Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.0 L+₹7.0 L (18.8%)Rejected-Finance C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | L2 | Rejected-Finance Being L2 |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
15 Dec 2022, 6:00 pmClosed
CWE Patiala
HQ CWE, Bldg No 26, New Lal Bagh Patiala 147001
PROVN OF ROOM FOR ARMD WORKSHOP AND PROVN OF COVERED SHED FOR ARMD REGT AT MIL STN PATIALA UNDER GE SOUTH PATIALA
2022_MES_564179_1
8322/PAT/T-44/2022-23
Open Tender
Civil Works
Lump-sum
180 days
Patiala
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE South Patiala
₹82,000
Yes
12 Jan 2023
19 Nov 2022
17 Dec 2022
19 Nov 2022
15 Dec 2022
3 Dec 2022
19 Nov 2022 - 26 Nov 2022
Amount
Schedule 'A'Section-I (Building Works)
Total amount of Sch 'A' Sec I (Building Works)
Schedule 'A'Section-II (EXCAVATION AND EARTH WORKS)
Total amount of Sch 'A' Sec II (Excavation and Earth Works)
Schedule 'A'Section-III (INTERNAL ELECTRIC SUPPLY)
Total amount of Sch 'A' Sec III (Internal Electric Supply Works)
Schedule 'A'Section-IV (EXTERNAL WATER SUPPLY)
Total amount of Sch 'A' Sec IV (External Water Supply Works)
Schedule 'A'Section-V (ROAD/PATH)
Total amount of Sch 'A' Sec V (Road/Path Works)
Schedule 'A'Section-VI (AREA DRAINAGE)
Total amount of Sch 'A' Sec VI (Area Drainage Works)
Schedule 'A'Section-VII (INTERNAL WATER SUPPLY)
Total amount of Sch 'A' Sec VII (Internal Water Supply Works)
Schedule 'A'Section-VIII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duty required size with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charg Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.iii) Neccessary cutting chasing wherever required shall be part of job at no extra cost.
One light/bell/fan point (ceiling/wall/exhaust) controlled by one 1-way switch or 1-one way switch and regulator
One 3/5 pin socket outlet, 5/6 Amp on independent board
All as per Ser No 9 above but one socket outlet 3 pin 15 Amp independent with 2.5 Sqmm wire including 1.5 Sqmm PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor complete
Modular switch one way 6 Amp, 240 Volts,1 module complete all as specified and as directed.
Modular switch one way 16 Amp, 240 Volts,1 module complete all as specified and as directed.
Modular socket outlet 6 Amp, 2/3 Pin combined 2 module complete all as specified and as directed.
Modular socket outlet 6/16 Amp, 2/3 Pin combined 2 module complete all as specified and as directed.
Modular Fan regulator, step type, 120W, 2 module complete all as specified and as directed.
Ceiling rose surface bakelite tow to three terminal 65x50mm complete all as specified and as directed.
MCB DB TPN4 way with sheet metal enclosure 415 V double door complete all as specified and as directed.
MCB TPN, 16 KA , 4 pole 63 Amp, 415 V complete all as specified and as directed.
MCB SP 240 V, 6 to 32 Amps C series 10 KA complete all as specified and as directed.
MCB DB, SPN, 8 way acrylic door complete all as specified and as directed.
MCB SPN, 240V 40-63 Amps C series 10 KA complete all as specified and as directed.
M & L for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate not less than 1.50 m below ground level connected to GI earth wire 4mm dia by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit, RCC cover (1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel TMT bar 15cm c/c and suitable handle of 10 mm Dia round bar, charcoal & common salt filled in alternate layers funnel with 20mm bore medium grade watering pipe, 15mm dia GI pipe light grade for protection of earth lead, wire mesh and connected to earth point including testing complete all as specified and shown in electric plate No 3 of SSR part I.
S&F ceiling fan complete with all accessories 230 V, 1200mm sweep complete all as specified and directed.
Supply & fix LED light fitting with new technology ultra bright led tubelight with aluminium heat sink & polycarbonate diffuser having high efficiency of capacity 20 watt including box type batten pre coated CRCA body heavy duty including necessary electric connection from ceiling rose to connector with suitable size of cable complete all as specified and as directed. Make : Cat Part No LHEXACP7IN1W020 of Havells or equaivalent in makes as per Appendix 'B'.
New generation energy saving and environmental friendly long life LED building security light 1 x 25 watts made up of pressure die cast aluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate drive compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable braket with 32mm bore light grade GI pipe bend to shape, including MS clamp of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fitting complete all as specified and as directed. Make : Cat Part No PUB0506109 of POLYCAB or equaivalent in makes as per Appendix 'B'.
Supply and laying 16 Sqmm 4 core cable XLPE/PVC insulated armoured and shethed LT 1100 volts grade with aluminium conductor complete all as specified and as directed
Supply and laying 10 Sqmm 2 core cable XLPE/PVC insulated armoured and shethed LT 1100 volts grade with aluminium conductor complete all as specified and as directed
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified and as directed. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I.
M&L for machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS : 15658-2006 of 60 mm thickness, M-35 grade with 6mm top layer of anti abrasive material, including filling of interstices with fine sand laid over and including 25 mm thick (compacted) fine sieved sand cushioning complete all as specified and as directed.
M&L for machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS : 15658-2006 of 80 mm thickness, M-40 grade with 6mm top layer of anti abrasive material, including filling of interstices with fine sand laid over and including 25 mm thick (compacted) fine sieved sand cushioning complete all as specified and as directed.
Cutting of existing pipe line size 50 to 80 mm bore for taking out connection of 25 mm dia pipe including all necessary fittings and fixture complete all as specified and as directed.
M/S Mukesh Kumar Gupta
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .