Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC FLAT NO 04 3RD FLOOR HARI BHAVAN PLOT NO 44 MAHANT ROAD VILLES PARLE EAST MUMBAI 400057 | MUMBAI SUBURBAN | MAHARASHTRA | 400057 | ₹39.2 L Quoted ₹39.4 L | L1 | Accepted-AOC Acceptance |
| 2 | L2₹41.4 L+₹1.9 L (4.93%)Rejected-Finance | ₹41.4 L+₹1.9 L (4.93%) | L2 | Rejected-Finance Higher Bidder |
| 3 | L3₹41.4 L+₹2.0 L (5.10%)Rejected-Finance | ₹41.4 L+₹2.0 L (5.10%) | L3 | Rejected-Finance Higher Bidder |
| 4 | L4₹42.4 L+₹2.9 L (7.48%)Rejected-Finance FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹42.4 L+₹2.9 L (7.48%) | L4 | Rejected-Finance Higher Bidder |
| 5 | L5₹42.8 L+₹3.3 L (8.49%)Rejected-Finance SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | ₹42.8 L+₹3.3 L (8.49%) | L5 | Rejected-Finance Higher Bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
29 Nov 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO BUILDING NO P 14 INAS310 AT INS HANSA UNDER GE (NW) VASCO
2021_MES_452924_2
85435/E8
Open Tender
Civil Works
Item Rate
180 days
CWE (NW) VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (NW) VASCO
₹94,000
Yes
15 Jan 2022
1 Nov 2021
1 Dec 2021
1 Nov 2021
29 Nov 2021
15 Nov 2021
Amount
Schedule 'A' Part I - B/R portion
Chipping removing carefully concrete work by low impact hammer, breaker without damaging the structure & cleaning and disposal of debris out side the premises etc complete all as specified and as directed. Hard concrete should not be removed by force.
Clean existing reinforcement with wire/ rotary wire brush making the surfaces free from loose material dirt etc complete, Applying Rust off 100, rust remover cum Passivator of approved make on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating of approved make complete all as specified and as directed
M&L for carry out application of 'corrosion Inhibiting Impregnation of approved make on concrete surface. based on organic compounds penetrates to a virtual extent of 100 mm through pores of concrete and form a protective monomolecular layer on the surface of the Reinforcing steel, it Should complies to EN-1504-9 method 11.3 (applying inhibitor to the concrete).The coating should not alter water vapour diffusion properties of the concrete . the coating should protects cathodic (principal 9) and anodic (Principal 11) zones of Reinforcement complete all as specified and as directed
M&L for providing and applying Epoxy resin Bonding agent of approved make prior to application of any type of mortar plaster conforming to ASTM-C-881-78type II , Grade 2 , class B+C to ensure bond between old concrete and new concrete complete all as specified and as directed
M&L for rebuilding the section of damaged RCC elements to its original size in average thickness of 30 mm not exceeding 15mm in each layer by hand or spray application by providing and applying epoxy latex additives of approved make fibre reinforced, dual shrinkage compensated trowalable ,thixotropic cementitious structural repair mortar on exposed concrete surface as per technical specification. Material should have Compressive strength of 50 Mpa on 28 day and 20 MPa in 24 hour ,tensile strength in flexural of>- 6 Mpa in 7 days and tensile adhesion strength of 8 Mpa in 7 days with a consumption of water: powder ratio of 0.16, and mixing ratio of water :powder 0.15-0.16 by weight ( 4.5 - 4.8 ltr of water per bag ) , with a consumption of 2.2 kg per sqm per mm complete all as per manufacturer instruction and directed by Engineer in Charge.
M&L for drilling and fixing Non returnable valve (NRV) Nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep hole in structural members at the interval of 500mm center to center in staggered manner or as directed by Engineer-in-Charge in RCC structural element. Work shall b e carried out as under :- (i) Cleaning of holes - Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles - Insert 12mm dia Non returnable valve (NRV) Nozzles in cleaned holes. External end of nozzle to be machine to receive outlet of grouting gun. Fix it inside the hole by applying thixotropic structural epoxy adhesive of approved make the to ensure complete sealing . Cure the system for min 12 hrs. (iii) Cutting of nozzles - Cut the nozzles by chiser after completion of grouting without damaging structural elements.
M&L for injecting at site, cement slurry grout, in the ratio 1:2 (1-Cement, 2-Water) including expanding non shrink grout admixture of approved make as specified 500 gm/50 Kgs bag. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/sqcm etc. complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled complete all as specified and as directed. (for repair to slab)
M&L for grouting injecting in two part, low viscosity injection resin of approved make, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout.. Seal the nozzle with thixotropic epoxy putty after the refusal of grout material from the nozzle. Note: leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost. Mixing of materials :- Mixing of material components (part a&b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting maintain the pressure at exit (0.5 to 1.0 kg/cm2) by monitoring pressure gauge at exit. Repeat the process for all the nozzles. (for Beam and columns) complete all as specified and as directed
M&L for providing and applying jacketing around damaged member of columns providing and casting with ready to use non shrink, cementitious free flow micro-concrete of approved make at level, having compressive strength > 60 N/mm2 (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18mm thickness and drilling holes and fixing shear anchor of approved make, supporting formwork, all lead lift, mixing, placing, de-shuttering, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any to satisfaction of Engineer-in-charge and curing complete all as specified and as directed Notes: Reinforcement shall be measured and paid separately. Rates including jacketing, formwork and micro concrete.
Replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter of approved make and applying protective coating of approved complete all as specified and as directed
M&L for mild steel TMT bars 10mm dia and over cut length bent to shape required including cranking bending spherically for hooping for columns, hooking ends and binding with and including mild steel wire complete all as specified and as directed
All as per item No 11 here in before but 6 to 8 mm dia complete all as specified and as directed
Dismantling/Taking out existing hessian base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled as directed by Engineer-in -charge.
M&L for applying evenly and priming with oil bound bituminous primer at 0.4 ltr per sqm for water proofing treatment complete all as specified and as directed
M&L for APP based polymeric membrane miniumum weighing 3 kg / sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed
M&L for providing 10mm thick plaster in cement mortar1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement complete all as specified and as directed Note :- Integral water proofing compound will be measured and paid separately
Demolition of concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed
M&L for cutting chases, pinning in, making good to facing where required and pointed in cement mortar 1:3 and making good cutting exceeding 10 cm girth complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for like complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Sqm each complete all as specified and as directed
All as per item 21 here in before but size exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as specified and as directed
Dismantling old particle boards/plywood as in shelves boarding, any description, fixed in any position with nails complete all as specified and as directed
Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed.
Dismantling asbestos cement/PVC pipe including clamps complete all as specified and as directed
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and as directed
M & L for 50mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floor topping, surfaces finished even and smooth without using extra cement complete all as specified and as directed
M&L for providing 40 mm thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in floors finished the surfaces even and rough to receive to topping layers like similar work as required complete all as specified and as directed
M&L for screed bed or bedding layers of 15 mm thick cement mortar 1:6 for laying floor finishes complete all as specified and as directed
M&L for vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for non-skid colour ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors set and jointed in cement slurry @ 3 Kg/Sqm and pointed in white or colour cement to match existing surfaces complete all as specified and as directed
M&L for rendering 10 mm thick cement mortar 1:4 to receive tiles in vertical surfaces complete all as specified and as directed
M&L for vitrified ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for glazed ceramic tiles in vertical surface 300 X 450 X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed
Demolition of stone slabs and tiles of any description or thickness in floors ,aprons etc complete all as specified and as directed
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
M&L for RCC 1:1.5:3 ( Type A 1 ) using 20 mm graded aggregate in slabs supported on walls , beams etc .and columns landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. (Reinforcement measured separately).
M&L for use & waste wooden form work (rough finished) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal/sloping) complete all as specified and as directed
S&F Factory made 100 % solid wood plastic (WPC) decorative door frame ,single rebate of size 75 mm x 50 mm made from wood plastic composite (single extruded process) material with density 78 Kg/cum complete all as specified and as directed
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with head moulded Prelam PVC 'C' channel having a both side Prelam PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side Prelam PVC sheet for top rail, lock rain & bottom rail paneling of plain gap insert for top rail & bottom rail paneling of both side Prelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails feathered at edges/with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and as directed
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed
Supply and Fixing 100 mm size butt hinges medium weight cold rolled stainless steel complete all as specified and as directed
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodized complete all as specified and as directed
S&F Aluminium alloy, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 140 mm complete all as specified and as directed
S&F 12 mm thick single side pre laminated wood grain solid PVC sheet suitably fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work including all hardware fittings complete all as specified and as directed
S&F 18 mm thick single side pre laminated wood grain solid PVC sheet suitably fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work including all hardware fittings complete all as specified and as directed
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the approved standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured inclusive of all fittings fixtures, handle, rubber gasket/rubber beading and locking arrangements.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including standed aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and as directed
S & F Aluminium alloy wire mesh, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and as directed
S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane complete all as specified and as directed
S & F Aluminium anodised,150mm barrel tower bolts of extruded section complete all as specified and as directed
S&F Aluminium handles, cast type, anodised 125mm long fixed with screws complete all as specified and as directed
M&L for providing 150 mm thick cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate with water proofing compound @ 3% of weight of cement as in water tank rest plate form even and smooth complete all as specified and as directed
M&L for pre - cast cement concrete 1:3:6 type C-5, block masonary with solid blocks built in cement mortar 1:6 complete all as specified and as directed
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia complete all as specified and as directed
All as per item no.56 here in before but 20 mm dia complete all as specified and as directed
Supplying and laying of 16 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed
All as per item no.58 here in before but 20 mm dia complete all as specified and as directed
Dismantling water tank 1000 ltr and removing from site complete all as specified and as directed.
S&F 1000ltr rotational moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position complete all as specified and as directed
S&F 500ltr rotational moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position complete all as specified and as directed
Disconnecting existing tanks of capacity exceeding 500 and not exceeding 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed (Cleaning repairing, etc. measured separately)
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. capacity exceeding 500 and not exceeding 1000 ltrs complete all as specified and as directed
S&F PVC ball valve 20mm dia high pressure of PTMT with aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed
S&F 20 mm bore dia stop/Gate valve cast copper alloy screwed down high pressure with critch or bitter fly handle screwed both ends for iron pipe or for union, complete all as specified and as directed.
S&Fs in repair, vitreous china under counter wash basin, size 575 x 430 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and as directed
S & F Push type pillar cocks fancy type cast copper alloy chromium plated concealed type approved make and approved by GE with necessary fixing arrangements and connecting to water pipe connected complete all as specified and as directed
S & F in repair Vitreous china white squatting pan orissa pattern of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, complete all as specified and as directed
S & F in repair Vitreous china white washdown water closet pedestal pattern including necessary lime concrete and 100 mm bore cast iron ‘S’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, including necessary connections and jet pressure with nozzle complete all as specified and as directed
S&F in repair PVC low level flushing cistern 10 Ltrs capacity ISI Marked including all assessories and 32 mm dia PVC flush/discharge pipe including float valve, inlet PVC connection 15mm bore complete all as specified and as directed
S&F PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified and as directed
S&F PVC waste pipe 32mm dia of length 900m m PTMT complete all as specified and as directed
S&F Reflection Mirror size 60 x 45 cm complete all as specified and as directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed
S & F in repair towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified and as directed
S & F 125mm dia CP brass shower rose with swivel joints, any colour CP brass as in repair complete all as specified and as directed
S & F in repairs 15mm bore stop valves of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) complete all as specified and as directed
S & F in repairs 20 mm bore Stop cock Cast copper alloy screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union complete all as specified and as directed
S & F 15mm Bib tap of Cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S & F in repair low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm, 450mm long, heavy duty with two sets of brass nuts & washers (one at each end)etc suitable for 15mm bore of pipe complete all as specified and as directed
S & F 110 mm bore PVC (SWR) "P" Trap complete all as specified and as directed
M&L for PVC (SWR) gully traps 125 x 110 mm, setting and jointing with solvent cement complete all as specified and as directed
M&L for PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and as directed
S&F in repair harrison curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed
S&F 110 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified and as directed
S&F 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified and as directed
S&F PVC (SWR) bends any radius, 110mm bore, fitted with oval access door complete all as specified and as directed
S&F bend suitable for 110mm dia PVC (SWR) pipe complete all as specified and as directed
S&F PVC (SWR) bends any radius, 75mm bore, fitted with oval access door complete all as specified and as directed
S&F PVC (SWR) reducers any radius 110mm bore complete all as specified and as directed
S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal with door access complete all as specified and as directed
S&F PVC (SWR) vent cowl 75mm dia complete all as specified and as directed
M&L for dubbing out average 20 mm thick on irregular face of external and internal walls surfaces (when specifically ordered in writing) in cement mortar 1:6 complete all as specified and as directed
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement in cement mortar 1:6 complete all as specified and as directed
M&L for rendering 15mm thick on other than fair faces of brick or stone masonry surfaces of walls in Cement mortar 1:4 in two coats, 10mm thick and finished with 5mm thick mixed with approval water proofing compound @ 3% by wt of cement finished even & smooth without using extra cement complete all as specified and as directed Note : Water proofing compound will be measured and paid seperately.
Supply only water proofing compound complete all as specified and as directed
M&L for rendering 5mm thick on ceiling concrete surfaces finished even & smooth without using extra cement in cement mortar 1:3 complete all as specified and as directed
M&L for applying three coats of white wash on newly plastered surfaces of wall including preparation of surfaces complete all as specified and as directed
M&L for complete removal of existing treatment and applying three coats of white wash on old plastered surfaces of wall including preparation of surfaces complete all as specified and as directed
M&L for two coats of oil bound distemper over a coat of primer with 3mm wall care putty finish after preparation of new plastered surface complete all as specified and as directed
M & L for complete removal of existing treatment and preparation of old surfaces of painted walls and applying two coats of acrylic anti-fugal weather proof exterior grade paint of first quality over a coat of primer complete all as specified and as directed
M&L for Preparation of new surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer complete all as specified and as directed
M&L for applying one coat of white wash on old plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed
M&L for applying three coats of white wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed
M&L for applying two coats of water proofing treatment by using approved make @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat (alongwith suitable pigments for colour as directed by Engineer-in-Charge all as specified in manufacturer's instructions and to be applied through applicator of authorised manufacturer with 5 Years guarantee.
M&L for preparation of old painted surfaces of steel and iron work of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M & L for cement concrete type B-1, 1:2:4 (20mm graded aggregate)in kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed
M&L for cement concrete 75mm thick type C-2 (1:3:6) (20mm graded aggregate) as in plinth protection complete all as specified and as directed
Schedule 'A' Part II - Internal Electrification
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing capping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No. 111 here in before, but for one fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 111 here in before, but for One bell point controlled by one bell push complete all as specified and as directed.
All as per item No 111 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing capping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 10 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as Tees, elbows, junction boxes etc, as required fixed concealed in wall along with one run of 10 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. Note :- Two runs of 10 sqmm cable and one run of PVC conduit shall be measured as one unit length
M & L for FRLS sub main wiring with two runs of single core PVC insulated unsheathed 1100V grade multi stranded copper conductor cable 4 Sqmm size including 25 mm dia PVC concealed conduit fixed in wall including one run 4 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified. Note :- Two runs of 4 sqmm cable and one run of PVC conduit shall be measured as one unit length
S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular bell push, flush type, 6 Amps complete all as specified and as directed.
S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs Modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
S & F in repairs Modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 volts complete all as specified and as directed
S & F in repairs ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S & F in repairs call bell AC, 230 Volts single pole, ding-dong sound type complete all as specified and as directed
S & F in repairs Fan step regulator, 120W - 2 module complete all as specified and as directed
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed
S&F in repairs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one MCB SP 20 Amps, 10 KA 'C 'series, 240 Volts complete all as specified and as directed.
S & F in repairs MCB DB TPN 4 way DB 415 V with 200 A rated bus bar double door type complete all as specified and as directed.
S & F in repairs MCB DB TPN, 4 way, (MCCB + 24 way O/G) double door, vertical type including one MCCB of 100 amps breaking capacity 25 KA, 4 pole without MCB complete all as specified and as directed
Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 25 KA , 4 pole thermal magnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed
S&F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
M & L for earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 3 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed. Note: GI earth wire upto 7.5 RM is included in the unit rate quoted
Taking down from position opening the body cover of Ceiling fan of 1200/1400 mm sweep any type, any make and cutting the existing winding without damaging the stator removing the coil insulation and putting new wire of suitable gauge with correct number of turns of auxiliary and renewal of minor spare parts such as split pins, cater pins, coupling bolt. capacitor holder, terminal adaptor, screws, nuts, spring washers for blade/body etc and replacement of accessories such as ball bearings, gun metal bushes, capacitor, canopy top& bottom, shackle clip assembly and assembling of all parts and painting with two coat of synthetic enamel paint by using electric spray machine similar to match with existing colour main winding, varnishing and baking complete and soldering new lead of copper wire three core cable of size 23/0076 testing complete including transportation from working site to workshop and back and refixing in position testing complete all as specified and as directed
Taking down Exhaust fan from its position and keeping aside in safe custody complete all as specified and as directed
M&L for rewinding of ceiling fan motor of 1200/1400 mm sweep with new supper enamelled copper winding wire of existing gauge and number of turns and applying insulated varnish and assembling including removing burnt out copper winding wire complete all as specified and as directed
S & F in repairs energy efficient surface mounted LED Luminaire 20 watts 4' long, with acrylic cover complete with all Each accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 m complete all as specified and as directed
S&F in repairs downlight 2' x2' LED surface mounting lights flat panel 36 watt white powder coated CRCA housing with highpower LED's ,aluminium front frame with flat white high transmission acrylic cover,internally prewired 230V complete with all accessories such as electronic driver,LED strip,connector block etc and necessary fixing arrangments of any height and removing old unserviceable item complete all as specified and as directed
S & F in repairs recess mounting high lumen LED flat panel 1'X1' 18 Watt, white powder coated CRCA housing with high power LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed.
S&F in repairs LED light fitting 1x18 watts Surface mounted LED downlighter in powder coated white finish with integrated electronic driver complete all as specified and as directed.
S & F in repairs energy efficient surface Mounted LED Luminire 10 watts 2' long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 m complete all as specified and as directed.
S & F in repairs energy efficient LED building security light Luminire 90 watts capacity comprises a die cast aluminium housing including connections with 2 runs of 2.5 sqmm copper unsheathed wire multistranded and IP 66 protection building security lights(connection wires shall not be less than 2.5 m in length duly run through GI bracket) complete all as specified and as directed.
M & L for street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and as directed.
S&F Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and as directed.
Dismantling carefully the existing window type AC 1.5/2.0 TR capacity from the position keep in safe custody and refixing in serviceable condition after renovation of bldg work complete including replacement gas filling complete all as directed. (Note :- After taking down,AC will be in contractor custody to keep in safe condition)
Dismantling carefully the existing split type AC (indoor & outdoor unit) 1.5/2.0 TR capacity from the position keep in safe custody and refixing in serviceable condition after renovation of bldg work complete including replacement new copper pipes , gas filling and replacement of mounting brackets complete all as directed. (Note :- After taking down ,AC will be in contractor custody to keep in safe condition)
Schedule 'A' Part III - External Electrification
Taking down of old unserviceable cable of any core and size from any description complete all as specified and as directed
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 70 sq mm 3.5 core all as specified and as directed Note:Excavation, PCC cable cover and Sand for cushioning shall be measured and paid separately
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth in hard /dense soil getting out and levelling pf bottom surface to required level for laying UG cable/erection of poles complete all as specified and as directed
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth in soft/disintegrated rock getting out and levelling pf bottom surface to required level for laying UG cable/erection of poles complete all as specified and as directed
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and as directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated material complete all as specified and as directed
Removal of surplus excavated material to a distance not exceeding 50 m and depositing where directed not exceeding 1.5m from starting point complete all as specified and as directed
Supplying & laying in trenches clear sand/m sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified. Note:Punned thickness of sand will be measured.
Supply and lay PCC cable cover class LV, type I, flat size 250 mm x 150 mm x 40mm with in trenches to protect under ground cable all as specified and as directed
M/S Kartik Enterprises
M/S. M M S ENTERPRISES
M/s J.D. DESAI
Tara Construction
M/S P S BABU
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .