Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | ₹39.8 L Quoted ₹40.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹43.4 LRejected-Finance | ₹43.4 L | L2 | Rejected-Finance other than L1 |
| Sl No | Description | Qty | Unit | deepankar trading co. L2 | J S CONSTRUCTION CO L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water and removing the debries outside the MOD land etc complete all as specified and directed by Engineer-in-Charge. | 620 | Sqm | 10 ₹6,200 | 7 ₹4,340 |
| 2.00 | M&L for rendering CM (1:6) 10 mm thick on fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge. | 260 | Sqm | 100 ₹26,000 | 145 ₹37,700 |
| 3.00 | M&L rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement with water proofing compound complete all as specified and directed | 190 | Sqm | 110 ₹20,900 | 165 ₹31,350 |
| 4.00 | M & L rendering 5mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement etc built in cement mortar etc complete all as specified and directed by Engr In Charge. | 150 | Sqm | 100 ₹15,000 | 110 ₹16,500 |
| 5.00 | M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls up to four storey height building complete and specified and as directed | 260 | Sqm | 30 ₹7,800 | 50 ₹13,000 |
| 6.00 | M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty, up to four storey height building complete all as specified and directed | 1,600 | Sqm | 20 ₹32,000 | 50 ₹80,000 |
| 7.00 | M&L for preparation on new or previously untreated wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over putty up to four storey height building complete all as specified and directed by Engineer-in-Charge. | 190 | Sqm | 65 ₹12,350 | 50 ₹9,500 |
| 8.00 | M&L for preparation of old plastered or unplastered surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surface over putty up to four storey height building complete all as specified and directed by Engineer-in-Charge. | 515 | Sqm | 65 ₹33,475 | 50 ₹25,750 |
| 9.00 | M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling up to four storey height building complete and all as specified and directed. | 140 | Sqm | 10 ₹1,400 | 15 ₹2,100 |
| 10.00 | M & L preparation of old plastered surface and applying two coats of white wash on ceiling up to four storey height building complete and all as specified and directed by Engr-in -Charge. | 180 | Sqm | 8 ₹1,440 | 15 ₹2,700 |
Updated dates
Tender Value
₹48.5 L
EMD Value
₹96,940
Closing Date
23 Dec 2025, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2025_MES_741606_1
GE/SP/TOKEN-55/2025-26
Open Tender
Miscellaneous Works
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹96,940
Yes
1 Apr 2026
26 Nov 2025
26 Dec 2025
26 Nov 2025
23 Dec 2025
11 Dec 2025
Amount
Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water and removing the debries outside the MOD land etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering CM (1:6) 10 mm thick on fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M&L rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement with water proofing compound complete all as specified and directed
M & L rendering 5mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement etc built in cement mortar etc complete all as specified and directed by Engr In Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls up to four storey height building complete and specified and as directed
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty, up to four storey height building complete all as specified and directed
M&L for preparation on new or previously untreated wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over putty up to four storey height building complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered or unplastered surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surface over putty up to four storey height building complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling up to four storey height building complete and all as specified and directed.
M & L preparation of old plastered surface and applying two coats of white wash on ceiling up to four storey height building complete and all as specified and directed by Engr-in -Charge.
M&L for two coats of synthetic enamel paint incl preparation of new /old painted steel surface exc 10 cm width or girth complete all as specified and as directed
Demolition of reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jali,slab, Parapit wall and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed
All as per item No 13 here in before But not exc 1.5 Sqm .
S&F aluminium frame powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified.
S&F 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc.omplete all as specified and directed
S&F for powder coated aluminium doors shutters,( thickness of powder coating not less than 50 micron) alumonium section weighing 0.55 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing , handels 2 Nos in each door , hinges, anodised aluminium snap beading screws etc. complete all aspecified and directed.
S&F aluminium powder coated an (minimum thickness of powder coating 50 micron) as in window and ventilator shutters, sliding type three track, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber packing, anodised aluminum snap beading screws etc complete all as specified and as directed.
S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete and specified and as directed.
S&F in repair aluminium deco grills confirming to DG-104 grade all as specified and directed.
S&F 150 mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete and specified and directed.
S&F brass body mortice lock vertical type size 100mm 4 lever, including escutcheon plate and two No keys fixed complete all as specified and directed.
S & F in repair aluminium(Die cost ) body door closer hydraulically operated designation No-03, universal type, suitable for door shutters of 851 to 1000mm width and of weight of 61 to 80 Kg complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish out side MOD land complete all as specified and directed.complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surface 300mmX 450mmX 7/300mmx600mmx9mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 complete all as specified and directed.
M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
All as per item No 28 here in before but as on vertical surface of wall such as skirting/dado incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and directed
M&L Granite 18-20 mm thick(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite( including moulding etc) complete all as specified and directed.
S&F in repairs for double action floor spring hydraulically regulated mode lap of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to shutter complete all as specified and directed
S & F 25 mm dia Stainless steel coated curtain rod including all necessary fixing arrangement like clamps, end to end bracket per meter complete all as specified and directed .
S&F in repair for false ceilings using GI sanp grid system with rool-formed out of hot drip galvanised steel capings (Powder coated) main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceilimg board, prepainted cement fibre board size 595x595x4mm thick any texture (Lake, Hill, ocean cascade or Electra ) suspended from from RCC roof/ structural members of soofits angle cleat cut out etc to ther equired line and shape as per manufactureres recommndations at any height complete all as specified and as directed
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed.
M&L for Brick work with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Dismantling loose concrete cover of RCC columns, beams, slabs chajjas and the like as directed, roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry, incl derusting of steel reinforcement, providing fabric mild steel wire mesh 75 mm x 75 mm x 2 mm dia as reinforcement to concrete. After placing the additional reinforcement all concrete surfaces shall thoroughly scrubbed with brushes, washed with water and alloy to dry . To this surfaces apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness ) gunniting mix (using 1 part of ordinary Portland cement 53 Grade and 2 parts of ghaggar sand mixed with adhesive / admixture at the rate as directed) with a pressure of 2 to 2.5 Kg per Sq cm by gunniting machine and surfaces finished even and fair, incl necessary padding, shuttering / form work . Including 5 mm thick cement plaster in CM (1: 4 ) complete all as specified and directed . Note:- (a) The rate is inclusive for scaffolding or reqd necessary arrangement for multi-storey bldg external gunniting.
M & L for complete removal of existing roof treatment (Mud puska, Cement Tiles, bricks or Old APP Roof treatment and vegitation from root) including bedding layer in cement mortar/Mud and disposed from MoD land complete all as specified and directed.
M&L 25mm thickness PCC 1:2:4 type B1 (using 12.5mm graded stone aggregate) mixed with 3.00% liquid water proofing compound as per manufacturer instruction as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed Note : Liquid with water proofing compound will be measure and paid seperately.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gms polestar non-woven fabric with scratched tool before finishing roof surface. When the concrete surface is still green, 10 mm thick 1:4 cement plaster shall be laid, the roof surface shall be thoroughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface, one coat of approved bituminous primer having density in the range of 0.87 to 0.89 / kg at 25 degree and viscosity of 70 to 160 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied. APP membrane shall be laid on primed surface torch application method after allowing 24 hours of primer to dry. Laying of APP membrane shall be commenced at the lowest level and worked upto the crest. APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with butane torch. This treatment shall be done by the approved authorized applicator. Guarantee of treatment shall be for 10 years. (ii) Independent testing of membrane for the approval technical parameters specified hereinafter shall be carried out the approved laboratories like National test house any other Govt approved laboratory having facilities for the testing of membrane.
M&L for 2 coat of water proof aluminum paint incl preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed by Engineer-in-charge
M&L for Non skid ceramic coloured / light shade, premium quality tiles (400mmx400mm)x7 mm thick as decided by EIC in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thick as in levelling course ,finished surfaces even and rough to receive floor finish complete all as specified and directed.
M&L for glazed ceramic coloured tiles/ light shade, premium quality tiles including designer tiles of size 350mm x 250mm x 7mm/450mm x 350mm x 7mm thick or as decided by EIC over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces or as in highlighter, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
Dismantling of Stone slabs laid, bedded and pointed in any mortar complete all as specified and directed
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete includung 20 mm screed bed in cement mortar 1:6 complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete all as spd and directed
Taking up or down 20mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete all as spd and directed
S&F 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall including chesing & ceiling or laid in floors complete all as spd and directed by Engr-in-charge.
S&F 20mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as spd and directed by Engr-in-charge.
S&F in repair 15 mm pillar taps swan neck cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered "Hot" or Cold with long screwed shanks and fly nuts screwed for iron pipes and fixed , fancy type complete all as specified and directed
S&F in repair for sensor Urinal, Half stall type, white/colour/ star white size 37x19x61cm including all fitting and fixture complete all as specified and directed.(hindware Cat No.60018, or equivalent )
S&F in repairs vitreous china counter top wash hand basin of size 45x37x14.5cm white, , complete all as specified and as directed by Engineer-in-Charge. (hindware Cat No.10104, or equivalent )
S&F 32 mm dia brass chromium plated bottle trap complete all as specified and as directed
S&F in repair vitreous china wash down water closet pan (pedestal pattern, one piece) white, size 65.5x38.5x76.5cm with integrated flushing cistern, including making good complete all as specified and directed. (hindware Cat No.92562(S-22), or equivalent )
S&F in repair for PVC connection 15mm dia and 600mm long complete all as specified and directed.
S&F in repair half length wall hung urinal division of frosted glass of thick ness 8mm to 10mm, and size 600x1950mm complete all as specified and directed. (hindware Cat No.SU81CXF-06H19-CR 600 or equivalent )
S&F in repair CP stop/angle valves, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified and directed
S&F fancy type mirror of 8 to 10 mm thick glossy glass decorative/ designer type, any size and shape bevelled edges all-round as decided by EIC, wall mounted mirror complete all as specified and directed by Engineer-in-Charge.
S&F in repair for brass CP towel rail of 15mm dia with hook 600mm long complete all as specified and directed by Engr-In-Charge.
S &F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed
S&F in repair CP bib taps long body , cast copper alloy, fancy type with with wall flange, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete all as specified and directed by Engr-In-Charge. (hindware Cat F360004SCP or equivalent )
S&F In repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all as specified and directed
S&F in repair 15mm dia brass CP jet with CP flexible pipe 90cm long incl necessary fittings complete all as specified and directed .
S&F as in repairs, liquid soap dispenser with s/s metallic bottle complete, all as specified and directed
S&F hand drier in rugged multiple stoved, multiple grounded steel enclosure with one bracket for firm wall fixture having features of No touch operation, solid state time delay to allow user to keep hands in comfortable position complete all as specified and as directed
Dismantling water tank and removing to store exceeding 500 but n.exc 1000 ltrs complete all as specified and directed.
S&F for rotational molded polyethylene water storage tanks (white colour) of 1000 ltrs capacity (cylindrical vertical with closed threaded top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, bore dia of pipe 20mmwith iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair for 110mm bore PVC (SWR) pipe single socketed any length with rubber ring joints fixed on walls or laid in trenches , in floor or in under sunken system, including taking down complete all as specified and directed. NOTE :- Rate includes core cuttings of RCC slab/cutting holes in wall and all fittings as branch piece/ junction , single/ double/ triple , equal/ unequal.
S&F in repair for 75 mm bore PVC (SWR) pipe single socketed any length with rubber ring joints fixed on walls or laid in trenches , in floor or in under sunken system, including taking down complete all as specified and directed. NOTE :- Rate includes core cuttings of RCC slab/cutting holes in wall and all fittings as branch piece/ junction , single/ double/ triple , equal/ unequal.
S&F in repair 150mmx150mm floor drain with cockroach trap build with 1mm thick 304 grade stainless steel with complete set ( Frame, drain cover, outer cup, inner cup etc. including jointing with solvent cement complete all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45x85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length including making good complete as per direction of Engineer-in-Charge: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) moulded decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F for Butt hinges of stainless steel 100mm size Heavy type complele all as specified and directed.
S&F for 150mm long stainless steel handles, fancy type, fabricated type. complete all as specified and directed.
S&F for 200 mm stainless steel, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for door stopper of of brass body and tongue with hard drawn steel spring, (140mm size), complete all as specified and directed.
M&L for 20mm thick prepolished Granite slab any colour/quality as approved by GE on top of platform, WHB counter and similar work including cutting rounding on edges etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding, polishing and cutting grooves for anti skid porpose complete all as specified and directed by Engr-In-Charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces (Cement plaster 1:4) finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces (Cement plaster 1:6) finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M & L for brick work with sub-class `B' bricks old size, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L Preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion over a coat of primer on walls complete all as specified and directed
M & L preparation of newly plastered surface and applying three coats of white wash on ceilings complete all as specified and directed.
M&L for preparing new surface and applying exterior paint (weather coat, apex ultima) of required shade,Two coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm, complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stoping of existing surface and making the surface even and smooth and apply Two coats of distempering Ist quality acrylic distemper (ready mixed) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour over a coat of 1.50 mm thick (average) wall care putty to bring the surface even and smooth complete all as specified.
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stoping of existing surface and making the surface even and smooth and apply two coats of white wash on ceilings complete all as specified and directed
M&L for complete removal of existing treatment machanically or mannually on old surface of wall and preparing surface and applying two or more coats 100 % acrylic based exterior emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt reistance 1st quality exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltr /10 sqm over and including priming coat of exterior grade primer applied @ 0.90 litre/10 Sqm including change of existing colour if required complete all as specified and as directed by Engineer-in-Charge. note; work will be executed upto fourth floor
Dismantling plain corrugated steel sheeting any gauage thick ness including Nainital and similar pattern complete all as specifed and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe410 (Gde E-250 quality-A) complete all as specified and directed by Engr-In-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc1.5 m in depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any hard / dense soil complete all as specified and directed by Engr-in-charge. Note:- Manual digging is permitted, if mechanical excavation is carried out by the contractor all damages of existing services shall be repaired by the contractor at his own expenses.
Dismentaling old 200 mm bore ineer dia pipe and removing it complete all as specified and directed
S&F 200 MM bore (inner dia) double wall corrugated HDPE pipes (SN8) in any length including all fittings and jointing with elastomeric rubber rings and couplers / other jointing materials as per manufacturers instructions, all as specified and directed.
M & L for cutting in to existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch camel ( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required of 150 mm/200mm/300mm dia of pipe complete all as specified and directed by Engr-in-charge.
M & L for concrete bed PCC 1:4:8 Type D2 (Using 40mm graded aggregate) to drain pipes 200 mm dia including packing under and hunching against the sides of pipes after they are laid and tested all as specified and as directed by Engr-in-Charge.
M & L for Returning & filling in including spreading, levelling, watering & well ramming in layers n.exc 25mm thick in soft/ hard / dense soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed by Engr-in-Charge.
S & F in repair aluminum window with aluminum anodized frame of aluminum section 62.5 x 37 x 2.5 mm thick with shutters having styles & rails of aluminum section 44.45 x 44.45 x 2.5 mm thick including jointing cleats, glazing clips, rubber packing, aluminum snap beading, screws anodized aluminum fittings such as hinges, tower bolts, handles etc including 5.5 mm thick ordinary plain glass complete. Including providing and fixing aluminum chequered grill of anodized section of mesh 100x100mm of 08 mm dia of bar fixed to frame with 20x20 mm aluminum flat with mire mesh fixed with screw complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection complete as directed.
M&L for removal of old debris /malba with tractor trolley completely and make the existing area level complete all as specified and directed by engr-in-charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No-104 above but one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No-104 above but for one 3 pin socket out let, 6 Amps on Independent board
All as per item No-104 above but for one 3 pin socket out let, 6 Amps on same board
All as per item No 104 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed.
S & F Modular Socket, 6A - 3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed .
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed .
S & F Modular Socket, 16A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/ Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed.
S&F electronic modular fan regulator rotary flush step type 120 watt, 240 volt complete all as specified and directed
Taking down wall mounting fan of any size dismantling blades and removing fan and blades to and deposit to MES store after making serviceable Complete all as specified and directed by Engineer-in-Charge.
S&F wall mounted fan of 400 mm sweep, 03 blades aerodynamically balanced with 60 degree oscillation, air delivery not less than 55 M3/Min, 1350 RPM, 230 V, 50Hz and Noise level not more than 64 dB with 2 years warranty complete all as specified and directed.including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
Servicing and cleaning of wall mounted fan received from item No 115 and refixing including electrical connection complete all as specified and directed.
Taking down old unsv ceiling fan, cable end, disamntling blades and recmoving fan and blades for servicing/ deposite to store yard.
S & F efficient BLDC ceiling fan 1200mm sweep, 28 Watt with remote, ISI mark with 5 star rating, white colour, single phase including all fixing arrangement handing in roof like suitable size of fan raod clips, bolt, nut washers and 3 core flexible copper wire of size 1.5 Sqmm not less than 0.5 mtr long with all accessories complete all as specified and directed.
Refixing of ceiling fan of any size sweep after cleaning, servicing and painting with enammeled paint with paint gun (white paint) complete replacing the unsvercieable minor parts i.e. rubber real and clamp, canopy and rod complete all as specified and directed. Note : Rate are inclusive for minor spare parts and painting work under this items
Supply and fixing warm white LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specifed and directed .
Taking down unsv submain wiring of alluminium two/three runs of any size cable including batten/ conduit complete etc and making good disturbed surface complete all as specified and directed
M&L for submain wiring with two run single core 10.0 Sqmm PVC insulated but unsheated FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 Sqmm PVC instulated but unsheated FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non merallic PVC conduit, medium grade, ISI marked (not less than 20mm dia) coomlete with all acessories and fitting all laid/ fixed concealed in wall/ ceiling or surface in wall and surface conduit on ceiling and also include the specified runs of specified size earth continuity conducto of similar type cable complete all as specified and direced. Note : 2 Runs of 10.0 Sqmm single core and one run of 10.0 Sqmm single core cable and one run PVC conduit consider one unit
M & L for submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable and one run PVC conduit consider one unit
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 4.0 Sqmm single core and one run of 4 sqmm single core cable and one run PVC conduit consider one unit
Supply and fixing in replacement load line vertical distribution board made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for supply and fixing of FP incomer MCCB of 160 Amps 25 KA complete all as specified and as directed by Engineer-in-Charge. Note for MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type horizontal type complete all as specified and as directed . Note : MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link ,earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type complete all as specified and as directed. Note : MCB shall be measured and paid seperately
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type horizontal type complete all as specified and as directed. Note : MCB shall be measured and paid seperately
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps flush in wall including cutting chases in wall for fixing DB and making good the disturbed wall surface to match with existing specification.
Taking down unserviceable SP/ SPN MCBs of any capacities from the MCB DBs after disconnecting the electric supply complete all as specified.
S&F for MCB SPN 32 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed.
S&F for MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed
S&F for MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
M&L for conductive concrete Earth Grid of multiple interconnected Earth Electrodes to achieve the earth resistance value of less tham 5Ω. The excavation is to be carried out in any type of soil including hard rock. The approx specification are as under :- (i) Earth Electrodes : Metal conductor- copper bonded MS rod dia 17.2mm (+/-.5mm), Length 2.25 meter with conductive concrete including provision of bore 65mm dia, 2.25 meter length of earth electrode. (ii) All earth electrodes (min two nos) should be installed to achieved the desired result. (iii) Interconnected strip : All the multiple Earth Electrodes will be horizontally interconnected with metal conductor- Copper strip flat size: 25mm x 3mm & conductive concrete embedding size : 60mm2. (iv) Test Link : Copper strip flat size : 40mm x6mm x200mm shall be provided, at any one of the multiple Earth Electrodes of the grid for connection between earth grid pit and application. (v) Pit cover : RCC pit cover & frame shall be provided at all Earth Electrode (with test links) Note : (a) Bidder shall produce certificate for resistivity of conductive concrete. (b) Fault current tested at 40 KA Peak with 17.2 mm copper bonded rod. (c) On completion of work Engr- in- charge will check the earth resistance in presence of user, contractor will re-do the earthing if earth resistance value is more than 5 Ohm if value not found as per contract the necessary action to be taken by the contractor for achieving the desire result. (d) All connecting strips would be copper of size 20x3mm and cost of the same is included in the rate quoted, upto test point. (e) Test certificate of earthing material for ROHS compliance, resistivity value and fault current test for electrode from certified NABL laboratory shall be submitted. (f) Contractor will anually check the resistance value of earth grids after completion of work. (g) The vendor to provide CPRI test report for current greater than 20 KA with peak at 40 KA, the report shall not be more then 5 year old from the date of tender. (h) The product shuould be ROHS compliance.
Supply and fixing in replacement LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing in replacement LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
S&F of exhaust fan heady duty metal body type 300 mm sweep with blades, and frame and louvers including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm.
Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm laid in in trenches as protection to cable all as specified and directed by Engineer-in-charge
Supply and laying XLPE LT 1100 Volt Grade, armourd under ground cable size of 10 Sqmm 2 core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified and directed.
deepankar trading co. (BID ID -3498916)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx