Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹5.0 L+₹5,617 (1.14%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹5.7 L+₹76,589 (15.5%)Rejected-Finance 8 6TH CROSS MATHRU SHREE NILAYA OPP MAHARISHI RESIDENCE KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
7 Oct 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF CHIMNEY HILLS BANGALORE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINTENANCE AND REPAIR OF INTERNAL ELECTRIC SUPPLY SYSTEM OF OTM ACCN AT 58 SU AF STATION CHIMNEY HILLS
2022_MES_545867_2
8542/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I AF CHIMNEY HILLS BANGALORE
₹10,000
Yes
12 Jan 2023
16 Sept 2022
8 Oct 2022
16 Sept 2022
7 Oct 2022
23 Sept 2022
16 Sept 2022 - 19 Sept 2022
60 days
Amount
Taking down carefully aluminium point wiring light, fan, sockets or power complete from surface wiring or from concealed wiring without disturbing concealed conduit including fittings such as ceiling rose, light fittings of any type, fan regulators etc and making good to the disturbed surfaces wall ceiling floors to match existing surfaces.
S & F Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated unsheathed 1100 V grade cable including 1.5 Sqrnm copper conductor multi stranded PVC insulated unsheathed cable for earth continuity conductor in and including PVC casing and capping/conduit with all accessories and l.2mm thick PVC bóx with 3 mm uniform thick laminated ISI marked sheet cover for mounting of switches sockets regulators etc complete for one light point, controlled by one switch /5 amps one way one fan point controlled by one switch and regulator / one socket outlet point three pin 5 amps.
All as per item No.2 above but with 2.5 sqmm cable for socket outlet 3 pin 15 Amps on independent board incl 1.5 sqmm PVC standard copper conductor cable as earth continuity conductor
All as per item No.2 above but one staircase light control by two way switch.
S & F in repair switch piano 6 Amps one way flush type
S & F in repair switch piano 6 Amps two way flush type
S & F in repair switch piano 16 Amps one way flush type
S&F in repair socket, 2 in 1, 3 pin 5 Amps flush type
S&F in repair socket 2 in l, 3 pin 6 Amps and 3 pin 16 Amps flush type.
S&F in repair Switch socket combination , 2 in 1, 5 pin 6 Amps flush type with Box All as specified and directed .
S&F in repair Switch socket combination 2 in l, 5 pin 6 Amps/ 16 Amps flush type with box all as specified and directed .
S&F in repair PVC Box suitable for Switch socket 5 Amps combination with 4 hole all as specified and directed .
S&F in repair PVC Box suitable for Switch socket 16/20 Amps combination with 4 hole all as specified and directed .
S&F Socket top ,16 Amps ,3 pin all as specified and directed .
S&F in repair Call bell (Ding Dong Type), AC 230 VoIt, single pole 230V
S&F Lamp holder,Angle and batten type, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings all as specified and directed .
S& F Sunmica plate of size 50 mm x 50 mm suitable for Switch socket 5 Amps combination all as specified and directed .
S& F Sunmica plate of size 70 mm x 50 mm suitable for Switch socket16 Amps combination all as specified and directed .
Supply and fix in repair bell push 5 Amps single pole
Supply and fix in repair electronic fan regulator, AC 230 V, switch type all as specified and directed .
Supply and fix in repair fan regulator AC 230 V electronic socket type .
Supply and fix in repair ceiling rose 3 terminals .
Supply and fixing LED lights fitting 1x 20 W of lumens 100 /Watt ,220V, 6500 K,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt of lumens 100 /Watts,220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per directed by Engineer in charge .
Supply and fixing round shape 6 watt 220 volts AC recessed type,120 mm outer dimensions with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as per directed by Engineer in charge .
Supply and fixing round shape 12 watt 220 volts AC recessed type,170 mm outer dimensions with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as per directed by Engineer in charge .
Supply and fix LED Bulb ,E27 Type ,10 W of lumens 110 /watt,6500 K Temperature ,5 star rated all as specified and directed .
Supply and fix LED Bulb ,E14 Type , 10 W ,2700 K temperature all as specified and directed .
Supply and fix LED Bulb ,E27 Type ,12 W of lumens 110 /watt,6500 K,5 star rated all as specified and directed .
Supply and fixing LED Flameproof light fitting minimum 1x 16 Watt of lumens 100 /W, CMRI certified recommended for gas/ vaporgroup of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessoriesprewired and including connecting up with three core flexible copper conductor cable with suitable size all as per directed by Engineer in charge .
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as per directed by engineer in charge.
S & F MCB SP 6 to 32 Amps10 KA 240V 50HZ, ISI Marked .
All as per item No. 33 above but MCB SPN 6 to 32 Amps
S & F MCB TPN 32 Amps 10 KA 415V
S & F MCB TPN 40 to 63 Amps 10 KA 415V
Taking down Fans of any sweep dismantling into parts servicing, greasing/oiling parts including replacing cotter pin rubber ring shackle, check nut, bush/bearing of suitable sizes including re-assembling, fixing in position and testing complete.
Taking down existing Ceiling fan 1200 mm sweep from its location and Rewinding of ceiling fan/motor with super enameled copper winding wire of similar gauge and weight of the original winding insulating with class B, varnishing, drying etc complete, including refixing the same after carrying out the repair all as specified and directed .
All as per item No. 38 above but for exhaust fan 300 mm to 380 mm sweep
All as per item No. 38 above but for exhaust fan 450 mm sweep
All as per item No. 38 above but for wall mounting fan/pedestal fan upto 480 mm sweep .
Taking down geyser assembly 25/50 ltrs capacity of any type and detecting and rectifying leakage of inner tank by copper bracing and testing for leakage, assembly and refixing back incIudng reconnecting Inlet outlet water connections. Note: a) Soldering and minor spares are included in the quoted rate. b) Heating element and thermostat are measured and paid sepratly
S & F in repair heating element 2 KW of any type suitable for Geyser
All as per item No 43 above but 1.5 KW Note for item No.43 & 44 : The heating element shall be provided as per sampIe retrieved from Geyser
S & F in repair thermostat assembly stud type suitable to adjust the temp upto 70 Degree Celsius
S & F in replacement fan capacitor 2.5 MFD suitable for AC 240 V 50 HZ
S & F in replacement sheet metal enclosure single pole and neutral with 3 pin and earth plug with socket complete with one MCB SP 20 Amps
S & F in repair MCB distribution board SPN 4 way single door 240V powder coated with 200 Amps rated bus bar neutral link etc.
All as per item No. 48 above but SPN 8 ways
All as per item No. 48 above but TPN 4 ways
All as per item No. 48 above but TPN 6 ways
M&L earthing complete with galvanised steel pipe electrode of size,40 mm bore,medium grade,2.5 meter length, burried directly in bore 350 mm dia verticalIy to a depth not less 2.25 meter below ground level with top edge of the pipe not less than l.25mtr below normal ground level connected to galvanised earth lead wire 4.0mm dia by means with bolts, nuts check nuts and washers protected by Gl light grade pipe of size 15 mm dia and connecting up with the DB as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, PCC Chamber, RCC Cover, watering pipe 20mm dia GI Medium grade with funnel and wire mesh, Charcoal dust, salt, all as per plate no.4 of SSR 1991 and as directed by Engineer in charge. Note-Boring Charges are included above quoted rates.
M&L Spray painting of ceiling fan, Exhaust fan, Wall Mounting, Pedastal fan of any sweep including diconnecting, taking down, scrapping the old paint, filling cavities and spray painting with one coat of synthetic enameled white paint, numbering with black enamel paint, refixing in position connecting testing complete all as specified and as directed.
M&L in replacement submain wiring /Circuit wiring with PVC insulated, single core, multi stranded, 1100 volts grade unsheathed copper conductor cable in and including PVC Conduit/Casing capping with accessories fixed on wall /ceiling with GI screws complete with 2 runs of 1.5 Sq mm and one run of 1.5 sqmm for earth continuity conductor all as directed.
All as per item No. 54 above but 2X2.5 sqmm+1 X2.5 Sqmm
All as per item No. 54 above but 2x4 Sqmm +1x 4 Sqmm
All as per item No. 54 above but 2 x 6 sqmm+1x6 Sqmm
Supply and fix White cover module plate 3 module with frame all as specified and directed
Supply and fix Modular switch 1 way 6A,1 module complete all as specified and as directed.
Supply and fix Modular switch 1 way 16A,1 module complete all as specified and as directed.
Supply and fix Modular switch 2 way 6A,1 module complete all as specified and as directed.
Supply and fix Modular Bell push 6A 1 module
Supply and fix Modular socket 6A 2 /3 pin combined 2 module
Supply and fix Modular socket 16A 2 /3 pin combined 2 module complete all as specified and as directed.
Supply and fix Modular fan step type regulator 120W, 2 module complete all as specified and as directed.
Material and labour Corrugated PVC Pipe 20 mm dia all as specified and directed .
Supply and fix Exhaust fan GI Sheet louvers suitable for 300 mm sweep all as specified and directed.
RAMESH BABU CO
ARCHANA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .