replacement new Electronic Display Board suitable for split AC cap 2.00 TR Make :As per OEM
Supply and fix in replacement new Swing Motor suitable for split AC cap 2.00 TR Make :As per OEM
Supply and fix in replacement new evaporator coil copper for split AC cap 2.0 TR Make :As per OEM
Supply and fix in replacement new condencer coil copper for split AC cap 2.0 TR Make :As per OEM
Supply and fix in replacement new copper pipe of size 1/4" for split AC cap 2.0 TR
Supply and fix in replacement new copper pipe of size 3/8" for split AC cap 2.0 TR
Supply and fix in replacement new insulation for pipe of size 1/4" or 3/8" for AC cap 2.0 TR
Material and labour for Leak test with CO2/Nitrogen gas and arrest leakage with brazing on indoor/oudoorof copper pipe .AC 2.0 TR
Material and labour for charging only refrigerant gas after pressure test to a compressor for split type AC 2.0 TR Capacity Meprom / Floron
Supply and fix in replacement new nylon air filter cleanable indigenous of suitable size for the split type AC 2.0 TR Capacity complete all as directed.
Supply and fix in replacement new fan blades suitable for condencer motor for the split type air conditioners 2 TR capacity all as directed. MAKE :As per OEM
Supply and fix in replacement new balance centrifugal blower with motor for the split air conditioners of the 2 TR capacity complete all as directed.Make :As per OEM
Supply and fix in replacement new cord less remote suitable for split AC of capacity 2.0 TR /1.5 TR as directed by Engineer-in-charge Make :As per OEM
Supply and fix in replacement new printed circuit board (PCB) of 2 TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed.Make :As per OEM
Supply and fix in replacement new printed circuit board (PCB) for inverter AC 1.5 TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed.Make :As per OEM
Supply and fix in replacement new printed circuit board (PCB) for inverter AC 2TR capacity and reconnecting the same with electrical connections for split type AC and complete all as directed.Make :As per OEM
Disconnecting the electrical connections and remove the split type A/C including copper pipe of capacity 1.5TR/2TR from the existing position and shifting the same to the near location, re-connecting the A/C after making the suitable hole with necessary connections including closing the hole at removed place with brick masonry matching with existing colour all as directed.
Taking down unsv indoor unit and supply and fix new indoor unit 2 Ton Cap with copper coil ie. (evaporator) including cutting brazing leak testing, gas charging reconnecting and testing complete all as specified and directed. Make : LG/Voltas/Blue Star/Carrier
Disconnecting of electric connection of the split type AC 1.5 TR from its stabilizer or its electric board and taking out from its position remove the front cover and outer cover, cleaning with pressure water and wire mesh/ brush/nylon brush and pressure water without spoiling in side area of room including cleaning of air filter, refixing the outer cover and front cover, greasing all moving parts.Checking and reconnecting electrical connection of DBs, Stabilizer,including checking of wiring of ACs as per site condition and tightening all electrical connection with thimble. Note - Spares required for replacement will be measured and paid separately (To be carried out in every six months interval)
Supply and fix in replacement new Running / Starting capacitors suitable for split type AC 1.5 ton . Make :- Keltron/ Siemens/ Tibcon/ Sarda.
Supply and fix in replacement new Swing Motor suitable for split type AC 1.5 ton Make :As per OEM
Supply and fix in replacement new copper evaporator coil for 1.5 ton split type AC.Make :As per OEM
Supply and fix in replacement new copper condencer coil for 1.5 ton split type AC.Make :As per OEM
Supply and fix in replacement new Electronic Display Board suitable for split type AC 1.5 ton.Make :As per OEM
Supply and fix in replacement new duel speed blower fan motor 1/5 H.P. by disconnecting all the electrical connections and reconnecting same with electrical connections and testing for the split type air conditioners complete all as directed.Make :As per OEM
Supply and fix in replacement new air filter cleanable indigenous of suitable size for the split type air conditioners of 1.5 ton capacity complete all as directed.
Material and labour for Leak test with CO2/Nitrogen gas and arrest leakage with brazing of copper pipe split AC 1.50 TR
Material for charging only refrigerant gas after pressure test to a compressor for split type 1.5TR Capacity Make - Meprom / Floron
Material and labour for carrying out repairs/maintenance/servicing of water cooler storage type of 40/80,60/120 Litres capacity, flushing of storage tank and chemical cleaning, repair/replaement of unserviceable/.worn out spares and accessores cleaning of drain pipes, float valves, s/s tray, push tap, body frames and base plates fan motor all as specified and directed by Engineer-in-Charge. Note - Spares required for replacement will be measured and paid separately Make: Voltas
Supply and fix in replacement new compressor suitable for 40/80,60/120 ltrs water cooler.LG/ Blue Ster/ Sumsung
Supply and fix in replacement new copper condenser coil suitable for 40/80,60/120 ltrs water cooler.Make :As per OEM
Supply and fix in replacement new running/starting capacitor suitable for 40/80,60/120 ltrs water cooler Make-Keltron/ Siemens/ Tibcon/ Sarda.
Supply and fix in replacement new CP push type Water tap 15 mm size suitable for water cooler storage type of 80/40,60/120 Litres
Supply and fix in replacement new relay suitable for 40/80,60/120 ltrs water cooler.Make :As per OEM
Supply and fix in replacement new door lock with key suitable for 40/80,60/120 ltrs water coolerMake :As per OEM
Material and labour for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for 40/80,60/120 ltrs water cooler
Material for charging only refrigerant gas after pressure test for 40/80 ltrs water cooler with existing type gas R-22,134a
Material and labour for carrying out repair /maintenance/ servicing of Refigarator of 165 Ltrs,180 ltrs 250 Ltrs and 310 Ltrs cap periodic cleaning, checking of electrical circuit and accessories to make the Refigarator in good working condition all as specified and directed by Engineer-in-Charge. Make:LG /Godrej Note - Gas charging if required will be measured and paid separately
Material and labour for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for Refigarator of 180-320 ltr cap
Material for charging only refrigerant gas after pressure test Refigarator of 180-320 ltr cap with existing type gas R-22,134a
Material and labour for carrying out repair /maintenance/ servicing of Deep freezer 320 ltr cap Freezer periodic cleaning, cleaning of water tub and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Deep Freezer in good working condition all as specified and directed by Engineer-in-Charge. Note - Spares required for replacement will be measured and paid separately Make: Voltas
Supply and fix in replacement new copper condenser coil for Deep freezer 320 ltr cap.Make :As per OEM
Supply and fix in replacement new condenser fan motor for Deep freezer 320 ltr cap.Make :As per OEM
Supply and fix in replacement new thermostate for Deep freezer 320 ltr cap.Make :As per OEM
Material and labour for Leak test with CO2/Nitrogen gas and arrest leakage with brazing for Deep freezer 320 ltr cap
Material for labour for charging only refrigerant gas after pressure test of Deep freezer 320 ltr cap with existing type gas R-22,134a
Supply and Fix in replacement of metal clad industrial plug of 20 Amp, 50 Hz, 2 pole and earth 250 volt. Make-Havells,L&T,Benlo
Supply and Fix in replacement of industrial 3 core PVC round seathed flexible copper cable of size 1.5 sq mm includind connected from plug connector of equipment complete all as specified. Make-Havells,Plaza,Finolex
Supply and Fix in replacement of industrial 3 core PVC round seathed flexible copper cable of size 2.5 sq mm includind connected from plug connector of equipment complete all as specified. Make-Havells,Plaza,Finolex
Supply and fix in replacement PVC flexible hose of 20 mm dia with all accessorfes fixed on wall/ceiling/roof etc with suitable GI saddles and screws for connecting with split type Air Conditioner as drain pipe complete all as specified and directed.
Supply and fix in replacement Rigid PVC pipe of 20 mm dia with all accessorfes fixed on wall/ceiling/roof etc with suitable GI saddles and screws for connecting with split type Air Conditioner as drain pipe complete all as specified and directed.Make-AKG,Plaza,Prince
Taking out dismentling, cleaning and servicing of evaporative desert cooler of capacity of 3000 / 4000 Cu. m. / Hr. and refixing the same on original position complete all as directed.
Supply and fix in replacement new fan motor working on 230 Volts 50 Hz 1/7 H.P. and reconnecting the same with electrical connections for the evaporative desert cooler of capacity of 3000 / 4000 Cu. m. / Hr. complete all as directed. MAKE: COOL HOME/KHAITAN /CG
Supply and fix in replacement new water pump working on 230 Volts 50 Hz 1/66 H.P. and reconnecting the same with electrical/water connections for the evaporative desert cooler of capacity 3000/4000 cu.m/hr. complete all as directed . MAKE: KHAITAN/CG/COOL HOME
Supply and fix in replacement new Evaporative Cellulose Cooling Pad for the evaporative desert cooler of capacity 3000/4000 cum/ Hr.
Supply and fix in replacement new grill to match with the replaced grill for the evaporative desert cooler of capacity 3000 / 4000 Cu.m/Hr. complete all as directed
Material and Labor for servicing and descaling of 200 LPD solar water heating system with descaling compound with the help of pressurized pumped rinsing with glycol chemical etc complete as required and all as directed by Engr in Charge.
Dismantling of existing unserviceable gasket washer nut bolt, washer clamps between all solar water heater panels / pipeline and SITC new Gasket washer I/C connections etc all as directed by Engr in Charge.
Material and Labor for replacement of old unserviceable Hose pipe including wire temp bearing capacity 120 degree centegrade complete all as directed.
Material and labour for fittings ( Male female CPVC brass ends joints / elbows & connections) for wornout & broken water CPVC pipes from solar plant to delivery line complete all as specified and directed.
SEHGAL ELECTRICAL INDIA
DP COMPLEX
AARYANS GLOBAL INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .