Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹32.2 L+₹97,178.54 (3.12%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹35.9 L+₹4.7 L (15.0%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | L4₹37.0 L+₹5.8 L (18.7%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹44.1 L
EMD Value
₹88,140
Closing Date
22 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAL
GE AF NAL BIKANER 334001
AS DESCRIBED IN BILL OF QUANTITIES
2025_MES_704845_1
GE (AF) NAL /T-01/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF NAL
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF NAL
₹88,140
Yes
3 Jul 2025
25 Apr 2025
24 May 2025
25 Apr 2025
22 May 2025
9 May 2025
25 Apr 2025 - 3 May 2025
Amount
Demolition of cement Concrete of any description and in any position including any type of roof treatment , PCC padding, lime concrete etc, complete all as specified and directed.
Dismantling of bricks(laid flat or on edge) or brick tiles in roof, floors, channels kerbs,aprons etc (each layes) laid bedded and pointed in any mortar, complete all as specified and directed.
Material and labour for providing cement concrete PCC (1:2:4) type B1 (20mm graded crushed stone aggregate) as in roof padding complete all as specified and directed.
M&L for APP based modified pre fabricated five layer 3 mm thick and weighing not less than 3.0 Kg/Sqm water proofing membrane reinforced with polyester non woven fabric mat with 150 gm/Sqm black finished with compatible primer conforming to IS 3488 @ 0.30 Lit/ Sqm and bonding material 85/25 bitumen 1.2 Kg/Sqm before laying membrane laid by torch application side overlap of 75 mm and over lap of 100 mm longtitudinally, At the junction of roof and parapet wall a grove of 20 x 20 mm shall be made at the ht of 100 mm and membrane shall be inserted and sealed with bituminious mastic joints/overlap shall ve saled with hot bitumen 85/25 all as directed by Engineer -in- charge.
Supply only integral water proofing compound ISI marked.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of grooves with cement mortAr 1:3
Material and labour for 15 mm thick plaster in CM 1:4 over concrete surfaces of roofs finished even and smooth using extra cement with WPC @ 3% by weight of cement, complete all as specified and as direceted. Note :- WPC will be measured and paid seperatey.
M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement and no pigments in floors, and cut and polished including 15mm thick screed bed in CM 1:6, complete all as specified and as directed.
M&L for Providing cement concrete 1:2:4 type B0 (12.5 mm graded crushed stone aggregate ) in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and as directed.
Surface excavation in soft/loose soil n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified & directed.
M&L for Soling with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber of thickness 150mm complete all as specified & directed.
M & L 75 mm thick PCC (1:4:8) ( 40 mm graded crushed stone aggregate) type D2 for sub base of floor complete all as specified and directed.
M & L for 65 mm thick M-35 grade precast concrete interlocking paver blocks using grey cement and pigment any shape and size conforming to IS 15658-2006 as directed laid dry in floors complete all as specified and directed.
M&L for Tibba sand cushioning 40mm thick below paver block, watering and consolidating, complete all as specified and directed.
Excavating in post holes(or similar holes)each n exc 0.5 cum ,getting out soft or loose soil ,returning ,filling in and ramming earth or broken rubble mixed with earth around ,in layers not exceeding 25 cm complete all as specified & directed.
Removing building materials etc to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified & directed.
M&L for steel work in tubular pipes as in vertical surfaces including special shaped washer such as column complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240,complete all as specified & directed.
M&L for rolled section as in main and cross beam , hip and jack rafters; purlins where connected to common rafters and running rails andm guides for sliding doors fixed with angle cleats or other connecting plates in Fe 290 Gde E-165 complete all as specified.
S&F for plates (plain or chequred ) channels ,square cut or notched (ordinary and counter sunk) forming holes , without any attachement in Fe 290 Gde E-165 complete all as specified.
M&L Mild steel screw bolt (machine made) dia 11 to 15 mm with hexagonal or square head at one end and screwed the other or screewd both ends each screwed end to be fitted with washers and one hexagonal nut length of bolt exc 5 cm but n. exc 10 cm long complete all as specified
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified & Directed
Demolition of brick or stone masonary built in cement mortar incl all quoins, arches, pillar etc. complete all as specified & directed.
M&L for brick work with sub class "B" brick straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6, complete all as specified & directed.
M&L Brick work with sub class ‘B’ bricks modular size bricks straight or curved on plan exceeding 6 Metre mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4,complete all as specified & directed.
M&L for Brickwork with subclass ‘B’ bricks, honeycomb brick walling straight or curved on plan n exc 6m mean radius built in CM 1:4, complete all as specified & directed.
M & L preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (40mm graded crushed stone aggregate)as infoundation filling and mass concrete, complete all as specified & directed.
Demolition of cement Concrete in Roof Or Chajja & beams or other suspended work specifically provided for complete all as specified and directed by Engineer In Charge.
M&L for reinforced cement concrete Nominal mix M-25 (using 20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like Complete all as specified and directed. Note:- reinforcement will pe measured and paid seperately.
Material & labour mild steel TMT bar 6 to 8 mm dia and cut to length bent to shape as required including cranking, bending etc and binding with and including MS wire annealed, not less than 0.9 mm dia, welded to existing bar before shotcreting complete all as specified and directed by Engineer In Charge.
Material & labour mild steel TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed by Engineer In Charge.
M&L for cement concrte type B0 (1:2:4) (using 20 mm graded crushed stone agregate) Slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for gunniting work to RCC work in column, flooring, side walls, beam, slab, etc by carefully chipping, removing exhisting loosel/damaged concrete cover etc, and cleaning all exhisting reinforcement bars with wire brush and applying alkaline rust converter primer on exhisting rebar and allowing it to react with rust for 06 hrs and form corrision resistant layer, then applying Zinc rich anti-corrisive protective coating on reinforcement bars as per manufactures instructions, and including fixing welded wire mesh fabric size 80mmX25 mm with 3mm dia, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 25 mm and making the surface even and fair and applying 15mm thick rendering in CM 1:4 on concrete surfaces, finishing the surfaces even and smooth, without using extra cement including necessary form work as required etc, and complete all as directed.
Taking up or down 15 mm dia steel tubing & connections including removal from site, complete all as specifief and as directed.
Taking up or down 20 mm dia steel tubing & connections including removal from site, complete all as specifief and as directed.
S & F 15mm bore of tube medium grade galvanized with all fittings & fixed complete to walls or laid in floors, complete all as specified and as directed.
S & F 20mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors, complete all as specified and as directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt from RCC / PVC tank capacity of tanks exc. 250 ltrs and up to 500 ltrs by emptying, drying, cleaning with chlorine/washing powder by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe, etc. and hoisting if required reconnecting and re-fixing in position.
Dismantling water tanks any type of capacity Exc 250 but n.exc 500 liters , complete all as specified and as directed.
S&F 500 litre capacity Rotational moulded polyethylene water storage tank, white colour, triple layers, conforming to IS, cylindrical vertical with closed top, hoisted and fixed in position complete all as specified and as directed.
Supply and fixed in repair 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and as directed.
S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore including necessary clumping complete all as specified and directed
S&F PVC (SWR) bends any radius 110mm bore, complete all as specified and as directed.
Taking down cement plaster any description on brick/concrete surfaces etc including raking out joints hacking for key, scrubing down with water etc complete all as specified and as directed.
M&L for plastering 15mm in cement mortar 1:4 on fair faces of brick / concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and labour for plastering 15 mm in cement mortar 1:6 on fair faces of brick or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L rendering 5 mm in cement mortar 1:3 on fair faces of brick /concrete surface of ceilling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over and including a coat of alkali resistant primer complete all as specified and directed.
M&L preparation of newly plastered surfaces of ceilling / chajja or similar suspended work and applying two coats of white wash complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls including all cornices, pilasters etc and applying two coats of acrylic exterior emulsion apex paint in camouflage pattern of approved tint / shade(s) over and including a coat of water based primer complete all as specified and directed.
Materail and Labour for preparation of plastered or unplastered old surfaces of walls and two coat of oil bound distemper on walls all as specified and as directed by Engr-in-Charge.
Materail and Labour for preparation of plastered or unplastered old surfaces of ceiling and two coat of white wash on ceiling all as specified and as directed b.
M&L for 3 mm thick , wall care putty on walls, in two coat and after complete drying rubbing gently with waterproof emery paper greater than 500, and complete all as specified and as directed.
All as per Item No. 58 above but on ceilng
M&L for preparation of old surfaces using necessary filling compound of putty to obtain smooth regular/even finish using sand paper and applying two coat of exterior emulsion paint (Apex from asian paint or equivalent in shalimar/Berger paints) on wall at upto 7.5 m height and any position complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removal complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7-8 mm thick, (square/rectangular) area of each tile exc. 0.11 but n.exc. 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in CM 1:6 complete.
M & L for joint free glazed coloured ceramic coloured tiles of 300mm x 450mm x 7mm thick on vertical surface of walls set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles, over and including 10mm thick rendering in CM 1:4, all as specified and directed by engr-in charge.
M & L for coluored Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed CM 1:6, complete all as specified and as directed.
M & l for Cutting chases, pining in making good to facings where required & pointing in cement mortar1:3 to ends etc or edges of landings, steps cills,sunshades, shelves,lintels,etc and cutting chases for concealed water tubing and making good,cutting n.exc. 10cm girth in brick walls all as directed.
Supply and fixing in repairs fancy type angle stop valve, chromium plated,screwed down, high pressure with crutch or butterfly handle screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed.
Supply and fixing in repairs long body Bib taps,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for 15mm bore pipe complete all as specified and directed.
Supply and fixing 15mm dia PVC connection with brass nut, of length 450mm,fixed as in repairs, complete all as specified and directed.
Supply and fixing as in repair PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC bend for required squat pattern etc, set with concrete and making good to floor, fixed as in repairs complete all as specified & directed.
Supply & fixing as in repair vitreous china wash hand basin, white flat back, size 300mm x 450mm including pillar tap 15mm dia chromium plated with capstan head with long screwed shanks and fly nuts, and brass chromium plated waste coupling 32mm dia complete all as specified & directed.
S&F as in repairs 100 mm dia mild steel chromium plated grating with or without waste pipe hole as per requirement complete all as specified and directed.
S&F in repair tubular towel Rail 20 mm dia of brass chromium plated complete all as specified and directed.
S&F in repair soap dish vitreous China white, approximate size 160x 160x90mm , any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed
Taking down chowkhats with shutter without taking off shutters from the frames (area n. exc. 1.50 sqm each) incl making good the disturbed surfaces complete all as specified & directed.
Supplying & fixing in opening solid PVC door frame of size 50mm x 47mm made out 5mm plain colour PVC sheets re-inforced with MS tube with Plain colour PVC sheet & edges will be painted to match with printed sheet, complete all as specified and directed.
M & L for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified & directed.
Supply and fixing Mild steel butt hinges medium weight , clod rolled, 75mm, ISI marked, complete all as specified & directed.
Material & Labour barrel tower bolts aluminium anodised extruded section of size 100 mm complete all as specified & directed.
Supply and fixing aluminium fabricated type extruded handles of size 100mm complete all as specified & directed.
S&F Anodised aluminium frame for ,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed by Engineer In Charge.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1no.) complete all as specified complete all as specified and directed.
S&F Galvanised steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified & directed.
S&F Sheet glass,ordinary quality 4mm thick and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as speccified & directed.
Taking down chowkhats with shutter without taking off shutters from the frames (area exc. 1.50 sqm bUt N exceeding 4.00 Sqm each) incl making good the disturbed surfaces complete all as specified & directed.
Supplying & fixing in opening 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified &directed
Material and labour for pressed steel frames for doors of size 105 x 60 mm for doors with one or more rebate including necessary fixing lugs, hinges, lock, strike plates of 50 x 3mm welded with frame and making arrangement for fixing of door spring etc complete all as specified and as directed.
Material & Labour barrel tower bolts aluminium anodised extruded section of size 200 mm complete all as specified & directed.
Supply and fixing aluminium fabricated type extruded handles of size 150mm complete all as specified & directed.
Supply and fixing 200 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing cleap of sheet, cast or extruded sections, bolt not less then 12mm dia with and including a minimum of 6 bolt and nuts ,fixed on plate or staple plate complete all as specified & directed.
Material and Labour for preparation of new surfaces of wood & wood based surface of any description not otherwise described, over 10 cm width & girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old painted wood or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified & directed.
M&L preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) incl for angle iron,fencing post,Rolling shutter etc. complete all as specified & directed.
Demolition of plain cement concrete in ground floor and paving n.exc. 15 cm thick below or above ground level complete all as specified & directed.
Material & Labour for 75mm thick cement concrete type D-2,1:4:8 (40mm graded crushed stone aggregate) as in sub base complete all as specified & directed.
M&L PCC (1:3:6) type C-2, (using 40mm graded stone aggregate) as in plinth protection 75mm thick laid in bays and surfaces finished even & smooth without using extra cement complete all as specified .
M&L chequered cement concrete tiles 20cm x 20cm x 25 mm thick , set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over 15 mm thick screed bed in CM 1:6 over and including 100 mm thick PCC 1:4:8 Type D-2(40mm graded aggregate) all as specified and directed by engr-in-charge.
Excavation in soft/loose soil in trenches not exceeding 1.5 metre wide / manholes area n exc 10sqm on plan and depth not exceeding 1.5 metre and getting out complete all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator)/ means over areas (exc 30 cm in depth, 1.5 m in width as well as 10 sqm on plan ) including getting out in any kind of soil and disposal of excavated earth lead upto 50 m and lift upto 1.5 m , as directed by Engr-in-Charge.
All as per item No 100 but depth exc 1.50 mtr but n exc 3.00 mtr in depth and getting out in any kind of soil complete all as specified and directed.
All as per item No 100 but depth exc 1.50 mtr but n exc 4.50 mtr in depth and getting out in any kind of soil complete all as specified and directed.
Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removing excavated material to a distance exc. 50 metre but not exceeding 100 metre and depositing where directed at a level not exceeding 1.5 Metre above starting point, complete all as specified and directed.
Demolition and breaking up drain pipes of150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L Concrete bed to drain pipe 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate, complete all as specified and directed.
Supply, laying and jointing reinforced concrete pipes, class NP-2 with collars, 150mm Internal dia in trenches, and tested including all necessary extra joints, waste, and cutting etc. complete all as specified and directed. Note : Excavation and earthwork shall be measured and paid for separately
M&L Cutting into existing manhole for connecting into new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section), in cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for 150 mm bore SGSW / RCC pipe, complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc, complete all as specified and directed.
Desilting of septic tank for 50 users size including cleaning and taking out mud/ sludge, scum, silt (both organic and inorganic nature) from septic tanks by mechanical means of any depth, in foul conditions and confined places, getting out and removing the Sludge / Sludge water disposed off in closed container at authorized dumping site declared by local administration outside MD land as directed by Engineer-in-Charge complete all as specified and directed. Note:- Net contents of sludge shall be measured at the time of removal and paid. Quoted rate of tenderer is deemed to be inclusive of dewatering as required and nothing extra shall be admissible to the contractor on this account.
Dewatering of Septic tank/Soakage Well cleaning and taking out effulent water from soakage well by mechanical means of any depth, in foul conditions and confined places, getting out and removing the effulent water and disposed off in closed container (tank capacity 5000 Ltr) at authorized dumping site declared by local administration outside MD land as directed by Engineer-in-Charge complete all as specified and directed.
Material and labour cleaning & clearing manholes by taking off manhole covers and re-fixing the same after cleaning of any description, underground upto 1 metre depth by removing any type of blockage including de-silting and de-chocking and flushing after cleaning, clearing of manholes. Sludge/ sludge water shall be disposed off in closed container at authorized dumping site declared by local administration outside MoD land as directed by Engineer-in-Charge, upto 150mm dia sewage lines complete all as specified and directed.
Demolition of reinforced cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately), complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including necessary from work as in coping, benching of manhole, slightly rounded or chamfered, complete all as specified and directed.
M&L for Precast RCC 1:2:4 type B-1( using 20 mm graded crushed stone aggregate) as in manhole covers set in cement mortar1:4 including necessary form work, complete all as specified and directed.Reinfocement shall be measured and paid seperatly.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M & L for Point wiring on concealed conduit with 1.5 Sq mm copper conductor single core PVC insulated unsheathed 1100 V grade multistranded drawn into and including rigid PVC conduit with accessories of suitable dia medium grade concealed in walls/floors and pressed steel terminal boxes MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated sheet including one running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified.
One light point controlled by one, one way switch 6 A, SP
One ceiling fan/exhaust fan point controlled by one, one way switch
One 3 point 6 Amps switch socket outlet point controlled by one switch on the same board.
One 3 pin 6 Amps switch socket outlet point controlled by one switch on independent board.
All as per item No 3 here-in-before but using 4.0 Sq mm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.0 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S&F modular switch 1way 6A, 1 module all as specified and directed
S&F modular socket, 6A - 2/3 pin combined 2 module, flush type all as specified and directed
S&F modular switch 1way 6/16A, 1 module all as specified and directed
S&F modular socket, 6A/16A - 2/3 pin combined 2 module, flush type all as specified and directed
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
S&F modular metal flush box 6 module all as specified and directed
All as per item No.126 hereinbefore but 4 module
All as per item No.126 hereinbefore but 3 module
All as per item No.126 hereinbefore but 2 module
S & F modular white cover plate with frame 6 module all as specified and directed
All as per item No.130 hereinbefore but 4 module
All as per item No.130 hereinbefore but 3 module
All as per item No.130 hereinbefore but 2 module
S&F of Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed.
S&F LED lamp 9W complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
S&F modular fan step regulator, 2 module all as specified and directed.
Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed.
Supply and Fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed.
M & L for Submain wiring with two single core 6 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including concealed rigid PVC conduit of suitable dia, conduit fittings and accessories concealed in wall/floor with one run of 6 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
M & L for Submain wiring with two single core 4 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including concealed rigid PVC conduit of suitable dia, conduit fittings and accessories concealed in wall/floor with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Supply and fixing sheet Metal enclosure double door type for DB’s 240 Volts Single Pole and Neutral 12 way with 200 Amps rated bus bar complete all as specified and as directed
Supply and fixing MCB SPN 40-63 Amps , 240 volt, 10 KA, complete all as specified and as directed
Supply and fixing MCB single pole 6 to 32 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure Line load distribution board TPN 4 Way with 200 Amps rated bus bar 415 volts, with MCCB TPN as incoming and 12 out going SP MCB's double door with suitable locking arrangement complete al as specified .
Supply & Fix MCCB 4P suitable for fixing on 4 way TPN DB of capacity 63 Amps complete all as specified.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, complete all as specified.
Supply and fixing Energy saving and environmental friendly long life 35W LED bldg security light having IP66 protection complete with all accessories incl three run of 1.5 Sqmm Copper conductor cable from security light to ceiling rose, complete all as specified.
Supply and fixing GI pipe bracket made of 40 mm bore light grade pipe made to shape of overall length of 1.2 mtr for fixing of security light fitting including MS clamps , nuts & bolts of required size complete
Supply & Laying XLPE insulated armoured, heavy duty, electric cable with aluminium conductors of size 25 sqmm 4 core 1100 volts laid in floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified.
Excavation in trenches not exceeding 1.5m and not exceeding 1.5m in depth for laying of electric cable and getting out in hard and dense soil, complete all as specified and as directed by the Engr-in-Charge.
Returning, filling in excavated soil, including levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by the Engr-in-Charge.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engr-in-Charge.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
M&L for sand cushioning using river washed and screened, dry sand in two layers, first layer of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ ducts including consolidation of each layers complete all as specified and directed. Note:- Punned thickness shall be measured for payment.
M & L for Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead 4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earth electrode to DBs/main switch incl provn of concrete pit in PCC , GI pipe light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4mm size and protection pipe of 15mm bore GI light grade.
JAMUNA CONSTRUCTION AND GENERAL ORDER SUPPLIER (BID ID -3297925)
OM SAI RAM CONSTRUCTION (BID ID -3297893)
J AND K CONSTRUCTION CO (BID ID -3297432)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .