| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 Cr+₹157.21 (<0.01%)Rejected-AOC | ₹1.8 Cr+₹157.21 (<0.01%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.8 Cr+₹7,800 (0.04%)Rejected-AOC C O LT MAAHANTA NARZARY W NO 5 TENGAPARA P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹1.8 Cr+₹7,800 (0.04%) | L3 | Rejected-AOC L3 |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
22 Nov 2021, 1:30 pmClosed
The Addl. Chief Engineer cum Director, PWD,BTC
O/o the Addl. Chief Engineer cum Director, PWD,BTC,Kokrajhar
Construction of New Building (RCC G - 1) at (Barghuli) Niz Kaurbaha BPHC in Baksa District. (TN_39_6)
2021_BTC_23359_1
No. ACE- 106/PWD/IFB/2021-22/13
Open Tender
Civil Works - Building
Item Rate
365 days
Baksa
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,300
The Principal Secretary, BTC, Kokrajhar
₹3.5 L
Yes
1 Dec 2021
11 Nov 2021
22 Nov 2021
11 Nov 2021
22 Nov 2021
11 Nov 2021
11 Nov 2021 - 22 Nov 2021
Amount
(A) Construction of New Building (RCC G+1): Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and remming of bottoms, lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed, wihin a lead of 50m. 2.8.1 All kinds of soil.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12mm mud mortar, including filling joints Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:3:6 (1 cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size)
Steel reinforcement for RCC work including straightening cutting, binding, placing in position and binding all complete upto plinth level. 5.22.6 Thermo_Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for RCC work including straightening cutting, binding, placing in position and binding all complete upto plinth level. 5.22A.6 Thermo_Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for RCC work including straightening cutting, binding, placing in position and binding all complete upto plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.6 Columns, pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.5 Lintels, beams, plinth beams, girdes, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.3 Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.7 Stairs, (excluding landings) except spiral-staircase
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level 1:1.5:3 (1 cement; 1.5 coarse sand (zone-III): 3 graded stone 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttesses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finished and reinforcement: 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm ominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chah=jjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor level, excluding the cost of centering, shuttering, finished and reinforcement. 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm ominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
Half brick masonary with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2 Cement mortar 1:4 (1 cement: 4 coarse sand)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commerical mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle thereshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed. by Engineer in-charge 10.14.2 Profile C 10.14.2.1 Fixing with adjustable lugs with split end tail to each jamb.
Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part-I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1.35 mm thick including ISI marked stainless steel butt hinges with necessary screws
10.15 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/L-Type sections, made of 1.60mm thick M.S. Sheet, joints mittred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.15.1 Fixing with 15 x 3 mm lugs 10 cm long embedded in cement concrete block 15 x 10 x 10 cm of CC 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 10.30.1.4.0mm thick glass panes.
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance + 1mm), with wall thickness 2.0 mm (+0.2mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1mm (+0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacture's specification and direction of Engineein-charge. 9.117.1 Extruded sections profile size 48 x 40 mm
Providing and fixing to existing door frames. 9.118.1 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (+0.2mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the cornersv by means of M.S.galvanished/plastic brackets of size 75x220mm having wall thickness 1.0mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20mm and 1 mm (+ 0.1mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2mm (+0.2mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620mm, having over all thickness of 20mm and 1 mm (0.1mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanised M.S. road and fastended with nuts and washers, complete as per manufacture's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
12mm cement plaster of Mix 13.4.2.16 (1 cement: 6 coarse sand)
15mm cement plaster on rough side of single or half brick wall of mix: 13.5.2.1.6 (1 cement: 6 coarse sand)
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. Flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc.complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with cement cement and matching pigments etc., complete. 11.41.2 Size of Tile 600 x 600 mm
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacture) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation, as approved by Engineer-in-charge) 0.50 mm (60.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surface, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing M.S. Fan clamp type 1 or II of 16mm dia M.S. Bar, bent to shape with hooked ends in RCC slabs or beams during laying, including paonting the exposed portion of loop, all as per standard design complete.
Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 13.9.1 12mm cement plaster
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-iii) : 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even sand smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer.
13.44 Finishing walls with water proofing cement paint of required shade: 13.44.1 New work (two or more coats applied @ 3.84kg/10 sqm)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc. complete. 13.52.1 On steel work.
Providing and fixing bright finished brass 100mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 9.74.2 200x10mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete. 9.75.2. 250x16x5 mm
(B) Sanitary Installation: Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 PCC Baffle wall, inlet and outlet etc are providing at suitable points complete as directed. (vii) 50 Users
Providing and fixing white vitreous china pedestal type water closet (European type W.C. Pan) with seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with C.I. Brackets, 15 mm C.P. Brass pillar taps, 32mm C.P. Brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630 x 450 mm with a pair of 15mm C.P. brass pillar taps each 3087.70
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: 17.32.2 Rectangular shape 453x357 mm
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.1 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170 gms
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45cm dry brick comb shaft with bricks and S.W. Drain pipe 100 mm diametre, 1.8 m long complete as per standard design 19.32.1 with common burnt clay F.P.S (non modular) bricks of class designation 7.5
(C) Internal Water Supply works: Boring with 100mm diametre casing pipe for hand pump/tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/tube well is lowered and tested: 18.42.3 Beyond 12m and up to 18m depth.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. External work 18.9.7 62.50 mm nominal inner dia pipes.
Providing and placing in position filters of 40mm diameter G.I pipe with brass strainer of approved quality, metre 768.55
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing Chlorinated Polyviny Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cemet and testing of joints complete as per direction of Engineer in Charge. Internal Work- Exposed on wall 18.7.5. 40 mm nominal outlet dia pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at This includes jointing of pipes & fittings with one step m spacing, This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making B66 od the same including testing of joints compkete as per direction of Engineer in Charge Concealed work, including cutting chases nd mm nommaking good the walls etc. 18.8.3 25 mm nominal outler dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at This includes jointing of pipes & fittings with one step m spacing, This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making B66 od the same including testing of joints compkete as per direction of Engineer in Charge Concealed work, including cutting chases nd mm nommaking good the walls etc. 18.8.1 15 mm nominal outer dia pipes
Providing and fixing CP brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931 18.52.1 15 mm nominal bore
Providing and fixing CP brass sbib cock of approved quality conforming to IS: 8931 18.49.1 15 mm nominal bore
(D) Land Development with Earth Filling: Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
(E) Internal Electrification: Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.1 1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.2 3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.4 6 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.5 8 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.6 12 Module
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.3 15/16 A switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.5 6 pin 15/16 A socket outlet
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.1 2 x 1.5 sq.mm+1x1.5 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.2 2 x 2.5 sq.mm+1 x 2.5 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.3 2 x 4 sq.mm+1 x 4 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.4 2 x 6 sq.mm+1 x 6 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.10 4 x 10 sq.mm+ 2 x 6 sq.mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paonted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.4 16 way, Double door.
Supplying ad fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive loard of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.2 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2 63A
Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of.............insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing two module stepped type electronic
Supplying and fixing brass batten/angle holder including connection etc. as required.
Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required.
Installation, testing, commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/wall, including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Earthing with G.I. Earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Providing and laying warth connection from earth electrode with 6 SWG dia G.I. Wire in 15mm dia G.I. Pipe from earth electrode including connection with G.I. Thimble excavation and re-filling as required.
Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.1 100A, 16 KA, TPMCCB
Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.14 125A, 36 KA, FPMCCB
Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.17 250A, 50 KA, FPMCCB
Supplying, fiting & fixing of LED tube light aluminium Extruded smart Bright Batten light fitting (4ft) Model No. BN021C LED22S PSU CW GR (Philips make) as required and as directed by the department.
Supplying fitting & fixing of LED Bulb (7W/9W/12W) non-dimmable in the existing batten/angle holder as required and as directed by the department (Philips or eqvt. Make)
Supplying, fitting & fixing of exhaust fan 230mm sweep Model No. Ventil Air-DS (Havells make) as required and as directed by the department.
Supplying including installation, testing and commissioning of Hi-Wall Non ductable type of 1.50 Ton capacity having proper cooling capacity single phase 3 STAR MODEL Split type inverter Air Conditioner Machine complete with corded Remote, copper pipe connection between indoor & outdoor Unit, electrical connection etc (Voltas Make) Model No. Voltas SAC 183V CZR
Supplying with fitting and fixing of 4 KVA Voltage stabilizer including making necessary connection as approved, specified and directed by the deptt. (Vee-Dee make) Model no.VD-40908
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch including making necessary connection as per direction of department. (Legrand Make) Model no.6734-66
Supplying, including, installation, ommissioning of vermin and dust proof totaly enclosed, phosphatised powder painted cubical out door type double door, floor mounting compartmentalize panel board of size 900 mm x 12mm x 400mm made of 16 SWG 1.66 m thick C.R. sheet and 35mm x 35mm x 5mm size angle having 4 nos.legs at the bottom and C.R. sheet roofing on the top. The panel board is to be erected in 1:3:6 PCC foundation including excavation of trench and brick soling etc.complete neatly wiring done with provision for 1) 2 nos. 400 A 4 pole 415V MCCB,2) 2 nos. 400 A SPREADER TERMINAL
Supplying, fitting & fixing of LED Decorative post TOP lantern with IP65 protection (Crompton make) fitted on existing GI pipe with all accessories as required and as directed by the department.
Supplying installation testing and commissioning of pressure dia cast powder coated aluminium alloy housing forested PC diffuser OP65/IP66 protection of street light including connection with 2.5 sq.,mm 3 core PVC insulated rounded copper conductor Model no-BRP 409 LED 065 CW HE MR FG S1 PSU GR (Philips make) as required and as directed by the deptt.
Supplying including installation, testing and commissioning of Air/Water Cooled Disel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. (la mounted on a 1) M.S. Fabricated base frame., 2) M.S. fuel tank of required capacity., 3) Residual Silencer., 4) AMF Control.5) Suitable batteries with lead., 5) First fill of lube oil., 6) Acoustic Enclosure complete with all accessories as specfiied and directed by the department conforming to IS comprising the Technical specification. as per manufacturer. (RANGE FROM 5 KVA TO 625 KV. Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer or equivalent alternator. 25 KVA Water Cooled Disel Generator Set.
Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance strip, Galvanised for cables up to 2 x 10 sq.mm.3x10 sq.mm, 4x6 mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part-1) 1988 armoured U.G. cable laid in ground/partially in air (as required for termination up as specified and directed by the deptt. (RR Kabel/Havells/Polycab make or equivalent). 4.00 sq.mm 2 core (A2XWY A2XFY) armoured U.G. cable.
Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sqmm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance strip, Galvanised for cables up to 2 x 10 sq.mm.3x10 sq.mm, 4x6 mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part-1) 1988 armoured U.G. cable laid in ground/partially in air (as required for termination up as specified and directed by the deptt. (RR Kabel/Havells/Polycab make or equivalent). 50.00 sq.mm 4 (A2XWY A2XFY) core armoured U.G. cable.
Payment to be made to the APDCL authority for load security (Convert single to 3 phase) per quarter 8 KW load consider for 5 nos quarters each.
Payment to be made to the APDCL authority for domestic 3 phase energy meter.
GIRENDRA BARO
DHARAMSING NARZARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .