Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.3 LAccepted-AOC | L-1 | Accepted-AOC AWARDED TO L1 | |
| 2 | L-2₹25.1 L+₹80,505 (3.31%)Rejected-Finance | L-2 | Rejected-Finance L-2 |
Tender Value
₹23.5 L
EMD Value
₹47,098
Closing Date
29 Mar 2025, 6:00 pmClosed
DIRECTOR CDRI LUCKNOW
CDRI LUCKNOW
Annual maintenance contract for electrical works of housing areas Jankipuram, Sector-K Aliganj and Nirala Nagar dispensary of CDRI for the year 2025-26
2025_CSIR_229254_1
2/02/2025-Engg
Open Tender
Electrical Works
Item Rate
365 days
CDRI LUCKNOW
As per NIT and Tender document
3 documents required · 3 mandatory
₹0
₹47,098
14 May 2025
8 Mar 2025
31 Mar 2025
8 Mar 2025
29 Mar 2025
8 Mar 2025
Amount
Point wiring
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required: Group ‘B’.
Supply and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ heavy gauge PVC conduit/ casing capping etc as required:
1)2x1.5 Sq.mm
2)3x1.5 Sq.mm
3)2x2.5 Sq.mm
4)3x2.5 Sq.mm
5)2x4 Sq.mm
6)3x4Sq.mm
7)2x6 Sq.mm
8)3x6 Sq.mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required:
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1)1 way 5/6 amps
2)1 way 15/16 amps
3)5 Pins Socket 5/6 amps
4)6 Pins 15/16 amps socket
5)Telephone socket outlet
6) Bell push switch
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/modules.GI box along with modular base and cover plate for modular switches in recess etc as required.
a) 1 or 2 Module (75mmX75mm)
b) 3 Module (100mmX75mm)
c) 4 Module (125mmX75mm)
d) 6 Module (200mmX75mm)
e) 8 Module (125mmX125mm)
f) 12 Module (200mmX150mm)
Supplying and fixing following modular base and cover plate on existing modular metal boxes etc as required.
a) 1 or 2 Module
b) 3 Module
c) 4 Module
d) 6 Module
e) 8 Module
f) 12 Module
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of wall bracket /ceilingfittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell suitable for single phase, 230Volt, 50Hz on the existing box excluding connections etc as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorecsent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
a) Upto 450 mm sweep
Extra for fixing the louvers/shutters completes with frame for exhaust fan of all sizes.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
a)100 A, 16 KA,TPMCCB
b)125 A, 16 KA,TPMCCB
c)150 A, 16 KA,TPMCCB
d)200 A, 16 KA,TPMCCB
e)315 A, 35 KA,TPMCCB
f)400 A, 50KA, FPMCCB
g)630 A,50KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 6way, Double door
b) 8way, Double door
c) 12way, Double door
d) 16 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
a) 4 way (4 + 12), Double door
b) 8 way (4 + 24), Double door
c) 12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
i) Single pole
ii)Single pole and neutral
iii) Triple pole
iv)Triple pole and neutral
Supply and fixing single pole blanking plate in the existing MCB D.B. complete etc. as required.
Supply and fixing following rating, double pole, 240 V isolator in the existing MCB D.B. complete with connections, testing and commissioning etc as required.
i) 40 amps.
ii) 63 amps.
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600mmx600mmx3mm thick including accessories, and providing masanory enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal / coke and salt etc. as required.
Supply and laying 25mmx5mm copper strip at 0.5 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc as required (Joining shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50mm) .
Proviiding and fixing 25mmx5mm copper strip in 40 mm dia G.I. pipe from earth electrode, including connection with brass nut bolt and spring washer, excavation and refilling etc as required.
Providing and fixing 25mmx5mm copper strip on surface or in recess for connections, etc as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required:
a)Upto 35 sq.mm
b)Above 35 sq.mm and up to 95 sq.mm
c)Above 95 sq.mm and up to 185 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 K V grade of following sizes on wall surface as required:
a) Upto 35 sq.mm (clamped with 1mm thick saddle)
b) Above 35 sq.mm and up to 95 sq.mm (clamped with 25x3mm MS flat clamp)
c) Above 95 sq.mm and up to 185 sq.mm (clamped with 25/40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland & heavy duty lugs for the following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grades as required:
a)3½ X 25 sq. mm (28mm)
b) 3½ X 35 sq. mm (32mm)
c) 3½ X 50 sq. mm (35 mm)
d) 3½ X 70 sq. mm (38mm)
e) 3½ X 95 sq. mm (45 mm)
f) 3½ X 120 sq. mm (45 mm)
g) 3½ X 150 sq. mm (50 mm)
h) 3½ X 185 sq. mm (57mm)
k) 4 X 10 sq. mm (25 mm)
l) 4 X 16 sq. mm (28mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
a) 4 X 16 sq. mm
b) 3½ X 25 sq. mm
c) 3½ X 35 sq. mm
d) 3½ X 50 sq. mm
e) 3½ X 70 sq. mm
f) 3½ X 95 sq. mm
g) 3½ X 120 or 150 sq. mm
Pole erection
Erection of metallic pole of above 4.5 metres and up to 6.5 metres length in cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 40mm nominal size) including excavation, refilling etc as required.
Dismantling of pole/street light standard / strut embedded in brick ballast foundation etc as required.
Supply, installation, testing and commissioning of 1200 or 1400 mm sweep of sizes , BEE 5 star rated, ceiling fan with brush less direct current(BLDC) motor, class of insulation:B, 3nos. blades, 30cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, air delivery minimum 215 CMM, 350RPM (tolerance as per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, tempreture rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V,50Hz, single phase AC supply, earthing etc. complete as required.
Supply of 1.1KV grade, PVC insulated and PVC sheathed heavy duty aluminium conductor cables of following sizes etc as required:
a)4 x 10mm square
b)4x 16mm square
c) 3&1/2 x 25mm square
d)3&1/2 x 35mm square
e)3&1/2 x 50mm square
f)3&1/2 x 70mm square
g) 3&1/2 x 95mm square
h) 3&1/2 x 120mm square
i) 3&1/2 x 150mm square
j)3&1/2 x 185mm square
Supply & installation of following type of energy efficient LED light fitting along with accessories and manpower, including dismantling of defective light fitting, etc as required:
a)9 or 10 Watt, 2feet stand alone industrial type aluminium extruded CW
b)18 or 20 Watt, 4feet stand alone industrial type aluminium extruded CW
c) 40 or 45 Watt, Post top lantern CW
d) 90 Watt, street light CW
e) 30 to 57 Watt, flood light CW
Dismantling of defective existing office light fixture or fan or exhaust fan of all sizes or point wiring and handing over the material to electrical section as required.
Dismantling of sub main wiring from the surface or reccessed , restoring the surface & handing over the materials to the electrical section, etc as required.
Dismantling of existing or defective old metal clad power switches, MCB enclosures, DB’s, after disconnection of cables / wires, restoring of walls and handing over the material to electrical section, etc as required.
Dismantling of various sizes of cable from the surfaces, restoring the surfaces & handing over the materials to electrical section, etc as required.
Supply & mounting of 3 or 4 pole, 63 Amps, 16KA, 415V MCCB on existing mild steel box or enclosure, etc as required.
Supply & fixing of sheet steel enclosure box for fixing of 63 or 100 or 125 or 160 or 200Amps 3 or 4 pole MCCBs etc as required.
Providing and fixing of 3mm phenolic laminated sheet/perspex sheet on existing metal board/box etc as required.
Supply & laying of 6 SWG GI earth wire along with existing aluminium power cable including end termination with proper size of lugs etc as required.
Supply & fixing of PVC made junction box, 280mmx170mmx130mm in size, should have panel type locking & incorpoprating arrangement for fixing of MCB & connector, including all the consumable hardwares, etc as required.
Supply & fixing of 4 pole, double stud type bakelite terminal for connection of power cable in street light circuit, including fixing in the existing junction box or pole & connections, etc as required.
Supply & fixing/replacement of defective 2.5MFD capacitor including testing of existing defective fan and its capacitor, etc as required.
Rewinding & repairing of ceiling, wall mounted and pedstal fan including machining of shaft for conversion into bearing type, its material and mapower, etc as required.
Rewinding & repairing of exhaust fan (above 300mm sweep) including machining of shaft for conversion into bearing type, its material and mapower, etc as required.
Rewinding & repairing of exhaust fan (upto 225mm sweep) including machining of shaft for conversion into bearing type, its material and mapower, etc as required.
Attending of electrical breakdowns and to carry out emergent nature of works, providing of following technical manpower, as and when required:
a)Electrician (Semi-Skilled/Grade-II)
b)Helper
Supply & fixing of following sizes of single phase, 230 volt, 50Hz metallic exhaust or fresh air fan, etc as required:
a)225 mm sweep
b)300 mm sweep
Supply and fixing 63 amps. rating 240/415 volts, ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required:
a) Single pole
b)Single pole and neutral
c) Triple pole
d) Triple pole and neutral
Supply & fixing of MCB sheet steel enclosure box, etc as required:
a) SPN MCB Enclosure
b) FP/ TPN MCB Enclosure
Supply and fixing of 40 amps, 30 mA rating 240/415 volts, RCCB in the existing MCB DB complete with connections, testing and commissioning etc as required.
a) Single pole and neutral
b) Triple pole and neutral
Unlowering/lifting up of defective 30 HP submersible pump motor set from existing bore and its dismantling including charges of supply of manpower, tripod and transportation etc as required.
Rewinding of defective 30 HP submersible motor stator, supply & fixing of upper and lower housing bushes, oil seal, thrust plate with segment of motor, machining & turning i.e. lathe work of rotor sleeve, bowl neck ring of pump, pump bowl bush, pumps sleeves(SS), supply or repairing & fitting of pump shaft impeller and machining/turning i.e. lathe work of impeller etc, as required.
Supply and installation of flange packings, nuts, bolts and washers for reassembling of the delivery line of 30HP submersible pump etc as required.
Lowering/lifting down / installation of repaired/rewinded 30 HP submersible pump motor set in the existing bore well, including making connections of motors, starters, testing & commissioning of 30 HP submersible pump motor with proper fitting, alignment including labour charges, tripod & all the consumables etc as required.
Rewinding of following capacity of 3phase induction motor of water supply pump, including replacement of defective bearings or overhauling , rotor balancing etc & re-installation of motor after all completion in totallity, etc as required.
a) 1.5KW/2HP
b) 2.3KW/3HP
c) 9.3KW/12.5HP
d) 15KW/20HP
Repairing of following capacity of water supply pump, including replacement of defective bearings/bushes/seals/machining of shaft/overhauling & sucessfully re-installation of pump in totallity, etc as required.
a) 1.5KW/2HP
b) 2.3KW/3HP
c) 9.3KW/12.5HP
d) 15KW/20HP
Cable fault localization/ detection of cable fault of all sizes of 1.1KV grade, PVC insulated and PVC sheathed heavy duty/XLPE aluminium conductor cables, etc as required.
Supply and fixing of driver/SMPS compatible for 40 to 90 Watt LED post top lantern and LED street light fittings including its replacement in existing and defective LED lights etc as required.
Supply & fixing of 5-30 amps, 230 Volt,50Hz, single phase KWh / energy meter with LCD display, Model EM101+Class 1 Base mounting including dismantling of defective meter, consumables and connections etc as required.
Supply & fixing of fully automatic star delta starter suitable for 40HP, relay range- 20-33 amps fitted with MN32FASD contractors including its connection etc as required.
Vaish Electricals (BID ID -832871)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .