Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC BANDARAILAH MALDA | MALDA | MALDA | WEST BENGAL | ₹7.4 L | L1 | Accepted-AOC L1-Accepted |
| 2 | L2₹7.4 LRejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 UDYAM WB 23 0013338 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | ₹7.4 L | L2 | Rejected-Finance Higher than L1 |
| 3 | L3₹7.5 LRejected-Finance 21 KBM CHAKDAH P O P S CHAKDAH DIST NADIA PIN 741222 | CHAKDAH | NADIA | WEST BENGAL | 741222 | ₹7.5 L | L3 | Rejected-Finance Higher than L1 |
| Sl No | Description | Qty | Unit | DEY ENTERPRISE L2 | DAS CONSTRUCTION L3 | NABAUDYAG ELECTRICAL ENGINEERING CO OP. SOC. LTD. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and Delivery at site of Full Bore Electro- Magnetic Flow Meter of size DN 750 as per folowing specification given below.
Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05cu.m /Pulse) With LCD 4 line backlit Display and configuration through Bluetooth, Calibration lab as per ISO 17025 , Accuracy: 0.5% , +/- 2mm/sec, Inbuilt Measuring, Reference, grounding & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner ,Supply: 24V DC or 230VAC.
Make: Endress + Hauser/Other approved make. | 1 | No | 5,54,900 ₹5.5 L | 5,56,600 ₹5.6 L | 5,54,345 ₹5.5 L |
| 2.00 | Automatic Servo Voltage Stabilizer (1KVA) for Flow Meter along with Panel for Flow Transmitter Latest Digital Display and Microprocessor Controlled.
• Copper variacs that are very long lasting & Durable.
• Low voltage, high voltage cut out with automatic timer system inbuilt.
• Output voltage accuracy of 1% tolerance and choice of 230V (for single
phase).
• Efficiency of over 98%, high precision output and 24 hours duty capable.
• Maintenance free,
• High speed of voltage correction up to 60 volts/ second.
• Option of air-cooled Stabilizer. | 1 | No | 25,200 ₹25,200 | 25,400 ₹25,400 | 23,331 ₹23,331 |
| 3.00 | Installation of the Flowmeter (as in Sl No. 1.00) along with servo voltage stabilizer (as in sl no. 2.00) at the specified position within the common delivery pipe line (DN 750) of pumping machineries by cutting pipe, prepairing edge & fittings & other acessories mending the damage pipeline including installation of display unit drawing of required power line by supplying & laying of required size of cable including testing commissioning all complete as per entire satisfaction of EIC. | 1 | Item | 44,700 ₹44,700 | 45,200 ₹45,200 | 43,326 ₹43,326 |
| 4.00 | Add GST @ 18% | 1 | item | 1,12,464 ₹1.1 L | 1,12,896 ₹1.1 L | 1,11,780.36 ₹1.1 L |
| 5.00 | Add Cess @ 1% | 1 | item | 7,372.64 ₹7,372.64 | 7,400.96 ₹7,400.96 | 7,327.82 ₹7,327.82 |
Tender Value
Refer Docs
EMD Value
₹15,200
Closing Date
6 Aug 2025, 4:30 pmClosed
Executive Engineer, Malda Mechanical Division, PHE
Office of the Executive Engineer, Malda Mechanical Division, PHE Dte. Doulatpur PHE complex, P.O. Maliha, Dist. Malda, PIN 732102
Supply delivery and installation of Full Bore Electromagnetic Flowmeter at Sankaritolaghat Intake pumping Station within Malda Arsenic area water supply scheme, dist Malda under Malda Mechanical Division, P.H.E. Dte.
2025_PHED_879877_1
WBPHED/EE/MLMD/NIeT_09 of 2025-2026
Open Tender
Electrical Work/ Equipment
30 days
Doulatpur PHE complex, P.O. Maliha, Dist. Malda
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,200
Yes
25 May 2026
21 Jul 2025
8 Aug 2025
21 Jul 2025
6 Aug 2025
21 Jul 2025
Amount
Supply and Delivery at site of Full Bore Electro- Magnetic Flow Meter of size DN 750 as per folowing specification given below. Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05cu.m /Pulse) With LCD 4 line backlit Display and configuration through Bluetooth, Calibration lab as per ISO 17025 , Accuracy: 0.5% , +/- 2mm/sec, Inbuilt Measuring, Reference, grounding & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner ,Supply: 24V DC or 230VAC. Make: Endress + Hauser/Other approved make.
Automatic Servo Voltage Stabilizer (1KVA) for Flow Meter along with Panel for Flow Transmitter Latest Digital Display and Microprocessor Controlled. • Copper variacs that are very long lasting & Durable. • Low voltage, high voltage cut out with automatic timer system inbuilt. • Output voltage accuracy of 1% tolerance and choice of 230V (for single phase). • Efficiency of over 98%, high precision output and 24 hours duty capable. • Maintenance free, • High speed of voltage correction up to 60 volts/ second. • Option of air-cooled Stabilizer.
Installation of the Flowmeter (as in Sl No. 1.00) along with servo voltage stabilizer (as in sl no. 2.00) at the specified position within the common delivery pipe line (DN 750) of pumping machineries by cutting pipe, prepairing edge & fittings & other acessories mending the damage pipeline including installation of display unit drawing of required power line by supplying & laying of required size of cable including testing commissioning all complete as per entire satisfaction of EIC.
Add GST @ 18%
Add Cess @ 1%
DEY ENTERPRISE (BID ID -6809554)
DAS CONSTRUCTION (BID ID -6811551)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid