Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC NEAR OLD INDIAN OIL DEPOT JALANDHAR JAMMU BYE PASS ROAD PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being lowest bid. | |
| 2 | L2₹22.7 L+₹1.9 L (9.04%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid. | |
| 3 | L3₹24.2 L+₹3.4 L (16.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid. | |
| 4 | L4₹34.8 L+₹14.0 L (67.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
9 Aug 2022, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT 145001
REPAIR/MAINT OF WATER SUPPLY PIPE LINE, CLEANING OF OHT, UG SUMPS AND ALLIED MISC WORKS UNDER GE (SOUTH) MAMUN
2022_MES_537489_1
GE(S)/M-04/2022-23
Open Tender
Miscellaneous Works
Item Rate
270 days
GE SOUTH MAMUN
AS PER NIT
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹50,000
Yes
14 Sept 2022
12 Jul 2022
16 Aug 2022
12 Jul 2022
9 Aug 2022
26 Jul 2022
Amount
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr. In depth, for taking out/laying of DI/CI/ GI Pipes and getting out Hard/dense soil by JCB Machine /manually as per site requirement complete all as specified and directed.
Returning, filling in including spreading, leveling watering and well ramming in layers in Hard/dense soil complete all as specified and directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed.
Taking up CI/DI water mains 80mm bore (including all fittings) with spigot and socket ends (CI pipe line burning out lead joints for recovering lead) for removing blockage and damaged pipe complete all as specified and directed. Note :- (i) Earth work will be measured and paid separately under relevant item of sch
All as per srl item No 4 here in before but for 100mm bore complete all as specified and directed.
All as per srl item No 4 here in before but for 150mm bore complete all as specified and directed.
All as per srl item No 4 here in before but for 200mm bore complete all as specified and directed.
Relaying of old CI/DI pipes 80mm bore, pipes obtained from No.4 here-in- before with spigot and socket ends in new or old position in any length, laid in trenches/surface after cleaning of inner surface complete all as specified and directed.
All as per srl item No 8 here in before but for 100mm bore obtained from item No 5 complete all as specified and directed.
All as per srl item No 8 here in before but for 150mm bore obtained from item No 6 complete all as specified and directed.
All as per srl item No 8 here in before but for 200mm bore obtained from item No 7 complete all as specified and directed.
Supply and laying Cast iron pipes of 80mm bore with spigot and socket ends, centrifugally cast class LA in any length laid in trenches or surface etc. testing complete all as specified and directed. Note :- (i) CI special fittings will be measured and paid separately under relevant item of sch.
Supply and laying in trenches or on pillars centrifugally cast DI pipe (spun) 100mm dia class K7 in any length laid in trenches/surface complete all as specified and directed. Note :- (i) DI special fittings will be measured and paid separately under relevant item of sch.
All as per srl item No 13 here in before but for 150mm bore complete all as specified and directed.
All as per srl item No 13 here in before but for 200mm bore complete all as specified and directed.
M&L for replacement 150mm dia CI /DI pipe with centrifugally cast (spun) ductile iron pipe (DI) 150mm bore dia with flanged ends in any length laid in trenches/surface with rubber insertion packing 3mm thick complete including taking down old one complete all as specified and as directed. Note :- (i) DI special fittings & earth work will be measured and paid separately under relevant item of sch.
Labour only for run lead joints 80mm to 200mm bore CI Pipe complete all as specified and directed. Note:- Lead retrieved from item No 4 to 7 here-in-before during taking up/down shall be used in this item.
M&L for Run lead joints upto 200mm bore cast iron pipes and fittings etc., (Spigot and Sockets) after testing the joint complete all as specified and directed.
S&F in replacement tyton/ rubber gasket for DI fittings and pipe upto 200mm bore complete all as specified and directed.
M&L for repair to joint leakage of CI/DI pipe line of any dia , by cocking and inserting extra lead/gasket/nut bolts rubber sheet clamp if any required at site and making the joint leakage free, including necessary excavation and earth work, returning filling and testing the joint complete all as specified and directed.
M&L of CI/DI fittings upto 200mm bore such as bends (any type radius and angle) Tappers (any type straight, bend, increasing, decreasing or double socket etc), Tee , single branch, Y junction, double branch, connecting pieces one end flanged and other socket or spigot and bell mouth pieces, Collars, Caps and plugs etc, including dismantling old one complete all as specified and directed.
M&L for repair in leakage/ blocked ferrule joint of water connection pipe by using rubber sheet, clamp & nut bolts and any other material reuired at site for making the existing joint leakage free, including necessary excavation and earth work, returning filling and testing the joint complete all as specified and directed.
Taking out GI Pipe 15/20mm bore with all fittings and accessories etc, from trenches/ surface and removing blockage and damaged pipe complete including cleaning the serviceable pipe for re-fixing complete all as specified and directed. (Note:- Excavation/earth work shall be measured and paid for separately).
All as per srl item No 23 here in before but for 25mm GI bore pipes complete all as specified and directed.
All as per srl item No 23 here in before but for 40mm GI bore pipes complete all as specified and directed.
All as per srl item No 23 here in before but for 50 mm GI bore pipes complete all as specified and directed.
All as per srl item No 23 here in before but for 80mm GI bore pipes complete all as specified and directed.
All as per srl item No 23 here in before but for 100mm GI bore pipes complete all as specified and directed.
Relaying of old GI pipes 15/20mm bore, retreived from No.23 here-in- before in new or old position in any length, laid in trenches/surface after cleaning of inner surface complete all as specified and as directed
All as per srl item No 29 here in before but for 25mm bore retreived from item No 24 complete all as specified and directed.
All as per srl item No 29 here in before but for 40mm bore retreived from item No 25 complete all as specified and directed.
All as per srl item No 29 here in before but for 50mm bore retreived from item No 26 complete all as specified and directed.
All as per srl item No 29 here in before but for 80mm bore retreived from item No 27 complete all as specified and directed.
All as per srl item No 29 here in before but for 100mm bore retreived from item No 28 complete all as specified and directed.
M & L for 15 mm bore "medium grade" galvanised iron pipes with all fittings complete to walls and ceilings or laid in floors /trenches complete all as specified and directed complete all as specified and directed.
All as per srl item No 35 here-in-before but for 20mm GI bore pipes complete all as specified and directed.
All as per srl item No 35 here-in-before but for 25mm GI bore pipes complete all as specified and directed.
All as per srl item No 35 here-in-before but for 40mm GI bore pipes complete all as specified and directed.
All as per srl item No 35 here-in-before but for 50mm GI bore pipes complete all as specified and directed.
All as per srl item No 35 here-in-before but for 80mm GI bore pipes complete all as specified and directed.
All as per srl item No 35 here-in-before but for 100mm GI bore pipes complete all as specified and directed.
Supply and fixing of cast iron flanged ends sluice valve suitable for 80 mm dia pipes conforming to IS - Class PN - 1.6 with MS nuts, bolts, washers etc, including taking out/ dismantling old unserviceable one and testing complete all as specified and directed.
All as per srl item No 42 here in before but suitable for 100 mm dia pipe complete all as specified and directed.
All as per srl item No 42 here in before but suitable for 150 mm dia pipe complete all as specified and directed.
All as per srl item No 42 here in before but suitable for 200 mm dia pipe complete all as specified and directed.
All as per srl item No 42 here in before but suitable for 250 mm dia pipe complete all as specified and directed.
Supply and fixing of cast iron flanged ends Non Return Valve suitable for 80/100 mm dia pipes with MS nuts, rubber gasket ,bolts, washers etc, as approved including taking out/ dismantling old unserviceable one and testing complete all as specified and directed.
All as per srl item No 47 here in before but suitable for 150 mm dia pipe complete all as specified and directed.
All as per srl item No 47 here in before but suitable for 200 mm dia pipe complete all as specified and directed.
S&F in replacement CI Ball valve Screwed Ends suitable for 15 mm dia pipe complete all as specified and directed.
S&F in replacement CI Ball valve Screwed Ends suitable for 20mm dia pipe complete all as specified and directed.
Supply and fixing gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed suitable for 20mm bore pipe including dismantling and taking out existing unserviceable one complete all as specified and directed.
All as per srl item No 52 here in before but suitable for 25 mm bore pipe complete all as specified and directed.
All as per srl item No 52 here in before but suitable for 40 mm bore pipe complete all as specified and directed.
All as per srl item No 52 here in before but suitable for 50 mm bore pipe complete all as specified and directed.
M&L in replacement of GI fittings such as Tee, elbow, bend, reducer, socket, nipple and union etc of size from 15mm to 100 mm dia of ISI quality complete all as specified and as directed.
M&L for brick masonry work for repair to valve pit/pillars or any as per site requirement with well burnt Sub class 'B' in CM 1:4 complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair face of brick work and finished the surface even and smooth complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of old surface of valve pit cover of size 40mmx40mm and applying two coats of black paint complete all as specified and directed.
Taking out the broken, rusted, valve pit cover of any size and M & L for fixing valve pit cover of suitable size to existing made of 3mm thick MS sheet/plate including provision of hinges, handle and locking arrangement including 40mm x 40mm x 4mm iron frame fixed or top of valve pit , including two coat of anti-corrosive paint over a coat of red oxide primer complete all as specified and directed.
Materials and labour for preparing 80/100/150mm bore DI/CI/GI pipe (outer surfaces) and applying two coats of synthetic enamel paint such as rising main (Red), delivery pipe (Blue), overflow & washout pipe (yellow), etc, over a coat of red oxide zinc chromate primer complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 ( 20 mm graded crushed stone aggregate) as in making cement concrete thrust block for supporting of pipe bend, tee & dead end etc. complete all as specified and directed.
Repair/replacement of lead/rubber gasket joints of 150mm bore CI/DI pipe vertical line of overhead tank including extra lead and rubber gasket complete all as specified and directed.
M&L for cleaning to chambers internal surfaces of RCC overhead reservoir capacity 25000 glns, 18 mtr staging or above of any type by removing bleaching powder/Al-Tock residue, silt sand, mud, fungus etc with steel wire brush and getting out. Cleaning, washing and flushing including writing date of cleaning and due date of cleaning with synthetic enameled white paint on black back ground (Black back ground shall be painted with synthetic enameled black paint) letter n.exc. 10cm in height including all T&P required. Three Photographs of inside surface of tank of each OH Tanks should be taken before cleaning & after cleaning and submitted to Engineer-in-charge complete all as specified and directed. Note:- (i) Rates are to be including charges of hiring T&P. (ii) Contractor shall be responsible for care and safety of person deployed for cleaning to off reservor.
All as per srl item No 65 here-in-before but capacity 50000 glns complete all as specified and directed.
All as per srl item No 65 here-in-before but capacity 75000 TO 150000 glns complete all as specified and directed.
M&L for cleaning to chamber/chambers internal surfaces of RCC semi underground sump 50000 glns capacity any type by removing bleaching powder/Al-Tock residue, silt sand, mud, fungus etc with steel wire brush and getting out. Cleaning, washing and flushing including writing done/due date of cleaning with synthetic enamelled white paint on black back ground (Black back ground shall be painted with synthetic enamelled black paint), letter n.exc. 10cm in height including all T&P required. Three Photographs of inside surface of tank of each OH Tanks should be taken before cleaning & after cleaning and submitted to Engineer-in-charge complete all as specified and directed. Note:- (i) Rates are to be including charges of hiring T&P. (ii) Contractor shall be responsible for care and safety of person deployed for cleaning to off reservor
S&F in replacement aviation LED light die cast aluminium alloy housing red coloured polycarbonate dome & accessories including LED lamp complete, commissioning & testing complete all as specified and directed.
Supply and fixing in replacement for Sheet metal enclosure, factory made suitable for DB's 240 Volts single pole and neutral 2 Ways with 200 Amps without bus bar, complete all as specified and directed.
S&F in replacement MCB single pole with natural 240 volts 20 to 40 Amps complete all as specified and directed.
S&F in replacement Weather proof PVC flat twin core aluminium conductor of size 4.0 sqmm with all fixing accessories complete all as specified and directed.
M&L for repair/servicing to over head water level indicator gauge complete with replacement of floot valve steel 200mm, Pully as per site requirement,steel pulling wire,fixing clumps etc and applying two coats of super enammeled black paint over a coat of red oxide paint on whole scale and rewriting of existing marking with super enammeled white paint to scale of overhead tank /sumps etc complete all as specified and directed. Note-: (i) Rates are to be including charges of hiring T & P. (ii) Contractor shall be responsible for care and safety of person deployed.
M&L for preparation and painting the external surface of over head resorvior wire having staging 18 mtr capacity 25000 glns with two coats of exterior grade weather proof Cement base paint After Priming plastered and other surfaces with alkali resistant priming paint and painted to over head tank, railing and iron laddor ,doors with super synthetic, heat resistant paint complete all as specified and directed including all existing writing works with enammeled paint complete all as specified and directed. Note:- (i) Rates are to be including charges of hiring T & P. (ii) Contractor shall be responsible for care and safety of person deployed for cleaning to off reservor.
All as per item No 76 here-in-before but for 50000 glns capacity complete all as specified and directed.
All as per item No 76 here-in-before but for 75000 to 150000 glns capacity complete all as specified and directed.
M&L for preparation and painting the external surface of the Semi underground sump capacity 50000 glns with two coats of exterior grade weather proof Cement base paint after Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed for following capacity including all existing writing works with enameled paint complete all as specified and directed. Note-: (i) Rates are to be including charges of hiring T & P. (ii) Contractor shall be responsible for care and safety of person deployed for cleaning to off reservor. (iii) Three Photographs of inside surface of tank of each OH Tanks should be taken before cleaning & after cleaning and submitted to Engineer-in-charge.
M&L for repair to mild steel ladders, grill, covers installed on overhead tank / sumps by replacing of defective /corroded pieces including cutting ,welding & painting with two coat high quality synthetic enamel painted black colour to match existing surface complete all as specified and directed.
S&F in replacement PVC insulated and FR PVC Round Sheathed, flexible Copper Conductor 0.5 Sqmm, 6/8 core control cable, 1100 Volts, conforming to IS: 694 for water level indicator fixing on wall or hanging in air with the help of GI wire complete all as specified and directed.
Replacement of old U/S water level indictor of any type with new for Water Level Indicator with Low & High Water Level Alarm conforming with 4 levels of LED indication representing 25%, 50%, 75% and 100% levels in the tank, Power ON Led indication, Audio & visual Level indication including with 4 Nos moulded silver steel contact type sensor complete all as specified and directed.
M/S MALHOTRA ENGINEERS
KULBHUSHAN AGGARWAL
dadwal engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .