Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-Finance BENARAS ROAD CHOWDHURY PARA KONA HOWRAH 711114 | HOWRAH | HOWRAH | WEST BENGAL | 711114 | L1 | Accepted-Finance Lowest Rate | |
| 2 | L2₹8.4 L+₹13,853.48 (1.68%)Rejected-Finance 7G CORNFIELD ROAD KOLKATA 700019 | KOLKATA | KOLKATA | WEST BENGAL | 700019 | L2 | Rejected-Finance THE BID IS NOT L1 | |
| 3 | L3₹8.4 L+₹15,165.65 (1.84%)Rejected-Finance MAITANA BATTALA PURBA MEDINIPUR | MEDINIPUR EAST | WEST BENGAL | 721130 | L3 | Rejected-Finance THE BID IS NOT L1 |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
25 Sept 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, EMD, PHE Dte
P-16, INDIA EXCH. PL. EXTN. CIT ANNEX BLDG.2F KOL 73
Rejuvenation of clarifoculator along with electromechanical and installation renovation work at treatment plant under N.S. Sanatorium, Kalyani, under EMD, PHE Dte. in the Dist. Of Nadia.
2024_PHED_744321_5
WBPHED/EE/EMD/NIET/05/2024-25
Open Tender
Miscellaneous Works
Item Rate
30 days
P-16, INDIA EXCH. PL. EXTN. CIT ANNEX BLDG.2F KOL
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,000
28 Oct 2024
5 Sept 2024
27 Sept 2024
5 Sept 2024
25 Sept 2024
5 Sept 2024
Amount
Repairing of motor mounting frame by gas cutting the worn out portion then welding with the help of 50mm X 50mm angle.
Supply & delivery at site induction motor with pully of below specification. A) Make-Kirloskar b) speed-1400RPM c) Supply voltage-415+ 5% d) Current-4.7Amp e) Rating-2.2KW
Making a electrical wiring from induction motor to panel board then from panel board to centre pivot with 4core cable conduit, clamp, double earthing wire terminal etc.. The conduit shoud be routed in such a system that it should not abstract the rotation of a bridge.
Fabrication of power transfer mechanism from static pole to dynamic bridge with the help of 4nos static coupler ring seperated each other with class-B insulator fixed on a static pole of height 12' & nominal dia-75mm. The dybamic portion will be fixed on a base plate & the power should be collected 4sets of carbon brass housed in electrical brass holder. The total mechanism must be enclosed in a metal cage that should be covered by aluminium sheet.
Surface dressing(610X610X1000)cum then reinforced cement concrete covering height 100mm then brick work with the help of 1st class brick & cement morter upto G.L. keeping a cell 400mm X 400mm further insertion of pipe 150mm nominal bore upto bottom & filling the gap with the help of stonechip cement, sand, motor futher a piller surrounding a post upto a height of 0.5m with plastering and neat cement finish.
Renovation of old worn out stair by cutting out old stair and making a new stair with MS angle and support and railing of a height of approx 23ft.as per requirement
Supply & delivery at site including design and manufacturing of aluminium Composite panel (ACP 3 MM ALUDECORE Exterior AL-33) LED Board with 12 mm imported acrylic pasted vinyl letter with following specification:- a) one side glassing alluminium tube of size 2.5" X 1.5" X1.5" mm dept with different colour LED as per direction of EIC. The board should have in built power circuit board connected with LED lamp suitable for operation in 230 volt 50HZ AC supply. b) The LED lighting should be of 1.5 watt. original LED modules connected for 12V, 400 watt power (2 years gurantee). c) The board back side should have exterior ACP cover and outside blue acrylic connection complete (Size-6'X4') As per follwing subject mention bellow.
Cost of making structural room for installation of 250Amps main switch with currugated glvanised sheet with the help of 50X50mm MS angle with making brick foundation as per direction of EIC.(Size-1.5mtrX 0.7mtrs)
Supply delivery and storage at site of following items :-
415Volt 250Amp 4pole SFU type main switch with three nos din type HRC fuse in SS enclosure of model KOMPACT ZERO/Equivalent.(Make-Havells/Siemens/ABB/L&T)
3.5core 50sqmm lugs
50sqmm 3.5 core XLPE insulated Al. Ar. Cable(Make-Polycab/Finolex/ Gloster)
16sqmm 4 core XLPE insulated Al. Ar. Cable(Make-Polycab/Finolex/ Gloster)
6sqmm 4 core XLPE insulated Al. Ar. Cable(Make-Polycab/Finolex/ Gloster)
Wooden sleeper of size (33"X6") of 30mm thickness
19mm dia 80mm long H.T. nut bolt and double washer
Laying of two cable in a under ground trench in a single tier formation (Horizontal) the trench size 680mm x 760mm average depth with brick protection on the top of each cable 8 (eight) nos. brick per mtr. and 4 (four) nos brick per mtr as seperator including filling the space between the brick and cable and also the trench with shifted soil, leveling up and restoring surface duty rammed as per direction of EIC. a. 3.5core 50sqmm
b. 4core 16sqmm
c. 4core 6sqmm
Installation of above supplied SFU and making connection with 50sqmm cable and lugs in above structural room as per direction of EIC.
Making internal electrification with 4nos tube light, 02nos fan, 01no bulk head ligh 02nos 6Amp plug point etc for pump house and guard room as per requirement.
Removing sludge & other materials of the clarifier collecting well by introducing pump and rope bucket arrangement by engagging sweeper, labour, damping the sludge in excavated pit at a minimum distance of 15m away from the clarifier followed by disinfecting by bleaching powder as per direction.(10m dia X 3m depth approx)
Desludging & through washing cleaning of the followed items after dewatering the same with necessary scalfolding arrangement wherever necessary including removing the disposal in the excavated pit & dusinfecting the same by bleaching powder as directed. a) Secondary clarifier(2nos)(4.3m dia X 2.15m depth approx)
b) Venus(01no) (5.5m dia X 1.5m depth approx)
c) Sump tank(1no) (4m dia X 2.15m depth)
Stripping off worn out plaster and raking out joints of walls, ceeling etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed(Different valve chember, venus, parapet, roof etc)
Construction of peet valve chember made with 250mm thick brick work in cement morter(1:4) complete with plastering along with a slab of suitable dimension for covering the same including supplying all necessary materials as peedirection. This includes cost of making an additional slab(1.85mX1.82mX0.05m) for 250mm dia sluice valve chember.(size of chember=1.85mX1.82mX1.25mX2nos)
Sand rubbing including preparing and smoothening surface with admixture of pigment if necessary as directed
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface (i) 1:4 cement morter (Different valve chember, venus, parapet, roof etc) 15mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. Cement 0.152 cu.m per100 sq.m.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary a. on timber or plastered surface:(primary clarifier, bio filter,, pump house, security room, toilet, etc.) with super gloss(hi-gloss) (iv) Two coats(with any shade except white) b) On steel or other metal surface With super gloss (hi-gloss) - (ii) Two coats (with any shade except white)
b) On steel or other metal surface With super gloss (hi-gloss) (main gate, pump house gate etc.) (ii) Two coats (with any shade except white)
Decoupling and dismantling of 15HP(01no), 12.5HP(02nos), 2HP(04nos) centrifugal pump motor set from the base frame after disconnection all the line i.e. electric lines, pipe lines, valves etc part by part carefully including necessary labour charge hiring charges for lifting arrangement as per direction of EIC.
Rewinding the above 15 H.P. Motor set by supplying required size enamelled copper wire (Modified polyster-155C) as per IS:13730-3, IEC 6017-3 and through out servicing, rectification by supplying new base plate, clip necessary emery paper, vernish, after taking out old burn burned copper wire as per direction of EIC. (At workshop)
Improvement of poor insulation of the stator by heat treatment then vernising dip to the stator coil and inpregnation of the stator winding for 48hours further check for insulation in respect to the body for required level.(12.5HP-02nos & 2HP-04nos)
Supply delivery of following items for above different motor:
Bearing 6309-2Z/C3GJN(SKF)
Bearing 6205-2Z/C3WT(SKF)
Oil seal
steal key
Nut bolt & washer
Terminal box
Cooling fan
Fan cover
Assemble of the above motor with the help of supplied items of sl no(25) along with old serviceble parts as per direction of EIC.
Supply delivery of following items for above different pump set:
Stuffing box(carbon steel) suitable for gland housing
Bearing 3311 A/C3(SKF)
Bearing NU 311 ECP(SKF)
Bearing 6306-2Z/C3GJN(SKF)
Oil seal
steal key
Metalic graphite packing
SS nut, bolt, washer
Spider bush
Rubber packing
Gear oil(Servo)
Casting of SS-316 shaft sleeve with the help of wooden pattern then shapping, turning & polishing
Assembling of the above pump with above supplied items(sl no 27&28) along with old serviceable spares.
Cost of painting of above pump motor set with anticorrosive materials
Transportation charge for carrying of above pump motor set(07nos) from worksite to workshop for above repairing works by loanding and unloading with sufficient labours and back to site worksite after repairing of above pump motor set.(2times i.e. before and after of repairing)
Re-assembling and recouping of above pump motor set and installation in existing base frame by greasing of all jointing parts and making all electrical & pipe line connection checking & testing all complete as per direction of EIC.
Add: GST @ 18%
Add: LW Cess @ 1%
CONCORD ENGINEERING (BID ID -5541347)
MENAKA ENTERPRISE (BID ID -5541310)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .