Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹11.9 L+₹74,448.10 (6.67%)Rejected-Finance | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹13.7 L+₹2.6 L (23.2%)Rejected-Finance AT DUNGAMAL NH 5 POST NB CHILKA VIA BALUGAON DIST KHURDA ORISSA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹14.5 L+₹3.4 L (30.2%)Rejected-Finance AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L4 | Rejected-Finance Being L4 bidder | |
| 5 | L5₹18.1 L+₹6.9 L (62.0%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L5 | Rejected-Finance Being L5 bidder |
Tender Value
₹14.6 L
EMD Value
₹29,120
Closing Date
1 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Avinash Mishra IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
REPAIR AND MAINTENANCE OF INTERNAL AND EXTERNAL ELECTRIFICATION WATER SUPPLY DG SET AND COOLING APPLIANCES
2022_MES_549807_1
8305/BBSR/03/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Gopalpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (I) (CG) Bhubaneswar
₹29,120
Yes
25 Nov 2022
3 Sept 2022
3 Oct 2022
3 Sept 2022
1 Oct 2022
17 Sept 2022
3 Sept 2022 - 10 Sept 2022
Amount
S & F in replacement wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required in existing conduit/new conduit of suitable size with accessories complete for 2 runs 1.5 sqmm and 1 run of 1.5 sqmm complete all as specified and directed.
S & F in replacement wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required in existing conduit/new conduit of suitable size with accessories complete for 2 runs 2.5 sqmm and 1 run of 2.5 sqmm complete all as specified and directed.
S & F in replacement of switch piano 5 Amp flush type one way single pole 230 Votls, 50 Hz, AC complete all as specified and directed.
S & F in replacement of celing rose surface backlite with 2-3 terminal 65x30mm 230 Votls, 50 Hz, AC complete all as specified and directed.
S & F in replacement of switch socket combination 5 Amp flush type 2 in 1 type, 3 pin, flush type 230 volt 50 Hz, AC complete all as specified and directed.
S & F in replacement of switch socket combination 5/16 Amps flush type universal 5 in 1 type, 5 pin, flush type 230 volt 50 Hz, AC complete all as specified and directed.
S & F for in replacement of Ding Dong type Bell, AC, 230V,50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S & F in replacement of switch bell/Buzzer push,flush type 5 Amp, 230Volt, 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S & F in replacement of stepped type electronic fan regulator stepped socket type ,100W ,230V ,50Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S & F in replacement of Capacitor for ceilling fan 2.5 Mµ suitable for 1200 mm sweep complete all as specified and directed. ( Make - Bajaj / Crompton or Equivalant)
S & F in replacement of Capacitor for Exhaust fan 4.0 Mµ suitable for 230 mm sweep complete all as specified and directed. ( Make - Bajaj / Crompton or Equivalant)
Taking down ceiling / Exhaust fan, sealing cable end, dismantling blades and removing fan and blades for repair and rewinding refixing the same and complete all as specified and directed..
Material and labour for rewinding of ceiling fan of 1200 mm sweep including oiling, greasing complete all as specified and directed.
Material and labour for rewinding of exhause fan of 300 mm sweep including oiling, greasing complete all as specified and directed.
S & F in replacement Bush / Ball bearing (type - Single row deep groove ball bearing) for ceiling fan 1200mm sweep bearing no -6201/ 6202 or as per sample complete all as specified and directed. Make - TATA / SKF)
S & F in replacement of MCB SP 6 to 32 Amp, 10 Ka, C series , 230 Volts, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand).
S & F in replacement of MCB SPN 6 to 32 Amps, 10 Ka C series, 230 Volts, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand)
S & F in replacement of MCB TPN 10 Ka "C" series 415 Volt 40 to 63 Amps, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand)
Supply and fixing in replacement of MCCB 4 pole ,100 amp rating of 16 KA adjustable type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed.
Supply and fixing in replacement of LED T-5 Batten type tube light fitting of 20 watt suitable for surface and wall mounted with polycarbonate and integrated LED drive including twin core twisted flexiable copper conductor cable of size 1 sq mm from connector to ceilling rose complete all as specified and directed. (Make:- Crompton Cat Part No.CCS-102-20-65-SL-DP-NWH or equivalent in Wipro/ Phiiips/ Havells)
S&Fin replacement A new generation LED T5 batten application 09/10 W LED 6500 K LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready including twin core twisted flexiable copper conductor cable of size 1 sq mm from connector to ceilling rose complete all as specified and directed. Make:- Crompton Cat NoCCS-102-10-65-SL-DP-NWH or equivalent in wipro/Phillps/ Havells)
Supply and fixing in replacement of energy saving environmental friendly, long life LED Lexon Street light fitting 45 watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperete driver compartment with IP 66 protection complete all as specified and directed (Make :Crompton Cat Part No.LSTS-45-CDL-M or equivalent in Philips/ Havells)
Supply & Fixing in replacement of outdoor spotlight with stake LED lawn flood light of different colour lumination of10/12 W complete all as specified and directed.
Taking down of Street light fitting complete of Cap 45 / 40 Watt LED street light including repair and replacement of Electronic Driver as per required and refixing the same existing position complete all as specified and directed.
Supply and Laying inreplacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 Sq mm 4.0 core in trenches or fixed on wall/floor/poles complete with lugs & glands complete all as specified and directed.
Supply and Laying inreplacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sq mm 4.0 core in trenches or fixed on wall/floor/poles complete with lugs & glands complete all as specified and directed.
Supply and Laying inreplacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 10 Sq mm 2.0 core in trenches or fixed on wall/floor/poles complete all as specified and directed.
Supply and fixing of LED Bollard blink light , Contemporary UFO shape design bollard with minimum upward light component, ensuring excellent distribution and high system lumen efficacy suitable for 10 W LED complete with junction box of size 104x104x70mm suitable for 10x2 core cable including suitable PCC foundation complete all as specified and directed. Make : Cat Part No : LBLSN-10-CDL of Crompton or equivalent of make as mentioned in PS.
Repair of air break gang operated switches vertical/horizontal type such as repair/ replacement of broken/worn out components & insulators and greasing the moveble parts ( Male fimale parts) for smoth functioning complete all as specified and directed.
Supply and fixing in replacement of air break Gang opeting Drop Out (GODO) switch vertical / horizontal typeTriple pole, mechanically operated, mounted on 12 insulators and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11 KV complete all as specified and directed.
S&F in replacement of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11KV greasing the moveble parts ( Male fimale parts) for smoth functioning complete all as specified and directed.
Supply and fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing in replacement of Cable jointing kit for LT cable for indoor/outdoor termination complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 25 Sqmm complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line etc complete all as specified and directedfor laying of cable, errection of poles, stay and pipe line, complete all as specified and directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete complete all as specified and directed.
Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified and directed.
Supply & fixing DWC ( double wall corrugated) HDPE pipe suitable for up to 50sqmm for cable protection complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 35 KA on existing LT panel board from the LT panel board complete all as specified and directed. ( Make : Legrand or equivalent in ABB/Schnieder)
M & L for cable fault finding of any size at any location complete with rectification uly joined by suitable jointing kit above 25 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of MCCB 4 pole , 63 amp rating of 16 KA on existing LT panel board from the LT panel board complete all as specified and directed. ( Make : Legrand or equivalent in ABB/Schnieder)
Supply and fixing in replacement of MCCB 4 pole , 125 amp rating of 16 KA on existing LT panel board from the LT panel board complete all as specified and directed.( Make : Legrand or equivalent in ABB/Schnieder)
Supply & Fixing in replacement Street light junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers complete all as specified and directed. (Make Hensel/ model No-KF2525B or Sintex or equivalent as approved)
S&F in replacement bldg sesurity light 25W LED energy saving and environmental friendly long life 25 Watt LED light made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having iP65 protection and impact resistance of iK07 with 10KV Built-in surge Protection device including twin core flexiable copper conductor cable of size 1.5 sq mm from connector to light point complete all as specified and directed. Make:- Havells, Code No-ENDURA SUN DOWN SL 25LED 765PASYBOPCIHD or equivalent of make as mentioned in PS.
Taking down of Bldg security light fitting complete of Cap 25 / 20 Watt LED street light including repair and replacement of Electronic Driver as per required and refixing the same existing position complete all as specified and directed.
M&L for servicing of DG Set through authorised agency "B" check in replacement of Lube oil(15W40). fuel filter, Oil filters, Coolant top up will be done. B- Check activities will be done along with Air filters replacement,Tapped set replacement if required ( Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil) etc and refitting for DG set including drain out (used) engine oil and filling new engine oil of Capacity 62.5 KVA & 40KVA Gen Set complete all as specified and directed. Note:- (a) Engine oil, Air Filter, Fuel Filter, Oil Filter to be measured and paid separately as supply only under respective items of schedule 'A'.
Supply only engine oil suitable for diesel generator set (Oil 15W/40) complete all as specified and directed. Make: Servo/ HP / Bharat Petroleum.
Supply only coolant suitable for radiater of DG sets complete all as specified and directed. Make: HP/TVS or Equivalent.
Supply Fuel Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
Supply Oil Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
Supply Air Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
Supply in replacement of battery terminal brass(heavy duty)with nuts & bolts for battery (as per sample) complete all as specified and directed.
M&L repair of radiator, Dismantling the radiator from DG set of any capacity after removing hose pipe connection, nut, bolts etc and taking out the same to civil workshop for repair and descaling of radiator using descaling chemical etc as approved to remove mud/deposit on fins and/in copper tubes including bracing of copper tubes for arresting of leakage and re-fixing after replacement of unserviceable hose pipes and clamps for DG Capacity uptp 62.5 KVA complete all as specified and directed.
M & L for repair of Dynamo of 12/24 Volts by replacing unserviceable Groove wheel/ armature including testing and commissioning complete all as specified and directed.
M&L for dismentling and taking out fuel injection pump for servicing from DG set of any type/make and capacity uptp 62.5 KVA disconnection of fuel injector line, carrying complete overhauling/ servicing of injector pump, ,calibration of fuel pump as per manufacturer instruction , assembling the same with DG set properly in original postion, checking the allignment , making proper fuel connection and testing for smooth opreation complete all as specified and directed.
Supply & fixing in replacement of old unservicable feed pump for fuel injection pump complete assy for DG upto 62.5 KVA complete all as specified and directed.
Supply and fixing, in replacement, Radiator cap suitable for DG Set of any type / make and capacity, complete all as specified and directed.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed.
Supply and fixing, in replacement of Old unserviceable RPM CABLE complete all as specified and directed.
M & L for DG set Controller of capacity upto 62.5 KVA for automation operation of DG set compelete with connected acessories complete all as specified and directed.
Supply and fixing, in replacement, of Electronic Automatic Voltage Regulator (AVR) suitable for DG Set of upto 62.5 KVA capacity, with and including taking out old AVR and making all connection, testing for smooth operation complete all as specified and directed.
Material & labour for carrying out complete overhauling / servicing of DG set panel/ control panel, including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as specified and directed.
M & L for servicing of Governor of Dg set of capacity 62.5 KVA complete with made functional including change of spare parts if required complete all as specified and directed.
M & L for servicing of Water pump of Dg set of any capacity upto 62.5 KVA complete with made functional including change of spare parts if required complete all as specified and directed.
Supply and fix DG set diesel tank cap with locking arrangements complete as existing complete all as specified and directed.
M&L for replacements of automatic battery charger of 24 Volt 10 A complete all as specifed and directed.
Servcing of battery of 180 AH 12 V capacity by replacing distelled water and checking of specific gravity complete all as speicifed and directed
Repair of Self Starter 24 volts/12 volts DC, disconnecting and dismantling and repairing with replacement of bendex-01,Rewinding of armature, Field coil, Carbon Bush etc reassembling and refitted at its original position including testing of the complete self starter of Capacity 62.5 KVA Gen Set complete all as specified and directed.
Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified and directed.
M&L for complete routine test of transformer of Cap 200 & 250 KVA (as per IE rules) with authorised agency as per the dirction of Engr-in-Charge and submit the all routine test certificate by the authorised agency to Engr-in-Charge for maint of our record of any cpacity of trnasformer complete all as specified and directed.
Supply and Replacement of breather with silica gel as pr existing complete all as specified and directed.
Taking up/down GI tubing from trenches , duct, wall, roof or in any position with all fittings for re-laying /refixing of serviceable pipes and removing the unserviceable pipes for 50 mm dia complete all as specified and directed.
All as per item No-71 above but 25 sqmm dia complete.
Supply and fixing of GI tubing medium grade of 25 mm dia fixed on wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and directed.
All as per item No-73 above but 50 sqmm dia complete.
Supply and fix in replacement of Valves, Sluice, flanged of class 1.6 PN ,80 mm (3”)dia complete all as specified and directed.
Supply and fix in replacement of Gun-metal, globe or gate valves 50 mm dia,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in replacement of Gun-metal, globe or gate valves 25 mm dia,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in replacement of Non Return Sluice Valve 50 mm dia of class 1.6 PN complete all as specified and directed.
Re-laying old serviceable GI tubing after throughly cleaned the inside of pipes and re-running the old screws threads as required and re-fixed/re-laying in trenches wall or roof etc complete for 50 mm dia complete all as specified and directed.
All as per item No-79 above but 25 sqmm dia complete.
Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing & rubber coppling etc for smooth running and replacement of packing gaskets, shaft sleeve, neck ringnut bolts and washers etc, with necessary oiling and greassing of 12.5 HP pump complete all as specified and directed.
Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing & rubber coppling etc for smooth running and replacement of packing gaskets, shaft sleeve, neck ringnut bolts and washers etc, with necessary oiling and greassing of 5.0 HP pump complete all as specified and directed.
Supply only ball bearing 6310-ZZ/C3 complete all as specified and directed.Make:- (SKF, TATA)
Supply only ball bearing 6206-ZZ complete all as specified and directed. Make:- (SKF, TATA)
Cleaning and removing yearly all scales and deposited materials in Under ground water sump of 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud outside the premises & writting date of cleaning, tank capacity shall be deemed to include in the above item rate.
Cleaning and removing yearly all scales and deposited materials in Overhead tank 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud outside the premises & writting date of cleaning, tank capacity shall be deemed to include in the above item rate.
S & F in replacement of Brass Foot Valve for suitable of 50 mm dai GI Tube complete all as specified and directed.
S & F in replacement for repair, cleaning and servicing of automatic star delta starter of capacity 15 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified and directed. (Note : Major defective parts will be measured and paid seperetely under relevent item as supply only)
Dismantling and taking down of motor from pump after disconnection of mechanical tyre coupling and unbolting from foundation base plate,discconection of electric connection from terminal loading/unloading the motor to vehicle and transportation of the motor to workshop, cutting the burnt winding and clean the rotor & stator with CTC or other cleaning matterial and rewinding of stator winding with supper enameled copper wire as per existing the size/gauge wire and turn of the previous winding, insulating the leads with insulating tubes and varnishing the stator with good quality of insulating varnish . Afterward heating the stator in heat chamber for continous 2 days for better insulation resistance reassembling the stator & rotor carefully after replacement of worn out bearings, transportation of motor from workshop to its original location, unloading the motor and placing it on base frame, connection of motor with pump with tyre coupling and fixing to the base frame after checking up the alignment, testing of motor with megger for checking of insulation resistances, electric connection of motor to the control panel, testing on load for continous running for 3 hrs complete all as specified and directed of capacity upto 12.5 HP Induction motor.
Taken up submersible pump of any capacity from borewell for carry out repair work of pump and rewinding of motor including refix the pumpset complete with testing complete all as specified and directed.
Supply only Calcium Hypochlorite granules 65% to 70% with CIAS (ALTOCH-GP) for porteble water in 45 kg drum complete set all as specified and directed.
M/L for earthing complete with galvanised steel plate earth electrode of size 60cmx 60cmx6mm thick, burried in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 m below normal ground level, connected with GI wire 4 mm dia earth lead by means of nuts, bolts,check nuts and washers and galvanised iron of steel 15mm bore pipe medium grade for protection connected to main switch board or main control board all as specified and directed including , 20mm dia GI pipe medium grade for watering,funnel with wire mesh, PCC pit with RCC cover including necessary earth work excavation and removal etc complete all as specified in plate No 3 of SSR Part-I 2009 complete all as specified and directed.
M&L for disconnection and dismantling of indoor and outdoor untis of split type AC of capacity 2 Ton installed at OTM Accn Gopalpur , the out door unit fixed at an height of 8 to 10 ft above from the floor level and comprising through cleaning ,washing, lubricating of all moving parts including replacement of worm out screws , bolts washers and checking of condenser leak test, pressure tes etc and testing the complete unit after completion of work complete all as specified and directed.
M&L for disconnection and dismantling of indoor and outdoor untis of split type AC of capacity 1.5 Ton installed at OTM the out door unit fixed at an height of 8 to 10 ft above from the floor level and comprising through cleaning ,washing, lubricating of all moving parts including replacement of worm out screws , bolts washers and checking of condenser leak test, pressure tes etc and testing the complete unit after completion of work complete all as specified and directed. Note:- (a) Refrigerant gas R-410 (b) Compresssor to be measured and paid separately as supply only under respective items of schedule 'A'.
Supply and charging refrigerant gas R-410 up to required level including cleaning the capillary and air filter evaprator condenser, including testing of leakage or pressure test suitable for 1.5/2 ton split AC complete all as specified and directed.
Supply of hermetically sealed compressor unit of 1.5/2 Ton capacity split type AC including replacement of copper tube , capillary strainer etc and testing after completion of work complete all as specified and directed. (Make: Kirloskar/ LG/ Hitachi)
All as per Item No. 97 but for Deep freezer of capacity upto 500 Ltr
S & F in replacement of sheet metal enclosure box including plug and socket MCB 20A complete all as specified and directed.
Supply only in replacement the following capacity of starting/running capacitor suitable for 1.5/2 Ton split type AC complete all as specified and directed. ( Make : Epcos/ Siemens)
Capacity of 10/20 MFD
Capacity of 36 MFD
Supply of starting relay complete with knob of compatable size for 2 Ton capacity split type AC complete all as specified and directed.
Supply of thermostat suitable for 1.5 /2Ton capacity split type AC complete all as specified and directed.
Supply of PCB card suitable for 1.5 /2Ton capacity split type AC complete all as specified and directed
M&L brick massonary valve pit with 230 mm thick brick wall chamber of size internally (750x750x750mm ) with Plastering in Cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 Cement mortar 15mm thick, PCC 1:4:8 type D2 by using 40mm gradded aggregate foundation of size 1300x1300 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X6 mm thick angle iron frame and 3.15 mm thick MS Sheet as cover with two Nos of 150 mm length hinges and one No handle made out of MS round bar 10 mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed.
S & F in replacement Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 Sump cover of size 0.70 x 0.65M with 40X40X6 mm thick angle iron frame and 3.15 mm thick MS Sheet as cover with two Nos of 150 mm length hinges and one No handle with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed.
Supply and fixing in replacement of Post -top light , new generation, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED suitable for 15 W LED suitable for highlighting architectual feature complete all as specified and directed. Make Havells Cat No CORALMINIPT15WLED757PSYMTOPC or equvalent to Make CG, Bajaj & Philips
M/S KAMAL KEE ENGINEERS WORK
HARI HARA NAYAK
PRADIPTA KUMAR PANI
KRISHNA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .