Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical not qualified |
Tender Value
₹33.5 L
EMD Value
₹67,000
Closing Date
30 Dec 2024, 2:00 pmClosed
Executive Engineer Electric division JPDCL batote
Office of Executive Engineer ED Batote
SUPPLYERECTION TESTING COMMISSIONING FOR CREATION OF 3 x100 KVA SUBSTATIONS 2x63 KVA SUBSTATIONS and 5X25 KVA SUBSTATIONS AT VARIOUS LOCATIONS OF DISTT RAMBAN AGAINST UT CAPEX BUDGET 202425 UNDER THE JURISDICTION OF ED BATOTE on Turnkey Basis
2024_PDD_268289_1
e NIT 35 of 2024-25
Open Tender
Electrical Works
Turn-key
60 days
Ramban District batote
As per SBD
4 documents required · 4 mandatory
₹1,000
Yes
Executive Engineer Electric division JPDCL batote
₹67,000
Yes
3 Feb 2025
18 Dec 2024
31 Dec 2024
18 Dec 2024
30 Dec 2024
18 Dec 2024
18 Dec 2024 - 27 Dec 2024
Amount
Creation of 100 KVA sub-station(Pole Mount) at WANIPORA GUGTHAL DOLIGAM LOWER
11/0.433KV, 3-phase Copper wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of Sub-station
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
32/63 amps TPN Switch Disconnectotr Fuse Set
LT Distribution Box with 100 Amps 3 Pole outdoor MCCB
Prodigy Meter(Secure Ltd.)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Creation of 1x63 KVA sub-station(Pole Mount) at DORITHAL FAGOO PANCHAYAT UPPER-B
11/0.433 KV, 1X 63 KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
120sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x63 KVA sub-station(Pole Mount) at KHOJA MOHALLA PYT. DOLIGAM
11/0.433 KV, 1X 63 KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
120sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x25KVA sub-station(Pole Mount) at THATWANPORA MALWAT Chanjloo
11/0.433 KV, 1X 25KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
70sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x25KVA sub-station(Pole Mount) at DRAMAN Sheropora
11/0.433 KV, 1X 25KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
70sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x25KVA sub-station(Pole Mount) at NAI BASTI Ward No. 06 MIR MOHALLA Near Shopping Complex
11/0.433 KV, 1X 25KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
70sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x100KVA sub-station(Pole Mount) at MASJID MOHALLA KRALCHIHAL
11/0.433 KV, 1X 100KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
185sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x25KVA sub-station(Pole Mount) at BASTI TAKERR
11/0.433 KV, 1X 25KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
70sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x25KVA sub-station(Pole Mount) at JANWAL Mohalla SHADANI
11/0.433 KV, 1X 25KVA 3 Phase Distribution Transformer wi Bi-mettalic Terminal Connectors Energy Level-2 (Alumminium wound)
Gapless Surge Arrestor, 9 KV , 10 KA, LA with (polymer/procelin) housing
11 KV GO, AB Switch 3-Phase, 3 Pole, 200 Amp, vertical type
11 kV Horn Gap Fuse Set 3 Phase 200 A
70sqmm Single core Cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr Long Pole ( ST-410 SP33)
11 KV Polymeric composite Disc Insulator 12 KV, min failing load 45 kN, Lighting Impulse 75 kV Positive and 80 kV Negative, creepage distance 320 mm.
GI Channel/Angle/Flat of sizes including clamps
Galvanized nuts and Bolts
32/63 amps TPN Switch Disconnectotr Fuse Set
Earthing of Sub-Station- Excavation of Earth pit of Dia 60 mm & depth 3000 mm, installation of earthing pipe of 40 mm Normal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239, GI Strip for neutral earthing of size 75 mm x 100mm & 50 mm x 6 mm for connection of transformer body, GO set & lightening Arrestor as per IS 2629/85, GI nuts & Chamber made of Briks Maonary with RCC Slab cover.
LT Distribution Box for DTR with 100 Amps 3 Pole outdoor MCCB
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
Prodigy Meter(Secure Ltd.)
Creation of 1x100KVA Pole Mounted Substation at LOWER Ganga CHANPORA PYT. Chacknarwah
11/0.433KV, 3-phase Copper wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of Sub-station
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
32/63 amps TPN Switch Disconnectotr Fuse Set
LT Distribution Box with 100 Amps 3 Pole outdoor MCCB
Prodigy Meter(Secure Ltd.)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
GIRI ELECTRICAL & SONS (BID ID -2294882)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .