Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹54.9 L+₹3.0 L (5.71%)Rejected-AOC | L2 | Rejected-AOC other than lowest bid | |
| 3 | L3₹55.2 L+₹3.2 L (6.22%)Rejected-AOC | L3 | Rejected-AOC other than lowest bid | |
| 4 | L4₹55.4 L+₹3.5 L (6.71%)Rejected-AOC VILL PO KUMARHATTI DIST SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | L4 | Rejected-AOC other than lowest bid | |
| 5 | L5₹55.4 L+₹3.5 L (6.76%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L5 | Rejected-AOC other than lowest bid |
Tender Value
₹63.2 L
EMD Value
₹1.2 L
Closing Date
9 Nov 2022, 6:00 pmClosed
CWE Shimla Hills Jutogh
CWE Shimla Hills Jutogh, Jutogh Cantt., Shimla-171008
SPECIAL REPAIR TO BLDG NO. AL-06 (OTM) OF 5/5 GR(FF) AT DAGSHAI CANTT UNDER GE KASAULI.
2022_MES_555975_1
CA NO. CWE/KAS-28 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Dagshai
Plesae refer as per tender documents
7 documents required · 7 mandatory
₹1,000
GE Kasauli
₹1.2 L
Yes
24 Nov 2022
4 Oct 2022
11 Nov 2022
4 Oct 2022
9 Nov 2022
26 Oct 2022
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Demolition Matting, single or double any type including, bamboo framing or bamboo supports, cover fillets, if any complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling timber scantling 40 sqcm and under in section in any position in framed work etc complete all as specified and directed.
Dismantling timber scantling 40 sq.cm and over in section in any position in framed work etc complete all as specified and directed.
Dismantling wall as ceiling board (fibre, pulp, insulation, etc) or insulationboards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but n.exe 2.0 Sqm each complete all as specified and directed.
Demolition of brick or stone masonary built in cement mortar including all quoins arches pillars etc but excluding ashlars facing dressed stone work and precast concrete block, complete all as specified and directed.
Taking down Shutters of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after easing and adjusting complete all as specified and directed.
M&L for Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed.
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed.
Taking down cement plaster on brick or stone wall, Ceilling etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc, complete all as specified and directed.
S&F for 40mm thick 2nd class hardwood as in floors, planed one side, with butt joints and fixed with nails complete all as specified and directed.
M&L for PVC tiles / sheets 1.50mm thick laminated plain coloured, marbled mosaic or motled finish, laid with approved rubber based adhesive in floors complete all as specified and directed.
S&F for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe.290, Gde-E-165, complete all as specified and directed.
S&F for hard drawn steel wire fabric weight n.exc 4 kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntetc complete all as specified and directed.
M&L for 2nd class hard wood over 40sqcm in Scantling clean sawn timber framed and fixed complete all as specified and directed.
M&L fo 6mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work,complete all as specified and directed.
M&L for 2nd class hard wood plain fillets sectional area exc 13sqcm and n.exc 25sqcm, square, rectangular or triangular in section, clean sawn, secured with nails or brads, complete all as specified and directed.
M&L for 2nd class hard wood plain fillets sectional area exc 06sqcm & n.exc 13sqcm, square, rectangular or triangular in section, clean sawn, secured with nails or brads, complete all as specified and directed.
M&L for Rendering 20mm thick on stone work in CM 1:6 etc finished even and smooth without using extra cement complete all as specified and directed.
S&F for 35mm thick factory made 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated etc complete all as specified and directed.
M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exc 6.0m mean radius in cement mortar 1:6, complete all as specified and directed.
M&L for applying 1mm thick wall care putty on walls etc complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coat of oil bound distempering over a coat of Chalk whitening etc, complete all as specified and directed.
M&L for complete removal of existing treatment of walls and applying two coat of oil bound distempering complete all as specified and directed.
M&L for preparation of old plastered/unplastered wall surfaces /complete removal of existing treatment of walls and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make etc complete all as specified and directed.
M&L for preparation of old plastered wall surfaces of any description n exc 10cm width or girth applying two coat of synthetic enamel paint over a coat of primer when unconnected with other painting or when painted in different tint and make etc complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F for aluminium anodized 200mm long barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F for 150mm long aluminium anodized handles febricated type complete all as specified and directed.
S&F for 300mm long aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed etc complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
M&L for Sheet glass 3.00mm thick fixed with windows frame of area of each pane n exc 0.50Sqm complete all as specified and directed.
S&F in repair for curtain rod powder coated ornamntal type dia 25mm including brackes( 2 Nos) , end caps (2 Nos) and taking out existing complete all as specified & directed.
M&L for preparing of wood and wood based material of any description and girth and applying two coats of creosote oil complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket, or power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including concealed conduit PVC of 20mm dia with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing sunken boxes for mounting of switch, socket etc incl taking down unserviceable if required complete all as specified and directed for the following :-
One Light/Fan/bell point controlled by one, one way switch 6 Amp complete all as specified and directed.
One switch socket outlet 3 pin, 5 Amp on the independed board complete all as specified and directed.
One switch socket outlet 3 pin, 5 Amp on same board complete all as specified and directed.
All as per item No 42.00 here-in-before but 4.0 sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLS) cable 1100 volts incuding 4.0 sqmm stranded copper conductor (FRLS) PVC insulated greeen in colour as continous earth conductor connected to common earth and earth dolly with all accessories one 5 pin 16 Amp socket (Power point) on independent board complete all as specified and directed
M&L for in replacement sub main wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC conduit concealed in wall of required size of 25 mm with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc after including taking down unserviceable if reqd all as specified and directed.
M&L for in replacement sub main wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0sqmm (Nominal area) drawn through in and including PVC conduit concealed in wall of required size of 25mm with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc after incl down unserviceable if reqd complete all as per specified and directed.
S&F for in repair/replacement switch piano flush button single pole one way, 6 Amps, 240 Volt including taking down unserviceable complete all as per specified and directed.
S&F for in repair/replacement socket outlet 2-in-1 5 pin, 6 Amps flush type complete all as specified and directed.
S&F for in repair/replacement switch piano flush button single pole one way, 16 Amps, 230/240 V including taking down unserviceable complete all as specifed and directed.
S&F for in repair/replacement socket outlet 2-in-1 5 pin, 6 & 16 Amps flush type including taking down unserviceable complete all as specified and as directed.
S&F for in repair/replacemnt ceiling rose surface, backelite, three terminal, 240 volts including taking down unserviceable complete all as specified and directed.
S&F for in repair/replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including taking down unserviceable complete all as specified and directed.
S&F for Wall mounted LED batten box type pre coated CRCA body suitable for retrofit LED tube rod 18/20 Watt fixed in repair including taking down unserviceable complete all as specified and directed.
S&F for LED self ballasted LED retrofit tube lamp 18 Watt with thermoplastic body min 1800 system lumens and builtin surge protection of 2.5 KV including taking down unserviceable complete all as specified and directed.
S&F for Wall mounted mirror light LED fitting self ballasted LED batten extruded thermoplastic body with PC diffuser in unique square shaped 10 /12 watt 2 Feet long CCT 6500K fixed in repair including dismantling taking down unserviceable fitting any type complete all as specified and directed.
S&F for surface mounted LED bulk head 10 watt luminaire with ABS body & polycarbonate diffuser IP 65 including connecting to ceiling rose with 0.5 sqmm two core copper flexible conductor cable fixed in repair incl lamp including taking down unserviceable complete all as per specified and directed.
S&F for self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) including dismantling taking out unserviceable CFL/LED Bulb complete all as specified and directed.
S&F for slim panel size 2'X 2', 40 watt recess/Surface mounted edge lit LED slim panel having white powder coated extruted aluminium body wiht high quality LGP and PMMA diffuser, separate HPF driver suitable for Armstrong and grid ceiling separate accessoried for recess/surface mounting PCGLP 2 X2, CCT 4000K fixed in repair including dismantling taking out unserviceable one of any make/size complete all as per specified and directed.
S&F for building security LED light 25 Watt energy saving LED ASTRA NEO street light made up of pressure dia cast housing with toughened glass and high power LEDs with option of secondary optic with IP66 protection, efficacy : 110LM/W one GI medium grade 25mm dia bracket of total lenghth 50 cm incl 2 Nos MS Clamp and fastners after dismantling taking down unserviceable one complete all as per specified and directed.
S&F for MCB DB TPN 4 way double door, IP 42, CRCA sheet powder coated vertical type factory made suitable for incorporating MCB as out going and MCB as incoming including connecting incoming and outgoing cables & blaking plate as required including taking down existing unserviceable DB of any size and making good distrubed surface to match with existing complete all as specified and directed. Note:-Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble.
S&F for MCB DB SPN 8 way double door, IP 42, CRCA sheet powder coated factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blaking plate as required including taking out existing unserviceable DB of any size and making good disturbed surface to match with existing including taking down unserviceable complete all as specified and directed. Note:-Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble.
S&F for MCB TPN 100 Amps, 10 KA 415 Volt, 50 Hz, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. Note:-Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble.
S&F for MCB SPN 32 Amp to 40 Amp, 10 KA, 240 volts, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and directed. Note:-Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble.
S&F for MCB SP 6 Amp to 32 Amp 10 KA, 240 volts, IS/IEC 60898-1, 'C' curve including taking down unserviceable complete all as specified and as directed. Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble.
S&F for single pole and neutral enclosure with a two pin and earth plug and socket board with IS 13032, IS 8623 complete with one single pole 20 Amp MCB complete Including dismantiling taking out unserviceable complete all as specified and directed.
S&F for Heating Element ISI Marked round/ tringular base, push type or thread type including rubber washer for 1.5/2.0 KW suitable for geysers 25 Ltrs to 50 Ltrs capacity (as per existing sample) including taking down unserviceable complete all as specified and as directed.
S&F for thermostat ISI Marked suitable for geysers 25 to 50 Ltrs capacity (as per existing sample) including taking down unserviceable complete all as specified and as directed.
S&F for Chromium plated connections 45cm long for Hot/Cold water of 15mm size with cromium nuts and washsers fixed as in repairs complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B-1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to centre both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C-1 , for pit cover including testing on completion complete all as specified and directed. Note:-After completion of work if desired test result is not obtained the earthing is to be redone without any extra cost to deptt.
M/S Trilok chand sharma
Varindera And Varindera Construction
Vishal Builder
R B TRADERS
Joginder Singh and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .