Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | ₹21.3 L Quoted ₹21.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹25.3 L+₹3.8 L (17.8%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | ₹25.3 L+₹3.8 L (17.8%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹26.8 L+₹5.3 L (24.9%)Rejected-Finance 30 B 1 DEEN DAYAL NAGAR NAWABGANJ DEEN DAYAL NAGAR KANPUR NAGAR UTTAR PRADESH 208002 | KANPUR NAGAR | UTTAR PRADESH | 208002 | ₹26.8 L+₹5.3 L (24.9%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹28.2 L+₹6.8 L (31.6%)Rejected-Finance | ₹28.2 L+₹6.8 L (31.6%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹29.6 L+₹8.1 L (37.9%)Rejected-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | ₹29.6 L+₹8.1 L (37.9%) | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
14 Jun 2021, 6:00 pmClosed
GE
GE 860 EWS
REPAIR/ MAINTENANCE TO LT PANEL BOARD, FEEDER PILLAR BOXES, JUNCTION BOXES, REMOVAL OF LT PANEL BD AND CONNECTED WORK SERVICES AT KARU ZONE II AND SHESHARTHANG UNDER GE 860 EWS
2021_MES_443426_1
8141/2021-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Karu
Class D and category b i
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS
₹98,000
Yes
20 Jul 2021
17 May 2021
16 Jun 2021
17 May 2021
14 Jun 2021
31 May 2021
Amount
S&F, in replacement, MCCB, 415 volts, 04 pole, 63 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 100 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 160 Amps, 36 KA, adjustable type , including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 200 Amps, 36 KA, adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 250 Amps, 36KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 400 Amps,36 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 63 Amps, 35 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider Cat Part No. LV510315 or equivalent make as mentioned in particular specifications
S&F, in replacement, MCCB, 415 volts, 04 pole, 100 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider Cat Part No. LV510317 or equivalent make as mentioned in particular specifications
S&F, in replacement, MCCB, 415 volts, 04 pole, 160 Amps, 36 KA, adjustable type , including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider Cat Part No. LV516313 or equivalent make as mentioned in particular specifications
S&F, in replacement, MCCB, 415 volts, 04 pole, 200 Amps, 36 KA, adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider Cat Part No. LV525312 or equivalent make as mentioned in particular specifications
Taking out old UNSV LT panel board / Junction box of any size complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 160 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA= 04 Nos (O/G) (d) MCB Isolator 4 Pole 63 Amps, 415 Volts, AC = 06 Nos (O/G)
(e) MCB SPN 63 Amps, 230 Volts, AC = 03 Nos (O/G) (f) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent - 01 No (g) Phase indicating lamp = 03 Nos (R, Y, B) (h) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 200 Amps, 415 Volt, AC, 25 KA= 01 Nos (I/G) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 01 Nos (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA= 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 08 Nos (O/G)
(e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent - 01 No (g) Phase indicating lamp = 03 Nos (R, Y, B) (h) Aluminium bus bar of capacity 300 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 200 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC ,25 KA = 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA = 04 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G)
(e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent -01 No (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 300 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) . Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 160 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G) (d) MCB Isolator 4 Pole 63 Amps, 415 Volts, AC = 01 Nos (O/G)
(e) MCB SPN 63 Amps, 230 Volts, AC = 02 Nos (O/G) (f) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent - 01 No (h) Phase indicating lamp = 03 Nos (R, Y, B) (j) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 200 Amps, 415 Volt, AC, 25 KA= 01 Nos (c) MCCB 4 pole, 160 Amps, 415 Volt, AC, 25 KA= 02 Nos (d) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 03 Nos
(e) On load change over switch (side handled) 4 pole, 400 Amps, 415 Volt = 01 Nos (f) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent -01 No (g) Phase indicating lamp = 03 Nos (R, Y, B) (h) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 250 Amps, 415 Volt, AC, 25 KA= 02 Nos (O/G) (c) MCCB 4 pole, 100Amps, 415 Volt, AC, 25 KA= 03 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G)
(e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent -01 No (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 02 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA= 04 Nos (O/G) (d) MCB Isolator 4 Pole 63 Amps, 415 Volts, AC = 06 Nos (O/G)
(e) MCB SPN 63 Amps, 230 Volts, AC = 03 Nos (O/G) (f) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent -01 No (g) Phase indicating lamp = 03 Nos (R, Y, B) (h) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 06 Nos (O/G)
(e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent -01 No (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA = 01 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 06 Nos (O/G)
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate). Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 160 Amps, 415 Volt, AC, 25 KA= 03 Nos (O/G) (c) MCCB 4 pole 100 Amps, 415 Volt, AC, 25 KA = 03 Nos (O/G) (d) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G)
(e) MCB SPN 63 Amps, 230 Volts, AC = 10 Nos (O/G) (f) Onload changeover side handle operated 4 pole 400 A = 02 Nos (g) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T or equivalent -01 No (h) Phase indicating lamp = 03 Nos (R, Y, B) (j) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 160 Amps,240/415 Volt, 50Hz, 10 KA= 01 Nos (I/C) b) MCB SPN 63 Amps, 240 Volts - 04 Nos (O/G)
Note : Unit rate quoted by the contractor here-in-before also includes for fixing and connecting of MCBs and installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply and fix aluminium lug of 185 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 150 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 120 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 95 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 70 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 50 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 35 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 25 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 16 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Supply and fix aluminium lug of 10 Sqmm in single core of cable by removing old/burnt cable from changeover/Panel/DG set all as directed by Engr-in-Charge
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to Poles/panels all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of cable/ stay assy/LT poles and getting out in hard/dense soil complete all as specified and directed.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil complete all as specified.
Removing excavated material not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point complete all as specified.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
Laying only un-reinforced pre-cast concrete cable covers, of any size as retrieved from serial item No 04 here-in-before complete all as directed by Engineer-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M & L Sand cushioning to underground cable complete all as specified in clause 19.75 of SSR Part - I.
S&F of galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 240 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
All as srl item no 44 here-in-before but for cable size of 16 sqmm 2 core.
All as srl item no 44 here-in-before but for cable size of 10 sqmm 2 core.
Supply and installation ON LOAD change over switch (side handle) 415V in sheet metal enclosures 4 pole of capacity 320 Amps complete all as specified.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron earth strip 32 x 6 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to transformer/panel all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) . Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,35 KA = 01 Nos (I/C) (b) On load change over switch with advance neutral, 400 Amps, 4 Pole, 415 Amp -02 (Side handle) (c) MCCB 4 pole, 160 Amps, 415 Volt, AC ,35 KA = 03 Nos (O/G)
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) . Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 125 Amps, 415 Volt, AC ,35 KA = 01 Nos (I/C) & (O/G) (b) On load change over switch with advance neutral, 125 Amps, 4 Pole, 415 Amp -01 (Side handle)
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) . Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 200 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) Automatic Star Delta Starter for submersible motor, 3 Phase 50 Hz incl Low and High voltage protection, upto 10 HP - 02 Nos (c) MCCB 4 pole, 100 Amps, 415 Volt, AC ,25 KA = 01 Nos (O/G) (d) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G)
Supply, installation, testing and commissioning, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) . Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 200 Amps, 415 Volt, AC ,25 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC ,25 KA = 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G)
Supply, installation, testing and commissioning, LT Panel board, cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) and aluminium bus bar of size 630 Amps capacity , Single phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge. (a) MCCB 4 pole, 160 Amps,415 Volt,AC , 25 KA= 01 Nos (I/C) (b) MCCB 63 Amps, 415 Volts, AC , 25 KA - 03 Nos (O/G)
M/S BHAT ENGINEERS
M/S ASHISH AND CO
HILL AND CO.
Hitech Erectors Pvt. Ltd.
M/S TRADE LINK
KIRTI ELECTRICALS
EESSI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .