Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹67.9 L+₹7.9 L (13.1%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹69.5 L+₹9.5 L (15.8%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹69.6 L+₹9.6 L (16.0%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹70.9 L+₹10.9 L (18.2%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | M/s Shri Inder Construction Company L4 | M/s Rashid Mohammed L2 | M/S R.K. Builders & Developer L5 | SHRI K P ENTERPRISES L3 | Rakesh Choudhary Contractor L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | B&R WORK Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 470 | SQM | 50 ₹23,500 | 20 ₹9,400 Lowest | 50 ₹23,500 | 20 ₹9,400 Lowest | 35 ₹16,450 |
| 2.00 | M&L for non skid ceramic tiles colour tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge. | 40 | SQM | 950 ₹38,000 | 1,100 ₹44,000 | 850 ₹34,000 Lowest | 1,150 ₹46,000 | 1,000 ₹40,000 |
| 3.00 | M&L for non skid ceramic colour tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.18 but n exc 0.38 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:4) complete all as specified and directed by Engineer-in-Charge. | 300 | SQM | 950 ₹2,85,000 Lowest | 1,030 ₹3,09,000 | 1,050 ₹3,15,000 | 1,200 ₹3,60,000 | 1,100 ₹3,30,000 |
| 4.00 | M&L for Glazed ceramic glossy finish tiles coloured in vertical surface 450X300X7mm in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge. | 100 | SQM | 1,100 ₹1,10,000 | 1,000 ₹1,00,000 | 900 ₹90,000 Lowest | 1,200 ₹1,20,000 | 1,150 ₹1,15,000 |
| 5.00 | All as per item No. 3.00 here-in-before above but as in skirting over & including 10mm thick backing coat of CM 1:4 complete all as specified and directed by Engineer-in-Charge. | 30 | SQM | 1,350 ₹40,500 | 1,100 ₹33,000 | 1,050 ₹31,500 Lowest | 1,250 ₹37,500 | 1,100 ₹33,000 |
| 6.00 | Dismantling of Stone slabs and tiles of any description or thickness in floors, walss, aprons etc laid bedded and pointed in any mortar removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 41.5 | X SQM | 900 ₹37,350 | 500 ₹20,750 | 500 ₹20,750 | 150 ₹6,225 Lowest | 300 ₹12,450 |
| 7.00 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed by Engineer-in-Charge. | 300 | SQM | 950 ₹2,85,000 | 1,300 ₹3,90,000 | 900 ₹2,70,000 Lowest | 1,140 ₹3,42,000 | 1,200 ₹3,60,000 |
| 8.00 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar and laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-Charge. | 60 | SQM | 1,350 ₹81,000 | 1,350 ₹81,000 | 950 ₹57,000 Lowest | 1,240 ₹74,400 | 1,250 ₹75,000 |
| 9.00 | M&L for Granite of black / green / imperial red (colour as approved by AGE) of any type machine cut as in shelves/steps/counter tops, 20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick/ endering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive for fixing on unpolished kota stone slabs and including rubbing, cutting and mirror type polishing and bull nose on exposed sides complete all as specified and directed by Engineer-in-Charge.
Note : Single piece should be used in steps/cills/jambs/shelves or equivalent as approved by AGE . | 30 | SQM | 2,350 ₹70,500 Lowest | 3,000 ₹90,000 | 3,000 ₹90,000 | 5,420 ₹1,62,600 | 3,000 ₹90,000 |
| 10.00 | M&L for Jaisalmer stone for wall cladding (of any type) 35-55 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of stone, exc .0.06 sqm but not exc 0.11 sqm including cutting and polishing types in wall including 20mm thick CM 1:4 for laying Jaisalmer stone complete all as specified and directed by Engineer-in-Charge. | 25 | SQM | 1,450 ₹36,250 | 2,200 ₹55,000 | 1,200 ₹30,000 | 2,450 ₹61,250 | 1,000 ₹25,000 Lowest |
Tender Value
₹75.1 L
EMD Value
₹1.4 L
Closing Date
30 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
BILL OF QUANTITIES(BOQ)
SPL REPAIR TO BLDG No. P-10 (ADM BLOCK) AT POKARAN MIL STN UNDER AGE(I) POKARAN
2025_MES_710829_1
84316/C/E8
Open Tender
Civil Works
Item Rate
180 days
POKARAN
AS PER NIT
8 documents required · 8 mandatory
₹1,000
AGE(I) POKARAN
₹1.4 L
Yes
14 Aug 2025
28 May 2025
2 Jul 2025
28 May 2025
30 Jun 2025
18 Jun 2025
28 May 2025 - 4 Jun 2025
Amount
B&R WORK Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic tiles colour tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic colour tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.18 but n exc 0.38 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic glossy finish tiles coloured in vertical surface 450X300X7mm in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
All as per item No. 3.00 here-in-before above but as in skirting over & including 10mm thick backing coat of CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Dismantling of Stone slabs and tiles of any description or thickness in floors, walss, aprons etc laid bedded and pointed in any mortar removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar and laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for Granite of black / green / imperial red (colour as approved by AGE) of any type machine cut as in shelves/steps/counter tops, 20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick/ endering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive for fixing on unpolished kota stone slabs and including rubbing, cutting and mirror type polishing and bull nose on exposed sides complete all as specified and directed by Engineer-in-Charge. Note : Single piece should be used in steps/cills/jambs/shelves or equivalent as approved by AGE .
M&L for Jaisalmer stone for wall cladding (of any type) 35-55 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of stone, exc .0.06 sqm but not exc 0.11 sqm including cutting and polishing types in wall including 20mm thick CM 1:4 for laying Jaisalmer stone complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing water proofing treatment including bedding if any n. exc. 50mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed by Engineer-in-Charge.
Dismantling Stone slabs in roofs, suspended floors , chajjas, landings, etc., any thickness, jointed in any mortar complete all as specified and directed by Engineer-in-Charge.
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set, jointed and grouted in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 13.00 here-in-before above but except stone slab complete all as specified and directed by Engineer-in-Charge. NOTE : Old serviceable stone slab retrieved vide Sl Item No. 12.00 shall be reused.
M&L for 40mm consolidated thickness PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course all as per the requirements complete all as specified and directed by Engineer-in-Charge.
M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment, with using WPC complete all as specified and directed by Engineer-in-Charge. Note :- WPC will be measured and paid separately under relevant item
Supply only integral Waterproofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt not less than 150 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltr/Sqm by forced complete all as specified and directed by Engineer-in-Charge Four course roof treatment consist of as under:- (i) Applying one coat of bituminous primer conforming to IS-3384 @0.3 Ltr per sqm, (ii) Laying of APP based membrane as specified thickness and weight, (iii) Applying one coat of aluminium paint @ 100 ml/sqm
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished fair & even without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separately under relevant item
M&L for 5mm thick plaster in cement mortar (1:3) on ceiling surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bond distemper over a coat of 3mm thick putty including one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistance primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old plastered or unplastered distempered surfaces of wall and applying one coat of distemper oil emulsion complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC door frames of size 50x47mm made out of 5mm plain colour PVC sheet supplying and fixing in opening as per specification and drawing shown in SSR complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification incl the fwg S & F As approved by AGE (a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm - 3 Nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf
Taking down door/windows/ventilators chowket or frame incl shutter area n exc 1.50 sqm Each and removing to store complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames door/windows/ventilators (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed by Engineer-in-Charge.
S&F Factory made ISI marked flush door shutters 35mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and including supply and fixing following items As approved by AGE : (a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm - 4 Nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf (d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf (e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-foRming to Fe 290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
S&F in repair Double action floor spring ISI marked hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer-in-Charge.
S&F toughned glass 12 mm thick as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes with all accessories like handle, stopper with glazing with beads fixed with metal panel pins complete all as specified and directed by Engineer-in-Charge.
S&F floor door stopper of aluminium 150mm size complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire 0.36mm nominal dia of wire and average width of aparture 1.40mm complete all as specified and directed by Engineer-in-Charge.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqn in Each pane complete all as specified and directed by Engineer-in-Charge.
S&F 4 mm thick figured glass, pin headed type and glazing with oil putty in square n exc 0.50 sqn in Each pane complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new untreated steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed by Engineer-in-Charge.
S&F in repair aluminium anodised, (fancy type) curtain rod, 20mm dia, complete all as specified and directed by Engineer-in-Charge.
S&F in repair bracket aluminium anodised, (fancy type) for 20 mm dia tubular curtain rod(for item above) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in ground floors and pavings not exc 15cm thickness below or above ground level etc complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
Dismantling of water tanks and removing to store capacity of tank exc 250 and n exc 500 ltr complete all as specified and directed by Engineer-in-Charge.
S&F for Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to dia of pipe 20mm complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store 15 mm bore to walls, ceiling etc. complete all as specified and as directed by the Engineer-in-Charge.
All as per item No. 50.00 here in before above but 20mm dia pipe complete all as specified and as directed by the Engineer-in-Charge.
Re-fixing old steel tubing 15 mm tubes medium grade galvanized with all fittings such as Tee, elbows, sockets, unions, plugs, short lenghts etc. and fixed complete to walls and ceilings or laid in floors concealed or open of any length complete all as specified and as directed by the Engineer-in-Charge. NOTE : Old serviceable steel tubing 15 mm tubes retrieved vide Sl Item No. 50.00 shall be reused.
S&F 15mm bore tubes medium grade galvanized with all fittings such as Tee, elbows, sockets, unions, plugs, short lenghts etc. and fixed complete to walls and ceilings or laid in floors concealed or open of any length complete all as specified and as directed by the Engineer-in-Charge.
All as per item No. 53.00 here in before above but 20mm dia pipe complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 15 mm bore pipe complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs gun metal globe or gate valves with iron wheel head screwed both end for iron pipe and fixed in repairs to 20 mm bore pipe complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs for stop cock copper alloy but fancy type and chrominum plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron/pipe or for union and fixed 15 mm borecomplete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 15mm dia bib taps cast cipper alloy chromoum plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs fancy type pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank supply and fixing ly nuts for iron pipe of 15mm bore complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Vitreous china premium/1st quality urinal bowl type of white colour, of size 330x300x450mm incl providing and fixing plugs/brackets, bedding urinal against wall in CM 1:2, securing urinals to plugs with and incl S&F of all accessories for fixing as recommended by manufacturer like 60mm long brass secrews/fasteners/rag bolts etc, pointing urinal back in white cement; connecting for discharge pipe including necessary packing, union complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Urinal spreader of PTMT any colour for fixing with 15mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs Viterious china White Wash Hand Basin of size 580mm x 450mm including 15 mm pillar cock cast copper alloy CP, 15mm cast copper stop valve, 32 mm brase CP waste fitting, PVC waste pipe 32 mm dia & 15 mm PTMT connection pipe 450 mm long complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs towel rail 600 mm long of Brass C.P 'D' type fixed with and including chromium plated brass screws and wooden /plastic cheats complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs stainless steel sink with drainage board , made out of 1.00mm thick sheet for kitchen or laboratory with plug,washers, waste pipe, cast irn cantilever bracket of overall size 915x460mm bowl size 410x330x160mm complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair CP Shower rose 125mm size with swivel joint including fixing sted pipe for union complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Vitreous china premium/1st quality wash down water closet wall hung EWC (One piece) P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe PVC 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, incl 100mm dia cast iron sanitary connections-short connections pipe of length upto 600 mm and Cutting holes in or through walls, packing with PCC 1 : 2 :4 complete and taking down existing of any description/size complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs PVC connections 15 mm size with PTMT nuts to length 600 mm complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and as directed by the Engineer-in-Charge.
Cutting holes in to or through in brick or stone walls built in cement mortar and making good in CM 1:3 or cement concrete 1:2:4 type B1 as required, exc 150sqcm & n exc 400 sqcm complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of cast iron RCC, AC or PVC pipe jointed in CM any dia bore complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and directed by Engineer-in-Charge.
S&F 100 bore of pipe stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends with access door of 110 mm dia, any radius complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends with access door of 75 mm dia, any radius complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends of 75mm dia, any radius complete all as specified and directed by Engineer-in-Charge.
(PVC (SWR) vent cowl, 100 mm dia complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work, PCC block or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-Charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 83.00 here-in-before above but except stone complete all as specified and directed by Engineer-in-Charge. NOTE : Old serviceable stones retrieved vide Sl Item No. 82.00 shall be reused.
M&L for squared rubble walling, brought upto coursed Jodhpur type well bonded bedded laid dry complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 85.00 here-in-before above but except stone complete all as specified and directed by Engineer-in-Charge. NOTE : Old serviceable stones retrieved vide Sl Item No. 82.00 shall be reused.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified and directed by Engineer-in-Charge.
Providing and placing in position microconcrete which shall be cement based prepacked single component, chloride free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion obtained from approved manufacturer of thermoex chemical as per speciification and direcation of engineer-in-charge. Note :- payment under this item shall be made only after wet curing bas been done and surface has been satisfactory evaluated by sounding/tapping with blunt metal instrument
Dismantling wall and ceiling boarding of any description, thickness including cover fillets complete all as specified and directed by Engineer-in-Charge.
M&L for providing and fixing Gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium snap grid of size of grid 605 x 605mm frame work for false ceiling complete all as specified and directed by Engineer-in-Charge. Note :- (i) Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm. (ii) Rate quoted by the contractor shall deemed to inclusive of frame work complete.
S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all respect including supply and fixing of all accessories like fasteners/screws/solvent etc all as recommended by manufacturer all as specified (colour/pattern as approved by Accepting Officer).
Dismantling of Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed by Engineer-in-Charge.
M&L for 35mm thick precast cement concrete louvres and jallies type C-0 (1:3:6) using 12.5mm graded stone aggregate (measured solid), including all mouldings and frame set in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Demolition of plain cement concrete (Un-reinforced) in benching and surface channels,bedding etc. below or above ground level complete all as specified and as directed by the Engineer-in-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar as in concrete bed, haunching set in cement mortar of 150 mm dia complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n.exc 1.5m deep and n.exc 1.5m wide in manholes,etc. and getting out any type of soil complete all as specified and as directed by the Engineer-in-Charge.
M&L for plain cement concrete 1:4:8 Type D2 using 40mm graded aggregate as in foundation, filling in mass concrete for manholes & drains complete all as specified and as directed by the Engineer-in-Charge.
M&L for plain cement concrete 1:2:4 Type B1 using 20 mm graded aggregate as in benching and surface channel of manholes complete all as specified and as directed by the Engineer-in-Charge.
M&L for plain cement concrete 1:3:6 Type C1 using 20mm graded aggregate as in coping including necessary form work etc complete all as specified and as directed by the Engineer-in-Charge.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl, forms mould, mi-tred/stopped ends etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15mm thick in CM 1:4 on stone masonary sufaces on wall including finished even and smooth using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for reinforced concrete NP-3 drain pipes 150 mm Dia pipes confirming to IS laid in trenches and jointed in CM 1:2 complete all as specified and as directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes including packing under haunching against the sides of pipe after they are laid and tested; in cement concrete 1:4:8 type D-2 for 150mm dia pipe complete all as specified and as directed by the Engineer-in-Charge.
M&L for reinforced concrete NP-2 drain pipes 200 mm Dia pipes confirming to IS laid in trenches and jointed in CM 1:2 complete all as specified and as directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes including packing under haunching against the sides of pipe after they are laid and tested; in cement concrete 1:4:8 type D-2 for 200mm dia pipe complete all as specified and as directed by the Engineer-in-Charge.
M & L for cutting in to existing manhole for connectiing new drain 150 mm bore , making good to pipe & rendering cutting out existing benching for & forming branch channel in cement concrete (1:2:4) type B1 smooth finished & reforming benching as requierd complete all as specified and as directed by the Engineer-in-Charge.
Returning filling in soil including spreading, levelling and well ramming in layers n.exc 25cm thick in layer etc complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) complete all as specified and as directed by the Engineer-in-Charge.
M&L for providing cement concrete 1:2:4 type B-1 (20 mm graded aggregate) as in kerbs of mud stops, rounded or chamfered on edges complete all as specified and as directed by the Engineer-in-Charge.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub bases complete all as specified and as directed by the Engineer-in-Charge.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume sheet aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Excavation in post holes (or similar holes) each n exc 0.5cu .m,getting out in soft/loose soil, returning,filling in and ramming earth or broken rubble mixed with earth around,in layer not exceeding 25 cm,watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:3:6 Type C-2 (using 40 mm graded stone aggregate) in walls or retaining walls, any thickness size of shape including,pilasters, boundary pillars and posts (including post and bases) complete all as specified and as directed by the Engineer-in-Charge.
Dismantling structural steel works including steel work in doors, gates, framed truss etc complete all as specified and as directed by the Engineer-in-Charge.
S&F for MS work confirming to Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 etc complete all as specified and as directed by the Engineer-in-Charge.
S&F Roof trusses (framed), sunshade frames, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250) complete all as specified and as directed by the Engineer-in-Charge.
E&M WORK Taking down carefully existing point wiring of any description light, fan,sockets,bells etc) complete including fittings such as terminal boxes, switches, sockets, ceiling rose, lamp holders, brackets sketch fittings, pendants, fan regulartors and making good the disturbed surfaces, walls, floors etc. complete all as specified and directed by engineer-in-charge.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and directed by engineer-in-charge.
Taking down old unsv MCB DB / main switch incl MCBs / MCCBs complete all as specified and directed by engineer-in-charge.
Taking down existing sub main wiring /Service wire of any description and size including earth wire, quities and making good disturbed surfaces of walls, floors etc. Including one run of 2mm dia bare earth continuity wire complete all as specified and directed by engineer-in-charge. (Note : Two runs of aluminium / Copper conductor, and one run of GI earth wire will be measured and paid as one unit only)
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated cable 1100 Volts grade multistranded copper conductor drawn through in PVC Conduit concealed on underground stone / brick, masonry walls, roofs floors etc including MS terminal boxes fabricaterd out of 1.12mm thick MS sheet sunk type / surface type and laminated top sheet of 2mm thick for housing switches sockets, regulators etc including provn of 1.5 sqmm dia copper conductor for earth wire connected to common dolly for One light point / Fan point / Exhuast Fan / Bell point controlled by one 5 Amps One way switch and making good surfaces complete all as specified and directed by engineer-in-charge.
All as per Item No. 125.00 here-in-before but for one 3 pin 5/6 Amps switch socket outlet on same board
All as per Item No. 125.00 here-in-before but for one 3 pin 5/6 Amps switch socket outlet on independent board
All as per Item No. 125.00 here-in-before but for wiring with 4.0 Sq mm and 4.0 sqmm for earth continuity for 3 pin 15/16 Amps switch socket combination
S&F bell (buzzer / ding dong) working on 230 volts AC complete all as specified and directed by engineer-in-charge.
M&L for modular switch 1 way 6A, 1 module single pole complete all as specified and directed by engineer-in-charge.
M&L for modular switch 1 way 16A, 1 module single pole confirming to IS 3854 : 1997 complete all as specified and directed by engineer-in-charge.
S&F modular Bell Push 6A, 1 Module complete all as specified and directed by engineer-in-charge.
M&L for modular socket 6A 2/3 pin combined 2 module outlet, multipurpose complete all as specified and directed by engineer-in-charge.
M&L for modular socket 16/6A 3 pin combined 2 module outlet, multipurpose complete all as specified and directed by engineer-in-charge.
S&F electronic type modular fan step regulator 120W, 2 module AC 240 V complete all as specified and directed by engineer-in-charge.
M&L for modular white cover plate with frame ( both inner & outer plate cover) 1 module complete all as specified and directed by engineer-in-charge.
M&L modular white cover plate with frame ( both inner & outer plate cover) 2 module complete all as specified and directed by engineer-in-charge.
M&L modular white cover plate with frame ( both inner & outer plate cover) 3 module complete all as specified and directed by engineer-in-charge.
M&L Modular white cover plate with frame ( both inner & outer plate cover) 4 module complete all as specified and directed by engineer-in-charge.
M&L Modular white cover plate with frame ( both inner & outer plate cover) 6 module complete all as specified and directed by engineer-in-charge.
M&L Modular white cover plate with frame ( both inner & outer plate cover) 8 module complete all as specified and directed by engineer-in-charge.
M&L lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed by engineer-in-charge.
S&F LED Lamp Retro fit type 9 watts 230 V complete all as specified and directed by engineer-in-charge.
S&F ceiling rose surface bakelite 65 x 50 mm 2/3 terminais complete all as specified and directed by engineer-in-charge.
S&F VTPN DB 4 Way confirming to IEC 61439-3 suitable for flush mounting and furface mounting With 250 A Copper Busbar for each phase With 2 Neutral bar, 2 Earth bar and Cable ties for Cable management fully insulated busbar & shrouded neutral bars improved pan assembly for ease of installation prefitted masking sheet reversible door for confirming to IP 43 DB's with provision for DPX³ 160 MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed by engineer-in-charge. Make :- Cat Pat No. 5077 45 of Legrand or equivalent make and Cat part No. as approved by AGE (I)
S&F sheet modular metal enclosure DB TPN 415 Volts 4 Way double door type with 200 Amps busbar for fixing of MCBs complete all as specified and directed by engineer-in-charge.
S&F sheet modular metal enclosure DB SPN 240 Volts 8 Way single door type with 200 Amps busbar for fixing of MCBs complete all as specified and directed by engineer-in-charge.
S&F MCB Tripple pole and neutral, 63A, 415 Volts AC complete all as specified and directed by engineer-in-charge.
S&F MCB Single pole and neutral, 40A, 415 Volts AC complete all as specified and directed by engineer-in-charge.
S&F MCB Single pole, 5-32A, 415 Volts AC complete all as specified and directed by engineer-in-charge.
M&L for submain wiring with 4 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC concealed conduit underground stone / brick, masonry walls, roofs floors and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring including making good surfaces complete all as specified and directed by engineer-in-charge. Note : Four runs of copper conductor and one run of copper earth wire will be measured and paid as one unit only
All as per Item No. 151.00 here-in-before above but for sub main wiring with two runs of 4.0 Sq mm single core and one run of 4.0 Sqmm PVC insulated copper conductor for earth continuity wire complete all as specified and directed by engineer-in-charge. Note: Two runs of copper conductor and one run of copper earth wire will be measured and paid as one unit only
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed by engineer-in-charge.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by engineer-in-charge.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by engineer-in-charge.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by engineer-in-charge.
M/s Rashid Mohammed (BID ID -3340488)
SHRI K P ENTERPRISES (BID ID -3333380)
M/s Shri Inder Construction Company (BID ID -3331546)
M/S R.K. Builders & Developer (BID ID -3341819)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .