door frame metal detector dfmd security metal detector Average Turn Over of Last 3 Years 24 Lakh (s) Experience with Gov. Required 3 Year (s) Door Frame Metal Detector Dfmd Security Metal Detector ( 225 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE/CAPACITY Type of usage Outdoor Outdoor Detection Zones Single Zone Single Zone Function Detects Ferrous
Non- Ferrous and alloy metals concealed in the body of a person when passsed through the arch way * Number of Horizontal Detection Zones covering full Height Single Zone * Capacity/throughput rate (person/min) 30 or more * False Alarm rate (%) 1 * DIMENSIONS/WEIGHT Passage Height 2000 * Passage Breadth 720 * 1/7 Passage Width 600 * Weight of the equipment Not more than 80 Kg * DOOR FRAME CONSTRUCTION Construction of Door Frame (Walk-through Arch) Light weight
rigid
laminated side panels and cross piece with ABS plastic boots for panel protection * Material of Walk- through Arch PVC * Provided with base wheels for easy mobility false * Provided with a floor panel to attach both side panels to give stability & rigidity to the structure true * Ramp over the floor panel - Covered with synthetic carpet for long life false * Water proof true * Weather proof true * DETECTION Metals detectable Ferrous
Non-Ferrous
Ferrite & Alloys * Uniform Detection from top to bottom Yes * Capable of Metal Detection in all orientations Yes * Detect multiple objects of various size
weight and shape in all the zones simultaneously from head to toe Yes * Capable of Metal Detection in walking speed of interception Yes * Performance independent of the speed of person passing through Yes * ALARM/INDICATION DISPLAY Audio-Visual indication on detection at side panels and control panel Yes * Audible Alarm on detection with Yes * 2/7 adjustable volume Bar Display to indicate Metal location w r t Height on person Yes * Audio-Visual Low Battery indication Yes * Back-lit Display LCD * SENSITIVITY Operational Frequencies User selectable * Number of User Selectable frequencies 15 * Adjustable Sensitivity Yes * Number of Sensitivity Levels/Steps 15 * Uniform Sensitivity in all zones Yes * Calibration Both manual and Auto Calibration * SECURITY Provision to secure access to the control unit by a pass word protected alpha numeric keypad Yes * Re-setting after alarm condition Re-set itself (auto) within 3 Seconds * Walk/Stop indicator for traffic control Yes * Control Panel Easy accessible control panel
with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and or by password. * User friendly self- testing diagnostics to identify faulty condition Yes * INTERFERENCE SUPPRESSION REJECTION Automatic synchronization for DFMDs Do not interfere with adjacent installed DFMDs located close to each other upto a distance of 1 * Static Metal Compensation Not affected by heavily Yes * 3/7 reinforced floors/roof tops/walls High discrimination between small masses and personal metallic objects Yes * Not affected by external RF transmission and EMI (Electro Magnetic Interference) Yes * Not affected by by interference
which is mains-borne or radiated by external source Yes * Not affected by the operation of radio
Mobile phones
walkie- talkie sets
X-ray monitors etc within a distance of one meter Yes * Not affected by moving metallic items such as trolleys
opening closing of metallic gate etc
one meter away from the archway Yes * HEALTH & SAFETY Harmless to wearers of pacemakers
defibrillators or other vital support systems
pregnant women and magnetic storage media Yes * Not affected by infrared
ultraviolet
electromagnetic or RF radiation Yes * Conform to international security standards of Safety Radiation Yes * Harmless to magnetic media
electronic devices
Film safe and Data safe Yes * ENVIRONMENTAL Operating Temperature Range (Degree C) Minus 20 to Plus 55 Degree C * Operating Humidity - Non condensing (RH) (%) 95 * 4/7 POWER SUPPLY BATTERY Source of Power Operated by AC mains supply and alternatively by rechargeable battery * Power Supply 220 V +/-10% VAC * Battery Re-chargeable
maintenance free
internal battery with charger * Battery Back-up in full function (hours) 16 * ACCESSORIES One Standard Test Piecec for each machine for testing during commissioning maintenance Inclusive in the scope of supply * Training tools- Charts
slides
training brochure
training work model
blowup diagram
video films on demonstration and use etc Inclusive in the scope of supply * Technical manual giving full description of the item
user's handbook and literature Yes * Practical training 1 Day * Availability of Spares for a period of 7 years after the warranty period true * Ruggedized polypropylene shock proof container compliant to IP 65 or better for safe transportation of the equipment false * WARRANTY Warranty (Years) 3 * CERTIFICATION Availability of Test Report from NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specification true * Test Report Number & Date - * 5/7 Name & address of the Lab - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Deep Kumar Pant 226007
Security Department
413 Dr Baijnath Road
New Hyderabad
225 30