Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Bidder is technically rejected |
| 4 | Rejected-Technical | Rejected-Technical Bidder is technically rejected |
| 5 | Rejected-Technical 5 GANESH BHAVAN SV LANE 3RD CROSS CHICKPET CHICKPET BANGALORE KARNATAKA 560053 | BENGALURU URBAN | KARNATAKA | 560053 | Rejected-Technical Bidder is technically rejected |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
22 Dec 2022, 5:30 pmClosed
Senior Manager (P and C)
Kiru HE Project, Chenab Nagar-II, Kishtwar
Purchase of MCCBs, MCBs, Changeovers and Fuses for R and M of Administrative and Residential Buildings of Kiru HEP at Kishtwar and Kiru Site.
2022_CVPP_716572_1
CVPPPL/Kiru/SM(P and C)/PKG P-08/2022-23/275
Open Tender
Electrical Goods/Equipment
Supply
60 days
Kiru HEP Stores at Kishtwar
As per Tender Document
2 documents required · 2 mandatory
₹590
Yes
Kiru HEP, CVPP (P) Ltd.
₹12,000
Yes
23 Mar 2023
7 Oct 2022
28 Dec 2022
7 Oct 2022
22 Dec 2022
7 Oct 2022
Amount
Heavy Duty Double Break Fuse Switch-Hbc Fuse Type 63 Amp 415 V 50 Hz 3 Pole And Neutral Standard Conformity Is / Iec: 60947 - 1&3 Switches Are Surface Mounting Type Housed In Sheet Steel Enclosure With Side Handle Operation And Have Front Access Left Opening Doors Interlocked To Prevent Opening When The Switch Is In On Position. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
Heavy Duty Double Break Fuse Switch-Hbc Fuse Type 100 Amp 415 V 50 Hz 3 Pole And Neutral Standard Conformity Is / Iec: 60947 - 1 &3 Switches Are Surface Mounting Type Housed In Sheet Steel Enclosure With Side Handle Operation And Have Front Access Left Opening Doors Interlocked To Prevent Opening When The Switch Is In On Position. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
Heavy Duty Double Break Fuse Switch-Hbc Fuse Type 160 Amp 415 V 50 Hz 3 Pole And Neutral Standard Conformity Is / Iec: 60947 - 1&3 Switches Are Surface Mounting Type Housed In Sheet Steel Enclosure With Side Handle Operation And Have Front Access Left Opening Doors Interlocked To Prevent Opening When The Switch Is In On Position. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
Heavy Duty Double Break Fuse Switch-Hbc Fuse Type 200 Amp 415 V 50 Hz 3 Pole And Neutral Standard Conformity Is / Iec: 60947 - 1&3 Switches Are Surface Mounting Type Housed In Sheet Steel Enclosure With Side Handle Operation And Have Front Access Left Opening Doors Interlocked To Prevent Opening When The Switch Is In On Position. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCCB- 125 AMP 4P 415 V 50 HZ Rated Ultimate Short-Circuit Breaking Capacity Ics=100% Icu at 415 Vac(kA rms) 36 KA Type Of Release -Thermomagnetic Adjustable Type Overload Setting - Adjustable (80-100)% Thermal and Fixed Magnetic Setting Rated Insulation Voltage Ui: 1000 V, Rated Operation voltage Ue: 690 V. Depicts the ON/OFF status of the breaker. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCCB- 160 AMP 4P 415 V 50 HZ Rated Ultimate Short-Circuit Breaking Capacity Ics=100% Icu at 415 Vac(kA rms) 36 KA Type Of Release -Thermomagnetic Adjustable Type Overload Setting - Adjustable (80-100)% Thermal and Fixed Magnetic Setting Rated Insulation Voltage Ui: 1000 V, Rated Operation voltage Ue: 690 V. Depicts the ON/OFF status of the breaker. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCCB- 200 AMP 4P 415 V 50 HZ Rated Ultimate Short-Circuit Breaking Capacity Ics=100% Icu at 415 Vac(kA rms) 36 KA Type Of Release -Thermomagnetic Adjustable Type Overload Setting - Adjustable (80-100)% Thermal and Fixed Magnetic Setting Rated Insulation Voltage Ui: 1000 V, Rated Operation voltage Ue: 690 V. Depicts the ON/OFF status of the breaker. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCCB- 250 AMP 4P 415 V 50 HZ Rated Ultimate Short-Circuit Breaking Capacity Ics=100% Icu at 415 Vac(kA rms) 36 KA Type Of Release -Thermomagnetic Adjustable Type Overload Setting - Adjustable (80-100)% Thermal and Fixed Magnetic Setting Rated Insulation Voltage Ui: 1000 V, Rated Operation voltage Ue: 690 V. Depicts the ON/OFF status of the breaker. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCCB- 400 AMP 4P 415 V 50 HZ Rated Ultimate Short-Circuit Breaking Capacity Ics=100% Icu at 415 Vac(kA rms) 36 KA Type Of Release -Thermomagnetic Adjustable Type Overload Setting - Adjustable (80-100)% Thermal and Fixed Magnetic Setting Rated Insulation Voltage Ui: 1000 V, Rated Operation voltage Ue: 690 V. Depicts the ON/OFF status of the breaker. (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- SINGLE POLE 10 AMP , 240 V/415 V, 50 Hz, 10 KAC series,(In accordance with IS/IEC 60898-1). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- SINGLE POLE 16 AMP , 240 V/415 V, 50 Hz, 10 KA C series,(In accordance with IS/IEC 60898-1). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- SINGLE POLE 20 AMP , 240 V/415 V, 50 Hz, 10 KA C series,(In accordance with IS/IEC 60898-1). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- SINGLE POLE 32 AMP , 240 V/415 V, 50 Hz, 10 KA C series,(In accordance with IS/IEC 60898-1). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- DOUBLE POLE 40 AMP , 240 V/415 V, 50 Hz, 10 KA C series,(In accordance with IS/IEC 60947-3). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- DOUBLE POLE 63 AMP , 240 V/415 V, 50 Hz, 10 KA C series,(In accordance with IS/IEC 60947-3). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- TPN 40 AMP , 240 V/415 V, 50 Hz, 10 KA C series,(In accordance with IS/IEC 60947-3). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
MCB- TPN 63 AMP , 240 V/415 V, 50 Hz, 10 KA C series,(In accordance with IS/IEC 60947-3). (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
Sheet steel MCB distribution board , 240/415 Volts on surface/recess complete with tinned copper bus bar, neutral bus bar , earth bar, din bar, interconnections, powder painted including earthing etc.
10Way SPN DB (10+2) IP 43 with metal door (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
12Way SPN DB (12+2) IP 43 with metal door (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
16Way SPN DB (16+2) IP 43 with metal door (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
On load changeover,100 amp,415 V,4 Pole,sheet steel enclosure with side Handle (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
On load changeover,63 amp,415 V,4 Pole,sheet steel enclosure with side Handle (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
Off load changeover,200 amp,415 V,4 Pole,sheet steel enclosure with side Handle (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
Off load changeover,400 amp,415 V,4 Pole,sheet steel enclosure with side Handle (C&S/L&T/SIEMENS/HAVELLS/ABB/ ANY EQUIVALENT)
Kit-kat Rewireable (Porcelain Fuse carrier & Base) 63 AMP,415 V (C&S/L&T/SIEMENS/HAVELLS/ABB/ Bussman/ ANY EQUIVALENT)
Kit-kat Rewireable (Porcelain Fuse carrier & Base) 100 AMP,415 V (C&S/L&T/SIEMENS/HAVELLS/ABB/ Bussman/ ANY EQUIVALENT)
HRC fuse DIN type 100 amp ,415 V,Breaking capacity 120KA (C&S/L&T/SIEMENS/HAVELLS/ABB/ Bussman/ ANY EQUIVALENT)
Master Engineering Services
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .