Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC VILLAGE KOJINDA POST OFFICE MANDHANA TEHSIL NARNAUL DISTRICT MOHINDERGARH HARYANA 123001 | NARNAUL | MOHINDERGARH | HARYANA | 123001 | ₹2.6 L | L1 | Accepted-AOC l1 |
| 2 | L2₹2.7 LRejected-Finance 1350 B SHYAM LAL BAGH NEAR NAND CINEMA HISAR 125001 | HISAR | HARYANA | 125001 | ₹2.7 L | L2 | Rejected-Finance l2 |
| Sl No | Description | Qty | Unit | pawan Kumar L2 | Mange Ram L1 |
|---|---|---|---|---|---|
| 1.01 | [23.10]Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work. [Through Rate] | 40 | Each | 71 ₹2,840 | 86 ₹3,440 |
| 1.02 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate] | 12 | Each | 1,550 ₹18,600 | 1,450 ₹17,400 |
| 1.03 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] | 48 | Each | 170 ₹8,160 | 150 ₹7,200 |
| 1.04 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] | 12 | Each | 500 ₹6,000 | 500 ₹6,000 |
| 1.05 | [23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] | 950 | Metre | 100 ₹95,000 | 91 ₹86,450 |
| 1.06 | [23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] | 100 | Metre | 130 ₹13,000 | 117 ₹11,700 |
| 1.07 | [23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate] | 80 | Each | 150 ₹12,000 | 150 ₹12,000 |
| 1.08 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] | 80 | Each | 70 ₹5,600 | 43 ₹3,440 |
| 1.09 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] | 80 | Each | 110 ₹8,800 | 85 ₹6,800 |
| 1.10 | Supply of Wall fan 400 mm complete in all respect Make Orient/Crompton/Usha/Bajaj | 40 | Nos | 2,500 ₹1 L | 2,525 ₹1.0 L |
Tender Value
₹2.4 L
EMD Value
₹4,881
Closing Date
30 Apr 2026, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Construction of Govt. Medical College at Village Koriyawas in Distt. Mohindergarh. (Pdg. Additional E.I work only)
2026_HRY_517285_1
20264CFEEB3A 34BB 46A2 8E57 C5C4CEDB53D9668BAR
Open Tender
Civil Works
60 days
KORIAWAS
2 documents required · 2 mandatory
₹500
₹4,881
Yes
19 May 2026
24 Apr 2026
1 May 2026
24 Apr 2026
30 Apr 2026
24 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1.01 | [23.10]Erection of cabin fan complete with necessary earthling including carriage from PWD store to the site of work. [Through Rate] | - | Each | - | - | Each |
| 1.02 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate] | - | Each | - | - | Each |
| 1.03 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] | - | Each | - | - | Each |
| 1.04 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] | - | Each | - | - | Each |
| 1.05 | [23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] | - | Metre | - | - | Metre |
| 1.06 | [23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] | - | Metre | - | - | Metre |
| 1.07 | [23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate] | - | Each | - | - | Each |
| 1.08 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] | - | Each | - | - | Each |
| 1.09 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] | - | Each | - | - | Each |
| 1.1 | Supply of Wall fan 400 mm complete in all respect Make Orient/Crompton/Usha/Bajaj | - | Nos | - | - | Nos. |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_596157.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid