Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹27.4 L
EMD Value
₹55,000
Closing Date
20 Apr 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director IISER Pune
IISER Pune pashan 411008
Design Supply Installtion Testing Commissioning Validation of clean room for development of tissue culture facility at IISER Pune
2021_IISRP_630058_3
03/IISERPUNE/2021-22
Open Tender
Civil Works
Works
90 days
IISER Pune
Bidders to refer latest NIT and dates as per this call.
2 documents required · 2 mandatory
₹1,180
Director IISER Pune
₹55,000
9 May 2022
11 Apr 2022
21 Apr 2022
11 Apr 2022
20 Apr 2022
12 Apr 2022
90 days
Design , supply , installtion , testing and commissioning of Clean Room Tissue Culture facility at IISER Pune. Facility shall be designed from professional expert and shall got approved from IISER Pune , facility shall be designed for Clean Class BSL-4 . Ceiling-Wall shall be factory made knock down type seamless jointed panels , flooring shall be vinyl , double glazed window , consealed power-data wiring , one piece return air risers and necessary features associated with clean room. All airconditioning and electrical components shall be compatible for Clean room application. Stages to follow DESIGN - APPROVAL ON DESIGN BY IISER PUNE - SAMPING - EXECUTION - COMMISSIONING - VALIDATION - HANDOVER All works inside clean rooms/tissue culture involving clean room partitions, ceiling, and integration of services, automation, BMS works shall be got executed through one of the IISER approved shortlisted specialized agencies specified as below , For clean room works as detailed below. 1. GMP Technical Solutions , Tel:- 022-66083700/701 , Fax:- 022-6608373 Mobile- + 91 9805704573/+91 9405577471 Email- [email protected] , Contact person : Mr.Sandeep Kumar 2. Klenzaids Contamination Controls (P) Ltd Mobile- 09987023200 , Landline : + 91 22 61156215 , Fax : + 91 22 28377927 Email : [email protected] / [email protected] Website : www.klenzaids.com 3.Nicomac Clean Rooms FarEast LLP , Plot n° 116, Ida Bollaram, near Miyapur, Hyderabad – India 502325 , Ph. +91 95151 92020 Fax +91 08458 279790 , [email protected] Bidders to refer WHO Biosafety Manual ( Edition-3) for design of BSL Class III laboratory , manual is part of the tender document. VALIDATION : Agency shall provide facility validation from approved laboratory by measuring particulate count. Quoted rates shall be including cost towards design and validation. Nothing shall be paid seperatly. This specification applicable to all items below due to numbering constrains in the e-boq.
NON WALKABLE FALSE CEILING : Providing and fixing approved make pre-fabricated insulated sandwich panels - overall 44mm thick double skin non-walk able false ceiling made of 0.8mm thick GPSP G.I. sheets with 60-80 micron epoxy polyester powder coating of approved color with infill material made up of PUF with density 40 kg/m3 or rockwool with density 90 kg/m3 with appropriate bonding system, to comply with minimum 1 hour fire rating. False ceiling panels should be designed with tongue and groove joints and suspended by minimum M8 or M10 hot dip galvanized rods adjustable suspension with turn buckles anchored to RCC slab/beam. Rate to include cost of all materials, all additional 'U' channel frames for light fixtures/ HVAC grills, preparation of shop drawings as per site conditions and getting approval of the same before manufacturing, including the cost of minor components/materials required for execution of the item complete as per direction of Engineer in charge. Plan area of finished false ceiling shall be measured for payment. Approved Makes GMP / Klenzaids/Nicomac
CLEAN ROOM WALL PANELS - 44mm : Providing and fixing approved make 44mm/80mm/100mm thick double skin progressive type with intermediate non progressive panels comprising of 2 sheets of 0.8mm thick GPSP G.I. sheets with 60-80 micron epoxy polyster powder coating of approved color with infill material comprising of Polyurethane Foam (PUF) with density of 40kg/cum or rockwool with density 90 kg/cum inclusive of adhesive/glue with appropriate bonding system, to comply with minimum 1 hour fire rating. Partition frame work shall be with aluminium stand alone profiles at panel joints with 1mm thick G.I. Stiftner channel sections at every 300mm between panels with all gaps and joints sealed with Dow corning 786 Silicone sealant for leak proof joints. Rate to include cost of additional frames for all cut-outs etc. Rate to include cost of all materials, additional channels around cut outs/ opening around light fixtures/ HVAC grills as per site conditions, preparation of shop drawings as per site conditions and getting approval of the same before manufacturing panels, including the cost of minor components/materials required for execution of the item complete as per direction of Engineer in charge. One side of finished wall area shall be measured for payment. : 44 mm thick wall cladding panels. Approved Makes GMP / Klenzaids
CLEAN ROOM WALL PANELS - 80mm : Providing and fixing approved make 44mm/80mm/100mm thick double skin progressive type with intermediate non progressive panels comprising of 2 sheets of 0.8mm thick GPSP G.I. sheets with 60-80 micron epoxy polyster powder coating of approved color with infill material comprising of Polyurethane Foam (PUF) with density of 40kg/cum or rockwool with density 90 kg/cum inclusive of adhesive/glue with appropriate bonding system, to comply with minimum 1 hour fire rating. Partition frame work shall be with aluminium stand alone profiles at panel joints with 1mm thick G.I. Stiftner channel sections at every 300mm between panels with all gaps and joints sealed with Dow corning 786 Silicone sealant for leak proof joints. Rate to include cost of additional frames for all cut-outs etc. Rate to include cost of all materials, additional channels around cut outs/ opening around light fixtures/ HVAC grills as per site conditions, preparation of shop drawings as per site conditions and getting approval of the same before manufacturing panels, including the cost of minor components/materials required for execution of the item complete as per direction of Engineer in charge. One side finished wall area shall be measured for payment. : 44 mm thick wall cladding panels. : 80 mm thick wall panels. Approved Makes GMP / Klenzaids/Nicomac
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Wall to ceiling coving. Approved Makes GMP / Klenzaids/Nicomac
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Wall to floor. Approved Makes GMP / Klenzaids/Nicomac
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Wall to wall coving. Approved Makes GMP / Klenzaids/Nicomac
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Aluminium coving corner 3D (wall/wall/ceiling junction or floor junction)
Providing and fixing extruded Aluminium Powder Coated clip on type covings of 50/65mm radius with 1.2mm thick Aluminium sheet finished with epoxy powder coating of 60-80 micron thickness, colour to match panel, for wall to wall and wall to Ceiling junctions. : Aluminium coving corner 2D (wall to wall junction) Approved Makes GMP / Klenzaids/Nicomac
Hollow metal clean room steel door: Clean Room doors of size 1200 mm x 2100 mm Providing and fixing of Hollow metal clean room door from ISO 9001-2000 certified Manufacturer. The hollow metal doors should be made from high grade galvanized steel stretched level GPSP G.I sheet with double glazed vision panel. Single /Double leaf to required sizes and approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Approved Makes GMP / CG Airtech / MK Enterprise Door frame shall be single rebate profile of size 100 x 57 mm made out of 1.2 mm thick GPSP galvanized steel sheet (18 gauge ). Frames should be MITERED and field assembled with self tabs. Door frames should be prepared for suitable hardware as scheduled and should have necessary reinforcement to withstand regular wear and tear. All provision should be mortised, drilled and tapped for receiving the hardware. Rubber door silencers should be provided on the striking jamb. All door frames should be provided with SOFIT bracket and anchor fasteners for installation on clean room panels. Door shutter should be 44mm thick fully flush double skin door with vision panel. Door leaf shall be manufactured from 0.8mm (22 gauge) thick GPSP galvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb paper core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. Double glazed Vision panel shall be provided with 5mm thick toughened glass fixed with glazing tape flush with door shutter on either side. All doors and frames shall be finished with etched primer coating (35 microns), stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint (35 micron DFT) of approved colour. Steel surface should be blast cleaned to near to clean surface. Once the surface is cleaned the doors should be checked for finish before it is taken for painting.
Clean Room doors of size 1200 mm x 2100 mm - List of hardware to be provided per door i) 3 nos Hinges SS 304 Ball bearing Butt hinge 100 mm x 75 mm x 3mm - 4330 of Dorma make. ii) 1 pair Handle SS 'D' pull handle - TG D1250mm x 19mm with back to back fixing iii) 1 no S.S. push plate. iv) 1 no of TS 68 Standard arm Door Closer of Dorma. v) 1 no S.S kick plate 0.8mm thick 1100x300. vi) 1no Mortise dead lock 278 with both sides key operation cylinder-Dorma. vii) 1 no View glass 400mm x 800mm double glazed view glass with 5mm thick toughened glass fixed with adhesive tape and silicon sealant all around. viii) Door seal with pvc gasket all around and Drop seal for air tightness.
Supply & Fixing of double glazed view panel with 5mm thick toughened glass 26.00 Sqm fixed flush with both sides of panel with high performance double coated pressure sensitive acrylic foam structural glazing tape like 3M VHB or equivalent. Frame work with 2mm thick aluminium, epoxy powder coated to 60 80 micron thickness; frame width to match panel thickness including providing silica gel desiccant arrangement and silicone sealant all around to make it air tight. Approved Makes GMP / Klenzaids/Nicomac
HVAC RISER : Supply and installing of Return air riser made of G.I sheet complete with S.S 100.00 Each 304 grade perforated grille, G4 filter and volume control damper fitted in module. The return air riser shall be adequately supported. Size of riser 600mm length x 150mm depth x 3250mm height.
Providing and fixing cut-outs in ceiling/wall panels for HEPA filters/HVAC grilles, cables, light fixtures including providing SS grille for HVAC cut-outs with necessary aluminum powder coated frames with beading and neoprene gaskets and silicon sealant so as to make the cut-out air tight. i) WALL CUT-OUT(supply air grille 300/500x150mm)
Providing and fixing cut-outs in ceiling/wall panels for HEPA filters/HVAC grilles, cables, light fixtures including providing SS grille for HVAC cut-outs with necessary aluminum powder coated frames with beading and neoprene gaskets and silicon sealant so as to make the cut-out air tight. ii) CEILING CUT-OUT(Light fixture/ac diffuser 600x600mm)
Providing and fixing cut-outs in ceiling/wall panels for HEPA filters/HVAC grilles, cables, light fixtures including providing SS grille for HVAC cut-outs with necessary aluminum powder coated frames with beading and neoprene gaskets and silicon sealant so as to make the cut-out air tight. iii) 25 to 75mm dia holes for cables.
Providing and installing of Vinyl Sheet Flooring manufactured by Armstrong , Forbo, Tarkett Gerfloor in roll form , size 1.83 m wide, having a nominal total thickness of 2mm. All joints between vinyl sheets shall be bot seamed/welded using multi-coloured welding rod to match flooring colour after 24 hours of laying of rolls. Welding and seaming shall be done using automatic hot seam welding machine. Rate to include protection with 500 micron LDPE sheet with taped edges until completion of all other activities as the floor as per the instructions of Engineer in charge. Vinyl sheets should be laid over 2 to 3 mm thick self levelling base with cementitious self levelling compound, Ardite K15, Epocem or equivalent to get an even sub floor. Vinyl sheets shall be manufactured as per CE norms and EN 14041 :2004 05.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion (Fittings shall be paid for separately) .Powder coated aluminium (minimum thickness of powder coating 50 micron). Quoted rates shall be including GST , labour, lead , lift , trasportation etc complete. Nothing extra shall be paid seperatly. Approved Make JINDAL/BARUKA/Indian Aluminium Co. Quoted rates shall be including GST , labour, lead , lift , trasportation etc complete. Nothing extra shall be paid seperatly.
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Quoted rate shall be including at taxes , duties , royalties , lead, lift , trasportation , insurance , GST , etc. Nothing extra shall be paid seperatly. Approved Makes Nerolac/Dulux/Asian.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.Minimum 2 coats .Quoted rate shall be including at taxes , duties , royalties , lead, lift , trasportation , insurance , GST ,etc. Nothing extra shall be paid seperatly. Approved Makes Nerolac/Dulux/Asian.
Painting with synthetic enamel paint of satin finish approved brand and manufacture to give an even shade : Two or more coats on new work. Quoted rate shall be including at taxes , duties , royalties , lead, lift , trasportation , insurance , GST , etc. Nothing extra shall be paid seperatly. Shade and scheme shall be got approved from Engineer In-charge before taking-up work. Application methodology as specifified by Manufactorer. Approved Makes Nerolac/Dulux/Asian.
Removal and refixing of modular false ceiling of size 595X595 along with grid system and stacking grid and tiles polypacks in suitable boxes at location in IISER PUNE campus as directed by Engineer in charge. Rate shall be inclusive of scaffolding etc. complete . Nothing extra shall be paid separately.
Providing and fixing wall paneling by 8mm tapered edge calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with compressive strength 225 kg/ sq.cm, Bending strength 100 kg/sq.cm over frame work of aluminium /GI/MS etc all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish.Frame works shall be measured in respective items. Quoted rate shall be including removing of existing damaged ceiling , making proper supporting arrangement , scaffolding upto 5 meter etc complete. Actual area of board shall be measured for payment.
Sealing of holes by exterior grade silicon sealant of dow corning for structural glazing purpose with good adhesion between metal and frp/glass/acp. dow 895 / dow 995 with application nozzle-gun push mechanism. bottle of 300mm
Providing and fixing semi-transpernat glass film of approved make on glass surface as per approved shade and pattern.
Providing & fixing black colour weather proof silicone sealant 688 Grade DOW or equivalent make heavy duty silicon over backer rod of required size with adhesive removeable abro tape both side up to 8 mtr height with all safety , labour insurance, all complete as per approved drawing & direction of Engineer-in-Charge. Upto 5mm depth and 5 mm width.(Rate including of all taxes, wastage, GST, material, labour scaffolding, Cleaning site after work, etc complete including Providing & Fixing flexible Backer Rod 8mm dia weight 50gm / mtr in Grey colour in to the Gap of ACP External cladding height up to 8 mtr with all safety , labour insurance, proper filling in gaps with cutting, fixing etc. Complete. (Rate including of all taxes, wastage, GST, material, labour scaffolding, Cleaning site after work, etc complete. )
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per directions of Engineer-In-Charge.For door/ window/ clerestory window.Quoted rate shall be including GST , trasportation , lead , lift , scaffolding etc complete. Nothing extra shall be paid seperatly.
Disposal of constrution debries , waste and clearing site and dumping debries within campus by manual or mechanical lead /lift and leveling.
Supply Installation testing and commissioning of ductable Air conditioning unit of capacity 4.0 TR with a minimum airflow of 1000 CFM. The unit should be complete with indoor and outdoor units. outdoor unit mounted with suitable metal stand with R410 or equivalent green refrigerant gas only. The quoted rates shall be inclusive of all taxes and levis, duties, lead, lift,transpotation, placing, scaffolding, core cutting of required diameter in walls, finishing and minor civil works and nothing shall be paid separately. The outdoor unit consists of condensing unit, microprocessor control panel, scroll compressor, condensing fan, liquid reciever & Etc.And theindoor unit consists of blower fan, evaporator coil and a controller connected with corded remote controller for controlling the temperature. The rate shall be inclusive of cost of all the materials, labour for installation, import duty/excise,all taxes & levies, octroi etc. and nothing extra shall be payable. (Make : Toshiba / Carrier/ Mitsubishi / Daikin)
Supply installation testing and commissioning of hard refrigerant copper piping of suitable size for 4tr ductable Ac's with 18 mm thick nitrile insulation (Both Suction & Discharge ) and fittings like elbows, couplers,tee,joints,brass fittings,U loops, expansion loops Etc with supports at every 5 feet of interval. (Make : Totaline/Mandev/Mehta)
4C x 4 Sq.mm. ( XLPE Copper Armoured Cables ) Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations.(Make : - Polycab/Havells/Finolex)
6C X 1.5 sqmm copper armoured stranded control cable Supply, laying and commissioning of following size 1.1KVgrade XLPE PVC insulated armoured copper conductor cable, on cable tray with all installation materials including necessary double compression glands and terminations. (Make : - Polycab/Havells/Finolex)
UPVC drain pipes:- 25 mm dia. Supply, Installing, testing and commissioning of UPVC pipe for condensate complete with 6mm thick nitrile rubber insulation drain for AHUs/ FCU, cut to required length with necessary, clamps, supports, hangers, fittings such as bends, tees, reducers etc to nearest drain point complete as per technical specifications with all the necessary mounting accessories as required for complete installation.
Supply and fixing of 25 Amps Three Pole MCB along with enclose box of steel type. (Make :- legrand/Schnider/ABB/L & T)
SHEET METAL WORKS :- 0-750 -------0.63 MM (24G) with flanges Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (Jindal / TATA / SAIL)
Duct thermal insulation :- 16 mm thick Supply, Installing, testing and commissioning of duct thermal insulation, elastomeric nitrile rubber with aluminium foil faced, class 'O' on ducts complete as per technical specifications with all the necessary mounting accessories as required for complete installation. The thermal conductivity of insulation shall not be more than 0.035 W/m°k @ 0°C mean temperature and density of insulation shall be 40-60 Kg/Cum. ( Make :Armacell / K flex / Thermobreak)
Duct Accoustic Insulation:- 9 mm thick Supplying, installing & testing of acoustic lining Class '1' open cell nitrile rubber within supply and return air ducts as per the specifications. All ducts shown cross hatched on the approved shop drawings shall be provided with acoustic lining of open cell nitrile rubber insulation with density 140-180 Kg/ cum as per technical specifications with all the necessary mounting accessories as required for complete installation. The thermal conductivity of insulation shall not be more than 0.045 W/m°k @ 0°C mean temperature. THe material shall have anti microbial property ( Make :Armacell / K flex / Thermobreak/Twiga)
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. (Make : George Rao / Airmaster / Cosmos / Systemsaire)
Providing and fixing of filter plenum for 300-600 CFM with terminal HEPA filters with 99.97 % efficiency down to 0.3 microns for clean room area with extra fan inbuilt with HEPA with 3 speed controller for creating the static pressure with necessary mounting frame work, perforated aluminium sheet complete as per specifications and as required. The material of construction is aluminium. the size of the HEPA is 600 * 600 mm. (Make :- Dyna/Airtech/American Air Filter/Equivalent)
Supply, installation, testing , commissioning of Gas Distribution System for Laboratory Gases in SS 304 seamless tube. All Joints shall be compression fittted ferrule type fittings of approved makes. System shall be tested and handed over at 10 bar pressure test till Manfold. All components up to manifold system of Gas Bank System shall be tested at minimum 150 bar and Leak free , full functional GDS system shall be handed over to IISER PUNE . Quoted rate shall be including all necessary fittings, tools , tackles , bending tool , welding machine , GST , lead , lift etc and all necessary equipment’s required at site. Agency shall submit PN & ID and obtain approval of Engineer In-Charge before taking-up GDS works. Wall marking shall be done showing GDS route actal at site and approval on profile making shall be obtained before fixing of tubes. System shall be guaranteed for 1 year for leakage and fittings , comprehensive guarantee of complete system shall be submitted on Rupees Five hundred bond paper with free replacement of defective components to IISER PUNE. Actual components listed below installed at site shall be measured for payments. Nothing extra shall be paid seperatly. Approved Makes M/s Excel / M/s Sai Engineers / M/s ABP Process. This specification applicable to Item No 41 to 52
Manifold Block with mounting bracket : Fabricated Type for SS 304 1/4" System.
1/4 " cylinder Isolation Valve
Cylinder mounted Two Stage Regulator (Inlet pressure 250 bar and outlet pressure 0 to 16 bar)
1/4 " OD Flexible Hose with bullnose connector & safety wire rope (1 meter long)
Cylinder bracket with Chain
Ball valve 1/4" OD
Check valve 1/4 " NPTF x 1/4" NPTM
SS 304 , Seamless Tube 1/4" OD
Point of use regulator ( 10 bar inlet 7 bar Outlet) with Analog Dial Guage. 1/4" OD with Nozzels of 1" length.
Union 1/4" diameter
PP clamp set 1/4" OD
Alluminium profile
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
EARTHING SYSTEM :Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB where 3 phase outlets are required.) 4 way (4 + 12), Double door
MCCB,MCB&DB'S Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
MCCB,MCB&DB'S Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. FOUR pole
MCCB,MCB&DB'S Supplying and fixing 16 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Tripal pole
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.. as Group C
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 4 Module (For Power socket/ ELV Purpose)
Supply & fixing following modular switch/ Socket on the exisiting modular plate & switch box including connection but excluding modular plate etc. as required : 15/16 amp switch (For Power socket)
Supply & fixing following modular switch/ Socket on the exisiting modular plate & switch box including connection but excluding modular plate etc. as required : 6 pin 15/16 amp socket outlet (For Power socket)
Supply and fixing modular blanking plate on the exisitng modular plate & switch box with matching colour including connection but excluding modular plate etc as required.
Supply & installation of surface mounted DLP U- PVC adaptable trunking raceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with removable covers, complete with necessary bends, suitable sized junction boxes, internal angle, external angle, flat 90 degree angle , end caps and tees etc, Complete. (For every 1mtr distance cable tag has to be provided for each circuit in the raceways - as more that 1C FRLS copper wire is required for 1 Circuit) PVC RACEWAYS ( Along the wall), DLP U- PVC adaptable trunking . Size: 105x 50mm PVC Raceways for Power & Data with above specifications
Supplying and fixing following Modular base & cover plate ( Clip on support for mounting switches etc) on existing DLP U PVC trunking etc. as required. 2 module
Supplying and fixing following Modular base & cover plate ( Clip on support for mounting switches etc) on existing DLP U PVC trunking etc. as required. 4 module
Supply and fixing of seperation partition 85 mm in existing DLP U PVC trunking as required.
Clean room light : Supply, Testing, commissioning and installation of Recessed Mounted 2'X2' LED Luminaire which is useful for cleanroom facility having class 100000 cleanroom. Installation should be done on existing metallic or other false ceiling with required accessories as complete. Specifications : IP66, dust free, LED, clean room bottom opering luminaire, Operating temperature 0 to 45 degree celcius, Operating voltage 140 to 270 V, Avg life 50000 hours, high performance electronic driver, CRCA powder coated white after phosphochomate treatment, Screwlees bottom frame, Electronic driver with SMPS based constant current supply , output short circuit, protection, surge protection and other safety test as per IS:15885 part2/sec13, mounting provision for recess mounteding through 4 nos recessed mounting clamps, Diffuser - high quality polycarbonate opal diffuser for glare free uniform light distribution, Light source - efficincy of greater than 120 lm/w and viewing angle of 120 degree to ensure better uniformily. Wattage of fixture 32 to 40 W, System lumens 3200 to 4000 L with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire. Luminaire should give more volumetric light & higher vertical illumination.Luminaire should be available in different Lumen Packs of 3000 lm with different CCT. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters EQUI. TO Havells TOCR2X2R34WLED857SPCMS / PHILIPS / WIPRO / Syska
MV Cable Laying: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct / on surface as required. Upto 35 sq. mm
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required 4 x 4Sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type ) 4X4 sq.mm Copper ,XLPE Armourd Cable
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug topalongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
End termination of Cu cable : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site,and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/ PVC COPPER conductor cable of 1.1KV grade of following sizes as required 4 x 6Sq.mm Copper ,XLPE Armourd Cable
M.V. Cu Cable supply : Supply, loading ,transportation unloading at site, storages at site ,shifting from storage place to site, of 1100 Volts grade XLPE insulated over all FRLS outersheathed, Copper conductor, armoured LT power cables of as per IS :1554 (Part 1) of following sizes. .( Note :- Cable shall be considered flat armoured type ) 4X6 sq.mm Copper ,XLPE Armourd Cable
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At field side ) as required.
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At rack side ) as required.
Supply & installation of 24 port Jack fully loaded Patch Panel, make D link with required accessories as complete.
GMP Techncial Solutions Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .