| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹4.8 L+₹13,861.14 (2.96%)Rejected-AOC | L2 | Rejected-AOC Higher side | |
| 3 | L3₹5.0 L+₹29,675.32 (6.34%)Rejected-AOC | L3 | Rejected-AOC Higher side | |
| 4 | L4₹5.5 L+₹78,250.02 (16.7%)Rejected-AOC | L4 | Rejected-AOC Higher side |
Tender Value
₹4.9 L
EMD Value
₹9,900
Closing Date
22 Dec 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director of Lighthouses and Lightships
O/O THE DIRECTORATE OF LIGHTHOUSES AND LIGHTSHIPS, 44 BS ROAD, DEEP BHAWAN, PORT BLAIR
Electrification of Transit accommodation building at Little Andaman, Hutbay
2020_DGLL_594873_1
AN/MQ(2)/2019
Open Tender
Electrical Works
Works
180 days
Little Andaman
As per Tender Document
9 documents required · 9 mandatory
₹0
₹9,900
Yes
Deep Bhawan, Port Blair
26 Apr 2021
5 Nov 2020
24 Dec 2020
5 Nov 2020
22 Dec 2020
5 Nov 2020
5 Nov 2020 - 15 Dec 2020
16 Dec 2020
180 days
Amount
Wiring of light point/fan point/exhaust fan point/call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed with medium class 25mm PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5Sqmm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for twin control light point with 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc. as required
Wiring of light/power plug with 2x4 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class 25mm PVC conduit along with 01 No 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class 25mm PVC conduit as required.
2 x 2.5sqmm + 1 x 2.5sqmm earth wire
2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire
4 x 10.0 sqmm + 2 x 6.0 sqmm earth wire
Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required
Supplying and fixing following modular switch on the existing modular plate and switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16A switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
TV antenna socket outlet
Bell Push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
Supplying and fixing following modular base & cover plate on existing modular metal boxes etc as required.
1 or 2 Module
3 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6A &15/16 A modular socket outlet and 15/16A modular switch, connections etc. as required
Supplying and fixing 3pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.
Supplying and fixing call bell/buzzer suitable for single phase, 230V, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED fittings of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rod of standard length (upto 30cm) with 1.5sqmm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
Upto 450mm sweep
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 02 nos. 3 pin 5/6 A modular socket outlet and 02 nos 5/6A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB, “C” curve including connections, painting etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board/MCB board including drilling holes in panel/DB, making connection, etc. as required
100A, 30KA, FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB DB, Double door 240V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way double door
Supplying and fixing 5A to 32A rating, 240/415V, “C” curve, MCB suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required.
Single Pole
Double Pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
Earthing with G.I earth pipe 4.5mtr long, 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I wire at 0.50 mtr below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Supply of 1200mm sweep ceiling fan with blade, Reputed make
Supply of Light duty Pedestal fan 400mm sweep, 230V, Reputed make
Supply of Surface mounting 1' 10W Sleek LED mirror light provided with high output diffuser, reputed make
Supply of 4-module LED footlight with box and cover fitted in Robust designed assembly plates smug fit on the wall, Dust Free Glossy Finish, Pure White Color, Reputed make
Supply of 18W warm white LED square surface mounted LED flat panel 1”x 1”, Reputed make
Supply of 18W warm white LED square recessed flat panel 1”x 1”, Reputed make
Supply of 15W warm white LED round downlighter, Reputed make
Supply of 150mm sweep wall mounting with back shutter exhaust fan, Reputed make
Supply and fixing of 4” dia round PVC sheet, Reputed make
Supply and fixing of 1-module Neon Red Indicator on the existing modular plate including connection etc. as required, Reputed make
Supplying and fixing of 6-way(F1 + 18) surface/recess mounting, vertical type, 415V, TPN MCCB double door distribution board of sheet steel, dust protected, duly powder painted, inclusive of isolated neutral busbar, insulated busbar assembly, door earthing, suitable for MCCB’s upto 125A as incomer and IP 43 and above protection.
Supplying and fixing of 4-way(F1 + 12) surface/recess mounting, vertical type, 415V, TPN MCCB double door distribution board of sheet steel, dust protected, duly powder painted, inclusive of isolated neutral busbar, insulated busbar assembly, door earthing, suitable for MCCB’s upto 125A as incomer and IP 43 and above protection.
25W LED street light luminaries with sleek aesthetically designed pressure die cast aluminium housing, heat resistant toughened glass and IP 66 protection, Reputed make
Supply of 230V/16A, 24 Hrs timer Analog type with battery backup of 72 hrs or more, Reputed Make
Supply of 3P 1NO, 12A power contactors with coil voltage 230V AC, Reputed make
Supply of online water heater 3Ltr capacity, 230V, reputed make
Labour charges for fixing of water heater(Geyser) on the surface including cost of grip, screw, connection etc. as required
Labour charges for fixing of analog timer in the existing DB including connection etc. as required
Labour charges for fixing of 3P contactors in the existing DB including conections etc. as required
Labour charges for fixing of 25 W street light luminaries fixing in suitable size of GI pipe bending in ‘L’ shape on the wall/roof of the building including cost of clamp, grip, screw and painting 02 coats of enamel paint and connection etc. as required.
Transportation of electrical items mentioned in S.No. 26 to 41 from Port Blair to Little Andaman work site.
c.kumar
K C ELECTRICAL AND TRADING
M/s. D ARJUNA RAO Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .