Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-Finance LANE NO 05 HNO 56 SHIV VIHAR TALAB TILLO JAMMU | ₹14.2 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹14.8 LRejected-Finance LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | ₹14.8 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹15.2 LRejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | ₹15.2 L | L3 | Rejected-Finance Being L3 |
Tender Value
₹16.5 L
EMD Value
₹32,980
Closing Date
5 Mar 2026, 2:00 pmClosed
Executive Engineer
Executive Engineer PWDR and B Gandhi Nagar I/c UWD
Balance work of Guest House at New University Campus University of Jammu Electrical work
2026_UDJK_303820_1
enit 156 dated 13-2-26
Open Tender
Electrical Works
300 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹708
Yes
Executive Engineer PWDR and B Gandhi Nagar I/c UWD
₹32,980
Yes
13 Mar 2026
19 Feb 2026
9 Mar 2026
19 Feb 2026
5 Mar 2026
19 Feb 2026
Based on CPWD Schedule 2022 Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /KEI/Polycab, Plaza Conduit Make - ISI Marked Anchor/High Power /AKG) Equivalent make of required specification to be approved by the Engineer In charge) i.Group ‘A’
ii.Group ‘C’
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (Wire Make ISI Marked Havells/Anchor/KEI/Plaza/polycab Equivalent make of required specification to be approved by the Engineer In charge ) i. 2x1.5 +1x1.5 Sq mm
i. 2x2.5+ 1x2.5 Sq mm
ii. 2x6 +1x6 Sq mm
iii. 4x6 +2x6 Sq mm
iv. 4x10 +2x6 Sq mm
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG) 25 mm dia
Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker suitable for inductive load of following poles of in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make Havells /Anchor/HPL Equivalent make of required specification to be approved by the Engineer In charge) i. Single pole
Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supply and fixing of metal Box of following size(nominal size) on the surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 100mm x 100mm x 60mm deep
200mm x 125mm x 60mm deep
ii.15/16 Amp Switch
iii.3 pin 5/6 Amp Socket
iv.6 pin 15/16 Amp Socket
Telephone socket outlet
Supplying and fixing following way, horizontal type three pole and neutral,sheet steel,MCB distribution board,415 V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators) ( Havells/Anchor /I.A /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 6 way(4+18), Double door
ii. 8 way(4+24), Double door
Supplying & drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel / PVC Conduit as required (Make ISI Marked Havells/Anchor/ KEI Equivalent make of required specification to be approved by the Engineer In charge) 2 Pair
Supply & fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make Havells/ Anchor /Major Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge)
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 100 AMP 16kA TP MCCB
iii. 400 AMP 50kA FPMCCB
iv. 200 AMP 36kA FPMCCB
Earthing with G.I earth plate including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. (600X600X6) mm G.I
P/f of 25X5mm G.I strip on surface/in recess for connections as reqd.
Providing and fixing lighting conductor finial, made of 25 mm dia 300mm long G.I tube having single prong at top, with 85mm dia 6mm thick G.I base plate including holes etc. complete as required.
Providing and fixing G.I tape 20x3mm thick on parapet on surface of wall for Lighting conductor complete as required ( for horizontal run)from earth electrode as required.
Providing and fixing G.I tape 20x3mm thick on parapet on surface of wall for Lighting conductor complete as required ( for vertical run)from earth electrode as required.
Supply and drawing co-axial TV cable RG-6 grade,0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/Recessed steel/PVC conduit as Reqd. (Make ANCHOR/HPL/HAVELLS/C&S Equivalent make of required specification to be approved by the Engineer In charge)
Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T Equivalent make of required specification to be approved by the Engineer In charge) 1 run of cable
Supplying and fixing of following ratings and poles 240/415 volts Isolators in the existing MCB DB complete with connections, testing and commissioning etc. as required (Make Havells /Legrand /Anchor/ C&S/L&T/ Siemen/IA/HPL/Standard Equivalent make of required specification to be approved by the Engineer In charge) a.63 Amp 240 volt Double Pole.
b.63 Amp 415 volt Four Pole Isolator.
Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required(Wire Make ISI Marked Havells/HPL/Anchor/KEI/Plaza/Polycab Equivalent make of required specification to be approved by the Engineer In charge) i.1x1.5 sq mm
iv.2x6 sq mm
Supply and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts washers etc as reqd.
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required. a. Above 8 meter upto 10 meter.
Non-Schedule Items Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) 4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete .
2 feet 9 to 12 watt ,230 volts LED batten type tube light fitting complete
18 to 20 Watt LED recessed/surface mounting 6500 K, 240 Volts Slim Panel down light fittings/luminaries round 150mm to 225mm Dimensions.Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge)
2X2 Recess Led Panel 595X595mm 36W +/- 1W Recess mounted fixture with minimum system efficiency of 100lm/W and minimum 3800 lumens, P.f is 0.9 with THD 10% CRI 80 the Led with life of 50000hrs.the LEDs used in the luminaries shall have CCT of 5700K to 6500K with CRI of minimum 80 Protection of 3kV. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge)
Supply/installation of the following type of outdoor decorative energy efficient LED flood light/gate lights and Street lights luminaries complete with all accessories connection testing and commissioning as required. Make (Bajaj/Surya /Havells/ C&S/ HPL /compact/ Halonix) 45 to 50 watt,230 volts IP 66/IP65.(Street Light)
45 to 50 watt,230 volts IP 66/IP65.(Flood Light)
90 to 100 watt,230 volts IP 66/IP65. (Flood Light)
Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/ insulated conductors/strips etc. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Jai maa/KED) MAIN NORMAL CUM EMERGENCY PANEL of 3nd Floor a. INCOMING Space for 1 No. 400 Amp MCCB 50 KA of 2nd FLoor Power, Light amd A.C Load Space for 125 amp. Four Pole Changeover Switch. b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. BUS BAR Space for 1 No. 400 Amp TPN Al. Bus bar of equal cross section for power load. And Space for 300A TPN Al.bus bar of equal cross section for Light Load. d. OUTGOING Space for 2 No. 100 Amp 4 pole MCCB of 30 kA Space for 2 No. 200 Amp 4 pole MCCB of 35 kA Dimensions (5’x 4' x 1’6"
MAIN NORMAL CUM EMERGENCY PANEL of Main Guest House a. INCOMING Space for 1 No. 400 Amp MCCB 50 KA of 2nd FLoor Power, Light amd A.C Load Space for 400 amp. Four Pole Changeover Switch. b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. BUS BAR Space for 1 No. 400 Amp TPN Al. Bus bar of equal cross section for power load. And Space for 300A TPN Al.bus bar of equal cross section for Light Load. d. OUTGOING Space for 5 No. 100 Amp 4 pole MCCB of 30 kA Dimensions (5’x 4' x 1’6"
Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable
3 ½ core 120 sq mm armoured cable
3 ½ core 50 sq mm armoured cable
4 ½ core 95 sq mm armoured cable
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 1 to 3 star rated energy efficient .(Make: Havells /Anchor/USHA /Crompton) Equivalent make of required specification to be approved by the Engineer In charge)
Supply /Installation testing and commissioning of 450 mm sweep wall mounted fan including the electronic regulators and connection with testing and commissioning etc complete Job BEE 1 to 3 star rated energy efficient. Make: (Anchor /Bajaj /Cromton/ Havells Equivalent make of required specification to be approved by the Engineer In charge )
Supply, installation, testing, commissioning of 300 mm sweep BEE 1 to 3 star rated energy efficient exhaust fan. Make: ( Anchor/Havellls/Bajaj/Crompton Equivalent make of required specification to be approved by the Engineer In charge)
Supply & installation of CAT 6 2 module toll less information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required.(Make Legrand/Delton/Havells/HPL/Anchor)
Supply and installation of Singlex Face Plates along with clearly printed labels and holders complete as required(Make Legrand /Havells / Anchor/D Link /HPL)
S/F of 32mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd.
P/F following rating 230 volts energy saver LED Lamps and LED Tubes 4’ long (Make :Philip /Havells/Bajaj/ Surya/ Crompton/Compact/Halonix Equivalent make of required specification to be approved by the Engineer In charge) i.8 to12 watt LED
ii.18 to 25 Watt LED
Supplying and fixing bus bar chamber with 4 strips bus bar of following size, made of the copper, suitable for following capacity complete with all accessories including connections, earthing the body as required. 100 Amp
Supplying and fixing following ways horizontal type MCB Board 230V on surface/in recess complete interconnections including powder painted etc. as required (But without MCB/SPN.) i.4 way Encloser (Make :-Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge )
Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge)
Providing/fixing Ding Dong wall bell including connection as required (Anchor/HPL/Klick Equivalent make of required specification to be approved by the Engineer In charge)
P/laying of 100 mm dia heavy duty PVC pipe in ground including digging the pit and refilling complete job. (prince/supreme/Uniplas)
Supply of swaged type steel tubular pole of following height duly painted with two coats of red oxide and two coats of silver paint made of Mild Steel conforming to IS 2713 part III of 1980 designated as 410 SP 30 HT 9 mtr planted in 1.5 m deep pole pit to be dug for the purpose, welded with (300x300x6) mm base plate at bottom including filling back the pit with cement concrete excavation 1:3:6 (1 cement: 3 corse sand:6 graded stone aggregate 40 mm nomial size) (excluding the cost of CC). The planting depth of the pole shall be 1/6 th 0f pole a) 9 mtr height.
Supply of swaged type steel tubular pole of following height duly painted with two coats of red oxide and two coats of silver paint made of Mild Steel conforming to IS 2713 part III of 1980 designated as 410 SP1 LT 8 mtr planted in 1.5 m deep pole pit to be dug for the purpose, welded with (300x300x6) mm base plate at bottom including filling back the pit with cement concrete excavation 1:3:6 (1 cement: 3 corse sand:6 graded stone aggregate 40 mm nomial size) (excluding the cost of CC). The planting depth of the pole shall be 1/6 th 0f pole a) 8 mtr height.
Supply of following size ACSR conductor of required aluminum and steel strands including binding etc. as required as per IS O 398 part 2 a) 7/2.11 mm to 7/4mm
Supply, fabrication of following sizes of channels, angles and flat iron including drilling holes for insulators and painting with primer and silver paint. A)Channel (75x40x6)mm
….do…. Angle (50x50x6)mm
….do…. Flat iron clamps suitable for LT/HT poles (50x6)mm.
Supply and fixing of 125Amp onload I-O-II Four pole with advanced neutral on load change over switch confirms to IS 13947 (Part-3) IEC:609473) (Make I.A/Havells/HPL/Crompton Equivalent make of required specification to be approved by the Engineer In charge)
Supply and fixing of 250Amp onload I-O-II Four pole with advanced neutral on load change over switch confirms to IS 13947 (Part-3) IEC:609473) (Make I.A/Havells/HPL/Crompton Equivalent make of required specification to be approved by the Engineer In charge)
Supply and fixing of (75X75)mm press fit type PVC Trunking for drawing the electric wires/Cables.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_986804.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid