Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-Finance | ₹14.0 L | L1 | Accepted-Finance Accepted being lowest quoted rate |
| 2 | L2₹14.0 LRejected-Finance | ₹14.0 L | L2 | Rejected-Finance Rejected being other than lowest quoted rate |
| 3 | L3₹16.1 LRejected-Finance | ₹16.1 L | L3 | Rejected-Finance Rejected being other than lowest quoted rate |
| 4 | L4₹18.9 LRejected-Finance | ₹18.9 L | L4 | Rejected-Finance Rejected being other than lowest quoted rate |
| Rank | Bidder | Total Amount |
|---|---|---|
| L2 | vedant engineering enterprises Bid ID 3604391 | ₹14,01,111 |
| L3 | Mahindra Electric Stores Bid ID 3607505 | ₹16,09,886 |
| L4 | M/s. Shahabad Enterprises Bid ID 3606993 | ₹18,90,175 |
| L1 | M/s Swaroop Enterprises Bid ID 3607610 | ₹13,99,655 |
| Sl No | Description | Qty | Unit | vedant engineering enterprises L2 | Mahindra Electric Stores L3 | M/s. Shahabad Enterprises L4 | M/s Swaroop Enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Split air conditioning unit 1.50 TR (INVERTER TYPE) capacity with HD filter complete with cordless remote control, minimum 5 star labelled,latest energy efficient model eco friendly refrigerant gas,4500 Kcal/Hr,50 Hz,240 volts,air cooled condenser with all accessories varied speed including fixing the outdoor unit on outdoor wall mounting brackets or on stand on terrace as per site requirement and fixing of room(high wall) unit on wall with necessary wall cutting/making hole(core cutting) to pass the refrigerant pipes,drain pipes,cables etc and making good to match with existing finishing complete,providing and making indoor to outdoor communication cable & copper tube connection upto a distance of 3 mtrs as provided by OEM, power cablling (Max 3.0 mtrs from enclosure) to unit, first charging of refrigerant gas including cordless remote, providing drain piping of suitable size from unit upto ground level with proper clamping to wall and covering both drain and rerfrigerant tubes, communication cables through casing capping of minimum size 100X50 mm or as per site requirement inside the room complete all as specified and directed.
Make: LG, Daikin, Hitachi, Blue Star | 13 | Each | 49,500 ₹6,43,500 | 45,000 ₹5,85,000 | 57,000 ₹7,41,000 | 47,750 ₹6,20,750 |
| 1.10Note for Sl item No 1.00:- 1) The ACs are to be installed in Server rooms equipped with many sophisticated electronic equipments. The rooms are located in different units of MIC&S. Shutdown/ work time permission shall be obtained from the office before starting the work. The contractor shall required to pause the work and resume as per site requirements and complete shut down of the equipments will not be permitted. 2) Due care shall be ensured during the installation work. The wall and floor to be covered with protective sheets to prevent scratches and damages. Dust and debris to be removed properly with vacuum cleaner after completion of work. After work, wall/ panels to be repaired/ replaced and to be match with existing surfaces. 3) The entire work shall be carried out in presence of a qualified supervisor.The Contractor shall visit the site before bidding to check and understand the site feasibilty. No claim shall be entertained on this account after quoting of the tender. | |||||||
| 2.00 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA suitable for inverter type AC complete all as specified and as directed.
Makes :- Automatic electrical (AE) / Vinitec / APLAB / V Guard / Volina | 13 | Each | 3,100 ₹40,300 | 3,000 ₹39,000 | 3,200 ₹41,600 | 1,500 ₹19,500 |
| 3.00 | S&F Copper tubes (size 1/4 inch for liquid line and 1/2 inch for suction line or as per OEM recommendation) including nitrile rubber insulation suitable for 1.5 Ton inverter Split AC including necessary fittings/clamps for fixing on wall and connection to outdoor/indoor units complete leak test as per OEM and all as directed.
Note: Suction pipe, discharge pipe with nitrile rubber insulation together shall be measured as one unit. | 19 | RM | 750 ₹14,250 | 1,250 ₹23,750 | 300 ₹5,700 | 350 ₹6,650 |
| 4.00 | Taking down carefully by disconnecting and unscrewing from boards/outlet boxes,electric meter from any location and sizes and depositing to MES store yard,maintaining proper records,reading of OLD meters,ser no, date and time of removal and submitted to AGE E/M office complete all as specified and directed. | 150 | Each | 50 ₹7,500 | 10 ₹1,500 | 1 ₹150 | 100 ₹15,000 |
| 5.00 | M & L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed.
NOTE: 1.Proper colour coding shall adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)
2.Three runs of 6 sq.mm cable and one run of PVC casing & caping shall be measured as one unit.
3.The item has been considered for connecting submain wring from MCB to meter/as per site reqiurements and direction of Engr-in-charge. | 92 | RM | 420 ₹38,640 | 485 ₹44,620 | 100 ₹9,200 | 400 ₹36,800 |
| 6.00 | S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. | 7 | Each | 180 ₹1,260 | 165 ₹1,155 | 150 ₹1,050 | 125 ₹875 |
| 7.00 | S&F in repairs, MCB SPN, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. | 28 | Each | 550 ₹15,400 | 650 ₹18,200 | 800 ₹22,400 | 400 ₹11,200 |
| 8.00 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), Tripple pole and neutral, 415 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. | 7 | Each | 1,200 ₹8,400 | 3,000 ₹21,000 | 4,000 ₹28,000 | 2,800 ₹19,600 |
| 9.00 | S&F in repairs ISOLATOR TPN, AC 415 V, 63 amps, 10 KA capacity ,'C' series, making connection with suitabl size of copper lugs etc complete all as specified and as directed. | 7 | Each | 1,550 ₹10,850 | 2,500 ₹17,500 | 1,250 ₹8,750 | 1,250 ₹8,750 |
Updated dates
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
18 May 2026, 6:00 pmClosed
Shri Milind Mulik, (AE QS and C)
Military Engineer Services, Garrison Engineer (South) Ahilyanagar - 414002
CERTAIN E/M SANCTIONED WORKS AT MIC and S UNDER GE(S) AHILYANAGAR
2026_MES_761046_1
8329/E8
Open Tender
Electrical and Maintenance Works
120 days
Ahilyanagar
Class E Cat b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahilyanagar
₹34,000
Yes
22 Jun 2026
20 Apr 2026
20 May 2026
20 Apr 2026
18 May 2026
4 May 2026
20 Apr 2026 - 27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Supply, installation, testing and commissioning of Split air conditioning unit 1.50 TR (INVERTER TYPE) capacity with HD filter complete with cordless remote control, minimum 5 star labelled,latest energy efficient model eco friendly refrigerant gas,4500 Kcal/Hr,50 Hz,240 volts,air cooled condenser with all accessories varied speed including fixing the outdoor unit on outdoor wall mounting brackets or on stand on terrace as per site requirement and fixing of room(high wall) unit on wall with necessary wall cutting/making hole(core cutting) to pass the refrigerant pipes,drain pipes,cables etc and making good to match with existing finishing complete,providing and making indoor to outdoor communication cable & copper tube connection upto a distance of 3 mtrs as provided by OEM, power cablling (Max 3.0 mtrs from enclosure) to unit, first charging of refrigerant gas including cordless remote, providing drain piping of suitable size from unit upto ground level with proper clamping to wall and covering both drain and rerfrigerant tubes, communication cables through casing capping of minimum size 100X50 mm or as per site requirement inside the room complete all as specified and directed.
Make: LG, Daikin, Hitachi, Blue Star | - | Each | - | - |
| 0.0 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA suitable for inverter type AC complete all as specified and as directed.
Makes :- Automatic electrical (AE) / Vinitec / APLAB / V Guard / Volina | - | Each | - | - |
| 0.0 | S&F Copper tubes (size 1/4 inch for liquid line and 1/2 inch for suction line or as per OEM recommendation) including nitrile rubber insulation suitable for 1.5 Ton inverter Split AC including necessary fittings/clamps for fixing on wall and connection to outdoor/indoor units complete leak test as per OEM and all as directed.
Note: Suction pipe, discharge pipe with nitrile rubber insulation together shall be measured as one unit. | - | RM | - | - |
| 0.0 | Taking down carefully by disconnecting and unscrewing from boards/outlet boxes,electric meter from any location and sizes and depositing to MES store yard,maintaining proper records,reading of OLD meters,ser no, date and time of removal and submitted to AGE E/M office complete all as specified and directed. | - | Each | - | - |
| 0.0 | M & L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed.
NOTE: 1.Proper colour coding shall adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)
2.Three runs of 6 sq.mm cable and one run of PVC casing & caping shall be measured as one unit.
3.The item has been considered for connecting submain wring from MCB to meter/as per site reqiurements and direction of Engr-in-charge. | - | RM | - | - |
| 0.0 | S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. | - | Each | - | - |
| 0.0 | S&F in repairs, MCB SPN, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'C' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. | - | Each | - | - |
| 0.0 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), Tripple pole and neutral, 415 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. | - | Each | - | - |
| 0.0 | S&F in repairs ISOLATOR TPN, AC 415 V, 63 amps, 10 KA capacity ,'C' series, making connection with suitabl size of copper lugs etc complete all as specified and as directed. | - | Each | - | - |
| 0.0 | Supply and fix electronic energy meters tamper proof with LCD display and polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, PF, voltage and KWH complete all as specified and as directed.
Make: L&T Model EM101+ Cat no:WM101BC7DDH or equivalent model of makes specified. | - | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_852480.xls
BOQ • 0.29 MB
8329Tenderdocuments.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid