Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-AOC BLOCK D FIRST FLOOR COMMERCIAL COMPLEX KUNJ BIHARI AGRAWAL KORBA KORBA KORBA CHHATTISGARH 495677 | KORBA | CHHATTISGARH | 495677 | ₹5.0 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹5.1 Cr+₹6.0 L (1.20%)Rejected-Finance | ₹5.1 Cr+₹6.0 L (1.20%) | L2 | Rejected-Finance The L2 Bidder |
| 3 | L3₹5.4 Cr+₹43.8 L (8.77%)Rejected-Finance | ₹5.4 Cr+₹43.8 L (8.77%) | L3 | Rejected-Finance The L3 Bidder |
| 4 | L4₹7.7 Cr+₹2.7 Cr (53.7%)Rejected-Finance 3RD FLOOR KANKU COMMERCIAL COMPLEX INDIRA GANDHI ROAD NEAR JANTA FATAK JAMNAGAR GUJARAT 361006 | JAMNAGAR | GUJARAT | 361006 | ₹7.7 Cr+₹2.7 Cr (53.7%) | L4 | Rejected-Finance The L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹5.0 L
Closing Date
2 Dec 2024, 4:00 pmClosed
S E EMCCIII 1X660 MW PTEP Panki UP
Office of the Superintending Engineer EMCCIII 1X660 MW PTEP Panki UP
Biennial contract for Round the clock routine preventive and breakdown maintenance of entire Electrical System of Main Plant and Offset areas BOP excluding CHP along with engagement of electrical field operation assistance of 1x660 MW PTEP Panki
2024_RVUNL_967177_1
ET01EMCCIIIEMCDVIIIPTEP202426
Open Tender
Electrical Works
Fixed-rate
730 days
Kanpur
As per PQC
3 documents required · 3 mandatory
₹11,800
Dy CAO CFA and BO PTEP Panki Kanpur
₹5.0 L
24 Mar 2025
21 Oct 2024
4 Dec 2024
21 Oct 2024
2 Dec 2024
21 Oct 2024
21 Oct 2024 - 2 Dec 2024
Amount
PART-A: MAINTENANCE OF HT MOTORS
12 Weekly Checks (Quarterly PM) of HT motors
HT MOTORS (>1500-2500 KW)-24 W Checks
HT MOTORS (>2500-5000 KW)-24 W Checks
HT MOTORS (>5000 KW)-24 W Checks
HT MOTORS Terminal connection/disconnection
Deployment of highly skilled manpower for unscheduled jobs
Deployment of skilled manpower for unscheduled jobs
Deployment of semi skilled manpower for unscheduled jobs
HT Motor weekly checks above 1500 KW
HT MOTORS (>1500-2500KW) Attend Defect/Servicing
HT MOTORS(>2500-5000 kW)-Attend Defect/Servicing
HT MOTORS(>5000 KW)-Attend Defect/Servicing
HT MOTORS (>1500-2500 KW) Shifting/rotation
HT MOTORS(>2500-5000 KW) Shifting/rotation
HT MOTORS(>5000 KW) Shifting/rotation
Circuit identification/labelling on panels/equipments by Painting background with two or more coats on new work with synthetic enamel paint of approved brand and manufacture to give an even shade and lettering with black japan paint of approved brand and manufacture
Painting of various types of panels/equipments
Part-B: HT SWITCHGEAR MAINTENANCE (11 KV)
PM of 11 KV Breakers
Maintenance of Power Busbar of 11 KV switchgear boards
Breakdown jobs and checking of HT breakers and HT switchgears,
Highly Skilled manpower deployment for unscheduled jobs
Skilled manpower deployment for unscheduled jobs
Semi Skilled manpower deployment for unscheduled jobs
Testing Engineer
PART-C: MAINTENANCE OF TRANSFORMER AND SWITCHYARD EQUIPMENTS
Routine checks of Switchyard Equipment
Antiweed Treatment & removal of grass from Switchyard
Troubleshooting of Switchyard Defects
Troubleshooting of SAS/SCADA System & BCUs/IEDs/Data Concentrator/BTS
Station Earthing System Checks
Routine checks of Transformers/Reactor rating more than 10 MVA
Routine checks of Transformers up to 10 MVA
Shutdown/Breakdown Maintenance of Transformer more than 10 MVA/Reactor
Preventive maintenance of Transformer upto 10 MVA
Breakdown maintenance of Transformer upto 10 MVA
Oil filtration of transformers/Reactor rating more than 10 MVA
Oil filtration of transformers rating up to 10 MVA
Oil Sample collection of transformers/Reactor
Shutdown/Breakdown Maintenance of Switchyard Equipments
Switchyard 400 KV Circuit Breaker Replacement
Circuit Breaker Drive Mechanism Replacement
Bushing Replacement of Transformer more than 10 MVA
Switchyard Isolator/Earth switch/CT/CVT/LA Replacement
Replacement of damaged ACSR Conductor
Replacement of damaged Clamp/Tightening of Clamp
House Keeping of Switchyard Control Room building
Painting of HT/LT Busducts, HT/LT Transformers, HT/LT Motors, and other electrical equipments,
PART-D: MAINTENANCE OF GENERATOR AND AUXILLIARIES
Assistance in Daily checking of Generator parameters and Upkeep of various panels of Generator & its auxiliaries including IP, SP, NSPBD, Air pressurization units, PT cubicles, CT & PT, Marshalling boxes, ECUP
Transportation/Loading/Unloading of H2 gas filling
Servicing/Overhauling of pump of seal oil system as per scope of work
Servicing/Replacement of float trap valve as per scope of work
Servicing/Replacement of valves of H2 Gas/Seal Oil System/Primary Water System Valve as per scope of work
Removal of H2 gas from Generator as per scope of work
Filling of H2 gas in Generator as per scope of work
Alignment of Primary Water/Seal oil pumps with AC/DC motor as per standard procedure.
Replacement of AC/DC Seal Oil Pump as per scope of work.
Replacement of following by isolating & dismantling and assembling & installation after completion of work
Bearing of Seal oil pump
Mechanical Seal of seal oil pump.
Servicing /Overhauling/Bearing replacement of Primary Water Pump
Replacement/Cleaning of Seal oil system duplex Filter
Replacement/Cleaning of SWCS cooler Filter
Replacement of Resins
Servicing of Duplex filter of Seal oil system as per scope of work
Attending Leakage from Generator Gas coolers as per scope of work
Replacement of defective Generator Hydrogen Gas cooler
Detecting Hydrogen gas leakage with help of soap solution and attending minor gas leakage from entire generator system
Breakdown maintenance of Thyristor cooling fans
Replacement of rubber expansion bellows of phase and neutral side of generator Terminal/Phase
Work on IP/NSPBD/SP bus ducts of UT/UAT/GT
Cleaning/replacement of flexible links of phase/neutral side, Main run, Delta run and TAP OFF run of generator terminal as per scope of work
Replacement of phase/neutral side protection CT
Deployment of highly skilled manpower for unscheduled jobs
Deployment of skilled manpower for unscheduled jobs
Deployment of semi-skilled manpower for unscheduled jobs
PART-E: Engagement of Electrical Field Operation Assistant (Operator) Round the clock in Shift for two years for 11 KV and above
Shift Operator for Operation of Main Plant HT Switchgear, MCC rooms and DC battery room.
Shift Operator for Operation of Transformer and Switchyard area
PART-F: LIGHTING, WELDING AND CABLING NETWORK MAINTENANCE
Daily Routine and breakdown maintenance of lighting division
Laying of GI wire/strips
Laying of GI pipes and gi/pvc/flexible conduits
Battening/casing capping on wall
Laying of PVC flexible single core wires
Laying of power/control cables of dia upto 10 mm
Laying of power/control cables of dia above 10 mm and upto 40 mm
Laying of power/control cables of dia above 40 mm and upto 80 mm
Excavation of trench
Jointing and end termination of control cables of all sizes
Jointing and end termination of LT power cables of all sizes
Up-keeping of various cable galleries /trenches and racks
Circuit identification/labelling on panels/equipments by Painting background with two or more coats on new work with synthetic enamel paint of approved brand and manufacture to give an even shade and lettering with black japan paint of approved brand and manufacture
Fabrication & fixing of canopy (size up to 0.5 sq.mtr.)
Shift maintenance of lighting and welding network (consisting of one gang of one skilled electrician and one un-skilled helper)
Supplying of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size: 20 mm
Supplying follwing size of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required
2 x 2.5 sq. mm
2 x 4 sq. mm
Maintenance of light fittings and associated equipments
Maintenance of fans and associated fixtures
Overhauling of lighting panels
Maintenance of LED based aviation obstruction light fitting (up to 275 mtr height)
Installation of TL/GLS/CFL/LED/HPSV/Halogen lamp fittings (upto 70W)
Installation of HPSV/MH/LED lamp fittings (above 70W)
Installation of single phase office and industrial equiments
Jointing and end termination of HT power cables of all sizes
Painting of street light poles
Painting of various types of panels/equipments
Fabrication & fixing of canopy (size >0.5 sq.mtr. & up to 1 sq.mtr.)
Supplying of metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Size: 200x125x60 mm
Size: 200x250x75 mm
Supplying of following switch/socket on the existing switch box/cover including connections etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
5 pin 15/16 A socket outlet
Supplying following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Rating: 25Amps
Supplying following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and Fixing of 18/20 Watt 4 feet LED Batten Light of ISI marked reputed brand
PART-G : MAINTENANCE OF HT AND LT MOTORS (3.3 KV and below)
LT MOTOR (<=2.2 KW) Attend Defect
LT MOTOR (>2.2-5.5 KW) Attend Defect
LT MOTOR (>5.5-18.5 KW) Attend Defect
LT MOTOR (>18.5-37 KW) Attend Defect
LT MOTOR (>37-55 KW) Attend Defect
LT MOTOR (>55-90 KW) Attend Defect
LT MOTOR (>90 KW) Attend Defect
DC MOTORS(<=10 KW)-Attend Defect
DC MOTORS(>10-20 KW)-Attend Defect
DC MOTORS(>20 KW) Attend Defect
LT MOTOR (<=5.5 KW) Connection
LT MOTOR (>5.5-18.5 KW) Connection
LT MOTOR (>18.5-37 KW) Connection
LT MOTOR (>37-55 KW) Connection
LT MOTOR (>55-90 KW) Connection
LT MOTOR (>90 KW) Connection
12 Weekly Checks (Quarterly PM) of HT motors
HT MOTORS (<=1000 KW)-24 W Chks
HT MOTORS (>1000-1500 KW)-24 W Chks
HT MOTORS Terminal connection/disconnection
LT (AC and DC) MOTOR, ratings upto 200 KW, 12 Weekly Checks
LT (AC and DC) MOTOR, ratings upto 200 KW, 24 Weekly Checks
LT MOTOR (<=2.2 KW) OH/Servicing
LT MOTOR (>2.2-5.5 KW) OH/Servicing
LT MOTOR(>5.5-18.5 KW)- OH/Servicing
LT MOTOR(>18.5-37 KW)- OH/Servicing
LT MOTOR(>37-55 KW)- OH/Servicing
LT MOTOR(>55-90 KW)- OH/Servicing
LT MOTOR(>90 KW)- OH/Servicing
DC MOTORS(<=10 KW)- OH/Servicing
DC MOTORS(>10-20 KW)- OH/Servicing
DC MOTORS(>20 KW)- OH/Servicing
Deployment of highly skilled manpower for unscheduled jobs
Deployment of skilled manpower for unscheduled jobs
Deployment of semi skilled manpower for unscheduled jobs
HT Motor weekly checks upto 1500 KW
HT MOTORS (<=1000 KW) Attend Defect /Servicing
HT MOTORS (>1000-1500 KW) Attend Defect/Servicing
LT MOTOR (<=10 KW) Shifting/Replacement
LT MOTOR (>10- 30 KW) Shifting/Replacement
LT MOTOR (>30-75 KW) Shifting/Replacement
LT MOTOR (>75-90 KW) Shifting/Replacement
LT MOTOR (>90 KW) Shifting/Replacement
DC MOTORS(<=10 KW)-Shifting/Replacement
DC MOTORS(>10-30 KW)-Shifting/Replacement
DC MOTORS(>30 KW) Shifting/Replacement
HT MOTORS (<=1000 KW) Shifting/rotation
HT MOTORS (>1000-1500 KW) Shifting/rotation
Rewinding of 3-Phase 440V induction motor
Up to1.0 KW
Above 1.0 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 20 KW
Above 20 KW up to 30 KW
Above 30 KW up to 40 KW
Above 40 KW up to 55 KW
Above 55 KW up to 70 KW
Above 70 KW up to 80 KW
Above 80 KW up to 100 KW
Above 100 KW up to 110 KW
Above 110 KW up to 135 KW
Above 135 KW up to 145 KW
Above 145 KW up to 200 KW
Rewinding of Single phase 240V AC induction motor Up to 1.0 KW
Rewinding of 220V DC Motor/Generator
Up to 1 KW
Above 1 KW up to 5 KW
Above 5 KW up to 20 KW
Above 20 KW up to 40 KW
Above 40 KW up to 60 KW
PART-H: LT AND HT SWITCHGEAR MAINTENANCE (3.3 KV and below)
PM of 3.3 KV Breakers
Maintenance of Power Busbar of 3.3 KV switchgear boards
Maintenance of Power and Control Busbar chambers of LT switchgear and MCC panels
PM All EOT (except TG hall) Attend defect
PM of Hoists and winches
PM of LT Modules
PM of LT Breakers
Breakdown jobs and checking of LT modules, LT breakers and switchgears,
Breakdown jobs and checking of HT breakers and HT switchgears,
Highly Skilled manpower deployment for unscheduled jobs
Skilled manpower deployment for unscheduled jobs
Semi Skilled manpower deployment for unscheduled jobs
PM of DC motor starter panels
Breakdown jobs of DC motor starter panels
PM of Local Control Panels, ACDBs, DCDB etc.,
PM of EOT crane of TG hall
EOT crane of TG hall - attend Defects
Hoists and winches-attend Defect
Shift Electrical Maintenance (2x3x365)
Cleaning of Electrical panels, modules, motors, and Local Control panels
Testing Engineer
PART-I: MAINTENANCE OF DC SYSTEM AND DG SETS
Capacity test of Battery Banks
Assistance in detection and rectification of Earth faults in DC systems
Replacement of defective Cells
Monitoring healthiness and maintenance of Battery Bank
PART-J: MAINTENANCE OF ESP & ASSOCIATED EQUIPMENTS
Arresting of oil leakage from high voltage rectifier transformer
Checking, Cleaning and inspection of ESP area electrical equipments
Annual Preventive & Break-down maintenance of ESP fields/Tr panels
Annual Preventive & breakdown maintenance of ESP rectifier transformers
Oil filtration of Rectifier Transformer of ESP
Cleaning and Inspection of High Voltage rectifier transformer
Deployment of highly skilled manpower for unscheduled jobs
Skilled manpower deployment for unscheduled jobs
Semi Skilled manpower deployment for unscheduled jobs
Replacement of damaged with New/repaired ESP transformer along with negative bushing chamber by dismentalling,lowering down, shifting, lifting up & recommissioning and associated works and connecting it to field
PART-K: Engagement of Electrical Field Operation Assistant (Operator) Round the clock in Shift for two years for upto 3.3 KV
Shift Operator for Operation of Main Plant MV, LV Switchgear, MCC rooms and DC battery room
Shift Operator for Operation of MV, LV Switchgear, MCC room of ESP & FGD
Shift Operator for Operation of MV, LV Switchgear, MCC room of W & WWTP
Shift Operator for Operation of MV, LV Switchgear, MCC room of AHP
M/s STAR ELECTRICALS (BID ID -4735828)
MIRAJ INSTRUMENTATION SERVICES (I) PRIVATE LIMITED (BID ID -4733421)
Excel Technical Services Pvt. Ltd. (BID ID -4759311)
Bidder Name
Excel Technical Services Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .