Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.7 L+₹1.7 L (8.34%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Not being Lowest | |
| 3 | L3₹23.0 L+₹2.1 L (9.79%)Rejected-Finance | L3 | Rejected-Finance Not being Lowest | |
| 4 | L4₹24.6 L+₹3.6 L (17.4%)Rejected-Finance | L4 | Rejected-Finance Not being Lowest | |
| 5 | L5₹26.3 L+₹5.4 L (25.5%)Rejected-Finance WZ 30 1 ASALATPUR JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | L5 | Rejected-Finance Not being Lowest |
Tender Value
₹29.8 L
EMD Value
₹59,560
Closing Date
2 Apr 2025, 6:00 pmClosed
GE (West) Delhi Cantt
GE (West) Delhi Cantt 110010
Provision of internal Putty/Painting of entire DCN Buildings and wall paneling works 1st Floor of P-1 building and Ground Floor of P-2 Buildings at DCN and Addn/Altn and upgradation of internal electrification of Bldg No P1, P2 and P3 at DCN under GE
2025_MES_700455_1
GE/DW-100 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
delhi
Class D Category a(i)
9 documents required · 9 mandatory
₹500
GE (West) Delhi Cantt
₹59,560
Yes
1 May 2025
6 Mar 2025
4 Apr 2025
6 Mar 2025
2 Apr 2025
20 Mar 2025
Amount
M&L for preparing the surface by Complete removal of existing treatment any layer by scraping by mechanical or manual means, wasing down, cleaning and making good including necessary scafolding complete all as specified and directed. Note :( height of building/varanda up to 3 Storey)
M & L Rendering 12-15mm thick in Ready Mix Mortar on brick work, parapet wall, roof beam floor beam and coloumn etc on brick or concrete, wall surfaces and finished even and smooth, including taking down cement plaster any description from wall surface and removing rubbish beyond MOD land complete all as specified and directed and necessary scafolding. Note :( height of building/varanda up to 3 Storey)
M & L Rendering 10mm thick in Ready Mix Mortar on ceiling surfaces and finished even and smooth, including taking down cement plaster any description from ceiling surface and removing rubbish beyond MOD land complete all as specified and directed and necessary scafolding. Note :( height of building/varanda up to 3 Storey)
M&L for 1 mm thick wall care putty to entire surface to bring uniform surafce on wall surface prepared by item No 1 and new plastered surface complete all as specified and directed. Note :( height of building/varanda up to 3 Storey)
M&L for applying two coats of oil bound distemper including one coat of primer using spray machine/roller brushes to entire surface to bring uniform surafce on wall complete all as specified and directed. Note :( height of building/varanda up to 3 Storey)
M&L for preparation of old treated surfaces of ceilling and applying two coat of white wash using spray machine/roller brushes complete all as specified and directed.Note :( height of building/varanda up to 3 Storey)
M&L for preparation of new plastered surfaces of ceilling and applying three coat of white wash using spray machine/roller brushes complete all as specified and directed. Note :( height of building/varanda up to 3 Storey)
M&L for applying two coats of plastic emulsion paint using spray machine/roller brushes to entire surface to bring uniform surafce on wall complete all as specified and directed. Note :( height of building/varanda up to 3 Storey)
M&L for preparation of previously treated /old painted steel and steel based surfaces of any description not otherwise described over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified and directed. Note :( height of building/varanda up to 3 Storey)
S&F Solid PVC Wall Lining/penelling consisting of 5mm thick single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame including 5mm thick PVC sheet fillet of width 35mm for wall paneling at distance of exceeding 30cm centre tor centre on verticl and at every end or joint of sheet in horizontal/vertical cinclusive of fixing on to wall to make PVC Frame as per specification and drawing.
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, sockets, regulator, etc.) and making good disturbed surfaces of walls, floor etc. complete all specified and directed.
Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade in new modular metal flush box of suitable thickness including one coat of syenthetic enamelled black paint with new modular white cover plate with frame of suitable size of required colour fixed with brass screws and cup washers including single core stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for One 3 Pin socket 15A Indepentent board.
Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 4.0 Sqmm size 1100 volts grade including single core stranded FRLS copper conductor 4.0 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for one modular AC box indepentent board.
S&F Modular switch 1 way 16 A,1 module complete all as specified and directed.
S&F of Modular socket outlet 16 A, 2/3 pin, combined 2 module complete all as specified and directed.
Taking down carefully sub main wiring of any make/size/type complete all as specified and directed.
Supply, laying and drawing submain wiring in PVC rigid conduit 02 runs of IC x 10.00 sqmm (Main Cable and neutral) and one run of IC x 10.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade, making good surface of disturbed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
Ditto- all as per Item No. 17 here-in-before but with cable of 6.0 sqmm size.
S & F in repair for sheet metal enclosure MCB DB SPN 12 way with 100 Amps rated bus bar 240 volts double door including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the disturbed surface to match with existing one, complete all as specified and directed.
S & F in repair for sheet metal enclosure MCB DB SPN 8 way with 100 Amps rated bus bar 240 volts double door including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the disturbed surface to match with existing one, complete all as specified and directed.
S&F in replacement of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates, complete all as specified and directed. NOTE :- (a) MCBs & MCCB shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. (c) Make of DB'S and MCB's shall be same.
S&F in repair MCB SP 6 to 32 Amps, 10 KA breaking capacity, 'B' series, 240 volts including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repair of single pole MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete all as specified and directed.
S&F in repair of single pole MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete all as specified and directed.
S & F in repair Miniature circuit breaker (MCB), SPN 40 to 63 AMP, 10 KA, 240V, 'C' series complete all as specified and directed.
S&F in repair of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed.
S&F in repair RCBO, 230 Volt, 40-63 Amps, 30mA, 50 Hz, with 10 kA short circuit capacity of Double pole for ensuring protection from leakage current, short circuit & over load, complete all as specified and directed.
S&F in repair MCCB 4 pole 125 Amp, Icu = 16 KA, 415 volts, 50 Hz, adjustible type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete all as specified and directed.
S&F in repair MCCB 4 pole 160 Amp, Icu = 16 KA, 415 volts, 50 Hz, adjustible type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete all as specified and directed.
M&L for modular AC Box with 20A SP mini MCB, Plastic enclosure & unbreakable Heavy Duty ISI mark Plug Top complete set dully concealed in wall complete all as specified and directed.
HANUMAN BUILDERS (BID ID -3271106)
D K Engineers and contractors (BID ID -3275721)
M/S Davinder Kumar (BID ID -3270653)
GLOBAL DEVELOPERS COMPANY (BID ID -3272620)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .