| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC BEING LOWEST, L1 | |
| 2 | L2₹48.1 L+₹3.8 L (8.61%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L2 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 3 | L3₹48.4 L+₹4.2 L (9.39%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L3 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 4 | L4₹48.8 L+₹4.5 L (10.2%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 5 | L5₹49.3 L+₹5.0 L (11.2%)Rejected-Finance 25A R R SAMY LANE COIMBATORE TAMILNADU COIMBATORE TAMIL NADU 641009 | COIMBATORE | TAMIL NADU | 641009 | L5 | Rejected-Finance BEING NOT LOWEST TENDER. |
| Sl No | Description | Qty | Unit | SUPER COOL L1 | KUMAR AGENCIES L2 | devan enterprises L6 | rvelectricals L5 | SARAVANARAJA CONSTRUCTIONS L7 | p.chinnasamy L8 | KSR AND COMPANY L3 | NAVEEN ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of 20 to 25 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with output of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: LCA Hanger No-I, II & III - 09 Nos, Rotable section & Spl power supply room - 06, Fadec - 01, Old TRCD - 02, CRRW - 01, RSDL - 01, IFCS - 01, Avionics Complex - 01 (Total 22 Nos) | 4 | EACH JOB | 15,000 ₹60,000 | 10,200 ₹40,800 | 11,000 ₹44,000 | 9,700 ₹38,800 Lowest | 10,200 ₹40,800 | 10,832 ₹43,328 | 10,150 ₹40,600 | 9,800 ₹39,200 |
| 2.00 | Comprehensive maintenance of 30 to 40 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with output of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Old TRCD- 02 (Total 02 Nos) | 4 | EACH JOB | 19,000 ₹76,000 | 10,000 ₹40,000 | 13,000 ₹52,000 | 10,500 ₹42,000 | 9,500 ₹38,000 Lowest | 10,132 ₹40,528 | 10,200 ₹40,800 | 9,600 ₹38,400 |
| 3.00 | Comprehensive maintenance of 60 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with output of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Avionics Complex - 02 (Total 02 Nos) | 4 | EACH JOB | 55,000 ₹2,20,000 | 12,200 ₹48,800 | 12,900 ₹51,600 | 13,000 ₹52,000 | 12,110 ₹48,440 | 12,902 ₹51,608 | 12,500 ₹50,000 | 11,500 ₹46,000 Lowest |
| 4.00 | Comprehensive maintenance of 5 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with out put of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: CRRW -01 No & Old TRCD- 01 No (Total 02 Nos) | 4 | EACH JOB | 6,000 ₹24,000 Lowest | 9,000 ₹36,000 | 9,300 ₹37,200 | 9,500 ₹38,000 | 8,550 ₹34,200 | 9,302 ₹37,208 | 9,200 ₹36,800 | 8,200 ₹32,800 |
| 5.00 | Comprehensive maintenance of 1.25 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with out put of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Aplab including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete as specified and as directed by the Engineer-in-Charge
Location: 33 Sqn Tarang Lab - 01 No | 4 | EACH JOB | 4,500 ₹18,000 Lowest | 8,000 ₹32,000 | 8,100 ₹32,400 | 8,500 ₹34,000 | 7,010 ₹28,040 | 8,102 ₹32,408 | 8,000 ₹32,000 | 6,500 ₹26,000 |
| 6.00 | Comprehensive maintenance of 4 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with out put of 3 ph, 4 wire, 115 AC /200V, AC, 400 HZ of make M/s Aplab including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete as specified and as directed by the Engineer-in-Charge
Location: 33 Sqn Tarang Lab - 01 No | 4 | EACH JOB | 5,500 ₹22,000 | 8,200 ₹32,800 | 750 ₹3,000 Lowest | 800 ₹3,200 | 8,865 ₹35,460 | 750 ₹3,000 Lowest | 8,200 ₹32,800 | 5,800 ₹23,200 |
| 7.00 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 12 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, oopening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: LCA Hanger No-I, II & III - 09 & Fadec -01 (Total 10 Nos). | 4 | EACH JOB | 55,000 ₹2,20,000 | 15,000 ₹60,000 | 15,130 ₹60,520 | 15,300 ₹61,200 | 16,200 ₹64,800 | 15,130 ₹60,520 | 15,100 ₹60,400 | 12,000 ₹48,000 Lowest |
| 8.00 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 5 to 10 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Avionics Complex-02, EW- Bldg-01 (Total 03 Nos) | 4 | EACH JOB | 13,000 ₹52,000 Lowest | 15,400 ₹61,600 | 15,180 ₹60,720 | 15,480 ₹61,920 | 16,015 ₹64,060 | 15,180 ₹60,720 | 15,200 ₹60,800 | 13,000 ₹52,000 Lowest |
| 9.00 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 15 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: AVRO Hangar-01, TRCL- Bldg-01 (Total 02 Nos) | 4 | EACH JOB | 13,000 ₹52,000 Lowest | 16,800 ₹67,200 | 16,950 ₹67,800 | 17,000 ₹68,000 | 16,500 ₹66,000 | 16,950 ₹67,800 | 16,800 ₹67,200 | 15,000 ₹60,000 |
| 10.00 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 3.84 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Special power supply room -02 Nos. | 4 | EACH JOB | 10,000 ₹40,000 Lowest | 15,400 ₹61,600 | 15,150 ₹60,600 | 16,000 ₹64,000 | 15,800 ₹63,200 | 15,150 ₹60,600 | 15,400 ₹61,600 | 12,000 ₹48,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
20 Jun 2026, 6:00 pmClosed
GE AF SULUR
KANGAYAMPALYAM
PERIODICAL SERVICES /MAINT /REPAIR OF UPS, SFC, DC RECTIFIER AND OTHER CERTAIN EQUIPMENTS IN TECHNICAL AREA AND OTHER LOCATIONS INCLUDING CERTAIN MISC WORKS AT AF STN SULUR
2026_MES_768825_1
8867/E8
Open Tender
Miscellaneous Works
Item Rate
300 days
GE AF SULUR
PLEASE REF TO TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE AF SULUR
₹96,000
2 Aug 2026
30 May 2026
22 Jun 2026
30 May 2026
20 Jun 2026
13 Jun 2026
1 Jun 2026 - 7 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance of 20 to 25 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with output of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: LCA Hanger No-I, II & III - 09 Nos, Rotable section & Spl power supply room - 06, Fadec - 01, Old TRCD - 02, CRRW - 01, RSDL - 01, IFCS - 01, Avionics Complex - 01 (Total 22 Nos) | 4 | EACH JOB | - | - |
| 2 | Comprehensive maintenance of 30 to 40 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with output of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Old TRCD- 02 (Total 02 Nos) | 4 | EACH JOB | - | - |
| 3 | Comprehensive maintenance of 60 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with output of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Avionics Complex - 02 (Total 02 Nos) | 4 | EACH JOB | - | - |
| 4 | Comprehensive maintenance of 5 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with out put of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Power one Micro systems including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: CRRW -01 No & Old TRCD- 01 No (Total 02 Nos) | 4 | EACH JOB | - | - |
| 5 | Comprehensive maintenance of 1.25 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with out put of 3 ph, 4 wire, 115 AC /200V, AC, 400 Hz of make M/s Aplab including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete as specified and as directed by the Engineer-in-Charge
Location: 33 Sqn Tarang Lab - 01 No | 4 | EACH JOB | - | - |
| 6 | Comprehensive maintenance of 4 KVA static frequency converter with input supply of 3 phase, 415V, 50 Hz with out put of 3 ph, 4 wire, 115 AC /200V, AC, 400 HZ of make M/s Aplab including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete as specified and as directed by the Engineer-in-Charge
Location: 33 Sqn Tarang Lab - 01 No | 4 | EACH JOB | - | - |
| 7 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 12 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, oopening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: LCA Hanger No-I, II & III - 09 & Fadec -01 (Total 10 Nos). | 4 | EACH JOB | - | - |
| 8 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 5 to 10 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Avionics Complex-02, EW- Bldg-01 (Total 03 Nos) | 4 | EACH JOB | - | - |
| 9 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 15 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: AVRO Hangar-01, TRCL- Bldg-01 (Total 02 Nos) | 4 | EACH JOB | - | - |
| 10 | Comprehensive maintenance of DC power supply (rectifier) 28Volts, DC, out put 3.84 KW, with input supply of 3 phase, 415V, 50 Hz of make M/s Power one Micro systems, including attending day to day complaints, isolating converter from system, opening up, examining the accessories parts, cleaning, soldering as required, testing and connecting back with the systems complete all as specified and as directed by the Engineer-in-Charge.
Location: Special power supply room -02 Nos. | 4 | EACH JOB | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_860971.xls
BOQ • 0.44 MB
COMMON_PAGES_8867.pdf
Tender Documents • 0.56 MB
PS_8867.pdf
Additional Documents • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .