Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC NH 148 B NEAR BABA GHISARAM FILLING STATION VILLAGE PALI MAHENDERGARH 123029 | MAHENDERGARH | MAHENDERGARH | HARYANA | 123029 | ₹1.3 Cr | L1 | Accepted-AOC L1 |
Tender Value
₹98.5 L
EMD Value
₹2.0 L
Closing Date
16 Sept 2021, 5:00 pmClosed
R.Nagender Singh
XEN (E)
Up-gradation of 100 to 200 bedded Hospital in Narnaul (Pdg. EI only)
2021_HRY_186392_1
PWD/HRY/RWR/sept04
Open Tender
Electrical Works
Works
540 days
XEN (E)
Refer DNIT
2 documents required · 2 mandatory
₹5,000
₹2.0 L
4 Jan 2022
6 Sept 2021
17 Sept 2021
6 Sept 2021
16 Sept 2021
6 Sept 2021
Amount
Supply and erection of PVC copper insulated and sheathed 2-core circular flexible wire.Size 1.50 sqmm ( 48 / 0.20mm).
Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections .Triple pole switch with neutral link 63 amp. 415 Volts
Four pole change over switch 63 amp. 415 Volts
Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections.15 amp.to 60 amp. 415 V ,10 KA 3-phase
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide.Size 40 mm x 40 mm x 6 mm.
M.S.Sheet ..Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. S.P.N. enclosure for single pole MCB 20 amp
T.P.N. enclosure for triple pole MCB 20 amp.
Blanking sheet .Supply and erection of blanking sheet in existing distribution board.
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections.Miniature circuit breakers of 9 KA breaking capacity.SP MCB of 9 KA breaking capacity 6 amp. to 32 amp
TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp.
Supply and erection of Fittings and Accessories.Bakelite angle / straight button holder large size.
Supply and erection of rectangular bulk head fitting of size 17 cm x 14 cm, aluminium casted with aluminium colour out side and white stove enamelled inside/complete with guard, glass etc. secured by brass screws suitable upto 100 watts lamp with B.C. lamp holder but without lamp.
Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
Supply and erection of ceiling fitting complete in all respect including cost of brass lamp holder , globe etc. without the cost of lamp. 250 mm dia meter .
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. .
Supply and erection of lumineous bell indicator complete including making necessary connections and fixing the same on wall etc. to complete the job in all respect.
Erection and carriage of fans.Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.
Erection of cabin fan complete with necessary earthing including carriage from local railway station /goods transport /PWD store to the site of work.
Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 32 mm dia 1.60 mm thickness flushed.
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 120 mm dia.
Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
Extra for using salt and charcoal / coke for pipe earth electrode as required.
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as equired.
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired.
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material.
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. stapples of same size.
Supply and erection of 20 mm x 3 mm thick copper tape fixed with suitable copper staples of same size.
(R) Lightning conductor (a) Copper. Supply and erection of copper tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with suitable copper stapples of same size.
(b) Lightning conductor Galvanised iron.Supply and erection of G.I. tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with G.I. stapples of same size.
Supply and erection of 25 mm dia meter 1.5 metre long lightning G.I. tube rod tapered in to a point at the top with 16 cm. X 16 cm x 3 mm thick G.I. base plate and necessary nuts and bolts with washer.
Prioviding and fixing, testing joint made of 20mm x 3mm thick G.I. strips 125mm long with 4 Nos. G.I. bolts and nuits, check nuts with washer complete.
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refiling of trenches. 300 Sq. mm 3.5 Core Cable .
25 Sq. mm 4 Core Cable .
35 Sq. mm 4 Core Cable .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 70 Sq. mm 3.5 Core Cable .
95 Sq. mm 3.5 Core Cable .
300 Sq. mm 3.5 Core Cable .
16 Sq. mm 4 Core Cable .
25 Sq. mm 4 Core Cable .
35 Sq. mm 4 Core Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core .
300 Sq mm to 400 Sqmm Cable 3 to 3.5 Core .
Miscellaneous .Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia.
Supply and erection of caution notice plate in three languages.
Supply and erection of shock restoration chart in glass frame
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work.16 sqmm .
Wiring in 1.5 sq.mm PVC Insulated Copper conductor cable in 1.6 mm thick conduit pipe. Fan Point.Short point
Medium Point
Long point.
Light Point.Short point
Medium Point
Long point.
Light point without control.Medium Point
Long point.
Call bell point including M.S box of size 180 mmX100 mmX 60 mm deep for Call bell.Medium Point
Long point.
3 pin 5 amp. plug point including earthing the 3rd. pin etc.Short point
Medium Point
Long point.
3 pin15 amp. plug point with 4 sq mm PVC insulated Copper conductor cable- including earthing the 3rd. pin etc.Short point
Medium Point
Long point.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe .Size 1.5 sqmm ( 3/0.81 )
Size 4 sqmm ( 7/0.85 )
Size 6 sqmm ( 7/1.05 )
Size 10 sqmm ( 7/1.35 )
Supply and erection of Double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4-way , SP&N ( Horizontal)
8-way , TP&N ( Horizontal) (8+24)
Supply and erection of Double pole / four pole Residual Current Circuit Breaker ( RCCB/ELCB) suitable for operation on 240/ 415 V 5Hz. Ac supply duly ISI marked installed in existing sheet steel enclosure including making necessary connections with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work. 16/240V DP ELCB 100 MA sensitivity.
32/240V DP ELCB 100 MA sensitivity.
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 20 mm dia.
25 mm dia.
Supply and erection of copper lugs including crimping etc. upto the entire satisfaction of Engineer-in-Charge of work.Size 1.5 sqmm to 2.5 sqmm
Size 4 sqmm to 6 sqmm
Supply and erection of MS Saddle and clamps duly galvanised , on wall / RCC parapit for fixing underground cable at a distance of 0.60 metre center to center fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work.
Supply and erection of MS box made of 16G MS Sheet recessed in wall, with arrangement of fixing brass screws including cost of 2 Nos. checknuts of required size and one no. PVC bush for each pipe including all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of work. With 2 coats of primer
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect.10 amp. 1 way switch
20 amp. switch
10 amp. Socket
16 amp. Socket
Bell Push
Fan Regulator
Call bell Ding-Dong (Monica)
Blanking plate.
Providing and fixing GI concealed sheet metal boxes with inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respect.1 & 2 Modules
3 Modules
4 Modules
6 Modules
8 Modules
12 Modules
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of work. PVC pipe of 32mm dia
Supply & fixing of rotary handle for on / off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material required to complete the job in all respect.up to 125A MCCB
Above 125A MCCB
S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work.HDPE pipe 63 / 50mm outer dia / inner dia.
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 100 amp
4 pole MCCB 200 amp
4 pole MCCB 300 amp to 400 amp
4 pole MCCB 500 amp
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. 100 amp 4 pole ON load changeover switch
Load Bank 8 way 250 Amp.
Supply & erection of cable tray made out of 2 mm thick galavanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work.40 x 100 mm
Supply & erection of factory manufactureed cable tray cover made of 16g GI Sheet complete with Fastoner Nuts bots and in position including all petty material required to complete the Job in all respect upto the Entire statisfaction of Engineer in Charge of the work. Suitable for 40 x 100 mm
Suitable for 50 x 150 mm
Suitable for 50 x 300 mm
Supply & Erection of bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand with one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work. Stand made out of GI pipe 32mm dia.
Supply & Erection of rubber mat of size 1Mx2 M X 12mm thick suitable for 11 KV ISI marked complete in all respect upto the entire satisfaction of the engineer In-charge of the work.
Supply & erection of fire extinguisher ISI marked Co 2 type 4.5 Kg. Capacity as Per ISI 7285 duly erected on wall with hook including the cost of hook, screw etc. with all the labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer In charge of the work. Make: Ajay, Zenith, Minimax.
Supply & Erection of fire buckets of 9 ltr. capacity made out of 24guage G.l sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire' as per fire protection necessar sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire \satisfaction of the Engineer m charge of the work
Supply , fixing , connecting and testing of OEM Manufactured APFC Panel 300 KVAR @ 440V with 7% detuned reactor. The stage ratings shall be 2 X 12.5 KVAR + 1X 25 kVAr + 5 X 50 KVAR, The APFC Panel shall be fully type tested and shall comply to IEC 61439-1 and IEC 61921. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. Approved Makes- ABB, Schneider,Legrand.As equipment shall be comprising of the following:-Insulated bus bar assembly made from Aluminium and rated of 800 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV.The incomer of the APFC Panel shall be a 500 Amp, MCCB, 3P, 50kA TMD type with O/L & S/C protection, Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. . Make:- Schneider Electric / ABB / Legrand.Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 440V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992. Make – Schneider Electric / ABB / Legrand.hort-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 36kA . The MCCB shall be of certified design confirming to IS Make:- Schneider Electric / ABB / Legrand.PF Regulator : Advanced Range PF Regulator shall have 8 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IS. Make : Schneider Electric / ABB / Legrand.Stage Contactor & reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. Supply to capacitor should be through 7% Aluminium wound detuned reactorThe rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IS.Make – Schneider Electric / ABB / Legrand.Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer.
Recovery Items .Supply and erection of Fittings and Accessories.Switch 5 amp. On existing sheet.
Wall socket 5 amp. On existing sheet.
15 amp. Switch on existing sheet .
3 pin 15 amp. Multi socket on existing sheet.
Bakelite sheet including fixing with brass screws and washers.5 mm thick .
Supply and erection of MS box made of 16G MS Sheet recessed in wall, with arrangement of fixing brass screws including cost of 2 Nos. checknuts of required size and one no. PVC bush for each pipe including all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of work. With 2 coats of primer
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .