Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.0 L+₹3.1 L (25.9%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.0 L+₹3.1 L (26.0%)Rejected-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical NA due to firm is not enlisted in appropriate cat c(v). |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
13 Feb 2021, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
REPAIR/MAINTENANCE OF MECHANICAL LAUNDRY AT CHAF BANGALORE
2021_MES_410899_1
87411CWEAFNBAN
Open Tender
Miscellaneous Works
Item Rate
330 days
GE AF BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF BANGALORE
₹24,000
Yes
12 Mar 2021
8 Jan 2021
15 Feb 2021
8 Jan 2021
13 Feb 2021
2 Feb 2021
9 Jan 2021 - 23 Jan 2021
Amount
Comprehensive maintenance and reparing/servicing of undermentioned Machines of Mechanical Laundry unit including cleaning, oiling ,greasing ,painting and carrying out routine check of the machine safety devices, relays, control switch gears, alarms , repair /replacement of wornout parts/defective minor spare such as screws ,nut,bolt ,washers ,contactor contacts ,contactor coils ,burnt wires ,lugs ,switches ,plug top ,complete for smooth functioning all as per manufacturer's instructions and all as specified and directed by Engineer-in-charge. Make : Ramson (a) Horizontal washing machine of 50 Kg capacity - 02 Nos (b) Direct drive Hydro Extractor of 30 Kg capacity top loading - 02 Nos (c) Tumble drier of 50 Kg capacity front loading type - 02 Nos (d) Flat bed press of size 750 mm x 1500 mm with auto timer release and programmable temperature control, dry ironing top including compressor - 01 No (e) Washer extractor of capacity 35 Kg vertical type - 01 No (f) Vacuum ironing table of size 1300mm x 800 mm - 02 Nos (g) Flat work ironer(steam heated) of roller length of 1600 mm dia of 600 mm - 01 No
Comprehensive maintenance and reparing/servicing of Boiler of 300/400 Kg/hour capacity of Mechanical Laundry unit including cleaning , oiling,greasing ,arresting leakages in heat exchanger coil&steam pipe lines ,painting of boiler and water tank and carrying out routine check of the machine safety devices, relays,pressure gauges , control switch gears, alarms, fuel pump, water pump, softener, burner, photo cell sensor , NRV, PRV including control valves , repair /replacement of wornout parts/defective minor spare such as screws ,nut,bolt ,washers ,contactor contacts ,contactor coils ,burnt wires , lugs complete for smooth functioning all as per manufacturer's instructions and all as specified and directed by Engineer-in-charge. Make : Ramson Note for Sl No 1 & 2 : - i) The Deptt will handover laundry unit in working condition as is what is basis to the firm. The firm shall have a visit to the site before their quotings and firm is responsible to handed over back laundry unit to Deptt in operational condition in all respects while issue of completion certificate by Deptt to firm. (ii) The comprehensive maintenance quoted amount is included for Material and Labour for all consumable items, spar parts excluding spare parts (Supply only) here-in-after mentioned during the comprhensive maint period. (iii) The quoted firm is responsible to purchase spare parts from original manufacturers/auth distributor/dealer only and GST vouchers to be encl with payment claims. iv) Maintaining the unit at good working condition & desired condition complete allas directed. v) All instruments, tools & plants and equipments etc required to clean/check/ repairs to be provided by contractor. (vi) A record of repairs carried out in each visit of Laundry installation to be maintained separately duly signed by Contractor, JE and Engineer-in-charge. The maintenance certificate duly signed by contractor and concerned JE E/M and Engineer-in-Charge seperately of Mechanical Laundry unit every month. (vii) The contractor to collect the complaint register daily and on completion/rectification of complaint the register will be updated and signed, The firm should provide suitable competent number of Skilled mechanics and If any laundry unit unserviceable at site, within 1 hr the mechanic should attend the complaint and the complaint to be resolved without any further delay. In case the problem could not be solved due to want of spares etc the matter to be informed to the contractor as well as to the concerned JE / AGE E&M. (viii) If the firm failed to provide Skilled Mechanics as per fault at the time of any unit Complaint a recovery @ of Rs.300/- per hour will be recovered from the Contractors dues wef the time of lodging of the complaint to till next/ completion of 24 hrs Also in case of any unit repair for want of spares the Contractor should provide the spare parts in time or with in 24 hours the unit should be made serviceable failing which a sum @ of Rs.500/- per hour wef the time after 24 hours shall be recovered from the Contractors dues. (ix) The Contractor should keep all the spare parts intact for the laundry units in the installation. (x) The firm is responsible to purchasce spare parts as required for day to day comprehensive maint shall be procured from original manufacturers/auth distributor/dealer only and the GST vouchers to be submitted to Deptt while claiming payments.
Supply only brozone steam line stop valve of 50 mm dia ISI marked complete all as directed by Engineer in charge.
Supply only brozone steam line stop valve of 40 mm dia ISI marked complete all as directed by Engineer in charge.
Supply only brozone steam line stop valve of 25 mm dia ISI marked complete all as directed by Engineer in charge.
Supply only brozone steam line stop valve of 15 mm dia ISI marked complete all as directed by Engineer in charge.Make for Sl No. 3 to 6 :- Leader/Soma/Zoloto/sant.
Supply only Copper radiator 950x530x200 mm 4 Rows complete all as directed by Engineer in charge.
Supply only Cone Bush suitable for 30 Kg hydro Extractor complete all as directed by Engineer in charge.
Supply only Diode Bridge rectifier 40A complete all as directed by Engineer in charge.
Supply only Hydro Spring complete all as directed by Engineer in charge. Make for Sl No. 7 to 10 : Ramson or Equivalent as approved by OEM
Supply only V-Belt, B-86 ISI marked complete all as directed by Engineer in charge.
Supply only V-Belt, B-62 ISI marked complete all as directed by Engineer in charge.
Supply only V-Belt, B-63 ISI marked complete all as directed by Engineer in charge.
Supply only V-Belt, B-42 ISI marked complete all as directed by Engineer in charge.
Supply only V-Belt, B-75 ISI markedcomplete all as directed by Engineer in charge. Make for Sl No. 11 to 15 : Fennar/Continental/Pix/Shakthi or Equivalent as approved by OEM
Supply only Hydro Rubber Gasket Kit complete all as directed by Engineer in charge. Make : Ramson or Equivalent as approved by OEM
Supply only A1D1 timer for Boiler of 400 Kg of capacity complete all as directed by Engineer in charge. Make : EAPL/L&T /ABB/Siemens.
Supply only Burner controller for maintain steam pressure, temperature and heater control complete all as directed by Engineer in charge. Make : Ramson/Siemens or Equivalent as approved by OEM
Supply only Water pump seal for washing machine complete as per site requirements all as directed by Engineer in charge.
Supply only Photo Cell complete all as directed by Engineer in charge. Make : Photon or Equivalent as approved by OEM
Supply only Pressure Switch for boiler, washing machine complete as per site requirements all as directed by Engineer in charge. Model-NMA H15CB10 of make Orient or Equivalent as approved by OEM
Supply only Water level sensor complete all as directed by Engineer in charge.
Supply only Low Pressure Switch for washing machine ,boiler complete all as directed by Engineer in charge.
Supply only Water level relay, for washing machine complete all as directed by Engineer in charge.
Supply only Low water switch for extractor,washing machine,boiler complete all as directed by Engineer in charge. Make for Sl No. 22 to 25 - Bharat Thermotechnics or Equivalent as approved by OEM
Supply only Coupling spider for blower motor of boiler complete all as directed by Engineer in charge.
Supply only Piston wall seat assembly for boiler pumping unit complete all as directed by Engineer in charge. Make for SlNo 26 & 27 - Ramson or Equivalent as approved by OEM
Supply only water softner resin complete all as directed by Engineer in charge. Make : ION Exchange or Equivalent as approved by OEM
Supply only Bearing for water pump, washing machine , hydro extractor , sluce machine , flat iron rollers complete all as directed by Engineer in charge. Make- NBC/SKF /KSP/Crompton Greaves.
Supply only Shaft for water pump of any size complete all as directed by Engineer in charge. , Make-Ramson or Equivalent as approved by OEM
Supply only TDS water testing digital meter kit complete all as directed by Engineer in charge. Make : HTC/Phoenix/HM
Supply only suitable chemical for online de-scaling of Boiler heat exchanger coil complete all as directed by Engineer in charge.
Supply only suitable chemical for online de-scaling of steam pipe line circuit complete all as directed by Engineer in charge. Make for SlNo. 32 & 33 - Ramson or Equivalent as approved by OEM
Material and Labour servicing and rewinding of Vacuum pump of 2 HP capacity including cleaning ,varnishing,greasing ,transportation replacement of wornout bearings/bushes complete all as directed by Engineer in charge. Note - The item to be issued to firm by JE E/M for rewinding works through proper gate pass duly signed by Engineer-in-charge.
Supply only Digital temperature controller with probe for boiler complete all as directed by Engineer in charge. Make : Selec/Thermax or Equivalent as approved by OEM
Supply only Mechanical Timer for boiler complete all as directed by Engineer in charge. Make : L & T / Schnider /Siemens/Havells.
Supply only Forward/reverse timer for boiler control panel complete all as directed by Engineer in charge. Make : Selec/L&T /Schnieder/Siemens.
Supply only Push Button Red for boiler control panel complete all as directed by Engineer in charge. Make : TEKNIC/L&T/Havella/Leader.
Supply only Push Button Green for boiler control panel complete all as directed by Engineer in charge. Make : TEKNIC/L&T/Havella/Leader.
Supply only Contactor 18 Amp 230V @50 Hz AC 3/4 pole with auxallary contacts as existing frame size for laundry machines/boiler control panel complete all as directed by Engineer in charge.
Supply only Contactor 25 Amp 230V @50 Hz AC 3/4 pole with auxallary contacts as existing frame size for laundry machines/boiler control panel complete all as directed by Engineer in charge.
Supply only Contactor 32 Amp 230V @50 Hz AC 3/4 pole with auxallary contacts as existing frame size for laundry machines/boiler control panel complete all as directed by Engineer in charge.
Supply only Contactor 9 Amp 230V @50 Hz AC 3/4 pole with auxallary contacts as existing frame size for laundry machines/boiler control panel complete all as directed by Engineer in charge. Make for Sl No. 40 to 43 - SIEMENS/Havells/Schinider/L&T /ABB
Supply only MCB 4 pole 32 Amp 10KA "C'' curve 415 V AC @ 50/60 hz complete all as directed by Engineer in charge.
Supply only Bearing P-210 for V-groove motor driven pulley for washing/drier machine complete all as directed by Engineer in charge.Make : SKF/NBC/KSB/Kirloskar .
Supply only MCP Relay 230 V @ 50 hz 3/4 way NC/NO auxallary contacts as existing type for sluice machine control panel complete all as directed by Engineer in charge. Make - Bharat Thermotechnics or Equivalent as approved by OEM
Supply only Gland rope 12 mm for steam line pump of boiler complete all as directed by Engineer in charge.
Supply only Micro Switch for steam iron of model no:2128 complete all as directed by Engineer in charge. Make - Bharat Thermotechnics or Equivalent as approved by OEM
Supply only Teflon insulation for steam iron of mechanical laundry complete all as directed by Engineer in charge.
Supply only Steam solenoid valve 1/4" size for iron bed machine complete all as directed by Engineer in charge. Make : ALCON/BOSCH or Equivalent as approved by OEM
Supply only Heating coil steam iron 900W for iron press of model No: 2128 complete all as directed by Engineer in charge.Make : AMTECH or Equivalent as approved by OEM
Supply only Steam hose pipe suitable for steam line for mechanical laundry complete all as directed by Engineer in charge.Make : Ramson or Equivalent as approved by OEM
Supply only 4 Core 4 Sqmm cotton breaded copper cable for mechanical laundry machines complete all as directed by Engineer in charge.Make : Havells/Polycab /Plaza/Finlex/Anchor.
Supply only Door limit switch for mechanical laundry complete all as directed by Engineer in charge. Make : Vaishnav/Telemechanic or Equivalent as approved by OEM
Supply only Emergency stop switch for mechanical laundry complete all as directed by Engineer in charge. Make : VASHIO/L&T or Equivalent as approved by OEM
Supply only Brake timer for hydro extractor mechanical laundry complete all as directed by Engineer in charge. Make : Cutler/Selec or Equivalent as approved by OEM
Supply only Transformer for hydro extractor mechanical laundry complete all as directed by Engineer in charge. Make : Vaishnav/Telemechanic or Equivalent as approved by OEM
Supply only Drain valve 15mm for hydro extractor of mechanical laundry complete all as directed by Engineer in charge.Make : Leader/SANT/Precision/Taurus /Zoloto/Soma.
Supply only Nominal dia 15 mm carbon steel Seamless Pipe of thickness 3mm with acessories like bend,coller,elbow and T and complete connected items complete all as directed by Engineer in charge. Make :- Jindal/Tata/Zenith/Prakash/Swastik.
Supply only Nominal dia 25 mm carbon steel Seamless Pipe of thickness 3mm with acessories like bend,coller,elbow and T and complete connected items complete all as directed by Engineer in charge. Make : Jindal/Tata/Zenith/Prakash/Swastik.
Supply only Nominal dia 40 mm carbon steel Seamless Pipe of thickness 3mm with accessories like bend,coller,elbow and T and connected items complete all as directed by Engineer in charge. Make : Jindal/Tata/Zenith/Prakash/Swastik.
Supply only pressure pump of steam generator complete all as directed by Engineer in charge. Make : Ramson or Equivalent as approved by OEM
Supply only 01 Hp motor complete all as directed by Engineer in charge. Make : Kirloskar/Crompton /Jyoti/KSB.
Supply only MS pipe flange 20 mm bore complete all as directed by Engineer in charge.
Supply only MS pipe flange 25 mm bore complete all as directed by Engineer in charge.
Supply only Brozone NRV 25 Nominal Bore with all accessories complete all as directed by Engineer in charge. Make : Kirloskar/Leader/Sant/L&T/Upadhyay.
Supply only Bronze Y strainer 25 Nominal Bore complete all as directed by Engineer in charge. Make : Zoloto or Equivalent as approved by OEM
Supply only Rock wool insullation with aluminium clading of best quality for the steam pipe lines complete all as directed by Engineer in charge.
Supply only Gun metal pressure reducing valve 25mm for sluice machine complete all as directed by engineer in charge. Make : Leader/Zoloto/Gem/SANT/SEIKO.
Supply only Gun metal steam safety valve screwed end 25 mm complete all as directed by Engineer in charge. Make:-Leader/Zoloto/Gem/SANT/SEIKO.
Supply only full face gasket 20 mm for washing machine complete all as directed by Engineer in charge. Make : Ramson or Equivalent as approved by OEM
Material and Labour Repair/Rewiring using proper colour code wires (R,Y,B for phase, Black for Neutral and Green for earth wire) of control pannel for replacement of burnt out wires, thimbels, terminal blocks etc with suitable multistranded FRLS copper wire of suitable size with proper lugs for Sluice machine complete all as directed by engineer in charge Loc : Command Hospital Mechanical laundry Unit
Material and Labour Repair/Rewiring of control pannel for replacement of of burnt out wires, thimbels, terminal blocks etc with suitable multistranded FRLS copper wire of suitable size with proper lugs (Boiler, water purifier, Dryier and steam ironing machine complete all as directed by engineer in charge Loc : Command Hospital Mechanical laundry Unit
Material and Labour in replacement of Steam boiler Heat exchanger coil made out of seamless steel tubing of grade (SS302) dia 25mm , thickness min 3mm is bend as per existing size with mounting brackets includind leakage test with all accessories complete all as directed by engineer-in-charge. Note - The Engineer-in-charge and JE E/M are responsible to carried out photography before executing the item (Then), during executing of the item (Running work) and after executing of the item (Now) and the same to be encl during payment claims. Loc : Command Hospital Mechanical laundry Boiler
Material and Labour in replacement of steel water tank on existing steel structure have a water holding capacity 2000 Liters made out of Mild steel Fe 410-W (Gde-E- 250) quality-A of 3mm thickness by cutting ,bending, revitting, welding, grinding etc , including sight glass water level indicator,inlet /outlet connection , painting of water tank & structure with anti corrosive syntethic enamel paint of two coats by spray painting over a coat of primer cmplete all as directed by Engineer-in-charge. Note - The Engineer-in-charge and JE E/M are responsible to carried out photography before executing the item (Then), during executing of the item (Running work) and after executing of the item (Now) and the same to be encl during payment claims. Loc : Command Hospital Mechanical laundry Boiler Unit
Supply only Flat iron Nylon belt ISI marked as per site requirements complete all as directed by Engineer-in-charge. Loc : Command Hospital Mechanical laundry Flat Iron. Make : Ramson or Eqivalent
Material and Labour for painting of oil fired steam Boiler and steam pipe lines complete with high heat resistance paint of two coats over a coat of primer by preparing old surface by scrapping ,chipping old rust,etc as per IS 1477 Part-II-1971 complete all as directed by Engineer-in-charge. Note : 1. The Engineer-in-charge and JE E/M are responsible to carried out photography before executing the item (Then), during executing of the item (Running work) and after executing of the item (Now) and the same to be encl during payment claims. 2. Loc : Command Hospital Mechanical laundry Boiler
shakti engineering and electrical works
Leo Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .