Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹8.6 L+₹8,984 (1.06%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹9.0 L+₹52,918 (6.22%)Rejected-Finance 0 MADHUPUR SAKARDAHA MADHUPUR SAKARDAHA SARAON MADHUPUR SAKARDAHA ALLAHABAD UTTAR PRADESH 212502 | PRAYAGRAJ | UTTAR PRADESH | 212502 | L3 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
20 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Prabhat Kumar Singh, AGE (I)
AGE (I) Manauri Allahabad-212212
REPAIR / MAINT OF LT DISTRIBUTION NETWORK/ PANELS/ CABLES WITH OTHER CONNECTING WORK IN OLD PROJECT AREA AT 24 ED UNDER AGE(I) AF MANAURI
2020_MES_355838_1
8819/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri, Allahabad
Class E Cat b(i)
7 documents required · 7 mandatory
₹500
AGE (I) Manauri
₹19,800
Yes
13 Oct 2020
21 Jul 2020
24 Aug 2020
21 Jul 2020
20 Aug 2020
6 Aug 2020
60 days
Amount
Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete.
Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete.
Removal of surplus excavated material to a distance n.exc. 50 metre and depositing where directed at a level n.exc. 1.5 metre above starting point complete.
M & L for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete. (Note-Punned thickness ie 180mm will be measured and paid)
M&L for brick protection cover over cable of old size Bricks” laid dry over LT cable width of brick shall be laid across the length of cable) complete all as specified and as directed.
Cutting/boring to plinth protection/hard standing/road etc in suitable depth and crossing of GI pipe of size 80 mm bore so that XLPE underground cable can be passed and giving mechanical protection to cable complete all as specified and directed. Note:- Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existing specification and GI pipe shall be measured and paid separately under respective items.
Disconnecting and taking upto and relaying the same at old/new position XLPE cable in all specification from trenches /duct /pipe including bricks setting aside for reuse or made to schedule of credit as per site required complete all as specified and directed. Note:- (i) Excavation & Earth work shall be measured and paid separately under respective item of this schedule. (ii) New Bricks & sand for cable protection shall be used and shall be measured and paid separately under respective item of this schedule. (iii) Old material i.e. bricks etc shall be contractors property & amount shall be deducted as per schedule of credit.
BLANK
Supply, laid in trench /fixed in replacement by re-routing with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with aluminium conductor 1100 volts, grade cross section area 4 core x 25 Sqmm (earthed) complete all as specified and directed.
All as per item No 9 above but size of cable 3.5 core x 50 Sqmm (earthed)
All as per item No 9 above but size of cable 3.5 core x 70 Sqmm (earthed)
All as per item No 9 above but size of cable 3.5 core x 95 Sqmm (earthed)
All as per item No 9 above but size of cable 3.5 core x 16 Sqmm (earthed)
All as per item No 9 above but size of cable 3.5 core x 10 Sqmm (earthed)
Supply & fixed in replacement 40 MM dia bore GI tubing 'light grade' with fixing accessories laid in trenches or on wall or pole with clamp complete all as specified & directed.
All as per item No 15 above but of 50 mm dia bore
All as per item No 15 above but of 80 mm dia bore
M&L painting to steel prepared surfaces of any width or girth not otherwise described by using synthetic enamel paint in two coats (one as finishing coat) over one coat of red oxide zinc chrome primer on surface of steel structure /girder/ angle frame / wire mesh fencing (both side) / installation board / gate etc in any description at E/M installation using paint spray gun on specified working pressure including sign making /marking with using different colour in given size of letter etc complete all as specified and directed. Note- Paint colour & shade including writing marking of letters etc shall be deemed included in quoted unit rate and the same shall be approved by Deptt.
M & L Painting to existing two/three steel pole structure of 11 mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above planting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 mtr height of pole complete all as specified and as directed. Note : Cutting of bushes & tree branches upto 3 Mtrs height of pole shall be deemed included in quoted unit rate.
All as above item No 19 here in before but single steel tubular pole in 9 /11 Mtrs long.
M & L for earthing complete with galvanized steel earth plate electrode of size 60 CM x 60 CM x 6 MM thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below the ground level) with top edge of earth plate not less than 1.50 Mtrs below normal ground level connected to galvanized earth lead strip 32 x 6 MM size by means of nut, bolts & check nuts and washers of galvanized iron or steel connected to earthing test point complete all as specified or indicated, including earthing pit with PCC 1:3:6 type C 1 using 20 mm graded stone aggregate & RCC cover slab 40 MM thick as in RCC 1:2:4 type B-1 using 20 MM graded stone aggregate, reinforced with 8 MM dia TMT bars @ 150 MM centre to centre both way with two Nos lifting handle, GI pipe 20 MM dia 'light grade' with funnel and wire mesh for watering and 40 MM dia 'light grade' GI pipe for GI earth strip 32 x 6 MM protection etc complete all as shown in electrical plate No. 3 of SSR Part - I (2009) including testing on completion including dismantling of old existing earthing complete all as specified and directed. Note:- Items includes cost of 7.5 metre galvanized earth lead strip 32 x 6 MM.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit / pipes or fixed to pole or any other indicated situation for loop earthing etc for galvanised earth strip 32x6mm including taking down existing strip complete all as specified and directed.
M&L for erection in position of true vertical swaged tubular pole type 410 SP-31 [09 m long] complete with cast iron base plate, finial taper plug, bolts, nuts and screws and top cover complete including taking out old pole any type from ground and making good disturbed surface complete all as specified & directed including following:-
[a] Excavation in trenches not exceeding 1.5 m wide & 2 m deep for pole foundation & getting out soft loose soil, returning filling soil in the trenches after fixing of pole in foundation ramming earth around the layers not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 m. [b] M&L providing PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation 600 mm x 600 mm cross section planting depth 1.8 m for concrete casing the pole up to ground level. [c] M&L providing PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth band/ collar 300 mm high from ground level & 450 mm dia. [d] M&L painting of pole on external surface with one coat of black bituminous paint [up to planting depth] and above plinth band/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of steel surface and painting with synthetic enamel paint blue colour, circular band three number of 30 cm wide in alternate layer up to height of 1.5 m above plinth band of pole. [e] Material & labour writing letter or figures/ pole number [Block, Roman, Italic as Indian] with thick synthetic enamel paint of approved shade not exceeding 30 cm. Note: (i) Old dismantled portion of LT poles in grounds shall be filled with PCC (1:5:10) type E-2 using 40 mm graded stone aggregate. Cost of PCC filling shall be deemed included in quoted unit rate (ii) Rate shall be deemed to include cost of Eearth work, PCC & other work as mentioned here-in before (a) to (e) under this item.
S&F in replacement stay assembly comprising of 7/8 SWG galvanised stay stranded wire in required length fixed between pole and hook with flat iron clamp bolts nut and washer, galvanised 14 MM dia, 400 MM long, stay bow with 19/20 MM dia 215 CM long stay rod with threaded ends, GI nut and washer, GI stay plate 230x 230 x 6 mm thick plate, two nos thimble, MS clamp made out of 50x 6 MM flat iron loop insulator made of 90 MM x 140 MM dia, 25 MM porcelain all as shown in electrical plate No 1 including required excavation/ earthwork and PCC for foundation and coping in size 30 x 30 x 30 CM complete all as specified and as directed. Note: Quoted rate shall deem to be included cost of earth work and cement work.
S&F in replacement of cross arms bracing, supports, clamps and back plate fabricated from structural steel section including nut & bolts, washers, welding, bending, cold or hot, drilling hole for bolts in any shape or size as indicated over and including of two coat of synthetic enamel paint over a coat of primer red oxide complete all as specified and as directed.
S&F in replacement MCCB, 3 pole, 63 Amp rating having breaking capacity of 16 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified aid directed. Make: Legrand Cat part No 420003 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
All as per item 26 above but 4 pole 415 Amps 125 Amps rating having breaking capacity of 16 KA, 415V. Make: Legrand Cat part No 420016 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
S&F in replacement MCCB, 4 pole, 250 Amp rating having breaking capacity of 36 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand Cat part No 420249 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
S&F in replacement MCCB, 4 pole, 160 Amp rating having breaking capacity of 36 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand Cat part No 420097 or equivalent in makes as specified in list of make Appendix 'B' to particular specifications.
Supply, Installation, testing and commissioning of LT Panel in cubical housing cabinet, outdoor type, double door platform mounted (minimum height 45 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet and full built upon angle iron frame in size 40 x 40 x 6 MM, having front and rear hinged both side openable doors and lifting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side openable, gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by suitable size of copper strip in proper colour coding and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase, 4 wire system ,suitable rating CTs and PTs, internal connection should be made by copper strip in suitable rating, making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 6 MM imbedded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate ( minimum 50 CM above GL and 30CM below GL) complete comprising the following items:-
Supply. Installation, testing and commissioning of LT Panel in cubical housing cabinet, outdoor type, double door platform mounted (minimum height 45 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet and full built upon angle iron frame in size 40 x 40 x 6 MM, having front and rear hinged both side openable doors and lifting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by suitable size of copper strip in proper colour coding and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire system ,suitable rating CTs and PTs, internal connection should be made by copper strip in suitable rating, making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 40 x 6 MM imbedded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate ( minimum 50 CM above GL and 30CM below GL) complete comprising the following items:-
Supply. Installation, testing and commissioning of LT Panel in cubical housing cabinet, outdoor type, platform mounted (minimum height 45 cm above normal GL and 30 cm below normal GL) , CPRI approved factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet of overall indicating size 1000 x 900 x 450 MM and full built upon angle iron frame in size 40 x 40 x 6 MM, having front and rear hinged both side openable doors and lifting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase,4 wire system ,suitable rating CTs and PTs . internal connection should be made by copper strip in suitable rating ,making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 6 MM imbedded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate ( minimum 50 CM above GL and 30CM below GL) complete comprising the following items:-
(a) 04 Nos bus bars equal size made out of aluminium conductor strip in colour coating 600 Amps rated mounting on both side heat shrinkable insulators and PVC sleeves. -01 Set (b) LED indicating lamps of 'R' 'Y' and 'B' phase. Set of three -01 (c) Digital volts meter rating 3 phase class 1 - 01 No Make :- L&T (d) Digital Ammeter rating 3 phase 1A class 1 - 01 No Make :- L&T (e) Digital kWh (Energy) Meter rating 3 phase 4 W, 5 A class 1 with RS 485 port - 01 No Make :- L&T (f) MCCB ,125 Amps rated, 4 pole, 415 volts grade , 36 KA breaking capacity microprocessor based operated - 01 No (As main incomer) (g) MCCB ,63 Amps rated, 4 pole, 415 volts grade , 16 KA breaking capacity thermal magnetic based operated - 04 No as outgoing Note : (i) Panel drawing shall be approved by Deptt for size/qty/ Tech specification before placing order (ii) All MCCB shall be confirming to Icu 100% and IEC 60947 -2 . in compact series (iii) All out going feeder shall be connected by cable through suitable size of gland plate/glands. (iv) The various feeder shall be indicated by 50mm size letters in synthetic enamel white paint. Make of MCCB : as per specified in list of make Appendix 'B' to particular specifications.
Supply and fixing in replacement 1100 volts grade heavy duty cable in size 4 Sqmm x 2 Core muilticore conductor PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 Meter apart including 4 MM suspension wire one twin core cable flat or circular for fixing as service connection cable complete all as directed. Make : Finolex / Plaza/ Havells/ Gloster
All as per item No 33 above but size 6 Sqmm X 2 Core
All as per item No 33 above but size 10 Sqmm X 2 Core
All as per item No 33 above but size 16 Sqmm X 2 Core
M&L for cutting, welding, jointing, replacing to hinges with openable door of LT panel in all size/ make / model etc and painted with two coat of synthetic enameled paint in approved colour using paint spray gun with making all as per existing in different colour etc all required at site complete as directed
Supply only Scotch Rubber mastic tape 2228, 2" (50mm minimum) width and 10 feet in length suitable for 11 KV. Make: 3M
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not mentioned in BOQ.
M/S VIJAY SINGH
Avion Industries
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .