Supply, installation, testing and commissioning of Telecom material in connection with Provision of CCTV System at Station yard area to monitor main line points and crossings, especially in Ratlam Division.(Phase-I 38 Stns)
SnT-RTM-26-TELE-12
SnT-RTM-26-TELE-12
Open
12 Months
Ratlam, Madhya Pradesh
₹0
₹6.6 L
12 Jun 2026
12 Jun 2026
30 Jun 2026
B1-SOR execution
B2-NS execution
Item Breakup - A1-SOR supply
76.00 length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.
0.75 136063.55 copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. Total 892681.74
Item Breakup - A2-NS supply
Supply of VMS VSS server Hardware for Numbers video management & video recording as per RDSO spec. No: RDSO/SPN/TC/65/2021 Ver. 6 Amdt. 1, 2 & 3 or latest.{Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}
Supply of 6 core armoured Mono mode Metre OFC cable as per specification
Supply of 6 core fiber termination box Numbers with Capacity of Ports: 6 ports, Suitable Adapter: SC/LC
Supply of STP CAT-6 Cable (Shielded Metre Twisted Pair) STP compliant with latest EIA/TIA-568-B2-1 or latest
Supply of Fibre Distribution Management Numbers system (FDMS)/LIU for 12 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec.GR/FDM/01/02April' 2007 or latest. This include supply of installation accessoriesas per technical specification
Supply of Permanently Lubricated (PLB) Metre High- density polyethylene (HDPE) Telecom duct for use as underground cable conduits -40/33 mm as per RDSO specification No.RDSO/SPN/TC/45/2013 Rev.2.0 with Amdt. 3 or latest (Necessary coupler and bend included in above)
Supply of RJ 45 Connector DAX, D-link, Numbers Digisol, AE, Molex,Amphenol make as approved by Engineer in charge
Supply of White PVC Pipe of dia 1 Inch of Metre as per Standard IS:9537 (Part 3) with Pipe length of 3 mtrs each (Bend and Eblow as per site requirement will be supplied along with pipe)
Supply of Galvanized Iron Hot dipped Metre Power Coated Perforated Type Cable TRAY, Size W-100 mm, H- 50 mm, 1.5 mm thick. Tray Material Specification should be as per EN ISO 1461 RATLAM DIVISION-S AND T/WESTERN RLY
Supply of 6-metre pole (with tripod/guy Numbers support at Station/OFC Hut/Yard) complete with enclosure box for Data Communication equipment. Detailed specifications are attached. The final Location, specification and mounting arrangement shall be decided by the Site Engineer-in-Charge as per site requirements.
Supply of 19" covered racks, valrack/vero Numbers president /rittel / APC /D link make or similar having a size of approximately 2.2 meters.(42U) height X 800mm width X800 mm depth as per specification and duly approved by the engineer in charge
Supply of 6A, Double Pole with 2PP 240V Numbers MCB as per specification
Supply of OFC Modern Tool Kit as per Numbers specification attached
Supply of Iron cage for protection of Numbers Cameras
Supply of power line protection device Numbers class D as per technical specification Total 7474888.82
Item Breakup - B1-SOR execution
76.00 Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008.
9900.00 route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in- charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
direction without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring). RATLAM DIVISION-S AND T/WESTERN RLY
33000.00 pairs/ quads in trenches/ GI pipes/ RCC Metre pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Total 11018576.54
Item Breakup - B2-NS execution
Supply, Commissioning of FullHD PTZ type IP ColourCamera along with 128 GB orHigher SD Card, housing andmount and all accessoriesrequired for installationpurposes as per RDSO SpecNo RDSO/SPN/TC/65/2021 Ver. 6 Amdt. 1, 2 & 3 or latest. Material should be compatible to existing system.{Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}
Supply, Commissioning of Digital key board (joystick) compatible with PTZ cameras as per RDSO spec. No: RDSO/SPN/TC/65/2021 Ver. 6 Amdt. 1, 2 & 3 or latest. Material should be compatible to existing system
Installation, testing & Commissioning of Numbers VMS Server as per latest Railway guidelines.
Supply and installation of Storage Numbers System at RPF Thana/Post sites for recording of cameras from cluster of stations. Storage per TB (Including Card & All accessories). Material should be compatible to existing system
Supply, commissioning of PC Workstation for Viewing cameras in multi screen mode, Monitoring and System management and 4K UHD LED Monitor of 24 inch size along with 2 HDMI PORT in graphic card including all required licensed software's for VSS(like OS, MS Office, Anti-virus with 03 years subscription), multifunction device for documentation, accommodate PC workstation & monitor with all accessories, spike buster (minimum 5 nos. 6A points with fuse), SOOVA UPS, Mounting Rack and other required materials as per RDSO spec. No: RDSO/SPN/TC/65/2021 Ver. 6 Amdt. 1, 2 & 3 or latest Clause No. 11.0. Material should be compatible to existing system. RATLAM DIVISION-S AND T/WESTERN RLY
Supply and installation of switches 8 port Numbers manageable POE with Installation as per specification attached. Material should be compatible to existing system {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}
Supply and installation of 24 port Numbers manageable Layer -2 aggregate switch with 24 x GE SFP port and 4x 10GE SFP+ ports as per RDSO spec. No: RDSO/SPN/TC/65/2021 Ver. 6 Amdt. 1, 2 & 3 or latest Clause 14.0(i). All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. Material should be compatible to existing system. Type-III switches as Top of the rack Switch in (1+1) with Optics and all accessories {Trusted Telecom Portal (TTP) approval and compliance with other applicable regulatory guidelines, if any, are mandatory}
Splicing of fibres of OFC Cable and Numbers making Splice joint with contractor's own splicing machine and tools, and consumables. Testing should be done by contractor's engineer with his own OTDR and optic loss test set with railway engineer trace for the fibers shall be taken and signed jointly. If any fiber splice shows high loss/lossy event, the same shall be redone before completion of the splicing work. (Rates are for a single fiber splice)
Installation, Testing & Comissioning of 12 Numbers port loaded LIU rack mountable. All the accessories and fixing materials required for this installation are to be supplied by the contractor within the same cost .
Blowing of OFC through HDPE duct & Metre protective work (elicited in above item) already provided.Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for anyother reason, OFC shall be drawn or laid manually as per standard procedure.All the equipments and machinery required shall be arranged by thecontractor at his own cost.In case OFC is to be laid adopting 'Direct in trench' method then this item shall be paid as peraccepted rate of thisschedule.OFC and HDPE pipe shall be supplied by the Railway.Blowing/Laying shall bestarted from one end and each drum laying shall be monitored afterblowing/laying and before leaving the site,trace/cable parameters for all the fiber/ conductors shall be taken from one central location by contractor's engineer with his own OTDR , optic talk set/ measuring equipments with railway engineer RATLAM DIVISION-S AND T/WESTERN RLY
Laying of HDPE pipe as per approved Metre cable route plan in the excavated trench, taking due care while transporting andlaying the same in the trenches or otherprotective works. Both the end of duct should besealed with end plugsbefore laying and should remain sealed till blowing is done
Wiring, drawing, fixing, laying and Metre clipping of all telecom cable/PVC Power cable in PVC pipe/duct/Casing caping with complete fitting as per the instruction of site Engineer
Fixing of tray for housing all type of Metre telecom cable. (All accessories required for fixing of tray is provided by the contractor)
Cutting of the platform surface (Tile/Slab) Metre for a depth of 25cm and a width of 10cms and refilling/ Reconditioning/ Concerting/ Repairing the platform after laying HDPE/racewayas/pipe and cable. Cutting should be done with marble cutting machine in proper manner and restore the same as before in such a manner that aesthetic of the platform is not disturbed.
Supply, Commissioning of software (per camera basis) for video management and video recording with license as per RDSO spec. No: RDSO/SPN/TC/65/2021 Ver. 6 Amdt. 1, 2 & 3 or latest. Material should be compatible to existing system
Supply, Commissioning of Graphical User Interface based Client software (per workstation basis) for work station as per RDSO spec. No: RDSO/SPN/TC/65/2021 Ver. 6 Amdt. 1, 2 & 3 or latest. Material should be compatible to existing system
Erection/Fixing and Installation of Poles Numbers including RCC work, depth as per site requirement
Supply & Installation of Weatherproof Numbers IP65 rated Location Box with all accessories as per technical specification Total 15080449.91
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022.pdf
ATTACHMENT
FinalUploadSpecialConditionofContractforApprovalDt040626.pdf
ATTACHMENT
FirstSecondsheetforapprovalDt020626.pdf
ATTACHMENT
VariousformatUploadlDt020626.pdf
ATTACHMENT
TechSpecsApprovedDt120626.pdf
ATTACHMENT
20260326_CCE_SimilarnatureofworkforvariousTelecomworksTendersMar26.pdf
ATTACHMENT
RailwayBoardPolicyLetterDt020120262MtrDepth.pdf
ATTACHMENT
GCCAmdandcorrectionslips.pdf
ATTACHMENT
TANMPLS.pdf
ATTACHMENT
TANEarthDt040725.pdf
ATTACHMENT
CCESirLetterdt101023for4x48OFC.pdf
ATTACHMENT
Download all tender documents and submit your bid