Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹54.0 L+₹3.6 L (7.17%)Rejected-AOC NO 36 MARAGATHAM STREET SAKTHI NAGAR NAGALANMAN NAGAR JOTHI NAGAR POST ARAKKONAM VELLORE TAMIL NADU 631003 | ARAKKONAM | VELLORE | TAMIL NADU | 631003 | L2 | Rejected-AOC Rejected | |
| 3 | L2₹54.2 L+₹3.8 L (7.53%)Rejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Rejected | |
| 4 | L4₹55.8 L+₹5.4 L (10.8%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹56.5 L+₹6.1 L (12.1%)Rejected-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
2 Dec 2020, 6:00 pmClosed
GE M Arakkonam
GE M Arakkonam
REPAIRS / OVERHAULING / SERVICING WORKS TO LT VOLTAGE STABILIZERS OF VARIOUS CAPACITY INCLUDING REPLACEMENT OF UNSERVICEABLE COMPONENTS / ACCESSORIES OF APFC PANELS, LT PANEL / FEEDER PILLAR BOXES AND CONNECTED WORKS AT VARIOUS SUB STATIONS AND MAIN
2020_MES_396176_1
8930E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE M Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (M) Arakkonam
₹98,000
28 Dec 2020
18 Nov 2020
4 Dec 2020
18 Nov 2020
2 Dec 2020
28 Nov 2020
19 Nov 2020 - 23 Nov 2020
Amount
Material and labour for disconnecting all cable connections of unserviceable LT servo voltage stabilizer, 3phase, 50Hz, 415V, oil cooled of capacity upto 75 KVA any make and shifting to workshop including checking for defect and maintenance / servicing / overhauling to complete stabilizer comprising of servo motor, Electric control panel, wiring including replacing defective minor parts, burnt wiring etc as required and cleaning, greasing of all the moving parts, checking and reinstall and making all connection, testing for its smooth functioning on completion complete all as specified and directed.
All as per item no-1 here-in-before but for stabilizer of capacity 100KVA to 160 KVA of any make. Note for Item 1&2 :- (i) The Major spares like Transformer oil / wiring kit / motor/Gear/ contactor etc shall be measured and paid separately under relevant schedule of item as supply only. Fixing labour cost is included in the rate quoted for item-1&2. (ii) Quoted rate deemed to include labour cost for maintenance including maintenance of record as directed. (iii) The quoted rate includes S&F necessary minor spare parts / accessories like control wire set, fuse, limit switch, lugs as required for replacement of unserviceable spares/accessories of any type. (iv) The quoted rate includes consumables like grease and hardware like bolts and nuts etc including necessary machining work of any type. (v) This item shall be measured and paid as carriedout, but once the stabilizer made serviceable and afterward If any defect arrise in the repaired stabilizer the contractor should repair/rectify the same without claiming any additional cost on this account till completion of defects liability period of 2 years. (vi) Repair/ servicing work to be carried out only by service person of OEM or his authorised agency.
Supply only following spare parts / accessories suitable for servo voltage stabilizer of any make. Note for item no- 3: (i) The following spareparts/accessories to be used as replacement during repair work vide item No-1 and 2 here-in-before. (ii) The Labour cost for fixing spareparts/accessories to be included in the rate quoted for item no- 1 & 2 here-in-before.
Gear upto 55 teeth as per existing specification all as directed.
Gear 56 to 75 teeth as per existing specification all as directed.
Gear 76 to 100 teeth as per existing specification all as directed.
Variac 10 Amp capacity all as directed.
Variac 15 Amp capacity all as directed.
Variac 23 Amp capacity all as directed.
Variac 35 Amp capacity all as directed.
Variac 60 Amp capacity all as directed.
Variac 100 Amp capacity all as directed.
Variac 125 Amp capacity all as directed.
COS switch 32 Amp all as directed.
COS switch 63 Amp all as directed.
COS switch 125 Amp all as directed.
COS switch 200 Amp all as directed.
COS switch 250 Amp all as directed.
3 Phase BBT for 20 KVA stabilizer all as directed.
3 Phase BBT for 32 KVA stabilizer all as directed.
3 Phase BBT for 50 KVA stabilizer all as directed.
3 Phase BBT for 75 KVA stabilizer all as directed.
3 Phase BBT for 100 KVA stabilizer all as directed.
3 Phase BBT for 160 KVA stabilizer all as directed.
Contactor three phase 32 Amp all as directed. Make - Schneider/ABB/Legrand/Siemens
Contactor three phase 45 Amp all as directed. Make - Schneider/ABB/Legrand/Siemens
Contactor three phase 95 Amp all as directed. Make - Schneider/ABB/Legrand/Siemens
Contactor three phase 185 Amp all as directed. Make - Schneider/ABB/Legrand/Siemens
Motor 3KG suitable for servo volt stabilizer all as directed.
Motor 7KG suitable for servo volt stabilizer all as directed.
3KG RC Network suitable for servo volt stabilizer all as directed.
7KG RC Network suitable for servo volt stabilizer all as directed.
Control board suitable for servo volt stabilizer all as directed.
Power transformer 230V/0-15 all as directed.
LED display board suitable for servo voltage stabilizer.
Supply only New Transformer Oil as per IS-335 Std requirement. MAKE : POWER OIL/HP/Indian oil/BP
Material and labour for one coat of synthetic enamel spray painting of approved colour to Servo stabilizers over entire external surfaces including preparation of surfaces , free from dent etc including necessary writing of lettering and marking No etc complete all as specified and as directed.
Material and labour for Checking,Cleaning,servicing and overhauling of existing APFC Panels of any rating complete with PFC Controller, MCCB, MCB's, Contactors, relays and Busbar / cable connections of any rating / size with CRC spray including tightening of connections of power cables / control cable, bus bar, PFC Controller,capacitors and allied item connections including replacement of burnt Copper / Aluminium lugs all as per site requirements complete all as specified and directed. Note for Item 5 :- (i) The Major spares like MCCB/MCB/capacitor etc shall be measured and paid separately under relevant schedule of item. (ii) Quoted rate deemed to include labour cost for servicing/ maintenance. (iii) The quoted rate includes S&F necessary minor spare part/accessories like control wire, fuse, lugs as required for replacement of unserviceable items. (iv) The quoted rate includes consumables like CRC spray and hardware like screws, bolts and nuts etc.
Supply and fix MCB SP 240 volts 6-32 amps C curve with 10KA breaking capacity. Make: Legrand / Siemens / Schneider / ABB
Supply and fix MCB TP 415 volts 6-32 amps C curve with 10KA breaking capacity. Make: Legrand / Simens / Schneider / ABB
Supply and fix MCB TP 415 volts 40-63 amps C curve with 10KA breaking capacity. Make: Legrand / Simens / Schneider / ABB
Supply and fixing MCCB Adjustable Thermal & Fixed Magnetic setting 415V, 3 Pole of rating 200 Amps, ICS=100%ICU, Breaking capacity 36 KA including additions / altertions to existing MCCB mounting place in the panel for properly fixing and reconnecting In / Out going bus bar or cable connections including s&f extended teriminals as per site requirements and making good distrubed panel surfaces all as specified and directed. Make - Schneider / ABB / Legrand / Siemens
All as per item no-9 here-in-before but for MCCB of rating 100 Amps, ICS=100%ICU,3 pole, Breaking capacity 16 KA all as specified and directed.
All as per item no-9 here-in-before but for MCCB of rating 160 Amps, ICS=100%ICU,3 pole, Breaking capacity 16 KA all as specified and directed.
All as per item no-9 here-in-before but for MCCB of rating 63 Amps, ICS=100%ICU,3 pole, Breaking capacity 16 KA all as specified and directed.
Taking down existing defective panel board indication lamp (R/Y/B/G colour) from the panel and replacing with new LED indicator lamp complete all as specified and as directed by Engr-in-charge.
Taking down existing defective VAF meter from the panel board and replace with new 3 phase VAF meter,class1, with LED display,for showing voltage, Amps, frequency including necessary wiring and wiring materials complete all as specified and as directed by Engr-in-charge. Make: AE / Siemens / Schneider / L&T / C&S
Taking down existing defective APFC control relay from the panel and replace with new 6 stage APFC relay with CT input and including S&F CT of appropriate rating including necessary wiring and wiring materials complete all as specified and as directed. Make: AE/Siemens/Schneider/L&T/C&S
All as per item no-15 here-in-before but for 8 stage APFC relay with CT input and including S&F CT of appropriate rating all as specified and directed.
All as per item no-15 here-in-before but for 12 stage APFC relay with CT input and including S & F CT of appropriate rating all as specified and directed.
Material and labour for writing in coming and out going details in panel as per site requirement, with letter height not less than 15mm, boldly and solidly with thin self adhesive sticker of approved tint complete all as specified and as directed. Note: writing for each incomming / out going feeder / breaker in the panel shall be measured as one job.
Taking down existing defective CT coil from the panel and replace with new CT rating 100 / 5A to 200 / 5A including necessary wiring and wiring materials complete all as specified and as directed. Make: AE/Kappa/Siemens/L&T/C&S/BCH
All as per item no-19 here-in-before but for CT rating 250/5A to 500/5A all as specified and directed.
Taking down existing defective/unserviceable capacitor from the panel and replace with new heavy duty, aluminium casing,capacitor 5KVAR including necessary wiring and wiring materials complete all as specified and as directed. Make: Havells/Epcos/L&T/C&S/BCH
All as per item no-21 here-in-before but for capacitor 10KVAR all as specified and directed.
All as per item no-21 here-in-before but for capacitor 20kVAr all as specified and directed.
All as per item no-21 here-in-before but for capacitor 25kVAr all as specified and directed.
All as per item no-21 here-in-before but for capacitor 30kVAr all as specified and directed.
Material and labour for dismantling, taking down, checking,cleaning and servicing of switch gear of rating 315 A to 400A MCCB any type contacts with CRC spray including checking the bus bar connections / power cable from Main Bus bar to MCCB and out going cable connections of MCCB, refixing, tightening of incomming and outgoing cables including replacement of Copper / Aluminium lugs as per site requirements and removing the carbon deposit complete all as specified and directed.
All as per item no-26 here-in-before but for switch gear of rating 200 A to 250A MCCB any type complete all as specified and directed.
All as per item no-26 here-in-before but for switch gear of rating 100A to 160 A MCCB any type complete all as specified and directed
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for taking up/ laying cable etc., and getting out for soft / loose soil complete all as specified and as directed.
Taking up existing old/ unserviceable/ burnt under ground cable from the existing positions/ trenches etc., including testing with the help of megger, disconnecting and removing unserviceable portion of cable of following size complete all as specified and as directed. Note: (i) Excavation/ earth work shall be measured and paid seprately under relavent items. (ii) Retrived serviceable bricks from site be properly stacked and reused as protection to UG cable and shall be measured and paid separetely under relevent items. (iii) Serviceable portion of cable shall be relayed as directed and shall be measured and paid separetely under relevent items.
300 Sqmm 3.5 core
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
70 sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Relaying serviceable portion of cable as obtained against item No 30 here-in-before in the trench including necessary connections with suitable lugs complete all as specified and directed . Note: Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid separately under relevent item of schedule.
300 Sqmm 3.5 core
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
70 sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Supply, laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100v grade, with aluminium conductor of following size for replacement of unserviceable portion of cable including connecting up with proper size aluminium lugs, glands wherever necessary in LT panels/ bus bar chamber panel /joints etc., all as per site requirement including testing complete all as specified and as directed by Engr-in-charge. Make -: POLYCAB / NICCO / PLAZA /Havells / KEI. Note:(i) Rates includes supply and fix necessary glands,lugs, etc., (ii) Excavation/ Earth work shall be measured and paid separately under relevent items. (iii) Cable straight through joints if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
300 Sqmm 3.5 core
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
70 sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Spreading riddled earth as obtained from item No.29 here-in-before for UG cable cushioning complete all as specified and as directed. Note: if the required qty of riddled earth not obtained from above item the contractor should bring the same from other location shown (not beyond 50m) including necessary earthwork as directed for borrow pit /trench to obtain the required qty including removing surplus soil without any additional cost and the cost deemed to be included in the rate quoted by the contractor.
Supply and lay pipe galvanised iron tubing light grade of 50mm dia in trenches / under road or floor /on wall / near pole / panel etc., including taking out the corroded old pipe complete all as specified and as directed. Make:Tata/Jindal/Prakash/Surya
All as per item no-34 here-in-before but galvanised iron tubing light grade of 80mm dia complete all as specified and as directed.
All as per item no-34 here-in-before but galvanised iron tubing light grade of 100 mm dia complete all as specified and as directed.
All as per item no-34 here-in-before but galvanised iron tubing light grade of 40 mm dia complete all as specified and as directed.
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and as directed.
Relaying of serviceable bricks as obtained from item ser No.29 here-in-before complete all as specified and as directed.
Material and labour for PCC in roof kerb or mud stops, rounded or chemfered on edges type, road cutting filling etc., PCC 1:3:6 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cms for soft /loose soil complete all as specified and as directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Material and labour for cutting of bituminous road/ floor for laying of pipe/ cables not exc 1.5m wide and not exc 1.5m deep including refilling with material and watering well ramming compacting and making good with PCC 1:2:4 type B-1 suitable thick complete all as specified and as directed. Note: PCC shall be measured and paid separately under respective item of schedule.
Material and labour for straight through cable heat shrinkable joint kit for 1.1 KV grade complete with jointing material and accessories suitable for following size XLPE cable complete all as specified and as directed .
240 sqmm 3.5 core to 300 sqmm 3.5 core
150 sqmm 3.5 core to 185 sqmm 3.5 core
50 sqmm 3.5 core to 120 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Supply, fabricate, install and testing outdoor type LT bus bar chamber box of size 600 x 500 x 400mm from CPRI certified panel manufacturers made out of 3mm thick CRCA sheet steel, powder coated, with front and rear opening including locking facility with pad locks - 02 Nos and slanting cannopy on roof and mild steel channels base frame angles not less than 50 x 50 x 5mm and including TPN aluminium bus bar of 500A capacity for looping and branch connection, the bus bar placed on suitable capacity insulators including danger notice plate on both side, neoprene rubber gasket to make it completely dust and vermin proof complete all as specified and as directed . Note: The quoted rate to be included for taking down old unserviceable PVC/ sheet metal boxes complete carefully and necessary cable connections for incoming and outgoing, new / old cables with, aluminium lugs for connections along with necessary earth work and necessary brick staging including plastering and white wash ec complete all as per site requirement all as specified and as directed.
Surface excavation n.exc 30cms deep but averaging 15cms deep and getting out in soft/ loose soil including removing green vegetation, roots, bushes etc., from surroundings of poles, panels, etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCCB 4 Pole, 415 V, adjustable thermal and fixed magnetic setting, ICS= 100% ICU type 200A with breaking capacity 25KA complete Including taking down old unserviceable all as specified and as directed by Engr-in-charge. Make : Legrand/ Siemens/Schneider/ABB
Supply and fix for MCCB 4 Pole, 415 V, adjustable thermal and fixed magnetic setting, ICS= 100% ICU type 160A with breaking capacity 16KA complete Including taking down old unserviceable all as specified and as directed by Engr-in-charge. Make : Legrand/ Siemens/Schneider/ABB
Supply and fix for MCCB 4 Pole, 415 V,adjustable thermal and fixed magnetic setting, ICS= 100% ICUtype 125A with breaking capacity 16KA complete Including taking down old unserviceable all as specified and as directed by Engr-in-charge. Make : Legrand/ Siemens/Schneider/ABB
Supply and fix for MCCB 4 Pole, 415 V, adjustable thermal and fixed magnetic setting, ICS= 100% ICU type 63A with breaking capacity 16KA complete Including taking down old unserviceable all as specified and as directed by Engr-in-charge. Make : Legrand/ Siemens/Schneider/ABB
Supply and fix for MCCB 4 Pole, 415 V,adjustable thermal and fixed magnetic setting, ICS= 100% ICU type 100A with breaking capacity 16KA complete Including taking down old unserviceable all as specified and as directed by Engr-in-charge. Make : Legrand/ Siemens/Schneider/ABB
Supply, fix, drawn GI wire 4mm complete all as specified and as directed.
Material and labour for preparation of old plastered or unplastered cemented surface and applying two coat of white wash on cemented surface/wall etc complete all as specified
Material and labour for Earthing complete with using GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level, with top edge of the earth plate at a depth of not less than 1.5 mtr below ground and connected to GI earth wire 4 mm by means of GI bolts and nuts,check nuts,washers and GI earth wire protected by GI pipe light grade 15 mm bore and connecting to Panel/DBs etc as per site requirement including alternate layers of charcoal & salt crystal, including necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 for earth chamber, 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete incl watering pipe 20mm dia medium grade with funnel complete with mesh all as shown in electrical plate No. 3 of MES Schedule Part I complete including testing on completion all as specified and as directed . Note :- (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc. (ii) GI earth wire, GI tubing light grade 15mm bore upto 7.5 mtr deemed to be included in the rate quoted by the contractor. (iii) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Supply and fix GI pipe light grade 15mm dia on walls, roof/ laid on floors, ground etc., with all fittings as GI wire protection complete all as specified and as directed. Make:Tata/Jindal/Prakash/Surya
Supply, fix, drawn GI strip 32x6mm complete all as specified and as directed.
26. Material and labour for Earthing complete with using GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level, with top edge of the earth plate at a depth of not less than 1.5 mtr below ground and connected to GI earth strip 32x6mm by means of GI bolts and nuts,check nuts,washers and GI strip protected by GI pipe light grade 40 mm bore and connecting to Panel/DBs etc as per site requirement including alternate layers of charcoal & salt crystal, necessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete incl watering pipe 20mm dia medium grade with funnel complete with mesh all as shown in electrical plate No. 3 of MES Schedule Part 1 complete including testing on completion all as specified and as directed . Note :- (i)Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc. (ii) GI earth strip, GI tubing light grade 40 mm bore upto 7.5 mtr deemed to be included in the rate quoted by the contractor. (iii) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Dismantling and taking out following size cable from existing feeder pillar/ LT panel and removing/ cutting burned part of cable including taking out loop for extension of cable upto required length and fixing /connecting the cable in existing position including necessary nuts, bolts, lugs of approriate size and refixing of cable gland complete all as specified and as directed by Engr-in-charge for following sizes: Note: The quoted rate includes necessary earth work and supply and fixing of lugs of appropriate sizes.
185 sqmm to 240 sqmm
95 sqmm to 120 sqmm
50 sqmm to 70 sqmm
16 sqmm to 35 sqmm
Material and labour for painting to existing LT feeder pillar box/panel boards after preparing/ scraping the surface with emery sheet in all respect for making smooth surface including painting with two coat of exterior enamel paint water proof suitable for existing LT feeder pillar box/panel board surfaces including writing in coming and out going details as per site requirement and as specified complete all as specified and as directed. Note: White washing to copping/pedestal of LT feeder pillar box / panel board shall be measured and paid separately.
Material and labour for welding works to existing LT feeder pillar box/panel board doors including removing broken hinges and supply and fixing new heavy duty hinges as per existing type and qty including writing in coming and out going details as per site requirement and painting with synthetic enamel paint over redoxide on the welded surfaces to make good the disturbed surface and match with existing tint complete all as specified and as directed.
M&L for cleaning and servicing of complete panel with following capacity ACBs, contacts and busbars connections with CRC spray, checking the bus bar connections /power cable from main bus bar to MCCBs and out going cable coonections of MCCB, tightening of all bolts,nuts at power cables/ bus bar/ outgoing cables including replacement of burnt copper/ aluminium lugs as per site requirement, removing the carbon deposit and reconditioning of door lock complete all as specified and as directed .
Panel with ACB capacity upto 630 Amps
Panel with ACB capacity above 630 and upto 1250 Amps
R.P.TRADERS
SIVA ENTERPRISES
D.KUMAR
m/s SRI VALLI ENTERPRISES
SRI VIGNESH BUILDERS
BALA BUILDERS
VKR ENTERPRISES
C SRINIVASAN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .