Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC H NO 145 SAINIK NAGAR RAIBAREILLY ROAD TELIBAGH LUCKNOW 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹21.9 L+₹93,582 (4.47%)Rejected-Finance 149 KHAJURI HARIDWAR UTTARAKHAND 247668 | HARIDWAR | UTTARAKHAND | 247668 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹23.0 L+₹2.0 L (9.70%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹23.9 L+₹2.9 L (14.0%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹24.9 L+₹3.9 L (18.7%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
9 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER DAMAN
Garrison Engineer Daman, Tat RakshakVihar, Dalwada, Nani Daman Post, Daman (UT) PIN396210
PROVISION OF COMMON PARKING SHED AT VARIOUS PLACES IN TRV AREA AT ICGAS DAMAN
2024_MES_650374_2
8791/E8
Open Tender
Civil Works
Works
180 days
DAMAN
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹57,000
3 Sept 2024
11 Jun 2024
11 Jul 2024
11 Jun 2024
9 Jul 2024
25 Jun 2024
Amount
Demolition of brick or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles all as specified and as directed.
Dismantling of stone sett/interlocking paver tiles of any description or thickness laid dry or laid dry and pointed all as specified and as directed.
Excavation in post holes (or similar holes) each n exc 0.5 Cum, getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25cm, getting out soft/loose soil etc. complete all as specified and directed.
Excavation over areas not exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material exc. 250 m but not exceeding 500m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L for hardcore of gauge not exc 63mm, using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick each layer, watered and rammed to a true surface, complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete including all as specified and as directed.
M&L for 15mm thick rendering in CM 1:4 on brick/concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
M&L 100 mm thick cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate as sub base including form work if required complete all as specified and as directed.
M & L for plates (plain or chequerred) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W(Gde 250) Quality -A all as specified and as directed.
S&F Steel work in tubular trusses or hollow section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 including necessary welding complete all as specified and directed.
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment over and including 50mm thick crushed stone sand cushioning all as specified and as directed.
M & L for cement concrete 1:2:4 tye B-1 (using 20mm graded stone aggergates) as in kerb or coping and the like round or chamferred on edge including necessary form work complete all as specified and directed.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws compllete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked 1100 volts grade, single core multistranded copper conductor cable drawn through and including PVC conduit of size 20 mm dia or above as required at site with all accessories such as Tee ,Corner, overlaping connector etc.along the suface of walls/roofs/ ceilings/floors etc including concealed PVC box for fixing of and including modular plate as per no of switch modules flush mounted suitable for fixing modular switches , sockets,fan regulators etc.including modular plate cover of required size with necessary stainless steel cadmium plated screws and including 1.5 Sqmm PVC insulated, multistranded, FRLS type,unsheathed(Green colour),single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and directed for One light point controlled by one switch.
Supply & fixing modular type switch 6 Amps ,1way,1 module.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body
Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fix factory made, sheet metal enclosure, single door, 240 volts, AC,SPN, vertical distribution board, 2 way, painted with epoxy based powder coated suitable for mounting MCB as incomer of rating upto 40Amps, FP, 16-36 KA and MCB SP /TP as outgoings and complete with and including 200 amps rated copper busbar, neutral bar, earth bar, connecting cable links with and including top and bottom removable gland plate, complete with IP 43 protection, all as specified and as directed.
Supply & fix MCB SPN 32 Amps 10 KA,"C" series complete all as specified and directed.
Material and labour for submain wiring using proper colour code with two runs of single core, 1100 volts grade PVC insulated FRLS, ISI marked, unsheathed (flexible) multistaranded copper conductor cable of size 4 sqmm and one run of single core, 1100 volts grade, PVC insulated FRLS, ISI marked unsheathed (flexible) multistranded copper conductor of size 4Sqmm drawn through and including PVC conduit medium grade of 25mm dia ISI marked with conduit accessories concealed in wall/ceiling/roof/column/beam etc complete all as specified and directed.
M/s Himanshu Tyagi
NATH CONSTRUCTION
Harsh Infrastructure
SHRI SIDHI VINAYAK ENTERPRISES
KML CONSTRUCTION
Parmatma Enterprises
NEW BHARAT ENGINEERING AND CONSTRUCTION CO
Nitesh Enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .